APPENDIX 2. Common Batteries, NSNs, and CCAs

Slides:



Advertisements
Similar presentations
IGVC Power Team (BZZZZT!) Presentation October 17 th Electrical Engineering Senior Projects 1 Nate – Jake – Tim.
Advertisements

STARTING & CHARGING SYSTEM DIAGNOSIS
1 AUTOMOTIVE BATTERIES Battery function Battery parts Chemical actions Discharge cycle Charge cycle Battery ratings Battery Maintenance Charging Jumping.
Batteries & Battery Charging
Maintenance & Safety of Stationary Lead Acid Batteries
Electric circuit in the car. Under supervision Of Prof. DR/ Saad Abd El Hamid.
BATTERIES AND BATTERY CHARGING
The AGM Wet performance and its application to the VRLA battery
The Pro HD is an auto sensing 12/24V, 50 Amp charger designed to charge any type of lead acid battery (AGM, GEL, or flooded cell) using the supplied clamps.
VEHICLE BATTERIES PROGRAM.
BATTERIES Heart of the electrical system. Functions Supply energy to electrical systems when the vehicle is not running Operating cranking system Store.
Automotive Batteries.
ELECTRICAL I LESSON 2 BATTERY SERVICE
APPENDIX 1. Battery Management Program Flow Diagram
WHAT ARE AGM BATTERIES? Presented By: Bruce Purkey President Purkey’s Fleet Electric.
Electrolytic Cells Is a Galvanic Cell forced to operate in reverse Process is called electrolysis This occurs if a voltage greater than that produced by.
Lead Acid Batteries. Acquired in November 2000 by JCI Plant located in Aurora, Co Optima Batteries utilizes six sigma methodology TS Certification.
Red: Flooding, during a 10-day accumulation of MODIS imaging, ending on date shown. Light Red: Previously flooded this year, now dry. Light Blue: Flooded.
© 2012 Delmar, Cengage Learning Battery Service Chapter 27.
Automotive Batteries.
MElec-Ch3 - 1 Chapter 3 Direct Current Power Direct Current Power.
© Goodheart-Willcox Co., Inc. Permission granted to reproduce for educational use only Publisher The Goodheart-Willcox Co., Inc. Tinley Park, Illinois.
Battery Principles.
Battery Fundamentals Chapter 26.
BATTERY Intoduction An electrical battery is one or more electrochemical cells that convert stored chemical energyinto electrical energy. Since the invention.
THE AUTOMOTIVE BATTERY. What is the purpose of the battery in a car? Provide voltage and current for the starter motor Provide voltage and current for.
12month free replacement 36 month pro-rated warranty Starting at $49.99 exchange INSERT EXIDE AUTOMOTIVE FAMILY TRADE SHEET HERE EXIDE DRIVER’S EDGE AUTOMOTIVE.
Battery Technology November, range: function of energy density of the battery. Compare 12,000 (theo.) / 2600 Wh/kg with the lead-acid.
Operation Service Diagnosis
Produced By Mike Hartlen Automotive Battery THIS PRESENTATION ABOUT AUTOMOBILE SYSTEMS HAS BEEN DEVELOPED BY Mike Hartlen TEACHER OF AUTOMOTIVE TECHNOLOGY.
AE6PM Rechargeable_Battery_Basics 1 Rechargeable Battery Basics More than you ever wanted to know. Don Steinbach AE6PM Saratoga Amateur Radio Association.
Electrochemistry is the chemistry of reactions which involve electron transfer. In spontaneous reactions electrons are released with energy which can.
1 Battery Safety, Servicing & Testing R. Bortignon.
Selling Against Gel Technology Optima AGM has a wider operating temperature range than Gel. –High temperatures impact Gel’s life and performance more than.
BATTERY Teknik Kendaraan Ringan Semester 2nd Class X Kompetensi Kejuruan SK-KD 15 TH.
Inside a Fuel Cell The red Hs represent hydrogen molecules (H2) from a hydrogen storage tank. The orange H+ represents a hydrogen ion after its electron.
Batteries The purpose of the battery is to act as a reservoir for storing electricity.
Chapter 27 – Cells and Batteries
CONVENTIONAL, MAINTENANCE FREE, AND DEEP CYCLE/DRY CELL The Automotive Battery.
Battery Fundamentals Chapter 30 Page 403.
© 2011 Pearson Education, Inc. All Rights Reserved Automotive Technology, Fifth Edition James Halderman BATTERIES 50.
Service Training. CONSTRUCTION OF A BATTERY: Components.
CLASSES OF BATTERIES PRIMARY CELLS SECONDARY CELLS.
Odyssey Thin Plate Technology – The Advantages  Highest volumetric and gravimetric energy density  Increased shelf life (up to 2 20°C)  Extremely.
Additional Reactions of Significance Oxygen Reaction Cycle:: ½O 2 + Pb PbO PbO + H 2 SO 4 PbSO 4 + H 2 O Note: Oxygen reaction cycle is a benchmark characteristic.
Electrical Circuits. Electrical Circuit Closed path through which charge can flow A Circuit needs: 1.Source of energy (voltage) 2.Conductive path for.
Year 10 Chemistry. Getting Started You can make a simple electrical cell from a lemon, a think piece of copper wire and a trip of magnesium. 1.Clean the.
This flow chart is applicable to all types of lead acid batteries. This includes flooded, AGM / VRLA, Gel, etc. There are multiple battery chargers available.
ELECTRIC CURRENT. What is current electricity? Current Electricity - Flow of electrons What causes electrons to flow? When an electric force is applied,
ODYSSEY BATTERIES AGM Military Grade TPPL Technology.
HEAVY DUTY ELECTRICAL CBC. SIZE IS IMPORTANT! THE LARGER THE ENGINE, THE LARGER THE BATTERY NEEDED. ELECTRICAL SYSTEMS VITAL TO EQUIPMENT OPERATION.
IdleWATCH®II / NITE™ System o System Components o Basic Diagram o Key Features o Fleet Benefits o IdleWATCH®II Battery Models o On-Highway Applications.
CBC Automotive n Operation n Service n Diagnosis Battery.
Dale Roberts Sustainment Engineering Branch Defense Supply Center Richmond Defense Logistics Agency March 2005 Defense Logistics Agency Standardization.
Making a Voltaic Pile Generating Voltage: Creating energy for a cell cell.
Avoid _____________ _____________ _____________ _____________ _____________ _____________.
Evaluation of Battery Technologies to Replace KS Round Cells John Bailey, Quad Cities Senior Staff Engineer Objective: Present issue background.
50 BATTERIES BATTERIES.
PIMPRI CHINCHWAD POLYTECHNIC
Choose the Best Car Batteries for Your Car in UAE
Automotive Service Modern Auto Tech Study Guide Chapter 28 & 29
Batteries & Battery Charging. Welcome In this presentation we try to give you: An overview of lead acid batteries and how they work. An overview of Hawkins.
Chapter 31 Battery Systems.
STEEL PLATES.
© 2012 Delmar, Cengage Learning Battery Fundamentals Chapter 26.
Modern Automotive Technology PowerPoint for by Russell Krick
BATTERIES AND BATTERY CHARGING
Batteries and Fuses Topics covered in this presentation:
Automotive Technology Principles, Diagnosis, and Service
Fig. 2 Stabilizing the lithium-electrolyte interface.
Presentation transcript:

