1 Detector position August 2005, supplement May’06 sub- detectormean Zdelta ZZ_startZ_end TT First pillar =1 st shelf at sides clearance51 inner tracker T outer tracker T clearance11 2 nd shelf in middle total 8069 only shelf clearance10 inner tracker T2 +MFD envelope 8290 at level of RASNIK outer tracker T clearance 40 Second pillar = 3 rd shelf clearance25 inner tracker T outer tracker T Extra pillar RICH29450
2 RASNIK position on C-frame pillar the edge of C-Frame left right C-Frame x=-56.6x=+33.4x=+134.6x= x=0 y=0 beam (S2)172(S3) 83 y= /2= cable goes out from mask horizontally ( not rotated by 120º )
CCD on shelves pillar the edge of C-Frame C-Frame y= y=0 beam Cameras for C-frame nd shelf nd shelf rd shelf Cameras for C-frame 1st pillar 1 2 2nd pillar 3 4 2nd pillar 5 6 3
4 CRYOGENICS Z AXIS (BEAM) INSIDE PICTURE LONG STATION 1 C-FRAME PLANE 1 SHORT OT1 LONG STATION 1 C-FRAME PLANE 2 SHORT LONG STATION 3 C-FRAME PLANE 5 SHORT OT3 LONG STATION 3 C-FRAME PLANE 6 SHORT DV - 120um MASK, reversed holder IN FRONT OF C-FRAME DX - 340um MASK, reversed holder IN FRONT OF C-FRAME H I - 340um MASK, HOLDER BEHIND C-FRAME LONG STATION 2 C-FRAME PLANE 3 SHORT OT2 LONG STATION 2 C-FRAME PLANE 4 SHORT B - 340um MASK- HOLDER BEHIND C-FRAME E - 30um MASK + long H. + lens on the same C-FRAME F - 85um MASK + short H. + lens on the same C-FRAME LENS
5 convention for masks installation on table level - top view ~185 L ong C-Frame nd left pillar 1 st left pillar S hort C-Frame Outer +5 2 nd right pillar 1 st right pillar Inner - 120µm mask H3 B3 H3 B3 D H1 B1 F I2 B2 H13 B123 D E F I2 – lens type E magnet - 30 / 85µm mask + lens - reversed holders - 340µm mask RICH2 Z X T1-Q13-XU T1-Q13-VX T2-Q13-XU T2-Q13-VX T3-Q13-XU T3-Q13-VX T1-Q02-XU T1-Q02-VX T2-Q02-XU T2-Q02-VX T3-Q02-XU T3-Q02-VX D
6 Shelves Location & different kindNumber of lines on shelf Number of shelves on table, under rails82 42 on 1 st pillar24 on 2 nd pillar44 long vertical lines on bunker12 TOTAL This picture for 2 nd pillars BEAM IS TILTED, use shelves with identical thickness => No up-down symmetry in choice of holes for 2 nd & 3 rd station, Upper raw for 2 nd station, Lower raw for 3 rd station.
7 Shelves on 1 st pillar Use identical, short shelves => up-down symmetry, lines only in outside raw. Shelves are adjustable in x and y by +/- 10mm
8 Fixing shelf in the middle bottom vs OT2 or OT OT 5 th C-Frame OT 6 th C-Frame IT shelf / level of table surface -3140= Lens fixed CCD adjustable in z with range e b a line of sight in IT adjustable in x & y (A,B) 10 (C,D) 28 0 A +5 D Lines lengthened by reversing mask holder and lens holder C – to see full 9*9 segment on any mask D – to increase depth of focus B mask +5 C Z Z
lens + mask’s holder on C-frames – OT1 OT 1 st C-Frame 4 A=38 OT 2 nd C-Frame 4 A= STOP 16 4 ENVELOPE 100 END OF MASK AT END OF ENVELOPE ADJUSTMENT +- 5 A=38 or 27 4, ,5 +-5 or 21+4,5 +-5
LONG VERTICAL LINES TO THE BRIDGE lens mask x z y CCD Two lines measure displacement of the bridge in horizontal directions x & z wi th precision of a few microns vertical ( y 1mm) not used 6.7m 1.7m +margins 2m
11 Tool for adjusting shelf to C-frame This tool helps: 1)make runners on shelf perpendicular to one C-frame (in x-z plane and in y-z plane) 2)adjust (in x and in y) shelf to hole in one C-frame for every shelf on nearest C-frame in hole without mask holder |(2 nd C-frame)-(far end of 1 st new middle shelf)|-5= =501 500 x y Then adjust shelf versus cylinder z y Pillar (on sides) front view side view C-frame stop mechanism ON First install cylinder