Control of DC and AC Interference on Pipelines

Slides:



Advertisements
Similar presentations
Columbia Gas of Ohio/Kentucky Tim Jenkins Corrosion Front Line Leader
Advertisements

Mitigation of AC Induced Voltage On Buried Metallic Pipelines
Electricity & Magnetism
Stray currents corrosion of underground steel pipelines
AC Mitigation Overview - TGA
Corrosion and Cathodic Protection
Friction Contact Induction. Current Electricity What is the difference between static electricity and current electricity ? Static electricity is stationary.
Y12 HSC Chemistry Shipwrecks and Corrosion R. Slider
What is an electric charge?
SMAW Equipment (Shielded Metal Arc Welding- commonly called “stick welding”, or “arc welding”)
Chapter 20 Electricity. Section 1 Electric charge and static electricity.
STRAY CURRENT CORROSION
Protection against Lightning Overvoltages Overvoltages due to lightning strokes can be avoided or minimized in practice by (d) shielding the overhead lines.
AC Mitigation Overview
1 An Introduction to Electronics by William O’Shaughnessy.
Cathodic Protection of Tower Anchors
Corrosion Prevention Corrosion of steel, which consists mainly of iron, is a major problem in our society. But steps can be taken to prevent it.
Electricity and magnetism
HOUSTON, TEXAS1 Corrosion Control and Monitoring ENGINEERING SERVICES LP HOUSTON, TEXAS Engineering Specification.
Electrical Fundamentals
4.1.5 Student Book © 2004 Propane Education & Research CouncilPage Determining the Proper Corrosion Protection Systems for Underground ASME Tanks.
Corrosion Management on Pipeline with Cathodic Protection
ELECTRICITY NOTES. ELECTRICITY ELECTRICITY: form of energy that occurs when electrons move from place to place Electricity can form whenever (e - ) electrons.
Corrosion Impact of Cathodic Protection on Surrounding Structures
Electrical Quantities and Basic Circuits
Electricity & Magnetism Static, Currents, Circuits Magnetic Fields & Electro Magnets Motors & Generators.
Electricity & Magnetism
MDY ’08 INTERNATIONAL SYMPOSIUM ON YACHT DESIGN AND CONSTRUCTION Capt. David Rifkin (USN, Ret.) June 2008 Madrid, Spain.
BASICS OF ELECTRICITY Vocabulary Understanding of Layer 1 & Layer 2 Networking Professionals need a basic understanding.
Basic Cathodic Protection Measurement and Monitoring- IR Considerations Western Regional Gas Conference 2008 Tempe, Arizona By Paul Sedlet, Accurate Corrosion.
Basic of Electricity Discuss the electrical properties of matter. Define voltage, resistance, impedance, current, and circuits.
NEPTUNE Power System Ground Return Electrodes Tim McGinnis & Colin Sandwith UW/APL.
WESTERN REGION GAS CONFERENCE AUGUST 21, 2012 CORROSION 101
Electricity & Magnetism Static, Currents, & Electro Magnets Motors & Generators.
Electricity & Magnetism Static, Currents, Circuits Magnetic Fields & Electro Magnets Motors & Generators.
What is a conductor? What is an insulator? Agenda for Tuesday Feb 22 nd 1.Electricity notes/demo All late work is due by Next Friday, March 4 th.
ELECTRICAL CELLS & CURENTS. DRY CELL & WET CELL Wet Cell – the electrolyte is a liquid (car battery) i. In a car battery, Electrolyte is sulfuric acid.
ELECTRIC CURRENT. What is current electricity? Current Electricity - Flow of electrons What causes electrons to flow? When an electric force is applied,
Electricity Vocabulary Negatively charged ion – Gains electrons Positively charged ion – Loses electrons.
Shipwrecks, Corrosion and Conservation Summary Slides PART 3 – Jack Dengate.
Electricity & Magnetism Static, Currents, Circuits Magnetic Fields & Electro Magnets Motors & Generators.
Electric Currents Charges in motion.. Creating Potential Difference. Alessandro Volta ( ) –Ranked potentials created by combing two metal discs.
DR. A. O. ADEWALE Course Outline: Electrostatics, potential and capacitance, dielectrics, production and measurement of static electricity. Current, Ohm’s.
Electricity and Magnetism
Electricity & Magnetism Static, Currents, Circuits Magnetic Fields & Electro Magnets Motors & Generators.
Grounding the Electrical System Reference: AAVIM “Electrical Wiring” Created May 2007.
A+ Computer Repair Lesson 4 Introduction to Electricity and Safety.
Electricity & Magnetism Static, Currents, Circuits Magnetic Fields & Electro Magnets Motors & Generators.
Static Electricity build up surface The build up of an electric charge on the surface of an object. does not flow. The charge builds up but does not flow.
Definition of Corrosion
Electricity & Magnetism
Basic Corrosion Theory
Electricity & Magnetism
Evaluation Techniques
Criteria for Cathodic Protection
Electricity & Magnetism
BY Presenter Name: G.V,Reddy DESIGNATION: Sr. General Manager
PRESENTATION ON AC & DC INTERFERENCE
Electricity & Magnetism
Electricity & Magnetism
Electricity & Magnetism
CHAPTER 6 Stray Current Interference.
Electricity & Magnetism
Corrosion Control and Monitoring
Field Testing for Shorted Casings
Corrosion Fundamentals
Fundamentals Course Basic Corrosion
Y12 HSC Chemistry Shipwrecks and Corrosion R. Slider
Corrosion Control and Monitoring
Electricity & Magnetism
Presentation transcript:

