PowerGUARD Energy Saving for inductive loads Saving 8%-15% Protection Power Quality.

Slides:



Advertisements
Similar presentations
“Power Factor” In Transmission System
Advertisements

ALPHA POWER SOLUTIONS Presented by Eric Solot An Introduction to Power Factor Correction.
POWER FACTOR IN ELECTRICAL ENERGY MANAGEMENT
Chapter 12 Transformers. Chapter 12 Transformers.
QUALITY AND TECHNOLOGY
COST EFFECTIVE SOLUTION TO REDUCING YOUR ENERGY BILL’S POWER MASTER Power Master, LLC, 2040 E. Ridge Rd, Rochester, NY, 14622,
Electrical Systems.  This section discusses: –How utilities charge for electricity –How to calculate the avoided cost of electricity –How to use utility.
Chapter 12 RL Circuits.
KW Energy Solutions, LLC Increasing Energy Efficiency Increasing Energy Effectiveness.
The Bottom Line In Energy Cost Reduction Energy Automation Systems, Inc. EASI.
PowaSava Energy Saving Systems A truly green system that is proven to reduce electric energy consumption Managing your energy, saving you money We won’t.
EXPERIMENTAL STUDY AND COMPARATIVE ANALYSIS OF TRANSFORMER HARMONIC BEHAVIOUR UNDER LINEAR AND NONLINEAR LOAD CONDITIONS.
Sinusoidal Steady-State Power Calculations
Alternating Current Circuits
KW Sentry ® Energy Controller (EC) It is a Desired & a Simple Solution for… RISING ENERGY COSTS It is a Desired & a Simple Solution for… RISING ENERGY.
Power Engineering Society Chicago Chapter Reactive Power: Sources and Solutions 12 February 2003 David E. Mertz, PE Burns & McDonnell Engineers, Inc.
Power Factor and Power Factor Correction
Lesson 27 Power Factor Correction
AC POWER ANALYSIS Tunku Muhammad Nizar Bin Tunku Mansur
Lecture 27Electro Mechanical System1  The fact that power is always positive reveals that it always flows from the generator to the resistor.  This is.
1 Locating Harmonic Sources System Impedance Impacts of Harmonics K-factor Interharmonics.
Example 10.6 Calculating Power in Parallel Loads
Alternating Current, Power Distribution, and Voltage Systems
Plant Utility System (TKK-2210)
Foundations of Physics
Utility Analysis. Baseline Electricity Analysis  Understanding and documenting current energy use is called developing a baseline. Developing a baseline:
General Licensing Class G5A – G5C Electrical Principles Your organization and dates here.
AC POWER ANALYSIS Tunku Muhammad Nizar Bin Tunku Mansur
Capacitors and Inductors.  A capacitor is a device that stores an electrical charge  It is made of two metallic plates separated by an insulator or.
Fundamentals of Electric Circuits Chapter 11
Voltage Voltage is the potential energy source in an electrical circuit that makes things happen. It is sometimes called Electromotive Force or EMF. Voltage.
Chapter 22 Alternating-Current Circuits and Machines.
American Control Technologies,Inc Power Factor Correction Technology 1152 West 2400 South Suite ‘C’ Salt Lake City, Utah
Technical Presentation on the new Power Saving Unit (PSU) Introduced By View Power.
Power Distribution Harmonics Case Study of 285-3F Chiller Plant Michael W. Harmon Principle Engineer Savannah River Nuclear Solutions, LLC Savannah River.
POWER FACTOR CORRECTION
Chapter 33 Alternating Current Circuits CHAPTER OUTLINE 33.1 AC Sources 33.2 Resistors in an AC Circuit 33.3 Inductors in an AC Circuit 33.4 Capacitors.
Power in AC Circuits ELEC 308 Elements of Electrical Engineering
ELECTRICAL ENGINEERING: PRINCIPLES AND APPLICATIONS, Fourth Edition, by Allan R. Hambley, ©2008 Pearson Education, Inc. Lecture 16 Phasor Circuits, AC.
Applied Harmonics Control of Harmonics
EGN 3373 Introduction to Electrical Systems I A Systems Approach to Electrical Engineering Graphics Adapted from “Physical, Earth, and Space Science”,
Lesson#28 Topic: AC Circuits
AC POWER ANALYSIS Instantaneous & Average Power
Chapter 7 AC Power Analysis
Module- optimizer ECOD. Feigin Electric solution-Module Optimizer “ECOD” New product which allows you to optimize the voltage within the norms laid down.
Circuit Master Circuit Master™ uses three PROVEN technologies* – Capacitor (reduces DEMAND) – Harmonic Filter (harmful frequencies) – Surge Protection.
Chapter 11 AC Power Analysis
Power System Fundamentals EE-317 Lecture 3 06 October 2010.
The EnergyMizer Power Reduction & Conditioning System ®
Three Phase Motors Maths
AC POWER ANALYSIS. 2 Content Average Power Maximum Average Power Transfer Complex Power Power Factor Correction.
REACTIVE POWER COMPENSATION
7/08/2002PP.AFD.07 Harmonic Quality1 of 49 Yaskawa Electric America Harmonic Currents, Voltages and Your Building Power System.
Presented by. What is Power Factor? Power Factor is the percentage of current delivered from the utility that is needed to perform the actual work. For.
FUNDAMENTAL OF ELECTRICAL POWER SYSTEMS (EE 270)
Unit 7, Chapter 20 CPO Science Foundations of Physics.
Power Factor Correction
KAIST NUCLEAR & QAUNTUM NICIEL SEMINAR 1 / 23 Review on Power Factor Young Seung LEE 04/26/2005 SEMINAR.
1 March 2001 EPCOS FK PM PFC Basics of Power Factor Correction BASICS OF POWER FACTOR CORRECTION.
Lesson 3: Ac Power in Single Phase Circuits
Power Factor Correction The Definitive power solution
Power Factor Correction The Definitive power solution
Effects of Harmonics on Capacitors Electrical System
Lesson 21: AC Power and Power Triangle
Reactance Reactance In Phase + _ + + _ _ Voltage Current Voltage
Electromechanical Systems
POLYPHASE CIRCUITS LEARNING GOALS Three Phase Circuits
Recorded Presentation
ELL100: INTRODUCTION TO ELECTRICAL ENGG.
PowerLogic™ offer for the basic metering market
Presentation transcript:

PowerGUARD Energy Saving for inductive loads Saving 8%-15% Protection Power Quality

Even after multiple measures have been applied to dave energy, the majority of installations still use electricity in an inefficient way Since motors and other inductive loads represent 70% to 80% of the total installed power, the quantity of energy losses is still high. The losses do not only affect the electricity bill, but also the cost of raw material, labor and production. Electrical Losses within a site

The electrical installations, unknowingly, suffer from energy losses du to harmonics, over-voltage, transiants, phase unbalance and incompatible impedance. The effects of magnetic waves in a site are generally underestimated as a source to save energy. In the world of electricity all sites are looked by the energy source as a circuit having an inductance in series with a resistance – therefore looking at the problem “magnetically” seams very logical. PowerGUARD treats the entire system by reducing the magnetic fields and improving the power quality and the total consumption PowerGUARD considers the site as a simple inductive load. PowerGUARD reduces the impedance of the site and therefore improves the transport of energy and reduces consumption. Total Solution

The cause of low Power Factor is the presence of inductive reactance in the circuit. To improve the PF to 1.0, we can either add a capacitive reactance (Capacitor) or reduce the inductive reactance (PowerGUARD) A commun practice to improve the power factor ne pratique commune pis to add capacitors. This method reduces the quantity of reactive energy supplied by the source, but also can creates resonance in the circuit and increase the temperature of equipments and transformers by creating over-voltage situations Whereas PowerGUARD allows to produce savings that can be verified and at the same time increases the power factor and protects the equipments against surges of current and voltage. Total Solution

PG Current generated in phase #1…. …is immediatly delivered to Phase #2…. …and to Phase #3, therefore neutralizing the Reactive current How PowerGUARD works By magnetic induction, a current is created and filtered to 60 HZ, this current is leading the voltage by more than 90 degrees, allowing it to flow to the opposite direction toward the source and neutralizing the reactive current

PowerGUARD benefits Voltage and current balancing Dynamic Power Factor correction Reduction of magnetic fields strength in the site Converting the energie created by overvoltage events to useful energy Equipments protection against surges Increases KVA capacity of Transformers Reduces the monthly bill

Effect on the environment PowerGUARD helps the environement. Every year, one 3-phase PowerGUARD 480 volts, can: Reduce up to 35,000 kWh and save 14 barils of oil, Avoid the emission of 9 tonnes of CO2 and Reduce the consumption of 800,000 liters of filtered water.

PowerGUARD vs Capacitors PowerGUARD Reduces the Inductive Reactance Capacitors Add to the Capacitive Reactance Benefits Dynamically improves the PF in the site Reduces Joules losses in the whole site Reduces KW demand Reduces KWh consumption Improves Voltage at the load Reduces temperature of the equipments Protection against Lightning and Transiants Life expectancy more than 20 years Guaranteed 3 years Improve the mains Improves PF of linear load YES Improve non-linear loads PF YESNO Preferred installation loocation In parallel to sub-panels or important loadsMains panel Possibility of motors self- excitation NOYES- Over correction Over voltage during low load NOYES Voltage RegulationImproves voltage unbalance of 3 phasesRisk of harmonic resonance may destroy equipments Reduces KWhYESNO – only through line losses reduction

General Diagram

Conclusion PowerGUARD allows: Protection of equipments against surges and lightning; Power Conditioning, Dynamic Power Factor Correction, Noise and RF reduction Reduction of line currents Reduction of KW demand Voltage balancing of the 3 phases Improves equipment efficiency such as Computers, VFDs, PLCs and Electronic ballasts; Reduction of 8% à 15% of the monthly bill Reduction of maintenance costs Payback between 12 and 30 months. The PowerGUARD units require no maintenance, guaranteed 3 years and a life expectancy of more than 20 years. Models are for domestic, commercial and industriel applications PowerGUARD is the only technology that offers all theses functions at the same time in the same product

Specifications PowerGUARD IND 3 Phase Delta Power Dissipation1250 Joules/min Peak Pulse Current Amps Max Surge Current(8 x 20 µsec) – Amps Nominal Clamping Voltage550 V RMS Max Steady State Voltage1500 V Response Time5 nanoseconds Total Capacitance255 µF KVAR21 Warranty3 years Dissipation Factor0.1% Max Stand by Power20 Watts Operating Temp.-40 C To +70 C Estimated Saving (Inductive loads)2.0 /3.0 KW

Case Study PG OFF PG ON reduction 12,2 KW PF increases from 0,96 to 0,99 Immediate reduction of 12,2 KW

OFFON Case Study The Graph shows the fluctuation in voltage due to the VFDs presence in the circuit When PowerGUARD is activated, there is an increase in voltage and a reduction in the deviation between the 3 phases.

Case Study OFF ON The Grapg shows that when the PG are ON, there is an increase in PF and KW decrease of an average of 7.5 KW. 3 PG units are intalled in paralled to a 300 KW electric Chiller ON OFF