Load Bank 負載測試器 RGR 高壓接地電阻器 What Is A Load Bank? Load Banks are devices designed to provide electrical loads for testing power sources such as for testing.

Slides:



Advertisements
Similar presentations
Denver Fire Alarm Test FUNDAMENTAL, POWER SUPPLIES, CIRCUITS, INSPECTIONS, TESTING and MAINTENANCE.
Advertisements

Effective Generator Testing & NFPA o Highlight key elements of NFPA 110 as it relates to generator testing o Describe diesel engine fundamentals.
Thermostats, Pressure Switches, and Other Electric Control Devices
Setup/Installation/Operation of an Environmental Control Unit (ECU)
TYPES OF MECHANICAL SYSTEMS
Exhaust Heat Recovery Systems
Uninterruptible Power Supply (UPS)
INTD 51 human environments building systems. heating/ventilation/air-conditioning (HVAC) maintain a comfortable indoor climate control temperature and.
Energy Efficient Steam Systems. Steam Systems Steam systems most widely used type of process heating Advantages of steam: –Heat carrying capacity of steam.
UL/FM Fire Pump Systems Lunch & Learn 04/18/05
The Load Bank of Choice
Emergency Lighting Code Review Presented by Iota Engineering LLC.
(Adapted from:D.T. Hall:Practical Marine Electrical Knowledge)
Jon Sunde – Master Electrician, Trystar
Monitoring Vibration on Tunnel Fans Safety First The worlds developing infrastructure creates many technical challenges for engineering and construction.
Harnessing Free Heat. The Energy Harness provides hot water using multiple heat sources, making the best use of low grade heat. It improves the efficiency.
Manufacture's Representative – Power Generation/Oil & Gas Covering TX, OK, LA, AK, in some cases NM and MS Extensive Power Gen Experience Extensive Docking.
One solution, many application Integrated Electronic Solution PowerSupply Flex.
During a mains supply interruption the entire protected network is dependent on the integrity of the UPS battery as a secondary source of energy. A potential.
UDC ZERO ENERGY VISTOR CENTER. System Components Solar Array –Primary Power Generator –Array consists of 12 BP SX3190B Solar Modules.
Fuel Oil Systems Fuel Oil Systems consist of: Storage Tanks Pumps
Steam Power Station Presented By Ashvin G. Patel Asst. Prof. (E.E.)
Fire Pump Functions The main function of a fire pump is to increase the pressure of the water that flows through it. Inadequate or nonexistent municipal.
PHY 202 (Blum)1 More basic electricity Non-Ideal meters, Power, Power supplies.
Operating and maintenance of generator. Operating Generator If it is manually operated generator, whenever power goes off, before starting the generator,
June 11, 2011 Littlerock Fire Station 7 pm. Power failures in past years Recent power failure of 2012 resulted in the required chlorination of our water.
Alaska Municipal League 59th Annual Local Government Conference The Programs of the Alaska Energy Authority Energy and Empowerment for Your Communities.
Management and Organisation of Electricity Use Electrical System Optimisation Belgrade November 2003.
8. Power in electric circuits R V I. Example: Two resistors, R 1 = 5 , R 2 = 10 , are connected in series. The battery has voltage of V = 12 V. a) Find.
Power Plant Construction and QA/QC Section 4.4 – In-Plant Electrical Distribution Engineering Technology Division.
CHP & DG METERING & MONITORING IN NEW YORK STATE CASE STUDIES AND IMPLEMENTATIONS Presented By: STEPHEN STONE, PE DSM ENGINEERING ASSOCIATES, PC
A Presentation On 132 KV GSS BEHROR
Teknologi Pusat Data 12 Data Center Site Infrastructure Tier Standard: Topology Ida Nurhaida, ST., MT. FASILKOM Teknik Informatika.
WELCOME!. Who is T&T Power Group? WELCOME! Who is T&T Power Group? What can we do for you?
International Facility Management Association (IFMA) Generator Systems Maintenance Combined Heat & Power (CHP) Technology.
Utilities & Engineering Department16 Blossom St., Boston Introduction to the Hospital Emergency Power Supply System (EPSS) Jason D'Antona,
I Need A Space Heating System Let’s Look At A Central Steam Plant Option.
HEAT-GENERATING EQUIPMENT INTRODUCTION SELECTION EFFICIENCY FURNACES BOILERS CENTRAL HVAC SYSTEMS.
HOUSE WIRING NOTES. Electricity  Proton – positive charge  Electron – Negative charge  Electricity = flow of electrons Conductor= electricity passes.
YOU’VE GOT THE POWER!. When the grid goes down, which type of system do you want for emergency power: battery or generator? Either type will get the job.
GENERATORS A Large Piece of Equipment That Gets Ignored!
Fuel cell is an electrochemical device converts the chemical energy taken from fuel to electrical energy.
Cooling System Get the engine up to optimum operating Temperature as quickly as possible and maintains it at that temperature. Controls the heat produced.
Austin Energy Elevated Requests for High Reliability Service South West Electric Distribution Exchange (SWEDE) May 8, 2015 David Tomczyszyn, P.E. – Distribution.
Module 11 -Cost Estimation This module covers how to estimate project costs including: –Equipment costs – combination of procurement and installation (including.
Irrigation Pumping Plants
Selecting Electric Motors
BRAND PRESENTATION.
Sub Station.
Uninterruptible Power Supply (UPS)
Exhaust Heat Recovery Systems
Auxiliary power supply (APS) Hossein Harimi 2014
SUB-STATIONS.
Section 6: Air-Conditioning (Heating And Humidification)
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
Special-Purpose Outlets— Electric Heating, Air Conditioning
7. Power in electric circuits
Shipboard Electrical Distribution
Trane Standby Generators
Mobile Cellular Communications System
AGENDA INTRODUCTION CELLS AND COMPONENTS PV PERFORMANCE
ENG421 (3c) – Pipes, Valves, Pumps
VITALITY Large Splits Johnson Controls PowerPoint Guidelines | July 21, 2009.
More and more power failures are being experienced through the Republic of South Africa. It is clear that this situation is not improving, nor will it.
AGENDA INTRODUCTION CELLS AND COMPONENTS PV PERFORMANCE
Door Heat Exchanger: Specification
Presented by Mike Zacharias
Presentation transcript:

