Fiber Mesh Diagnostic (FMD) for Transverse profile measurements Project Status Report April 26, 2012 BNL ATF Users Meeting G. Andonian, R. Agustsson, A.

Slides:



Advertisements
Similar presentations
Design and Experimental Considerations for Multi-stage Laser Driven Particle Accelerator at 1μm Driving Wavelength Y.Y. Lin( 林元堯), A.C. Chiang (蔣安忠), Y.C.
Advertisements

Wakefield Acceleration in Dielectric Structures J.B. Rosenzweig UCLA Dept. of Physics and Astronomy The Physics and Applications of High Brightness Electron.
Quartz Plate Calorimeter Prototype Ugur Akgun The University of Iowa APS April 2006 Meeting Dallas, Texas.
Pepperpot Emittance Measurements of the FETS Ion Source
ATF2 Interaction Point Beam Size Monitor (Shintake Monitor) Status T. Yamanaka, M. Oroku, Y. Yamaguchi, S. Komamiya ( Univ. of Tokyo ), T. Suehara, Y.
Sub-femtosecond bunch length diagnostic ATF Users Meeting April 26, 2012 Gerard Andonian, A. Murokh, J. Rosenzweig, P. Musumeci, E. Hemsing, D. Xiang,
W. Clarida, HCAL Meeting, Fermilab Oct. 06 Quartz Plate Calorimeter Prototype Geant4 Simulation Progress W. Clarida The University of Iowa.
Optical Diagnostics T. Tsang, BNL, March 17, 2006 tight environment high radiation area non-serviceable area passive components optics only, no active.
Tight environment high radiation area non-serviceable area passive components optics only, no active electronics transmit image through flexible fiber.
Photon Source and Tagger Richard Jones, University of Connecticut GlueX Detector ReviewOctober 20-22, 2004, Newport News presented by GlueX Tagged Beam.
R. M. Bionta SLAC November 14, 2005 UCRL-PRES-XXXXXX LCLS Beam-Based Undulator K Measurements Workshop Use of FEL Off-Axis Zone Plate.
UCLA-ATF Chicane Compressor Experiment A. Murokh UCLA Department of Physics and Astronomy.
Ultra-sensitive HALO monitor N. Vinogradov, A. Dychkant, P. Piot.
experimental platform
Searching for Quantum LOVE at the Australian Synchrotron Light Source Eugene Tan On behalf of Rohan Dowd 120/10/2010Eugene Tan – IWLC 2010, Genega ASLS.
B W Kennedy, CCLRC Rutherford Appleton Laboratory VPTs for the CMS experiment B W Kennedy CCLRC Rutherford Appleton Laboratory St Petersburg, 26 April.
Status of EIC Calorimeter R&D at BNL EIC Detector R&D Committee Meeting January 13, 2014 S.Boose, J.Haggerty, E.Kistenev, E,Mannel, S.Stoll, C.Woody PHENIX.
CMS Week, CERN, 2002 R M Brown - RAL 1 Performance Characteristics of Production VPTs R M Brown, B W Kennedy, P R Hobson (with crucial input from D J A.
A Reconstruction Algorithm for a RICH detector for CLAS12 Ahmed El Alaoui RICH Workchop, Jefferson Lab, newport News, VA November th 2011.
Liquid scintillator for an off-axis neutrino detector? (The Minnesota group) We are actively investigating a liquid scintillator option for the off-axis.
Experimental set-up Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE Multi-Channel MCP PMTs S.Korpar a,b, R.Dolenec.
Detector development and physics studies in high energy physics experiments Shashikant Dugad Department of High Energy Physics Review, 3-9 Jan 2008.
Status of Hybrid target R&D at KEK-LINAC T.Takahashi Hiroshima University LCWS/ILC10 Beijing Collaborators: V. Strakhovenko O. Dadoun, R. Chehab, A.Variola,
~ gun3.9 GHz cavity Bunch compressor 3 ILC cryomodules 45 deg. spectro injector main linac user area disp. area transport line Overview of.
THE FORWARD PROTON DETECTOR AT DZERO Gilvan Alves Lafex/CBPF 1) MOTIVATION 2) DETECTOR OPTIONS 3) FPD R&D 4) OUTLOOK Lishep 98 Lafex/CBPF Feb 17, 1998.
The Tungsten-Scintillating Fiber Accordion Electromagnetic Calorimeter for the sPHENIX Detector Craig Woody, for the PHENIX Collaboration Physics Department,
High Dose Irradiation of Possible FCAL Sensors at the S-DALINAC Ch.Grah Physics and Detector Meeting DESY HH,
T. Sugitate / Hiroshima / PHX031 / Nov.01 The Photon Spectrometer for RHIC and beyond PbWO 4 Crystal Density 8.29 g/cm 3 Radiation length 0.89 cm Moliere.
Development of a Gamma-Ray Beam Profile Monitor for the High-Intensity Gamma-Ray Source Thomas Regier, Department of Physics and Engineering Physics University.
