Field Experience Controlling a Dedicated Outdoor Air System (DOAS)

Slides:



Advertisements
Similar presentations
Chapter 3. HVAC Delivery Systems
Advertisements

1 Application of for Predicting Indoor Airflow and Thermal Comfort.
HVAC CONTROLS (See section 18.9)
TYPES OF MECHANICAL SYSTEMS
HVAC 101 The Basics of Heating, Ventilation and Air Conditioning
The Role of Controls for Indoor Air Quality Kent W. Peterson, PE, Fellow ASHRAE P2S Engineering, Inc. Mid Columbia ASHRAE Chapter.
1 Stanley A. Mumma, Ph.D., P.E. Prof. Emeritus, Architectural Engineering Penn State University, Univ. Park, PA Web:
Heat Recovery for Commercial Buildings
Components of HVAC System
HVAC: heating, ventilating, and air conditioning this is a thermostat: it sends signals to the heating/cooling system.
Heating and Air Conditioning I
Introduction Enthalpy Wheel
Chilled Beam Presentation
VAV DESIGN FOR IMPROVED INDOOR AIR QUALITY. “Air conditioning is the control of the humidity of air by either increasing or decreasing its moisture content.
Model predictive control for energy efficient cooling and dehumidification Tea Zakula Leslie Norford Peter Armstrong.
Stanley A. Mumma, Ph.D., P.E. Prof. Emeritus, Architectural Engineering PSU, Univ. Park, PA Web: Chilled Surfaces:
1 Condensation Control Experiences in an “historic” Building with Movable Sash ASHRAE Anaheim Seminar 53, 1/28/04 Stanley A. Mumma, Ph.D., P.E. Professor,
Ceiling Radiant Cooling Panels as a Viable Distributed Parallel Sensible Cooling Technology Christopher L. Conroy, E.I.T. L. D. Astorino Companies, Pittsburgh.
1 Meeting ASHRAE Fundamentals, Standard 55 & 62.1 with Chilled Beams Displacement Ventilation.
1 Decoupling the Building Latent and Sensible Loads Using 100% Outside Air Systems ASHRAE Chicago Seminar 39 January 24, 2006 Stanley A. Mumma, Ph.D.,
Industrial Ventilation - A major control measure Dr. AA, UTM.
The Air We Breathe - Indoor Air Quality and Natural Ventilation Dr Yuguo Li Associate Professor Department of Mechanical Engineering The University of.
Active beams versus VAV with Reheat Analysis of May 2013 ASHRAE Journal article Ken Loudermilk Vice President, Technology & Developement.
AIR CONDITIONING SYSTEMS 1. All Air Systems An all-Air System is defined as a system providing complete sensible and latent cooling capacity in the cold.
Refrigeration and Heat Pump Systems Refrigeration systems: To cool a refrigerated space or to maintain the temperature of a space below that of the surroundings.
Web Based BACnet Compatible Controls Applied to Emerging HVAC Technologies Stanley A. Mumma, Ph.D., P.E. Prof. Architectural Engineering Penn State University.
PSU Building Thermal and Mechanical Systems Laboratory Environment A/E Kurt M. Shank, M.S. & Stanley A. Mumma, Ph.D., P.E. College of Engineering Department.
1 Stanley A. Mumma, Ph.D., P.E. Professor Emeritus Penn State Univ. Park, PA Web: Active and Passive.
Air Side System Evaluation
Implementing Demand Controlled Ventilation to Meet ASHRAE Standard By Klas C. Haglid, P.E., R.A., CEM 1.
Conditioning of Moist Air
Lecture Objectives Discuss specific class of problems
Chapter 11: Space Air Diffusion Conditioned air is normally supplied to air outlets at velocities much higher than would be acceptable in the occupied.