Control of DC and AC Interference on Pipelines Tony G. Rizk, P.E. Nigel Strike Vice President Western Director EMS USA Inc. EMS USA Inc. Houston, Texas Houston, Texas 713-595-7600 713-595-7600 trizk@emsglobal.net nstrike@emsglobal.net Notes go here.

CORROSION AND CATHODIC PROTECTION

Basic Corrosion Mechanism Metallic Path e- e- Electrolyte (water, soil, mud, etc.) Cathode (protected) e- Water e- In typical soils, at Cathode: Electrons consumed by water/oxygen – protective film forms Anode (corrodes) e- e- Copper Steel e- e- e- e- Corrosion Current (Conventional Current Flow) In typical soils, at Anode: Iron goes into solution and combines with ions in the electrolyte to form corrosion Deposits Corrosion Deposits

Basic Cathodic Protection Mechanism Metallic Path Electrolyte (water, soil, mud, etc.) e- e- Anode (corrodes) e- e- e- e- Copper e- e- e- Magnesium Steel e- Cathodes (protected)

Cathodic Protection – Galvanic System Cathodic Protection is the application of protective current from anodes onto the pipeline, forcing the pipeline to become cathodic. Cathodic Protection Test Station Cathodic Protection Current from Anode Groundbed Pipeline Magnesium Anode

Cathodic Protection – Impressed Current System Rectifier - + Cathodic Protection Current from Anode Groundbed Pipeline Cathodic Protection Anode Ground bed

Area of Pipe detected by electrode Basic Pipe-to-Soil Potential Measurement Negative + _ V DC - 1.150 High Impedance Voltmeter (Miller LC-4 Pictured) Copper-Copper Sulfate Reference Electrode Area of Pipe detected by electrode Polarization film Pipeline

DC STRAY CURRENT INTERFERENCE

DC Stray Current Interference Stray current interference occurs when DC current travels along a non-intended path. Where DC stray current is received by a structure, the area becomes cathodic and generally, no corrosion occurs Where DC stray current exits the structure to return to its source, corrosion occurs and depending on magnitude of stray current, can lead to accelerated corrosion failures.

DC Stray Current Interference Using Faraday’s Law, weight loss is directly proportional to current discharge and time … Steel is consumed at ~21 lbs/amp-year Example: A 1-inch diameter cone shaped pit in 0.500” thick steel would weighs 0.04 pounds. One ampere of DC current discharging from a 1-inch diameter coating holiday would cause a through wall, cone shaped pit to occur in 0.0019 years or 16 hours. Stray current corrosion can be a serious problem.