A Transverse Profile Imager for SwissFEL Rasmus Ischebeck.
G5 Beam Instrumentation D. Gassner, E. Pozdeyev 4-09.
Tests of AWAKE spectrometer screen and camera at PHIN Introduction Layout Procedure Setup, results (runs 1 – 5) Conclusions L. Deacon, S. Mazzoni, B. Biskup.
Multi-colour sctintillator-based ion beam profiler James Green, Oliver Ettlinger, David Neely (CLF / STFC) 2 nd Ion diagnostic workshop June 7-8 th.
APS April Meeting Detector Construction of the Forward Proton Detector at D0 Michael Strang University of Texas at Arlington Diffractive Events FPD.
Tests of spectrometer screens Introduction Layout Procedure Results Conclusions L. Deacon, B. Biskup, S. Mazzoni, M.Wing et. al. AWAKE collaboration meeting,
Slide 1 5th LHC RADIATION WORKSHOP, CERN, , Jochen Kuhnhenn, Fraunhofer INT Radiation tolerant fibres for LHC controls and communications.
E. A. Albayrak, HCAL Meeting, Fermilab, Nov HE CALORIMETER DETECTOR UPGRADE R&D STATUS E. A. Albayrak for The University Of Iowa Fairfield University.
Photon Source and Tagger Richard Jones, University of Connecticut GlueX Detector ReviewOctober 20-22, 2004, Newport News presented by GlueX Tagged Beam.
FSC Status and Plans Pavel Semenov IHEP, Protvino on behalf of the IHEP PANDA group PANDA Russia workshop, ITEP 27 April 2010.
Multi-OTR Status A.Faus-Golfe, J.Alabau, C.Blanch, J.V.Civera, J.J.García Garrigós IFIC (CSIC-UV) D.McCormick, G.White, J. Cruz SLAC aand KEK team.
“Attoscope”- Sub-femtosecond bunch length diagnostic
El-Mul Technologies Ltd – Confidential & Proprietary El-Mul Technologies El-Mul Technologies Ltd – Confidential & Proprietary Prof. Eli Cheifetz, Chairman.
1. Efficient trigger for many B decay topologies Muon System CALORIMETERS PRS + ECAL+ HCAL RICH1 VERTEX LOCATOR Efficient PID Good decay time resolution.
Electron Spectrometer: Status July 14 Simon Jolly, Lawrence Deacon 1 st July 2014.
Gamma Detector of Plastic Scintillator Oct. 2, 2009 IP-BSM Group 1.
ALICE setup: update on the installation 18/10/2010 Angela Intermite.
Tested: 15 types of LEDs (blue, green); quartz fibers with core diameters of 300µm and 50µm. Proposal: Blue LEDs rather than green: + : larger signal,
Beam Profile Monitor for Spot-Scanning System Yoshimasa YUASA.
Upgrade of the MEG liquid xenon calorimeter with VUV-light sensitive large area SiPMs Kei Ieki for the MEG-II collaboration 1 II.
XFEL Beam Dynamics Meeting Bolko Beutner, DESY First results of micro-bunching and COTR experiments at FLASH Bolko Beutner, Winfried Decking,
SL_THOMSON C. Vaccarezza on behalf of the SL_Thomson team.
Study of the cryogenic THGEM-GPM for the readout of scintillation light from liquid argon Xie Wenqing( 谢文庆 ), Fu Yidong( 付逸冬 ), Li Yulan( 李玉兰 ) Department.
Study of the Radiation Damage of Hamamatsu Silicon Photo Multipliers Wander Baldini Istituto Nazionale di Fisica Nucleare and Universita’ degli Studi di.
ODR Diagnostics for Hadron Colliders Tanaji Sen APC.
The New CHOD detector for the NA62 experiment at CERN S
Dielectric Wakefield R&D programme at Daresbury Lab.
Electron Beam Diagnostics at REGAE
Slice Parameter Measurements at the SwissFEL Injector Test Facility
Pepperpot Emittance Measurements of the FETS Ion Source
Diagnostics for ThomX Nicolas HUBERT, Marie LABAT, Moussa EL-AJJOURI, D. PEDEAU, Synchrotron SOLEIL Iryna CHAIKOVSKA, N. DELERUE, LAL.
KM2A Electron Detector Optimization
WP11: electron and proton beam testing
WG2 Summary: Diagnostics, measurements, and commissioning
F. Villa Laboratori Nazionali di Frascati - LNF On behalf of Sparc_lab
Proton Beam Diagnostics
Radiation tolerant fibres for LHC controls and communications
Advanced Research Electron Accelerator Laboratory
Transverse coherence and polarization measurement of 131 nm coherent femtosecond pulses from a seeded FEL J. Schwenke, E. Mansten, F. Lindau, N. Cutic,
Linac Diagnostics Commissioning Experience
Diagnostics overview Beam profile monitors Cherenkov radiators Summary
Presentation transcript:

Fiber Mesh Diagnostic (FMD) for Transverse profile measurements Project Status Report April 26, 2012 BNL ATF Users Meeting G. Andonian, R. Agustsson, A. Murokh, J. Rosenzweig, M. Rueals, R. Tikhoplav, S. Wu, RadiaBeam Technologies

Outline Motivation Status Report – Fabrication Fiber feed-through, bundling Detector – Experiment at UCLA Measurement at BNL ATF

Motivation Facilities require better resolution on beam transverse profile – Current techniques require scintillating materials or OTR – Resolution limited to <30µm, Require imaging optics Blooming, limited depth-of-focus, etc. – COTR can contaminate data for compressed bunches Exploit advances in fiber industry, nano-fabrication techniques Fibers mesh laid across beam path – Cerenkov radiation is collected/analyzed Fiber-mesh diagnostic (FMD) – adequate photon yield – minimal real-estate – FOV is arbitrarily large – Sub-10µm resolution With appropriate fiber choice

Angular Acceptance and yield Typical fibers n~1.5 –  c ~47 o – Angular acceptance peaked at  c – Rotation of fibers can increase/decrease acceptance Photon yield – N ph ~10 5 Cerenkov radiation from single e - Avg Photon flux per e - Total Photon yield

Radiation dose on fiber Background radiation (analytic) – ATF parameters Dose ~0.7kGy per shot – For 1 hr operation Dose ~100MGy Crosstalk (simulations) – Monte Carlo (GEANT4) – SiO 2 fibers – No significant crosstalk for up to 1mm – Avg. dose = 1.37x10 -6 Gy per e - – Total dose ~ 2kGy per shot FMD is viable in lab environment Energy deposited by single e - Dose rate per shot per area 100µm thick fiber (left) and 1mm thick fiber (right). Red lines are e - trajectories.

Fiber selection Resolution – core <10µm – Cladding 125µm (industry standard) – Coating removed Chemical content – Doping (low OH preferred) – Improved transmission – Life expectancy (F-doped) Irradiation expt results – Fujikura rad-resistant fibers 50µm core, 125µm cladding – Sterigenics (San Diego, CA) Exposures from 10kGy-1MGy – 3 wavelengths tested 658nm (blue curve) 808nm (red curve) 1313nm (green curve) Fiber losses vs wavelength D. Griscom Fiber Irradiation results

Detector Linear CCD` – Pixel size~10µm Adjacent pixels stay dark (cladding ~125µm) – Reduce crosstalk Fiber preparation – Fiber coatings must be stripped – Fiber ends polishing – Epoxy adhesive Single fiber detectors considered, but costly – PMTs – Used for POC test at UCLA Typical linear CCD responsivity Coupling scheme renderings

Individual fiber POC experiment UCLA Pegasus lab – Oct 2011 – Tested single fibers – Single mode (8.6um ID) – Multi mode (50um ID) – Goal 1: Measure Cerenkov angle – Goal 2: Test rotary stages and actuators assembly and DAQ Diagnostic – Dual photomultiplier tubes – PMTs in bunker, use 15m of fiber optic to transmit signal to control room – CCD imaging to measure rotation Beam Parameters – Q = 30pC – Energy = 5 MeV – Emittance = 1 um – Measurement after the dipole bend – Good agreement with theoretical predications

Fiber Holder

Preliminary Experimental Results Cerenkov Angle observed 4 ports (2 SM, 2 MM) Reasonable gain on PMT Limitations Charge cutoff by geometry at ~45 deg New holder design Camera placement constraint Repeat single measurement with upgrades Energy calibration of PMT

Fabrication Issues Fiber holder – Fiber core 8.6µm, cladding 125µm – Need ~10µm shift – Need 12+ layers – Careful Assembly techniques – Both x and y axes Coupling out of UHV to CCD board – Feedthrough Precision angular alignment of holders – Tip/tilt stage

Fiber holder and bundling Assembly procedure – Special assembly jig – Spacing a b c d Rendering Holder Holder with 2 (x12) layers of fibers

Fiber feed-through Investigated “tentacle” feedthroughs on large chambers from vendors – Up to 50 per “cube” – custom and costly In-house solution more viable – Good for 5E-8 Torr UHV – Leak rate <10E ” hole diameter optimal for Fujikura fibers 8E-8 Torr after 19h for holder 5E-8 Torr after 22h for blank CCD (fiber coupled)- Wilco imaging

Conclusions FMD has potential for high-res diagnostic Milestones – Irradiation results – Fabrication procedures (engineering) – POC experiment at UCLA – Vacuum levels 5E-8 – DAQ (CCD array is leading candidate, PMT array too costly) Competitive to present profile measurements – ATF has long history of testing beam profile monitors For ATF study – Assembly of 1 dimension (8x10 layer) fibers – DAQ issues ironed out in POC test – Goal 1: Compare to YAG screen (or OTR) – Goal 2: Measure lifetime of fibers – Timeline: Installation Late 2012 (~1 week for install, ~1 week for testing) Move to 2 dimensions (x and y) in 2013