Improved Precision Leading to Improved Energy Efficiency Edward Decker AE 790 – Intelligent Buildings June 6, 2006.
Direct Digital DBT, %RH, and Condensate Control for a DOAS-CRCP system ASHRAE Winter Meeting Symp. 3, Orlando-Feb. 6, 2005 Stanley A. Mumma, Ph.D., P.E.
Class Objectives Stress the importance of HVAC
A Trane Air Conditioning Clinic Psychrometry Air Conditioning Clinic TRG-TRC001-EN © American Standard Inc
OBTAINING QUALITY MILL PERFORMANCE Dan Miller
1 Stanley A. Mumma, Ph.D., P.E. Prof. Emeritus, Architectural Engineering Penn State University, Univ. Park, PA Web:
2003 ASHRAE Annual Meeting Kansas City Energy Conservation Benefits of a DOAS with Parallel Sensible Cooling by Ceiling Radiant Panels Jae-Weon Jeong Stanley.
1 Stanley A. Mumma, Ph.D., P.E. Prof. Emeritus, Architectural Engineering Penn State University, Univ. Park, PA 2014 Conference Presentation.
1 Stanley A. Mumma, Ph.D., P.E. Prof. Emeritus, Architectural Engineering Penn State University, Univ. Park, PA Web:
Achieving Dry Outside Air in an Energy-Efficient Manner PSU Building Thermal and Mechanical Systems Laboratory Environment A/E Stanley A. Mumma, Ph.D.,
Final Projects Grading criteria is posted on the course website Preliminary results are due Next Tuesday Final Project delivery on Monday Dec. 7 th –Final.
Introduction to Energy Management
Introduction to Energy Management. Week/Lesson 13 Control Strategies for Occupant Comfort.
Jesse A. Fisher Mechanical Option Spring 2005 Riverpark Corporate Center, Phase 1 Salt Lake City, Utah.
Hamot Women’s Hospital Erie, PA Michael Galleher Mechanical Option l AE-Senior Thesis l April 12, 2011 l Advisor Dr. Jelena Srebric.
ASHRAE Tech. Paper, Long Beach, CA. June 26,2007 Poster Session Presentation: Poster contents. Jae-Weon Jeong, PhD Assistant Professor. Texas A&M University-Kingsville.
THERMAL COMFORT.
Application of Ceiling Radiant Cooling in a University Environment ASHRAE Chicago Seminar 7, 1/26/03 Stanley A. Mumma, Ph.D., P.E. Professor, Architectural.
Alexander Radkoff Mechanical Option | Spring 2014 Advisor: Dr. Stephen Treado 123 Alpha Drive Pittsburgh, Pennsylvania
Objectives Propose residential system related final project –Compare VAV systems with DOAS systems.
Review Project 1 Define Project 2 Define parameters for Thermal Comfort and Air Quality analyses in CFD Lecture Objectives.
A New (Rational) Way To Condition Air (and Save Energy) AEE, Philadelphia February 18 th 2016 Andrew Mongar, President, AirGreen LLC.
HCB 3-Chap 19A: All-Air Systems_Single Zone 1 Chapter 19A: ALL-AIR SYSTEMS: SINGLE ZONE AND SINGLE DUCT Agami Reddy (July 2016) 1)Introduction and common.
Design & Analysis of Psychrometric Processes Various ways of Generating A Comfort… BY P M V Subbarao Associate Professor Mechanical Engineering Department.
Maria’s Restaurant Chapter 2 Section 9
Pros and Cons of operating a DOAS EW continuously
Presented by Harry C. Elinsky, Jr. Filtech, Inc.
Cheryl Hughes Regional Sales Manager October 6, 2015
HCB 3-Chap 19A: All-Air Systems_Single Zone
VAV DESIGN FOR IMPROVED INDOOR AIR QUALITY
FBE03: Building Construction & Science
Professor of Architectural Engineering College of Engineering
Objectives Finish with Heat exchangers
Refrigeration & Air conditioning
Maria’s Restaurant Chapter 2 Section 9
Presentation transcript:

Field Experience Controlling a Dedicated Outdoor Air System (DOAS) ASHRAE Denver Symp #2 June 26, 2005 Stanley A. Mumma, Ph.D., P.E., Prof. Jae-Weon Jeong, Ph.D., Instructor Department of Architectural Engineering Penn State University, @ Univ. Park, PA http://doas-radiant.psu.edu

Presentation outline DOAS and Test Site Defined Controlled Devices, Instrumentation, and Control The Why & How of Continual Performance Monitoring Measured Air Diffusion Performance Index (ADPI) of System: f (Effective Draft Temperature) Measured Thermal Comfort, PPD Conclusions

DOAS Defined for this presentation High Induction Diffuser 100% OA No Recirc. Cool/Dry Supply, CV DOAS Unit W/ Energy Recovery Building With Sensible and Latent cooling decoupled Parallel Sensible Cooling System

Parallel Terminal Systems DOAS air Induction Nozzle Sen Cooling Coil Room air Radiant Cooling Panels Chilled Beams Fan Coil Units When talking about integration of dedicated outdoor air systems with parallel terminal systems, as this symposium is based, I wanted to make it clear that we mean anything from fan coil units, small air handlers, unit ventilators in schools, or just unitary air conditioners. But the focus of this presentation will be dedicated to radiant cooling panels. Unitary ACs Air Handling Units

Building Site

An Inside View

Another inside view

FM1 T7 Controls DOAS Schematic

EW full Speed EW Off EW Modulate 196 168 140 112 84 28 140 168 196 112 84 56 Humidity ratio (grains/lb) EW full Speed wet EW Off dry EW Modulate

Continual Performance Monitoring—the Need Dr. J Woods reports that 5-10% of entire non industrial building stock has building related illnesses. And 10-25% of the Stock has sick building syndrome. These are facilities that began their life with no known problems, then degraded. Also, DOE reports that monitoring could save 0.45 Quads/yr of energy.

Categories of performance degradation Insufficient diagnostic and alarm tools for early warning of degradation. Management’s lack of awareness of the economic consequences. Management’s Indifference.

Avoiding Potential Degradation in a DOAS-Radiant System Compromised SA quantity: equipment problems, dirt, etc: FM 1 used to detect. Compromised building pressurization, (infiltration): FM 5 used to detect. Compromised supply air temperature: detect EW using T6-7-10, or CC T8. Condensation: Cond sensor to detect. Note: sensors color coded with next slide

FM1 T7 DOAS Schematic

ADPI achieved w/ the DOAS system For the test facility, the air flow rate was about 0.3 cfm/ft2, or about 30% of a VAV (at design). Some have expressed concern about satisfactory air motion. Experiments were performed in the winter, when convective action was not supplemented by the overhead cooling panels (no panel cooling). Even in the winter the space has a cooling load—so no convective impact from heating.

ADPI Defined An indication of the %of the locations in a space with a velocity of 70 fpm or less and an EDT between -3F and +2F. Effective Draft Temperature (EDT): q=(TL-TR)-0.07*(VL-30) Where q, EDT, °F TL, local mean air stream DBT, °F TR, average room DBT, °F VL, local mean air stream velocity, fpm

The mean velocity at the 35 stations ranged from 12 to 30 fpm (all below 70 fpm). The EDT for 34 of the 35 locations ranged from -3<q, EDT < +2. Therefore the ADPI was [34/35]*100=97%

ADPI conclusion DOAS can deliver exceptionally high ADPI’s; a very favorable finding!

Thermal Comfort Thermal comfort is a function of the following variables that influence metabolic heat transfer: Dry-bulb temperature (DBT), Relative humidity, Mean radiant temperature, Air movement, Metabolism, and Clothing worn by the occupants. Comfort, then, is almost completely a function of the space air distribution, provided there is sufficient heating or cooling to meet the thermal and humidity control requirements. (i.e. ADPI important).

