2 © 2004, Cisco Systems, Inc. All rights reserved. IT Essentials I v. 3 Module 9 Advanced Hardware Fundamentals for Servers.

Slides:



Advertisements
Similar presentations
Storage Management Lecture 7.
Advertisements

A CASE FOR REDUNDANT ARRAYS OF INEXPENSIVE DISKS (RAID) D. A. Patterson, G. A. Gibson, R. H. Katz University of California, Berkeley.
By Rashid Khan Lesson 6-A Place for Everything: Storage Management.
RAID Oh yes Whats RAID? Redundant Array (of) Independent Disks. A scheme involving multiple disks which replicates data across multiple drives. Methods.
Preparing For Server Installation Instructor: Enoch E. Damson.
Enhanced Availability With RAID CC5493/7493. RAID Redundant Array of Independent Disks RAID is implemented to improve: –IO throughput (speed) and –Availability.
1 CSC 486/586 Network Storage. 2 Objectives Familiarization with network data storage technologies Understanding of RAID concepts and RAID levels Discuss.
R.A.I.D. Copyright © 2005 by James Hug Redundant Array of Independent (or Inexpensive) Disks.
Chapter 5: Server Hardware and Availability. Hardware Reliability and LAN The more reliable a component, the more expensive it is. Server hardware is.
REDUNDANT ARRAY OF INEXPENSIVE DISCS RAID. What is RAID ? RAID is an acronym for Redundant Array of Independent Drives (or Disks), also known as Redundant.
2.1 © 2004 Pearson Education, Inc. Exam Managing and Maintaining a Microsoft® Windows® Server 2003 Environment Lesson 2: Installing Windows Server.
1 Web Server Administration Chapter 3 Installing the Server.
Lesson 5-Accessing Networks. Overview Introduction to Windows XP Professional. Introduction to Novell Client. Introduction to Red Hat Linux workstation.
70-290: MCSE Guide to Managing a Microsoft Windows Server 2003 Environment Chapter 2: Managing Hardware Devices.
70-290: MCSE Guide to Managing a Microsoft Windows Server 2003 Environment Chapter 2: Managing Hardware Devices.
Chapter 3 Chapter 3: Server Hardware. Chapter 3 Learning Objectives n Describe the base system requirements for Windows NT 4.0 Server n Explain how to.
1 DOS with Windows 3.1 and 3.11 Operating Environments n Designed to allow applications to have a graphical interface DOS runs in the background as the.
Session 3 Windows Platform Dina Alkhoudari. Learning Objectives Understanding Server Storage Technologies Direct Attached Storage DAS Network-Attached.
Data Storage Willis Kim 14 May Types of storages Direct Attached Storage – storage hardware that connects to a single server Direct Attached Storage.
By : Nabeel Ahmed Superior University Grw Campus.
RAID Redundancy is the factor for development of RAID in server environments. This allows for backup of the data in the storage in the event of failure.
DAS Last Update Copyright Kenneth M. Chipps Ph.D. 1.
Troubleshooting Hardware Issues Lesson 5. Objectives 2.
XP Practical PC, 3e Chapter 17 1 Upgrading and Expanding your PC.
RAID Shuli Han COSC 573 Presentation.
LAN / WAN Business Proposal. What is a LAN or WAN? A LAN is a Local Area Network it usually connects all computers in one building or several building.
Redundant Array of Independent Disks
Day 10 Hardware Fault Tolerance RAID. High availability All servers should be on UPSs –2 Types Smart UPS –Serial cable connects from UPS to computer.
