Introduction In recent years, harmonics are considered as one of the most essential problems in the industrial power distribution networks. The problem.

Slides:



Advertisements
Similar presentations
Copyright© Voltimum Experts – not to be reproduced without prior consent of Voltimum UK Voltimum Expert Topic – Power Harmonics.
Advertisements

Mike Thornton National Sales Manager
Ch8 Inverters (converting DC to AC)
EEEB443 Control & Drives Controlled Rectifier DC Drives By
QUALITY AND TECHNOLOGY
Chapter 4 DC to AC Conversion (INVERTER)
Power Quality during the late 90’s  PQ was dominated by Fluke and LEM  Power Utilities has just started talking about standards to be followed  National.
Power Quality & Energy Efficiency: A Solution to Climate Change 1 st POWER QUALITY ASIA CONFERENCE November 14 & 15, 2012 SMX Convention Center, Manila.
EMC in Electrical Power Systems Frithiof Jensen Power System Engineer November 12, 2013.
2010 ASHRAE Rocky Mountain Chapter VFD Fundamentals April 16, 2010 Jeff Miller - ABB © ABB Month DD, YYYY | Slide 1 1.
© Copyright 2008 ABB. All rights reserved /29/2008 Results-Driven Roadshow Cincinnati, 2008 Common Cures for Harmonics Larry Stanley RSE,Nashville,TN.
POWER ELECTRONICS Instructor: Eng.Moayed N. EL Mobaied The Islamic University of Gaza Faculty of Engineering Electrical Engineering Department بسم الله.
WATERLOO ELECTRICAL AND COMPUTER ENGINEERING 60s: Power Engineering 1 WATERLOO ELECTRICAL AND COMPUTER ENGINEERING 60s Power Engineering Department of.
Harmonic Studies A Year 2014 Approach
Textbook: Bin Wu, ‘High-Power Converters and AC Drives’, Wiley - IEEE Press, 2006 EE8407 Topic 6 1 Power Converter Systems Graduate Course EE8407 Ryerson.
Dry type transformers Zaragoza Traction application
groups.yahoo.com/group/435_1
Chapter 4 DC to AC Conversion (INVERTER)
Understanding of Harmonics in Power Distribution System
Fundamentals of Harmonics
 Distortion – the alteration of the original shape of a waveform.  Function of distortion analyzer: measuring the extent of distortion (the o/p differs.
Switch-Mode DC-AC Inverters
ISA Northern California Section, South Bay October 14, 2003 Craig Chidester
CLASS B AMPLIFIER 1. 2 In class B, the transistor is biased just off. The AC signal turns the transistor on. The transistor only conducts when it is turned.
Power Distribution Harmonics Case Study of 285-3F Chiller Plant Michael W. Harmon Principle Engineer Savannah River Nuclear Solutions, LLC Savannah River.
Numerical algorithms for power system protection Prof. dr. sc. Ante Marušić, doc. dr. sc. Juraj Havelka University of Zagreb Faculty of Electrical Engineering.
ET3380 Principles and Methods of Electric Power Conversion David Morrisson MS,MBA Week 1.
PQSynergy TM 2011 Harmonic Assessment of PEA North1, Chiangmai’s Customers in North Industrial Estate Chotepong Pongsriwat. M.Eng(EE) Chief of Power.
1 HARMONIC ANALYSIS OF SELECTED DG DEVICES Pradipta Kumar Tripathy, Durgesh P. Manjure, Dr. Elham B. Makram CLEMSON UNIVERSITY ELECTRIC POWER RESEARCH.
7154 VFD Presentation #2 May 2002 Paul Weingartner.
Applied Harmonics Control of Harmonics
Voltimum Expert Topic – Power Harmonics. What are Harmonics? They are waveforms with frequencies that are multiples of the fundamental frequency (Typically.
Power Electronics 2 (H5CPE2) Dr Christian Klumpner Power Electronics, Machines and Control Group School of Electrical and Electronic Engineering, UoN Tower.
Clemson University Electric Power Research Association CHANDANA BOMMAREDDY CLEMSON UNIVERSITY DG VOLTAGE CONTROL IN AN ISLANDING MODE OF OPERATION.
1 Power Quality EKT 451 CHAPTER 8. 2 Introduction Utilities transmit electricity over power lines into home as an alternating current (AC) wave. This.
Introduction  Utilities transmit electricity over power lines into home as an alternating current (AC) wave.  This is how power travels through wiring.
Chapter 2 Harmonics and Interharmonics Theory
Signal Analyzers. Introduction In the first 14 chapters we discussed measurement techniques in the time domain, that is, measurement of parameters that.
7/08/2002PP.AFD.07 Harmonic Quality1 of 49 Yaskawa Electric America Harmonic Currents, Voltages and Your Building Power System.
Understanding Harmonic Limits per IEEE
Diode rectifiers (uncontrolled rectifiers)
controlled rectifiers (Ac-dc converters)
Asea Brown Boveri Jumet S.A. FD 1/30 ASEA BROWN BOVERI Harmonic Problem ? Are Tuned Filters THE Solution ?
Mahesh M. Swamy Yaskawa America, Inc. PP.IEEE
A DSP based on on-line UPS R.Padamaja G.Mamatha Reddy EEE EEE S.V.C.E S.V.C.E BY.
Power Quality Issues Power Electronics Group.
Institute of Applied Microelectronics and Computer Engineering College of Computer Science and Electrical Engineering, University of Rostock Slide 1 Power.
REVIEW OF CFL AND ITS HARMONIC IMPACT ON ELECTRICAL DISTRIBUTION SYSTEM Guide: Mr. Rijo Rajan, prepared by: Merin Lukose Lecturer, S7 EEE EEE department.
Effects of Harmonics on Capacitors Electrical System
Switch-Mode DC-AC Inverters
HARMONIC MITIGATION USING PASSIVE FILTERS
Presented By Deepak Kumar Bari Regd. No
MEDIUM VOLTAGE APPLICATIONS.
Yaskawa Electric America on Variable Torque Loads
Analysis of the Amplitude and Frequencies of the Voltage Magnification Transients in Distribution Networks due to Capacitor Switching Mohamed Saied Electrical.
M.KARTHIK (10F41D4307) Under the esteemed guidance of
Harmonics can be reduced by using of line inductances (AC-chokes) or
Harmonic Distortion Analyzer, Wave Analyzer and Function Generator
AC to DC Converters Outline 2.1 Single-phase controlled rectifier
Power System Harmonics
Electromechanical Systems
ECE 333 Green Energy Systems
UNIT-8 INVERTERS 11/27/2018.
Fundamental Electrical Power Concepts
Power quality management for induction furnace foundry
SHUNT ACTIVE FILTER It is a voltage-source converter connected in shunt with the same ac line and acts as a current source to cancel current distortions,
Islamic University of Gaza
Equalizing Average Source Power with Pattern Swapping
Module V Wave Analyzers
Inverters Converting dc to ac
Presentation transcript:

Introduction In recent years, harmonics are considered as one of the most essential problems in the industrial power distribution networks. The problem of harmonics is increasing due to the use of the variable speed drives (VSDs), the uninterruptible power supplies (UPS), and the solid-state devices. Harmonics current distortion may produce negative effects on the power quality of the power networks. The negative effects include malfunctioning of sensitive devices such as protective relays, motors overheating, and transformer overheating. The current total harmonic distortion (THD) can be reduced to the IEEE standards using harmonics filters such as passive harmonic filters or active harmonic filters. Ahmad Hassan AlObaidly and Abdulaziz Abdulla Alshafai Supervisor: Dr. Khaled Ellithy Department of Electrical Engineering, College of Engineering FALL 2008 Objectives To conduct a study on harmonics, harmonics sources, harmonics representation, harmonics effects, and harmonics indices. To conduct a study on harmonics, harmonics sources, harmonics representation, harmonics effects, and harmonics indices. To study the recommended IEEE-519 standards for the current and voltage harmonics distortion. To study the recommended IEEE-519 standards for the current and voltage harmonics distortion. To conduct a study on the types of harmonics filters. To conduct a study on the types of harmonics filters. To conduct a study on passive harmonics filters design. To conduct a study on passive harmonics filters design. To perform the harmonics analysis and harmonics filter design for a typical gas plant power network using EDSA power system analysis software. To perform the harmonics analysis and harmonics filter design for a typical gas plant power network using EDSA power system analysis software. Computer Simulation Results with the Designed Harmonics Filters HR-5343 UPS-A %THD i =7.37% %THD i =2.98% The current total harmonic distortions (7.37% and 2.98%) are within the IEEE-519 standards. Conclusions Harmonics sources, harmonics effects and harmonics representation have been presented. Harmonics sources, harmonics effects and harmonics representation have been presented. An industrial power distribution network of a gas plant was chosen for the study. An industrial power distribution network of a gas plant was chosen for the study. Measurements of the current and voltage harmonics distortions at the Gas Plant were conducted using AEMC power quality analyzer. Measurements of the current and voltage harmonics distortions at the Gas Plant were conducted using AEMC power quality analyzer. The plant power distribution network for harmonics analysis was developed using EDSA power systems analysis software. The plant power distribution network for harmonics analysis was developed using EDSA power systems analysis software. The harmonics filters were designed to eliminate the dominant harmonics orders to reduce the THD of the current and voltage to the allowable limits recommended by the IEEE 519 standards. The harmonics filters were designed to eliminate the dominant harmonics orders to reduce the THD of the current and voltage to the allowable limits recommended by the IEEE 519 standards. The maximum limits of voltage and kVAR of the harmonics filter capacitor have been checked with the ANSI/IEEE 18 standards. The maximum limits of voltage and kVAR of the harmonics filter capacitor have been checked with the ANSI/IEEE 18 standards. Harmonics Indices and IEEE 510 Standards "Harmonics" term in an AC power system is defined as a sinusoidal component of a periodic waveform that has a frequency equal to an integer multiples of the fundamental frequency (50 Hz) of the power network. The Total harmonic distortion (THD) is a measure of the effective value of the harmonic components of a distorted waveform. Maximum harmonic current distortion in percentage of the fundamental V ≤ 69 kV TDD% % 35≤h23≤h≤3517≤h≤2311≤h<17h<11I SC / I L < >1000 Power Distribution Network Model for Harmonics Analysis of a Train in a Typical Gas Plant Computer Simulation Results without Harmonics Filters HR-5343 UPS-A %THD i = 42.55% %THD i = 41.38% %THD i = 42.55% %THD i = 41.38% The current total harmonic distortions (42.55% and 41.38%) exceed the IEEE-519 standards Harmonics Filter Design A passive harmonic filter is designed to eliminate the 11 th harmonic order for HR Passive harmonic filter to eliminate the 5th harmonic order for UPS-A The voltage and kVAR of the harmonics filter capacitor have been checked with limits recommended by ANSI/IEEE standards. Bus Voltage at PCC (KV) Individual harmonic voltage distortion (%) Total Voltage Distortion, THD (%) V < < V < V > IEEE 519 standard of current harmonicsdistortions IEEE 519 standard of current harmonics distortions IEEE 519 standard of voltage harmonics distortions IEEE 519 standard of voltage harmonics distortions The THD of voltage is given by The THD of current is given by Single-line diagram of power distribution network Including harmonics sources