Load Bank 負載測試器 RGR 高壓接地電阻器

What Is A Load Bank? Load Banks are devices designed to provide electrical loads for testing power sources such as for testing power sources such as Generators and Uninterruptible Power Supplies (UPS). (Dummy Load) Normal/Emergency Load s Load Bank

Why Are Load Banks Necessary? Maintain reliability of the Emergency Power System by testing of the engine generator (s) under load. by testing of the engine generator (s) under load.

Testing With A Load Bank Will Help Insure   

   That When You Have A Power Failure   

   Your Engine Generator Will Deliver The Power It Is Required To Do!

Recommended / Required Testing Of Engine Generators Frequency Duration Capacity Monthly 30 – 40 Minutes 50% to 60% of Engine Generator Rating  Annually 2 Hours 2 Hours 100% of Engine Generator Rating  (Resistance/Reactance) (Resistance/Reactance)

When it is unfeasible to apply actual load, it is recommended to use a Load Bank

Hospital & Health Care Facilities

NFPA Required Testing Of Engine Generators Hospital And Health Care Frequency Duration Capacity Monthly 30 Minutes 30 Minutes 50% of Nameplate Rating Of Engine Generator Annually 30 Minutes 30 Minutes 100% of Nameplate Rating Of Engine Generator  

Your Generator Is Only As Good As Your Last Full Load Test! AC Kilowatts Please Realize...

Assures proper KW, Voltage and Frequency AC Kilowatts Full Load Testing

Confirms the Reliability of components such as Fuel & Cooling Systems Full Load Testing

 Diesel…The Preferred Fuel For Standby  A Diesel Engine Generator Should Always Have At Least A 50 – 60% Load Connected While Running Or “Wet Stacking” Could Occur Another important reason to operate your standby generator under load…

“Wet Stacking”  Unburned Fuel Causes Carbon Build Up  Excessive Oil Consumption  Reduced Horsepower….Reduced Efficiency  Premature Failure

Wet Stacking Is Most Common... Applications With Varying Loads Engine Generators Sized For Pump Starting Currents All Pumps Running At One Time And

Wet Stacking Is Most Common...  Gen-Set Was Oversized For Future Growth Or Redundancy Or Redundancy Emergency Bus N + 1 Engine Generators

Types Of Load Banks  Radiator/Duct Mounted  Permanent/Free Standing  Portable

Portable Load Bank  Service & Rental Applications  Mounted On Casters  Fit Through Doorways & Elevators  Lightweight From 70KW To 500KW

Portable Load Banks From 70KW... Portable Load Banks From 70KW...