Sources of DC Stray Currents Static DC Currents: Foreign Cathodic Protection Systems Dynamic DC Currents: DC Traction Power Systems: Transit, People Movers, Mining Transport Systems HVDC : Imbalance, Monopolar Earth Return Welding Equipment with Improper Ground Geomagnetic (Telluric) Earth Currents

Corrosion Caused by Stray Current Foreign Pipeline Company Pipeline Rectifier - + Area of Current Discharge – ANODIC Anode Bed Area of Current Pickup – Cathodic

Testing and Identifying DC Stray Current Potential measurements (Close Interval Surveys) are typically used to identify stray current areas. Current Pickup Current Pickup Pipe-to-Soil Potential 0.85V Current Discharged Back to Source – Metal Loss (if Polarized Potential more negative than -850 mV, controlling reaction is the Oxidation of OH- ; no metal loss) V Line Being Interfered With Line Causing Interference

Mitigation of DC Stray Current There are several methods to control/eliminate DC stray currents: Eliminate the source, if possible Bond (direct bond or resistance bond) Recoating Shields Drain sacrificial anodes

Mitigation of DC Stray Current - Direct Bond + _ - 42 Meter Reads - 42 mV Bond Current = 42/0.01 = 4200 mA or 4.2A Direction of Current ? (polarity) Is this a Critical Bond ??? mV DC 0.01 Ohm Shunt Bond Box Bond Cable Foreign Pipeline Company Pipeline

Mitigation of DC Stray Current - Resistance Bond + _ Meter Reads - 3 mV Slide Resistor at 2 ohm Bond Current = 3/2 = 1.5 mA or 0.0015 A With Direct Bond 4.2 A, with Resistance Bond 0.0015A (must verify potential at crossing) - 3 mV DC Slide Resistor Bond Box Bond Cable Foreign Pipeline Company Pipeline

Mitigation of DC Stray Current - Recoating Test Station Company Pipeline (receiving current) New Dielectric Coating Applied at Crossing New Coating Applied at Crossing Discharge Stray Current (I) Ref. Electrode Foreign Pipeline (Discharging current) The application of the coating increases the resistance between the two pipelines, resulting in large reduction (and possibly elimination) of the Discharge Stray Current

Mitigation of DC Stray Current - Shields Test Station Company Pipeline (receiving current) Company Pipeline (receiving current) Dielectric Shield Ref. Electrode Foreign Pipeline (Discharging current) The application a non-conductive shield increases the resistance between the two pipelines, resulting in large reduction (and possibly elimination) of stray current

Mitigation of DC Stray Current - Drain Anodes Test Station Company Pipeline (receiving current) Drain Anodes Ref. Electrode Foreign Pipeline (Discharging current) The sacrificial anodes are installed to allow for a very low resistance path between the two pipelines, forcing the stray DC currents to discharge from the anodes (instead of the pipeline). Proper design of these anodes (number, size) is critical.

Mitigation of DC Stray Current Combination of Control Measures Test Station Company Pipeline (receiving current) New Dielectric Coating Applied at Crossing Drain Anodes Ref. Electrode Foreign Pipeline (Discharging current) The sacrificial anodes are installed to allow for a very low resistance path between the two pipelines, forcing the stray DC currents to discharge from the anodes (instead of the pipeline). Proper design of these anodes (number, size) is critical.

AC STRAY CURRENT INTERFERENCE

AC Interference High Voltage AC Power Lines Can Cause: AC Corrosion of The Steel Personnel Shock Hazard Due To Induced AC Voltages

AC Corrosion AC current can cause corrosion of the steel pipeline. Courtesy NACE

AC Corrosion Based on recent studies of AC corrosion related failures, the following guideline was developed: AC induced corrosion does not occur at AC current densities less than 20 A/m2; (~ 1.86 A/ft2) AC corrosion is unpredictable for AC current densities between 20 to 100 A/m2; (~ 1.86 A/ft2 to 9.3 A/ft2) AC corrosion typically occurs at AC current densities greater than 100 A/m2; (~9.3 A/ft2) Highest corrosion rates occur at coating defects with surface areas between 1 and 3 cm2 ( 0.16 in2 – 0.47 in2)

AC Induced Current Calculation Courtesy NACE Example: A holiday area of 1.5 cm2, with an induced voltage of 5.4 V would produce an AC Current Density of 100 A/m2 in 1000 ohm-cm soil.

AC Interference A more frequent consideration as right-of ways become more difficult to obtain. The electromagnetic field created by AC power changes 120 times per second. Metallic structures subject to a changing electromagnetic field will exhibit an induced voltage (hence induced AC current). Phase to ground faults can expose an underground structure to very high AC currents .

