Ahmad Aqel Ifseisi Assistant Professor of Analytical Chemistry College of Science, Department of Chemistry King Saud University P.O. Box 2455 Riyadh 11451.

Slides:



Advertisements
Similar presentations
FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
Advertisements

427 PHC. Direct-Current Plasma  A direct-current plasma (DCP) is created by an electrical discharge between two electrodes. A plasma support gas is necessary,
Spectroscopy Lecture 4 Ahmad Razali Bin Ishak Department of Environmental Health Faculty of Health Sciences UiTM Puncak Alam.
Elemental Spectroscopy ICP-OES
1 Atomic Absorption Spectroscopy Atomic Emission Spectroscopy Lecture 18.
Chapter 10 ATOMIC EMISSION SPECTROMETRY
AAS and FES (Ch 10, 7th e, WMDS)
Atomic Emission Spectroscopy
Inductively Coupled Plasma Mass Spectrometry or ICP-MS
Flame Ionization Detector Most common detector Carbon atoms (C-C bonds) are burned in a hydrogen flame. A small portion of carbon atoms are ionized (about.
AAS and FES (Ch 9, 7th e, WMDS)
AA and Atomic Fluorescence Spectroscopy Chapter 9
Atomic Spectroscopy Atomic Spectroscopic Methods Covered in Ch 313: Optical Atomic Spectrometry (Ch 8-10) Atomic X-ray Spectrometry (Ch 12) Atomic Mass.
INTRODUCTION TO OPTICAL METHODS
Atomic Absorption Spectrometry Dr AKM Shafiqul Islam University Malaysia Perlis.
1 Atomic Absorption Spectroscopy. 2 Atomic Transitions: Excitation and Emission.
Flame photometry.
Molecular Fluorescence Spectroscopy
427 PHC. Introduction  Spectrometric methods are a large group of analytical methods that are based on atomic and molecular spectroscopy.  Spectroscopy.
Atomic Emission Spectroscopy
427 PHC.  Atomic emission spectroscopy (AES) is based upon emission of electromagnetic radiation by atoms.
Ahmad Aqel Ifseisi Assistant Professor of Analytical Chemistry College of Science, Department of Chemistry King Saud University P.O. Box 2455 Riyadh
Ahmad Aqel Ifseisi Assistant Professor of Analytical Chemistry College of Science, Department of Chemistry King Saud University P.O. Box 2455 Riyadh
Atomic Emission Spectroscopy (AES)
Instrumental Chemistry Chapter 11 Atomic Mass Spectrometry.
Atomic Emission - AES M* → M + hn Thermal excitation M → M*
Atomic spectra are a result of energy level diagrams - quantum theory.
ATOMIC EMISSION SPECTROMETRY Chap 10 Sections: Sections: 10A 10A 10A-1 10A-1 10A-3 (skim) 10A-3 (skim) 10A-4 10A-4.
Fluorescence. Topics Sensitivity (nM-pM) –Contrast UV-vis measurements Derivatization Laser-Induced Fluorescence.
Spectroscopy Chapter 7.
Fluorescence. Topics Definition Instrumentation Sensitivity (nM-pM) –Contrast UV-vis measurements Derivatization Laser-induced Fluorescence.
Atomic Absorption Spectroscopy Elemental analysis Dissolved metals Source –Hallow Cathode Lamp –Cathode of specific element Sample –Acetylene-air flame,
ATOMIC ABSORPTION SPECTROSCOPY
BC ILN Atomic Absorption Spectroscopy (AAS) 1 Thompson Rivers University.
Field Methods XRF Copyright © 2013 by DBS. Atomic Spectroscopy for Metal Analysis Introduction to the Principles of Atomic Spectroscopy Atomic spectroscopy:
Chapter 8 An Introduction to Optical Atomic Spectroscopy
What Are Some Types of Spectroscopy ?
Atomic Emission Spectroscopy
Atomic Emission Spectrometry
Atomic Absorption Spectrophotometer
Chapter 10 Atomic Emission Spectrometry
1.1 Inductively coupled plasma (ICP) Three Argon flow 1.Plasma gas (10-20 L/min) 2.Nebulizer gas (~1L/min) 3.Optional auxiliary gas (~0.5L/min) Radio-frequency.
Atomic Absorption Spectrometry
Atomic Emission Spectrometry By: Alexa Kunch
1 Atomic Emission Spectroscopy Lecture Advantages of Plasma Sources 1.No oxide formation as a result of two factors including Very high temperature.
1 Atomic Absorption Spectroscopy Lecture Performance Characteristics of Electrothermal Atomizers Electrothermal atomization is the technique of.
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 20
Atomic spectroscopy Elemental composition Atoms have a number of excited energy levels accessible by visible-UV optical methods ä Must have atoms (break.
1 Introduction to Atomic Spectroscopy Atomic Absorption Spectroscopy Lecture 12.
Adv. Inst. Techs.  flame emission (eg flame photometer) known as low temperature emission ( K) ◦ first form of spectroscopy ◦ used in commercial.
Atomic Fluorescence Spectroscopy. Background l First significant research by Wineforder and Vickers in 1964 as an analytical technique l Used for element.
Chapter 4 Atomic absorption and emission spectrometry
Atomic-absorption spectroscopy
A TOMIC - ABSORPTION SPECTROSCOPY. Atomic absorption spectroscopy (AAS) is a technique for determining the concentration of a particular metal element.
Plasma A Plasma consists of a collection of free-moving electrons and ions and is very hot. Energy must be continually applied to sustain the plasma.
Atomic-absorption spectroscopy Lab3 Atomic-absorption spectroscopy.
Chapter 10 Atomic Emission Spectrometry
A TOMIC - ABSORPTION SPECTROSCOPY Lab no. 3 Done by : Iman Al Ajeyan.
Chem. 133 – 4/4 Lecture. Announcements I Strike – If the strike occurs, it will affect classes April 14 th and 18 th (unless ended early) – Lab: would.
Chem. 133 – 4/12 Lecture. Announcements I Strike – No Strike now planned Exam 2: – Average was 77 (range 61 to 93) Last HW Set (Set 3 – see handout) Lab.
Chemistry 4631 Instrumental Analysis Lecture 18 Chem 4631.
Chapter 28 Atomic Spectroscopy.
Chem. 133 – 4/4 Lecture.
Flame Emission Spectrometry
Spectroscopy Chapter 7.
Elemental composition
Instrumental Chemistry
Chapter 8 An Introduction to Optical Atomic Spectroscopy
FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
Inductively Coupled Plasma
Presentation transcript:

Ahmad Aqel Ifseisi Assistant Professor of Analytical Chemistry College of Science, Department of Chemistry King Saud University P.O. Box 2455 Riyadh Saudi Arabia Building: 05, Office: AA53 Tel , Fax: Web site: Atomic Emission Spectroscopy

Processes leading to atoms, molecules, and ions with continuous sample introduction into a plasma or flame. The solution sample is converted into a spray by the nebulizer. The high temperature of the flame or plasma causes the solvent to evaporate leaving dry aerosol particles. Further heating volatilizes the particles producing atomic, molecular, and ionic species. These species are often in equilibrium at least in localized regions. Atomization Process

Several methods that are used to atomize samples for atomic spectroscopy. Inductively coupled plasmas, flames and electrothermal atomizers are the most widely used atomization methods. Flames and electrothermal atomizers are found in atomic absorption spectrometry, while the inductively coupled plasma is used in optical emission and in atomic mass spectrometry. Atomization MethodTypical Atomization Temperature, o C Types of Spectroscopy Inductively coupled plasma 6000–8000-Emission -Mass Flame1700–3150-Absorption -Emission -Fluorescence Electrothermal1200–3000-Absorption -Fluorescence Direct-current plasma5000–10,000-Emission Electric arc3000–8000-Emission Electric sparkVaries with time and position-Emission Classification of Atomic Spectroscopic Methods

Flame Sources Both atomic and molecular emission and absorption can be measured when a sample is atomized in a flame. A sample of a material (analyte) is brought into the flame as either a gas, sprayed solution, or directly inserted into the flame by use of a small loop of wire, usually platinum. The heat from the flame evaporates the solvent and breaks chemical bonds to create free atoms. The thermal energy also excites the atoms into excited electronic states that subsequently emit light when they return to the ground electronic state. Each element emits light at a characteristic wavelength, which is dispersed by a grating or prism and detected in the spectrometer. A frequent application of the emission measurement with the flame is the regulation of alkali metals for pharmaceutical analytics.

Plasma Sources A plasma consists of a hot, partially ionized gas, containing an abundant concentration of cations and electrons that make the plasma a conductor. The plasmas used in atomic emission are formed by ionizing a flowing stream of argon, producing argon ions and electrons. The high temperatures in a plasma result from resistive heating that develops due to the movement of the electrons and argon ions. Because plasmas operate at much higher temperatures than flames, they provide better atomization and more highly populated excited states. Besides neutral atoms, the higher temperatures of a plasma also produce ions of the analyte.

Inductively Coupled Plasma (ICP) A schematic drawing of an inductively coupled plasma source The source consists of three concentric quartz tubes through which streams of argon flow at a total rate of between 11 and 17 L/min. Surrounding the top of the largest tube is a coil powered by a radio- frequency generator. Ionization of the flowing argon is initiated by a spark from a Tesla coil. The resulting ions and their associated electrons then interact with the fluctuating magnetic field (labeled H) produced by the induction coil (labeled I). This interaction causes the ions and electrons within the coil to flow in the closed annular paths. The resistance of the ions and electrons to this flow of charge causes ohmic heating of the plasma (6000 to 8000 K) at a height of 15–20 mm above the coil, where emission is usually measured.

Multielemental Analysis Atomic emission spectroscopy is ideally suited for multielemental analysis because all analytes in a sample are excited simultaneously. A scanning monochromator can be programmed to move rapidly to an analyte’s desired wavelength, pausing to record its emission intensity before moving to the next analyte’s wavelength. Another approach to multielemental analysis is to use a multichannel instrument that allows for the simultaneous monitoring of many analytes. A simple design for a multichannel spectrometer consists of a standard diffraction grating and 48–60 separate exit slits and detectors positioned in a semicircular array around the diffraction grating at positions corresponding to the desired wavelengths. Schematic diagram of a multichannel atomic emission spectrometer, showing the arrangement of multiple exit slits and detectors for the simultaneous analysis of several elements.

Instrumentation for atomic emission spectroscopy is similar in design to that used for atomic absorption. In fact, most flame atomic absorption spectrometers are easily adapted for use as flame atomic emission spectrometers by turning off the hollow cathode lamp and monitoring the difference between the intensity of radiation emitted when aspirating the sample and that emitted when aspirating a blank. Many atomic emission spectrometers, however, are dedicated instruments designed to take advantage of features unique to atomic emission, including the use of plasmas, arcs, sparks, and lasers, as atomization and excitation sources and have an enhanced capability for multielemental analysis. Instrumentation

Difference between Atomic Absorption and Atomic Emission (Animation)