Portable Load Banks... To 500KW Portable Load Banks... To 500KW

Portable Load Bank  Trailer Mounted  Heavy Duty Dual Axle Trailers  Low Profile Horizontal Discharge (Up To 1000KW)  Vertical Discharge (1400KW TO 2100KW)  Optional Cable Reels From 1000KW To 2100KW

Portable Load Banks Trailer Mounted From 1000KW... Trailer Mounted From 1000KW...

Portable Load Banks Trailer Mounted... To 2100KW Trailer Mounted... To 2100KW

Portable Load Banks Portable Load Banks Facility FacilityNormal/Emergency Loads Tap Box Box Portable Portable Load Bank Portable Portable Engine Generator Synchronizing Gear Arranged For Spare Portable Engine Generator Portable Load Bank - Or -

Radiator Mounted Load Banks  Dedicated Engine Generator Sets  Typically 50-60% Of The Generator Rating

Radiator Mounted Load Banks From 15KW...

Radiator Mounted Load Banks... To 1000KW

Permanently Mounted Free-Standing Load Banks  Static Pressure May Be Too High For Radiator Mount  Multiple Generator / Use Applications

Permanently Mounted Free-Standing Load Banks Multiple Engine Generator Sets That Are Paralleled

Permanently Mounted Free-Standing Load Banks Facility FacilityNormal/Emergency Loads Load Bank Multiple Engine Generator Sets That Are Paralleled

Permanently Mounted Free-Standing Load Banks Multiple Use Engine Generator Sets and UPS

K Permanently Mounted Free-Standing Load Banks Facility Facility Normal/Emerge ncy Loads Load Bank Multiple Use Engine Generator Sets / UPS For UPS Test For UPS Test

Permanently Mounted Free-Standing Load Banks From 50 to 2000 KW...

Traditionally, Permanently Mounted Load Banks Discharge Horizontally

Horizontal Discharge is the most economical design to provide the best protection against all environments

When Installing a Permanently Mounted Free-Standing Load Bank Consider... When Installing a Permanently Mounted Free-Standing Load Bank Consider...  Free Air Space for Cooling Air & Hot Exhaust  Location Of Installation  1KW-hour = 3,413 BTU  1,000 KW – hour = 3.4 Million BTU

Permanently Mounted Free-Standing Load Banks...To 2000KW

For Applications KW  Heat Dissipates Vertically  Less Real Estate Required

Load Bank Controls Allows Step/Block Loading

Load Bank Controls Load Bank Controls Located on Load Bank

Load Bank Controls Load Bank Controls  Remotely  On Wall  In Paralleling Switchgear

Load Bank Controls Load Bank Controls In Engine Generator Paralleling Switchgear

Load Bank Controls Load Bank Controls Load Dump Circuit Load Dump Circuit Disconnects Load Bank When ATS Transfers To Emergency

Avtron Load Shed Control Supplement Actual Load To Attain;  50% To 60% Generator Rating Load Bank Actual 20% to 70% 30% Supplemental Load

Load Bank Controls Load Bank Controls Load Shedder Option Load Shedder Option Dynamic Facility Load Load Shedder Option Load Bank

Load Bank Controls Load Bank Controls Load Shedder Option Load Shedder Option Load Bank Load Facility Load EngineGeneratorDesiredLoading 50% to 60% Load Shedder Automatically Regulates Load Bank Load Bank + Facility Load = Desired Loading On Generator

What Gives Avtron It’s Premier Reputation? What Gives Avtron It’s Premier Reputation? Built To The Highest Standards Built To The Highest Standards

Built To The Highest Standards

Materials/Duty/Workmanship Aluminized Steel vs. Galvanized Steel Aluminized Steel vs. Galvanized Steel Galvanized Rated to 500° F Aluminized Rated to 1250° F What Gives Avtron It’s Premier Reputation?

 Stainless Steel Element Support Rods  Industrial Type Controls  Heavy Gauge Aluminized Steel  Helidyne Resistor Elements What Gives Avtron It’s Premier Reputation? What Gives Avtron It’s Premier Reputation? Material / Duty / Workmanship Material / Duty / Workmanship Heavy Duty DutyHeavy Heavy  CLF Type Overcurrent Protection  Differential Pressure Air Switches Enhanced Safety Safety Controls ControlsEnhanced Safety Safety Controls ControlsEnhanced Safety Safety Controls Controls

When Designing Reliability Into Your Emergency Power System Consider Avtron Load Banks