8/10/20151 THE BASICS OF INFRATECH HEATER CONTROLS.

Slides:



Advertisements
Similar presentations
ELECTRICAL RECEPTACLES
Advertisements

Trystar Generator Docking Stations & Portable Power Cable
Chapter 29 Electrical Plans. Chapter 29 Electrical Plans.
Basic Electricity.
AC Coupled Systems Growing market segment Can be confusing! Can be complicated! Numerous ways to go MidNite has taken most of the mystique out of the.
SWITCHES, FUSES, & CIRCUIT BREAKERS
“Enerpak” Units » Propeller Type Fan » Size 100 – 400 MBH » 80% Thermal Efficiency » Natural or LP Gas » 10 Year Warranty on Heat Exchanger, Burners,
PYROCON12 De-Ice controller Technician Operation Presentation 2013.
Thermostats, Pressure Switches, and Other Electric Control Devices
Setup/Installation/Operation of an Environmental Control Unit (ECU)
AC-SSC-1 Installation and operation manual
Air-Conditioning Control Systems
ELECTRICAL SYSTEMS 21.3.
Switching Device Product Line General Duty and Heavy Duty Safety Switches.
| 1 © 2013 Universal Lighting Technologies ULT Marketing LED Product Capabilities.
What is a circuit? A set of connected electrical components that provide one or more complete paths for the movement of charges. A set of connected electrical.
EET Survey of Electronics
© 2012 Rinnai America Corporation Rinnai Circ-Logic (RCL)
Electrical Power Systems
© 2011 Ericson Manufacturing, Willoughby, Ohio
The Vanjen Group • Manufacture's Representative – Power Generation/Oil & Gas • Covering TX, OK, LA, AK, in some cases NM and MS • Extensive.
Manufacture's Representative – Power Generation/Oil & Gas Covering TX, OK, LA, AK, in some cases NM and MS Extensive Power Gen Experience Extensive Docking.
PYROCON12 De-Ice controller User Operation Presentation 2013.
Foundations of Physics
Ultima® X Series Gas Monitors
Panels and Subpanels. Main Service Panel aka Load Center The Load Center is the heart and soul of a home’s electrical system. It: – Serves as a distribution.
Off-Grid Power Using Enphase Micro-Inverters Off-grid inverter systems, using batteries, can be used to provide AC power when the grid is down. It is possible.
LUMEN ALARM & LIGHTING SYSTEM Artem Aginskiy, Grayson Carr, Yinuo James Chen, Andrew McDowell.
Residential/Office Intercom Systems HI-TECH SOLUTIONS FOR TODAY’S HOME /OFFICE COMMUNICATION NEEDS BROUGHT TO YOU BY:
Pages  In this PowerPoint, write down everything that is RED!!
INTRUSION ALARM TECHNOLOGY
Duralife By. Adding value to homes and lifestyles since 1962.
SuperSleuth Wise. Marketing and Sales Presentation/Training.  Complete video surveillance system in the palm of your hand.  Proven video motion Detection.
Charge Controllers Regulating Battery Charging.
Zoning Hydronic Systems. Zone Control Divides the Space to be Heated 1.Each with its own heating needs and control systems 2.There are several reasons.
ELECTRICAL SYSTEMS. Chapter Twenty One: Electrical Systems  21.1 Series Circuits  21.2 Parallel Circuits  21.3 Electrical Power.
What is a circuit? A set of connected electrical components that provide one or more complete paths for the movement of charges. A set of connected electrical.
Auto turn off battery charger Auto turn off battery charger.
Special Purpose Electrical Switches W. C.”Buster Hounshell Spring 2002.
Switches and Over Current Protective Devices Class Instructor ALPHER E. DE VERA, uap.
Special Purpose Electrical Switches W. C.”Buster Hounshell Spring 2002.
Unit 7, Chapter 20 CPO Science Foundations of Physics.
TECHNOLOGIES ESO 4 UNIT 1: ELECTRICITY AND ELECTRONICS ANALOGIC ELECTRONICS (PART 1)
Electricity. TYPES OF CIRCUITS Individual electrical circuits normally combine one or more resistance or load devices. The design of the automotive electrical.
UTH-65A VER. CAUTIONS ! PLEASE USE THE OUTLET PREPARED BY A QUALIFIED SERVICEMAN AND MUST CONFIRM IT BEFORE APPLY[SING AN ELECTRIC CURRENT.
© OUP: To be used solely in purchaser’s school or college Connecting circuits Circuits and current Circuits and energy Circuits summary 7J Electrical circuits.
Asahi/America Electric Actuators
Electronics Circuits.
User Operation Presentation
Sub Station.
ELECTRICAL RECEPTACLES
ELECTRICAL RECEPTACLES
C1300 advanced circular chart recorder
Section 6: Air-Conditioning (Heating And Humidification)
Asahi/America Electric Actuators Series 94.
Special Purpose Electrical Switches
De-Ice control devices
Asahi/America Electric Actuators
Chapter 19 Electrical Plans.
Residential/Office Intercom Systems
Technician Operation Presentation
Asahi/America Electric Actuators Series 94.
Telephone Entry and Digital Dial Systems
Universal Interrupted Electronic Oil Primary R7184U Training Module
Chapter Twenty One: Electrical Systems
Dominion Energy South Carolina: Solar Equipment Requirements
Presentation transcript:

8/10/20151 THE BASICS OF INFRATECH HEATER CONTROLS

8/10/20152 Infratech Patio Heater Controls Disclaimer The materials found within this presentation are not intended to provide all the information needed to purchase or install Infratech Patio Heaters. Please see installation guide and manual. We strongly recommend using a licensed electrical contractor for installation. PLEASE CHECK LOCAL BUILDING CODES AND RESTRICTIONS PRIOR TO PURCHASE. Please verify voltage of installation especially whether 240v, 208v, 277v, 480v and specify when ordering.