AC Interference Pipeline Soil The magnetic field generated by the overhead power lines induces an AC voltage onto the pipeline (which creates AC currents). The magnitude of such currents depend on many factors such as coating condition, soil composition, power line voltage, distance, etc. Pipeline Soil

AC Interference Aboveground Structures Only Electrostatic (Capacitive) Coupling Aboveground Structures Only (such as an above ground test station, a car, or pipe stored near ditch) Electromagnetic (Inductive) Coupling Structure Acts As Secondary Coil Structure Above Or Below Ground (most important component, causes AC corrosion of steel as well as personnel hazard potential) Conductive (Resistive) Coupling Buried Structures Only (during line faults)

AC Interference – Computer Modeling Conditions Modeled: Steady State Induced AC Levels Pipe Potentials Under Phase-to-Ground Fault Potentials to Remote Earth Step Potentials Touch Potentials 15 volt Limitation for Protection of Personnel 1000 volts - 3000 volts Causes Coating Damage >5000 volts Can Cause Pipe Structural Damage

AC Interference – Mitigation Measures Separate Structure and AC Line Use Dead Front Test Stations (to eliminate shock hazard) Install Polarization Cells to Ground (grounding) Install Semiconductor Devices to Ground (grounding) Use Bare Steel Casings or anode beds as Grounds with DC Decoupling devices (capacitors, polarization cells) Install Equipotential Ground Mats at valves, test stations (for shock hazard) Use Sacrificial Anode and paralleling zinc ribbon or Copper wire as Ground Electrodes (normally with decoupling devices)

Codes and Standards EPRI/AGA “Mutual Design Considerations for Overhead AC transmission Lines and Gas Pipelines” NACE RP 0177 “Mitigation of Alternating Current and Lightning Effects on Metallic Structures and Corrosion Control Systems” Canadian Electrical Code C22.3 No. 6-M1987 “Principles and Practices of Electrical Coordination between Pipelines and Electric Supply Lines”

Dead Front Test Station (Personnel Protection) Insulated Test Posts

Polarization (Kirk) Cell - Grounding Fill Hole Cell Terminals Potassium Hydroxide Solution Stainless Steel Plates Rated Capacity Steady State Model for 0.5 seconds (amps) Rating (amps) K-5A 5,000 30 K-25 25,000 175 K-50 50,000 350

Semiconductor Decoupling Devices - Grounding PCR – Polarizartion Cell Replacement Courtesy of Dairyland SSD – Solid State Decoupler

Examples of De-Coupling Devices - Rating Polarization Cell Replacement (PCR) 60 Hz Fault Current @ 1 cycle: 6,500; 20,000; 35,000 A @ 3 cycles: 5,000; 15,000; 27,000 A Lightning Surge Current @ 8 X 20 µseconds: 100,000 A Steady State Current Rating: 45 or 80 amps AC Solid State Decoupler (SSD) 60 Hz Fault Current @ 1 cycle: 2,100; 5,300; 6,500; 8,800 A @ 3 cycles: 1,600; 4,500; 5,000; 6,800 A Lightning Surge Current @ 4 X 10 µseconds: 100,000A ; 75,000 A Steady State Current Rating: 45 amps AC

Zinc Ribbon Installation for AC Mitigation - Grounding

Equipotential Ground Mat - Used to Protect Personnel from Electric Shock (at test stations, valves, etc.) Test Station Zinc Ground Mat Connected to Pipe Coated Pipeline

Mitigation of AC Interference Using Distributed Galvanic Anodes Overhead HVAC Transmission Line Underground Pipeline Distributed Sacrificial Anodes Without Anodes Induced Voltage With Anodes Distance

Soil resistivity measurements at high VAC locations Testing the Effectiveness of AC Mitigation: AC pipe-to-soil potential (at test stations and above ground appurtenances) to test for shock hazard voltage A CIS (both VDC and VAC) to test the effectiveness of the cathodic protection system as well as the AC potentials on the line. (ON/OFF, the use of decouplers is critical to collect OFF potentials) Soil resistivity measurements at high VAC locations Calculation of IAC to determine risk of AC corrosion Additional localized mitigation measures if needed

THE END Thank You! Questions?