Module 9 Review Questions 1. The ability for a system to continue when a hardware failure occurs is A. Failure tolerance B. Hardware tolerance C. Fault.
GeoVision Solutions Storage Management & Backup. ๏ RAID - Redundant Array of Independent (or Inexpensive) Disks ๏ Combines multiple disk drives into a.
Chapter 2 Chapter 2: Planning for Server Hardware.
Chapter 19 Upgrading and Expanding Your PC. Getting Started FAQs: – Can I upgrade the processor in my PC? – Will adding RAM improve my PC’s performance?
70-290: MCSE Guide to Managing a Microsoft Windows Server 2003 Environment, Enhanced Chapter 2: Managing Hardware Devices.
CSI-09 COMMUNICATION TECHNOLOGY FAULT TOLERANCE AUTHOR: V.V. SUBRAHMANYAM.
Guide to Linux Installation and Administration, 2e 1 Chapter 9 Preparing for Emergencies.
Ch Review1 Review Chapter Microcomputer Systems Hardware, Software, and the Operating System.
Hands-On Microsoft Windows Server 2003 Administration Chapter 2 Managing Windows Server 2003 Hardware and Software.
Module 9: Configuring Storage
Server Systems Administration. Types of Servers Small Servers –Usually are PCs –Need a PC Server Operating System (SOS) such as Microsoft Windows Server,
4.1 © 2004 Pearson Education, Inc. Exam Managing and Maintaining a Microsoft® Windows® Server 2003 Environment Lesson 4: Organizing a Disk for Data.
1 Selecting LAN server (Week 3, Monday 9/8/2003) © Abdou Illia, Fall 2003.
Chapter 2 Chapter 2: Planning for Server Hardware.
Windows Server 2003 硬碟管理與磁碟機陣列 林寶森
Copyright © Curt Hill, RAID What every server wants!
11 INSTALLING AND MANAGING HARDWARE Chapter 6. Chapter 6: Installing and Managing Hardware2 INSTALLING AND MANAGING HARDWARE  Install hardware in a Microsoft.
The concept of RAID in Databases By Junaid Ali Siddiqui.
Chapter 9 Advanced Hardware Fundamentals for Servers.
RAID and RAS CIS 485 SAU SUJA SOLOMON TIFFANY STACIE.
Chapter 8: Installing Linux The Complete Guide To Linux System Administration.
Introduction TO Network Administration
PARTS OF A COMPUTER 2 Hardware Computer Hardware is any of the physical parts of the computer you can touch. There are 4 categories: 1. Input Devices.
Install, configure and test ICT Networks
Lesson 2 Component Overview Core Hardware Fundamentals.
1 CEG 2400 Fall 2012 Network Servers. 2 Network Servers Critical Network servers – Contain redundant components Power supplies Fans Memory CPU Hard Drives.
Hands-On Microsoft Windows Server 2008 Chapter 7 Configuring and Managing Data Storage.
This courseware is copyrighted © 2016 gtslearning. No part of this courseware or any training material supplied by gtslearning International Limited to.
RAID TECHNOLOGY RASHMI ACHARYA CSE(A) RG NO
Network-Attached Storage. Network-attached storage devices Attached to a local area network, generally an Ethernet-based network environment.
Chapter Objectives In this chapter, you will learn:
Multiple Platters.
Introduction to Computers
RAID RAID Mukesh N Tekwani
Web Server Administration
TECHNICAL SEMINAR PRESENTATION
Chapters 1-3 Concepts NT Server Capabilities
Chapter 2: Planning for Server Hardware
RAID RAID Mukesh N Tekwani April 23, 2019
Hard Drives & RAID PM Video 10:28
Storage Management Lecture 7.
Presentation transcript:

2 © 2004, Cisco Systems, Inc. All rights reserved. IT Essentials I v. 3 Module 9 Advanced Hardware Fundamentals for Servers

Module 9 Advanced Hardware Fundamentals for Servers 9.1 – Network Server Overview 9.2 – Hardware Based Raid Configuration 9.3 – Configuring External Peripherals 9.4 – Adding Hardware to a Server 9.5 – Upgrading Server Components

Network Server Overview

Network Server A network server is a computer system in a network that is shared by multiple users. Servers come in all sizes from x86-based PCs to IBM mainframes. The term "server" may refer to both the hardware and software (the entire computer system) or just the software that performs the service.

RAID Redundant Array of Inexpensive Disks (RAID) is designed to allow some fault tolerance to prevent loss of data in the event of a disk drive failure on a network server. Recently, the phrase “redundant array of independent disks” has become common, substituting the word “independent” for inexpensive. RAID accomplishes this fault tolerance or redundancy through disk drives storing parity or the same information to two different disk drives.

RAID RAID 0 is just an array (or group) of disk drives used as a single disk. The data is written in chunks or stripes to all the disk drives in the array. RAID 1 requires a minimum of two disk drives to implement. In disk mirroring, the two disk drives are connected to the same disk controller. To eliminate this single point of failure, use disk duplexing rather than disk mirroring.

RAID The problem with disk mirroring is that if the disk controller fails, there is no access to the mirrored data. RAID 2 uses a hamming code to create an Error Correcting Code (ECC) for all data to be stored on the RAID 2 array. RAID 3 uses bit-level parity with a single parity disk to provide fault tolerance of data stored on the RAID 3 array. RAID 4 uses block-level parity with a single parity disk to provide fault tolerance to the RAID 4 array.

RAID RAID 5 uses block-level parity, but spreads the parity information among all the disk drives in the disk array. The loss of storage capacity in RAID 5 systems is equivalent to the storage capacity of one of the disk drives. RAID 0/1 is also known as RAID 0+1 and it is sometimes called RAID 10.

RAID Controller RAID controllers are specialized disk controllers that use either ATA or SCSI technologies. RAID controllers often have an onboard memory cache ranging in size from 4 MB to 256 MB. The memory cache on the RAID controller can usually be configured as read cache, write cache, or a combination of both.

Hardware RAID Versus Software RAID RAID is usually implemented using a RAID disk controller and disk controllers are expensive. Software RAID is usually implemented at the disk partition level rather than the physical disk level as in hardware RAID. The drawback to software RAID is that it requires the network server processor to perform the work usually done by the RAID controller in hardware RAID. Software-based RAID does have one advantage over hardware-based RAID. In software-based RAID, the RAID implementation can be based on disk partitions rather than entire disk drives.

Hardware-Based RAID Configuration

Hardware-Based RAID Configuration Overview Network servers that contain a RAID controller must have the RAID system configured before the network operating system can be installed. Configuration of the RAID system consists of selecting actual physical disk drives and grouping them together into one of the available RAID configurations.

RAID 0 Configuration RAID 0 is known as disk striping. It is not fault tolerant, but it is used to improve disk input/output performance. It is often used in a high- powered workstation to improve disk input/output performance by reading and writing files in blocks to several disks simultaneously as opposed to reading and writing a file sequentially to a single disk drive.

RAID 1 Configuration RAID 1 has two different implementations: disk mirroring and disk duplexing. In disk mirroring, everything written to one disk is also written to a second disk. Disk duplexing eliminates the single point of failure that exists in disk mirroring.

RAID 5 Configuration RAID 5 requires a minimum of three disk drives to implement. The disk drives that comprise a RAID 5 solution are often referred to as a RAID 5 array. RAID 5 is more efficient than the other RAID levels in that the overhead is 1/n * 100, where n is the number of disk drives in the RAID 5 array.

RAID 0/1 Configuration RAID 0/1 (sometimes called RAID 0+1 or RAID 10) involves mirroring (or duplexing) two RAID 0 arrays. This yields the fault tolerance of RAID 1 and the input/output speed of RAID 0. RAID 0/1 requires a minimum of four disk drives to implement.

Configuring External Peripherals

Overview of External Disk Subs External disk subsystems are necessary when the amount of disk storage cannot be accommodated by the disk drive bays internal to the network server chassis. These external disk subsystems can be either SCSI or Fibre Channel. Generally, Fibre Channel–based systems can support many more disk drives than a SCSI-based external system.

Configuring an External Disk Subsystem External disk subsystems may consist of a single disk drive in its own chassis with its own power supply. On the high end, an external disk subsystem chassis might have 100 or more disk drives in it. The simple external disk subsystem with only a few disk drives might just be attached to the external port on a SCSI or RAID controller. Some large external disk subsystems may have their own RAID mechanism built right in. These large systems are often configured separately from the disk controller in the network server to which they will be attached.