8/10/20153 Infratech Heater Basics  Although available in 110v, primarily use 240v or 208v  Provides safe infrared radiant heat for Indoor or Outdoor applications.  Not as affected by wind as many heaters.  Utilizes quartz technology which omits no visible light, rather than others on the market that cast an orange glow that many find unappealing.  Available in a wide variety of sizes, single or double element, which allows the perfect heater options for every patio.  Very small clearance from combustible materials is needed, also Flush Mount Kit available for in ceiling mounts or new construction.  Provides a “SOFT”, controllable heat.  Stainless Steel, Beige and Custom colors (slight up charge) with a variety of mounting options are available.

8/10/20154 Infratech Control Options  Infratech Heaters can be controlled by 3 different ways. Each has its’ unique features and benefits. They are: 1. Simple Switch-similar to a light switch you would use in your home (provided by installer). 2. “Value Control”- which is our part number INF10 & INF20 (15 amps maximum). 3. Custom Controls which are used to control multiple Infratech Heaters with full adjustability.

Infratech Control Option #1: Simple Switch PROS  Least Expensive Option  Easy Installation CONS  Lack of Control (only On or Off)  Switches do have limits to Amps  Separate Wiring each Heater 8/10/20155 The simplest way to control an Infratech heater is a wall switch. Please note that all switches are manufactured based upon amps that are needed. Your local electrical supply house can insure you have the right switch for the job. A popular option with a simple switch is to purchase a dual bulb heater and have two switches or a Duplex Switch controlling one heater. This will allow you to operate it at 50% or 100% which works well in many homeowner applications.

Infratech Control Option #2: Value INF Control PROS  Inexpensive Option  Easy Installation  Single or Double Boxes  Can use as many Boxes as needed  Flush or Wall Mounted CONS  Heat goes ON and OFF based on setting  Limited to 15 AMPS per INF  Limited to 3,000 Watt Heater  Must wire every heater separately from panel 8/10/20156 The INF control is a great option if you want turn down capability of your Infratech Heater. The INF control operates heater at full capacity with it cycling on and off based upon the level you dial… HI being on full time. Heater clicks on and off if set on other than HI, and thus regulates heat.

Infratech Control Option #3 : Custom Controls PROS  Allows heater output to be adjusted to desired level.  Unlimited amount of heaters controlled.  Remote Analog Control uses only 110v, with low voltage wire going to custom control Main Panel.  Can add a 60 minute rotary timer.  Can attach to EMS or other sophisticated system  Requires only one set of wires to Main Panel from Electrical Source. CONS  Costs more than other options.  Relays can control a max. of 40 amps (three 3,000w, two 4,000w, etc.) 8/10/20157  Custom controls are the “ultimate” option for Commercial and complex Residential Installations. Using these Solid State Controls allows you to adjust radiant energy intensity from zero to 100%.

8/10/20158 Infratech Control #3 Custom Controls It uses two key components being: Main Control Panel which provides a main secondary breaker point for all heaters and individual breakers for each heater zone, zone control capability Remote Analog Controls which may be mounted in any location convenient to the heaters. Many commercial applications put these at waiters station, bar, etc.

8/10/20159 Infratech Custom Main Panel Housing  UL Certified Housing We start with the highest quality casing (Nema 412) which is water proof and dust proof. To that we custom size and install heat sinks to insure components are not subject to excessive heat. All housings come standard with lock with master electricity shut off switch when door opens also available. Each Custom Control housing is UL Certified with a unique UL number assigned to each housing.

8/10/ Infratech Custom Main Panel Internal Key Components  Terminal Block This is the main junction for electricity coming into Control Housing and the distribution to Relays within housing.  Solid State Relay Takes electricity coming into the Control Housing and allows it to be adjusted for control set at the Remote Analog Control.  Circuit Breaker This halts electrical current in the event the circuit is broken or interrupted. Power comes into circuit breaker from relay and then is wired to heater, amount of electricity controlled by setting on Remote Analog Control.

Infratech Custom Main Panel Internal Key Components  Controller Strip This is the connection between the Custom Control the Remote Analog Controls.  Wiring Diagram Every Custom Control comes with a complete Diagram of the wiring for the controls.  UL Label Every Custom Control is UL listed and approved with its’ own unique number and certification. 8/10/201511

Infratech Custom Controls Additional Information  Each Relay can control up to 9000 watts or 40 amps of continuous power (four 2,000w, three 3,000w or two 4,000w heaters) with unlimited configurations.  Unlimited amount of relays based upon needs.  Remote Analog Controls can be mounted in any convenient location. Power for remote can come from any 120v source. A signal is transmitted to the relays in the main control panel using low voltage wiring. A single Analog Control can affect up to a maximum of four relays in the Main Panel. A 60 minute timer can be incorporated into Analog Controls. Panel can be managed by your EMS systems control. Normal lead time on Custom Controls is 2-3 weeks. 8/10/201512

Infratech Heaters from AEI  AEI has been in the patio heating business since  AEI has deep inventory of all Infratech heaters with same day shipping of 97% non custom heaters and or custom controls.  AEI has factory trained customer service representatives that can help design the perfect solution to heat almost any patio.  AEI stands behind our Infratech heaters with parts and service. 8/10/201513