Measuring Thermal Comfort: Thermal Comfort Meter

Thermal Comfort Test Results -0.01<PMV<+0.07 Where, PMV subjective scale: +3 hot +2 warm +1 slightly warm 0 neutral -1 slightly cool -2 cool -3 cold

Predicted Percent Dissatisfied (PPD)

Predicted Percent Dissatisfied (PPD) test results The PPD for the tests: 5.1%<PPD<5.4% That means almost 95% of the occupants were satisfied. ASHRAE’s accepted thermal comfort design guidelines permits PPD to be as high as 20%. Satisfying nearly 95% of the occupants is certainly far superior to the ASHRAE target of 80% satisfied .

Conclusions Dedicated outdoor air systems (DOAS), when properly designed and controlled, are capable of delivering very stable and comfortable environments (PPD = 5%). The authors have experienced no difficulties making the system and controls perform as designed/desired. Perhaps the keys to success are: the proper control of the enthalpy wheel, and the control of the cooling equipment to assure that the space latent loads are completely handled by the ventilation air.

Conclusions It has been demonstrated that good air motion is achieved (ADPI of 97%) with ventilation air flow alone (typically around 20-30% of that required for thermal control), It is not necessary to deliver large quantities of primary air to provide thermal comfort. As a result, there can be significant air movement energy savings when a CRCP hydronic parallel system is used to meet the balance of the space sensible load not met with the ventilation air.

Conclusions Finally, because of the ability of the DOAS to decouple the space latent control from the sensible control, space relative humidity levels are maintained at the desired design level.

Questions

Inherent problems with VAV Systems Poor air distribution. Poor humidity control. Poor acoustical properties. Poor use of plenum and mechanical shaft space. Serious control problems, particularly with tracking return fan systems. Poor energy transport medium, air. Poor resistance to the threat of biological and chemical terrorism, and Poor and unpredictable ventilation performance.

VAV problems solved with DOAS/Radiant Poor air distribution. Poor humidity control. Poor acoustical properties. Poor use of plenum and mechanical shaft space. Serious control problems, particularly with tracking return fan systems. Poor energy transport medium, air. Poor resistance to the threat of biological and chemical terrorism, and Poor and unpredictable ventilation performance.

Consequences of system degradation—Ref: Dr. Jim Woods 20% of US workers experiencing health related symptoms Another 20% of US workers are experiencing hampered performance 50% of US workers have lost confidence in management’s ability to deal with the situation. A major economic investment is needed to mitigate each problem and recover workers “goodwill”.

Computing Occupancy From Measured DCO2 Data Steady state vs transient computations. Why count people in light of ASHRAE Std. 62.1-2004? Floor component. Occupant component. Causes space CO2 concentration to change with occupancy. DCV made more difficult.

Computing Occupancy From Measured DCO2 Data Transient equation in difference form: Pep=(V*(N-N1)/Dt + SA*(N-Ci))/(G*1,000,000) where Pep = number of occupants V = the space air volume, ft3 N = the space CO2 concentration at the present time step, ppm N1= the space CO2 concentration one time step back, ppm Dt = the time step, min. SA = the supply airflow rate, scfm Ci = the CO2 concentration in the supply air, ppm G = the CO2 generation rate per person, scfm

Computing Occupancy From Measured DCO2 Data How well does it work? As long as the temperatures remain nearly steady, the accuracy is remarkably good (within 2 people for a 40 person space). But when the OA temperature drops, error is introduced in the CO2 measurements. When the SA flow is large (many people), the counts can be off by many people. For the test site, by about +5 people.

Measuring Thermal Comfort A thermal comfort meter can measure the influence the six variables. The instrument uses a heated ellipsoidal transducer designed to simulate the thermal pattern of a human being. It contains a surface temperature sensor, and a surface-heating element whose power is adjusted automatically by the thermal comfort meter to bring the surface to a temperature similar to that of a thermally comfortable human. The rate of heat production needed to attain this temperature is used as a measure of the environmental conditions.