Engine Types and Uses.

Slides:



Advertisements
Similar presentations
Strategy and Tactics with Limited Staffing
Advertisements

Natural Cover Fires. view from the west View looking west at the Head of the Fire.
Central Arizona Brush Fire Preparedness Part 3
NFPA 1142 Pre-burn Plans - House Layout - Fireground Layout - Hazard Mitigation - Permits Minimum Total Gals Required Minimum GPM For Flow Minimum Total.
Wildland/Urban Interface Structure Protection
Introduction to Truck 3 Pierce 105’ Aerial
Water supply and drafting. Objectives Understand and be able to demonstrate the different hydrant lays and hook ups Explain/demonstrate how to operate.
LoneStar Fire Specialties
Fire Pump Theory TCFP Section Part 3 Operations.
SKIDGINES PUMPER CATS SOFT TRACKS. AFTERMARKET EQUIPMENT CERTIFICATION.
Pumping Apparatus Driver/Operator
Presented by: Blaine W. Rabe’ Division Manager for the Property Insurance Association of Louisiana.
1 Math Questions. 2 Length x Width x Water Depth = cubic feet.
HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE TRAINING FACILITY.
Fire Apparatus Familiarization
Pumping Apparatus Driver/Operator
Purpose of Standpipe and Hose Systems
1402 Hybrid Firefighter I 6 th Edition Chapter 14 Water Supply.
C L A S #4 Driver Operator Refresher Training.
FIRE DEPARTMENT ORGANIZATION State of Georgia BASIC FIRE FIGHTER TRAINING COURSE.
Unit 2 Firefighter Preparedness. Unit 2.A - Personal Preparedness Lesson A – Personal preparedness: (FH P76) –Develop a list of personal gear needed.
Types of Fire Apparatus
Fire vs. Water Flow. What’s the best size for an “attack line?”  Maximum flow  Maximum mobility  Speed-How fast and how much  Ease of deployment and.
Intermediate SFFMA Objectives: – Hrs received.
Liquid Fuel Safety Cummins Southern Plains, Ltd..
Learning Objective 1 Explain the ways water supply system components are used by firefighters.
By: Lori. Firefighters do many things. They always fight fires. Firefighters use fire engine to use their hoses. Firefighters make sure the hoses screw.
WILDLAND ENGINE OPERATIONS PART 3 - Exercises WARDEN AND DEPUTY FOREST FIRE WARDEN TRAINING 2008.
Instructor Lee Lautzenheiser
Presents Project Crimson March 1, 2006 Sarah Grace Cade Harrelson Cochrane Jamison Libby Probst Justin Williams.
CHAPTER 9 Copyright © 2007 Thomson Delmar Learning 9.1 Water Supply.
MODULE:3 FIRE CONFINMENT AND EXTINGUISHMENT. OBJECTIVES Module 3 Select and deploy the appropriate hose lines to accomplish fire confinement and extinguishment.
1 Mrs. Brewster Nitza chinchillas Period Group Number Date
CVFD Training – Ground Cover Firefighting
FIRST DUE STREETS & ROADS VENTILATION.
Fire Service Pump Operator ch 02 Types of Fire Apparatus
Fire Fighting Module 1 Fire Suppression Operations  Battalion Chief Brett Bowman  Captain Jim Forgo.
MODULE:3 FIRE CONFINMENT AND EXTINGUISHMENT. OBJECTIVES Module 3 Overview Select and deploy the appropriate hose lines to accomplish fire confinement.
Fire Department Structure and Procedure
CHAPTER 2 Copyright © 2007 Thomson Delmar Learning 2.1 Fire Department Organization, Command, and Control.
Needs Analysis Full-Time Staffing Levels Michael A. Walker, Fire Chief.
20 Wildland and Ground Fires. 2 The Wildland Fire Triangle 20.
Mahoney, Hannig, Fire Department Hydraulics, 2nd Ed. ©2009 by Pearson Education, Inc., Upper Saddle River, NJ Fire Department Hydraulics Chapter 8 Required.
SCENERIO Hour fire weather forecast for: Monday, April 20 th, 2009 Dry weather will continue to hold over the area today Fire activity will remain.
WELL DRILLING AND CONSTRUCTION Ken Bousfield, P.E. Utah Division of Drinking Water.
Aerial Apparatus Operator Positioning Aerial Apparatus.
Firefighter III Module B Water Supply (4-19) (4-19)
Diesel Fuel - Fill Place all spill safety equipment where needed
Achieving Maximum Flows The Water Triangle.... The FIRE Tetrahedron.
Attack lines and pumping. What lines to pull?  Engineers should be able to understand what hose lines are for what purpose, what GPM they operate at,
TENDERS. VEHICLE / HEAVY EQUIPMENT SAFETY INSPECTION CHECKLIST OF 296.
Unit 9 – Scouting and Patrolling, and Communicating.
15 Water Supply. 15 Objectives (1 of 2) Discuss rural water supplies. Describe how portable tanks are used to supply water for firefighting. Describe.
Types of Fire Apparatus Equipped with a Fire Pump Sugar Land Fire Department Driver/Operator—Pumper Academy Spring 2003.
Fire Service Apparatus, Equipment & Terminology. Apparatus Any vehicle that serves a specific function, other than just transportation of people, is called.
Apparatus Testing Sugar Land Fire Department Driver/Operator-Pumper Academy Spring 2003.
This training meets the WAC Annual Training Requirements. This training does not qualify for NWCG Annual Wildland Refresher, such training must.
Water Shuttle Operations
Fire Ground Roles & Responsibilities On scene reports & Truck and seat assignments.
Relay Pumping Operations Sugar Land Fire Department Driver/Operator-Pumper Academy Spring 2003.
2010 Union County Water Movement Training Review Leesburg Twp. September 18, 2010.
Fire Hose Nozzles & Flow Rates
Welcome To High Rise Operations ! Like The Jefferson's...
Master Stream Operations
2013Q1.
MVP vs PUC Custom Chassis Ferrara MVP – Extruded Cab & Body Pierce PUC
FVCC Fire Rescue Fire Control.
Flammable and Combustible Liquids
NFPA 1901 – 1906 Revision Cycle Update
Bella Vista Fire Department Procedures on Sprinkled Buildings
Presentation transcript:

Engine Types and Uses

Types of Engines ICS Typing defines seven types of engines. It is important to match each type to the appropriate job when fighting wildland fires. Mobility of the engine in tight spaces is paramount when deciding which engine to use. The ICS engine designations are designed to give incident commanders a better idea of what resources are available to them at large-scale wildland fires. Pg 92 in the IRPG

Type 7 The unit will have a pump with minimum rating of 10 gpm at 100 psi, tanks with 50- to 200-gallon capacities 200 feet of 1-inch hose A crew of two. Primary use: mop-up and patrol duties, as well as control of fires in light fuels where burning conditions prevent rapid spread.

Type 6 The popular brush trucks have pumps with minimum ratings of 30 gpm at 100 psi, 150- to 400-gallon tanks. 300 feet of 1½-inch hose plus 300 feet of 1-inch hose. A crew of two. The primary function is mobile attack of fires in light fuels, but they also can be used for stationary attack, mop-up and patrol duties. A crew of three allows more extensive operations.

Type 5 These units are characterized by tanks of 400 to 750 gallons for operations in areas where water sources are scarce. They have pumps with minimum ratings of 50 gpm at 100 psi, but otherwise carry the same amount of hose and crew as Type-6 engines. They are used for direct attack and line control in light to moderate fuels.

Type 4 These are identical to Type-5 engines, except they carry 750 gallons or more of water. Certain state and federal departments use them for direct attack in large wildland areas. They are big and heavy, so medium-duty or heavy-duty chassis are common. Proper tank baffling and low centers of gravity are important for stability (Model 80).

Type 3 CDF made these units popular, and the design is now used by many other departments. The minimum specs include pumps with ratings of 150 gpm at 250 psi, 500-gallon or larger tanks, 500 feet of 1½-inch hose plus 500 feet of 1-inch hose and a crew of two. The higher pump pressure ratings are designed for use with long hoselays in steep terrain. These engines spend a lot of time performing structure protection duties, so they generally have 500-gpm pumps, more hose, short ground ladders and crews of three to five.

Type 2 This is classified as a structure pumper It has a pump with a minimum rating of 250 gpm or more at 150 psi, a 400-gallon or larger tank, a larger load of structure hose, 48 feet of ground ladders. A crew of three. These engines are best used for structure suppression and protection where pressurized hydrants are available.

Type 1 This is a full structure pumper. Type 1 has more 2-1/2-inchch hose, a 500 gpm or larger monitor and A minimum crew of four. Type 1 engines are best positioned on level, paved roads where pressurized hydrants are available. Unless they are specifically designed with short wheelbases and good ground clearances, they should not be assigned to areas where they have to negotiate narrow roads and driveways or operate off paved surfaces.