SQXF Instrumentation wires and connectors
Instrumentation & Quench heaters wires March 2014 J.C. Perez2 Instrumentation wires: AXON reference HH2619 LH Conductor diameter mm (0.15 mm 2 ) Conductor composition: Copper silver plated External wire diameter: 0.95 mm Wire insulation: polyimide tape wrapped (glued with a thin layer of fluoopolymer) Nominal voltage : 1000V AC Axon voltage test: (2*U N )+1000V= 3 kV Approx. price: 2220 €/km Quench heaters wires: AXON reference H 1619 L Conductor diameter 1.5 mm (1.34 mm 2 ) Conductor composition: Copper silver plated External wire diameter: 1.8 mm Wire insulation: polyimide tape wrapped (glued with a thin layer of fluoropolymer) Nominal voltage : 600V AC Axon voltage test: (2*U N )+1000V= 2.2 kV Approx. price: 4500 €/km
From Vladimir Ivanovich Datskov “Today I tested quench heater white wire with CLIQ pulse current at SM18. With CLIQ Cbox1 (C=28 mF) I did total 10 current pulses 387 A, 770 A and 1 kA via Q-heater wire 1 m long (R=12.9 mOhm). After 387 A pulse the wire temperature was not changed, only after 1 kA pulse the temperature was C.” March 2014 J.C. Perez3
SM18 cryostats connectors March 2014 J.C. Perez4 Burndy, 40 pins connectors for Vtaps and QH 3M, 40 pins connectors using twisted pairs of wires for strain gauges