APPENDIX 2. Common Batteries, NSNs, and CCAs 6T Conventional Battery Design 6TMF – Flooded Type 6TL – Flooded Type 12V - 6TMF/TYPEII (for consignment) NSN 6140-01-446-9506 6T Flooded type Lead Calcium Plates 725 CCA 12V - 6TMF/TYPEI (Comes dry with over-packed electrolyte) NSN 6140-01-446-9498 12V - 6TL NSN 6140-01-446-9506 Used to have a separate NSN. Lead Calcium Plates Usually rated at 625 CCA

APPENDIX 2. Common Batteries, NSNs, and CCAs 6TAGM Battery Design These batteries are 6TAGM (VRLA) lead acid batteries. Though they may appear similar they also have different chemistry and capacities. EXIDE – 6TAGM NSN 6140-01-485-1472 Type: Flat Plate AGM CCA - 1100 HAWKER – 6TAGM NSN 6140-01-485-1472 Type: Flat Plate AGM Pure Lead Tin Plates CCA - 1225 FIAM – Batcore 6TAGM NSN 6140-15-180-0587 Type: Flat Plate AGM NSN is now invalid CCA - 1100

APPENDIX 2. Common Batteries, NSNs, and CCAs 2HN Flooded and AGM Battery Design These batteries are commonly found on power generation equipment, and various other types of support equipment. Both are authorized for use on equipment that require this size 12V battery 2 HN 2HN – Flooded Type Wet NSN: 6140-01-390-1969 Lead Antimony Plates CCA - 150 Optima Spiral Core AGM (VRLA) NSN 6140-01-529-7226 Pure Lead Tin Plates CCA - 450

APPENDIX 2. Common Batteries, NSNs, and CCAs 4HN Flooded and AGM Battery Design 4HN – Flooded Type AGM (VRLA) 4HN Replacements 4HN Flooded type NSN: 6140-01-390-1968 Lead Antimony Plates Concorde AGM NSN: 6140-01-476-8945 Type: Flat Plate AGM Lead Calcium Plates Teledyne/Gill AGM NSN: 6140-01-610-6102 Type: Flat Plate AGM Pure Lead Tin Plates 2 HN