Configuring an External CD-ROM System External CD-ROM systems are often referred to as a CD-ROM library. Imagine a tower chassis with 7, 14, 21, or more CD- ROM drives. Having these CD-ROM drives attached to a network server means that it is possible to share all these CD- ROM drives and the CD-ROMs that they contain with all users on the network.

Adding Hardware to a Server

Replacing a Single Processor with a Faster Processor The user has to determine whether a faster processor is available in a form factor that is compatible with the existing processor. Upgrading to a faster processor may also require upgrading the BIOS on the system board. Cover the seven steps needed to perform a single processor upgrade.

Installing Additional Processors To add another processor to a multiprocessor-capable network server, the new processor must meet the following criteria: –Be the same model processor as the existing processor –Have the same clock speed –Have the same Level 2 (L2) cache size –Match the stepping within one version (N+1) Here are sample outputs from the Windows and bootable floppy version of the Intel identification program.

Upgrading the Operating System for Multiple Processors If the original installation of Microsoft Windows NT Server 4 or Windows 2000 Server was on a network server with a single processor, the hardware abstraction layer (HAL) on the network server must be updated for the network server to recognize and use multiple processors. If the original installation of Novell NetWare 5 was on a network server with a single processor, several changes in the configuration of the Novell NetWare 5 server must be made for it to recognize and use multiple processors. For Red Hat Linux (and other versions of Linux) to recognize multiple processors, the Linux kernel must be rebuilt.

Adding Hard Drives Disk drive upgrades come in two varieties: adding disk drives to an existing network server, or replacing existing disk drives with larger or faster disk drives. Before attempting any disk drive upgrade, make absolutely sure that there is at least one, preferably two, verified full backups of the data on the disk drives.

Adding Memory Before adding memory to a network server, verify the current memory configuration. Determine whether the network server hardware can support the amount of memory desired in the network server. Memory modules may have a requirement to be installed in pairs or groups of four. Most network servers have SIMMs, DIMMs, or RIMMs.

Upgrading Server Components

Upgrading Adapter Memory Adapter upgrades also fall into several categories: upgrading components on the adapter, such a memory; upgrading the BIOS or firmware on the adapter; and replacing the adapter with a newer, faster, or more powerful adapter. The following adapters use onboard memory: –Video adapter onboard memory –SCSI adapter onboard memory –RAID controller onboard memory

Upgrading Adapter BIOS or Firmware Upgrading the BIOS or firmware on an adapter is similar to upgrading the system BIOS. The steps are vendor specific: 1.Locate the latest BIOS or firmware on the adapter vendor’s website 2.Download the BIOS or firmware upgrade and follow the vendor’s instructions to install the upgrade

Replacing an Adapter Adapters are generally replaced after they fail. The replacement procedure generally follows several simple steps: 1.Power down the network server 2.Remove the defective adapter 3.Install the new adapter 4.Power up the network server PCI hot plug (or PCI hot swap) enables the user to replace, upgrade, or add an adapter without powering down the network server. It has three capabilities: 1.Hot replacement 2.Hot upgrade 3.Hot expansion

Upgrading Peripheral Devices Peripheral devices can be either internal to the server chassis or external to the network server chassis. If the adapters are not plug-and-play, the user may have to configure the adapters with an interrupt request (IRQ), a direct memory access (DMA) channel, and input/output (I/O) address. External devices might be hot plug and plug-and-play compatible. Other external devices might require that the network server be shut down before they can be upgraded.

Upgrading System Monitoring Agents System monitoring agents are software specific to the network server itself. System monitoring agents monitor various aspects of the network server. The agents usually use standard protocols such as HTTP, SNMP, and DMI to report information to a management console.

Upgrading Service Tools Upgrading service tools is generally a software upgrade operation. These updated tools are generally available on either CD-ROMs supplied by the network server vendor or from the vendor’s website. Most service tools fall into the following general categories: –Diagnostic Tools –EISA Configuration Utility –Diagnostic Partition Utility –Server Support Utilities

Document the Configuration The reason good documentation is needed is so that if a problem occurs more than once the user can look up how to fix it and save himself/herself from doing the same failed method twice. This will in turn save the time fixing it and the user will be able to have the server back online much faster.