APPENDIX 2. Common Batteries, NSNs, and CCAs Group 31 AGM (VRLA) Battery Design Exide Group 31 Type: Flat Plate AGM Automotive Terminals P/N 31A925XLW NSN 6140-01-582-5710 Used on the BFV CCA - 925 Optima Group 31 Type: AGM Spiral Cell Threaded Stud Terminals Pure Lead Tin PLates NSN 6140-01-457-5469 Used on 100&200KW, Skid Steer, etc. CCA - 900

APPENDIX 2. Common Batteries, NSNs, and CCAs Other VRLA AGM Battery Options Optima AGM Spiral Core NSN: 6140-01-378-8232 CCA - 800 Type: Spiral Cell AGM Pure Lead Tin PLates Shown With - 6T Adapter Plate NSN: 6160-01-453-0858 Used on Generators and other Support Equipment VRLA / AGM NSN: 6140-01-505-1940 CCA – 1125 Type: Flat Plate AGM Used on Engineer Equip VRLA / AGM Flat Plate NSN: 6140-01-556-4352 CCA – 785 Type: Flat Plate AGM Used on HMMWV power turrets

Other VRLA Spiral Cell AGM Battery Options. APPENDIX 2. Common Batteries, NSNs, and CCAs Other VRLA Spiral Cell AGM Battery Options. These batteries will have the CCAs listed on top. Model# Description NSN CCA Yellow Top - DUAL PURPOSE Deep Cycle & Engine Start Batteries D51 For Asian vehicles and specialty Mil equipment. 6140 01 523 6288 450 D51R Replacement for 2HN flooded. 6140 01 529 7226 D34 Group 34 size, top post only. Alternative to 34 Red Top. 6140 01 450 0141 750 D34/78 Group 34 size. Dual terminal, Top posts and side terminals. Alternative to 34/78 Red Top. 6140 01 441 4272 D31T Group 31 size battery for large commercial / engineer equipment. Threaded stud terminals. 6140 01 457 5469 900 D31A Group 31 size truck battery for commercial / engineer equipment. Automotive terminals. 6140 01 502 4973 Blue Top - DUAL PURPOSE Deep Cycle & Engine Start Batteries D34M Group 34 size battery for boats, cars, light trucks, etc. Also M777 Howitzer. 6140 01 475 9355 D31M Group 31 size battery for large commercial / engineer equipment & boats. 6140 01 502 4405 Red Top - ENGINE START Batteries 75/25 Smaller battery with both top posts and side terminals. 6140 01 475 9361 720 34 Group 34 size, top post only. Used on many vehicles, generators, pumps, etc. 6140 01 378 8232 800 34/78 Group 34 size. Dual terminal, Top posts and side terminals. 6140 01 374 2243 34R Group 34 size. Top post. Reversed terminals. 6140 01 475 9357 34VX Group 34 size. Same as 34/78 with extra added vibration resistance. Used in MRAP M-ATV. 6140 01 534 6466 ENGINE START - Blue Top Battery Terminals: automotive posts & 5/16" stainless steel threaded studs. 34M Group 34 size. Not for deep cycle use. 6140 01 526 2605

Cross Reference Matrix: Conventional Battery and AGM/VRLA Replacement APPENDIX 2. (Continued) Cross Reference Matrix: Conventional Battery and AGM/VRLA Replacement Voltage Rating Old Type Battery Flooded Lead Acid NSN New Sealed Type Battery Sealed Battery: AGM / VRLA NSN 12 6TMF-I - Dry 6140-01-446-9498 6TAGM (Hawker or Exide) 6140-01-485-1472 6TMF-II - Wet 6140-01-446-9506 6TMF-III - Dry 6140-01-469-9184 2HN - Dry 6140-00-057-2553 Optima D51R 6140-01-529-7226 2HN - Wet 6140-01-390-1969 2HN - GEL 6140-01-446-9554 24 4HN - Dry 6140-00-059-3528 Teledyne – Gill or Concorde Gill NSN: 6140-01-610-6102 Concorde NSN: 6140-01-610-6102 4HN - Wet 6140-01-390-1968 Generators and other equipment with 6T type Flooded or AGM batteries 6140-01-485-1472 and others Optima Red Top 34/78 6140-01-374-2243 - Requires adapter plate 6160-01-453-0858 when replacing 6TMF or 6TAGM. Optima Red Top 34 6140-01-378-8232 - Requires adapter plate 6160-01-453-0858 when replacing 6TMF or 6TAGM. Support equipment & commercial vehicles 6140-01-457-4348 Optima Red Top 34 or Yellow Top deep cycle 6140-01-378-8232 or 6140-01-450-0141 6140-01-457-4363 Optima D27M 6140 01 589 0622 Construction & engineer equipment 6140-01-031-6882 Optima D31A 6140 01 502 4973