3200A Options / Technical Overview. 3200A Electrical Test Calibrator Innovative design to bring advances in technology to the calibration of Electrical.

Slides:



Advertisements
Similar presentations
Digital Current Transformer Reporter
Advertisements

CABLE FAULT ANALYSIS BY UTMANCO SYSTEMS (P) LTD. What is a Fault ? DEFECT WEAKNESS INCONSISTENCY OR NON- HOMOGENEITY THAT AFFECTS THE PERFORMANCE OF THE.
Electrical Installation
ProEdit Procedure Management Writing a Verification Procedure For a Megger CM500 Combination Tester - Loop Function.
Understanding GFCIs Developed by NEMA Ground Fault Personnel Protection Section (5PP) Developed by NEMA Ground Fault Personnel Protection Section (5PP)
Potentiostat Basics I’m Max Yaffe
Inspection & Test Overview suite412.
1 Lab Equipment. 2 TopicSlides DC Power Supply3-4 Digital Multimeter5-8 Function Generator9-12 Scope – basic controls13-20 Scope – cursors21-24 Scope.
MEASUREMENT DEVICES OUTLINE Multimeters Analog Multimeters
The Association of Electrical and Medical Imaging Equipment Manufacturers Understanding GFCIs Developed by the NEMA 5PP Personnel Protection Technical.
© 2011 Ericson Manufacturing, Willoughby, Ohio
CheckSystem 2.1 Portable Test Systems Page 1 April 2011.
Electrical Safety Testing of Electrical Installations and the verification of Electricians Test Tools Michael Bailey Transmille Ltd NCSLi 2014Transmille.
©2004 Fluke Corporation Insulation Resistance Testing 1 Insulation Resistance Testing.
PRACTICAL ELECTRONICS MASTERCLASS (Mr Bell) 1. Fault finding A fault is when a piece of equipment does not work the way it had been intended too. Fault.
Circuit Protection Electrical circuits require protection to prevent fire or electrocution in the event of a fault. There are two main types of circuit.
ProCal Calibration Software
Safety Testers (plus more) from Dranetz and Gossen Metrawatt General Presentation.
3200A Electrical Test Equipment Calibrator. Automatic Loop Correction To simplify calibration of loop testers, the 3200A can be fitted with the Auto.
Electrical Measurements: Meters
Chapter 7 SYSTEM PROTECTION
Why do wires get hot when a current passes through them?
INSULATION TESTER CALIBRATION Using the 3200 Electrical Test Calibrator.
TRANSMILLE PATs The New Alternative To Fast, Easy & Efficient Portable Appliance Testing.
Area of Study 2: Electricity
Electricity at Work.
PROEDIT WRITING A PROCEDURE USING THE BUILT-IN PROCEDURE WIZARD.
Training Learning to Work Efficiently and Accurately.
Training Making accurate Electrical Measurements.
Extending the workload of the 3000 series calibrators Laboratories usually have to calibrate a very wide variety of instruments. Normal the volume of the.
Phase Presence and Sequence Tester (FAST-1) Boris Fradkin 2015 A.L.F. Enterprise.
RCD TESTER CALIBRATION Using the 3200 Electrical Test Calibrator.
8000 Series Options/Technical Overview Series Precision Digital Multimeter New Technology – Multi Processor design No need for AutoCal – High precision.
DMM4020 Digital Multimeter Fact Sheet Measurements with the Push of a Button Features Featuring:  5.5 digit resolution  Basic V dc accuracy of up to.
MAINS ELECTRICITY. Specification Electricity Mains electricity understand and identify the hazards of electricity including frayed cables, long cables,
Lesson 6 Voltage Do we need to MEASURE it? OR Do we need to DETECT it?
8000 Series Options/Technical Overview Series Precision Digital Multimeter New Technology – Multi Processor design No need for AutoCal – High precision.
 “A multimeter is an instrument designed to measured electric current, voltage and usually resistance, typically over several ranges of value”.
ADT490 Panel Theory. 2 System Power Supply Grounding ‣ Circuit separates positive / negative from Ground ‣ Ground fault - resistance to ground ≤ 10 kΩ.
3200 Electrical Test Equipment Calibrator The Total Solution to Electrical Test Equipment Calibration.
PR570 POWERITE II TRAINING Dedicated to Success in Electronic Servicing for 50 Years.
1000 Series Ultra-Portable Multi Function Calibrator Portability, without compromise.
1 of 25 © 2007 Ideal Industries Power Quality At the Plug IDEAL INDUSTRIES Author: Patrick Elliott Application Guide to Power Quality.
Grounding.
PAT TESTER CALIBRATION Using the 3200 Electrical Test Calibrator.
Main contacts closed – RED Colour with ON
16 th Edition Testing FAQ Common Issues With 16 th Edition Testing.
Testing of Low Voltage Installations
LOOP TESTER CALIBRATION Using the 3200 Electrical Test Calibrator.
Self Switching Power Supply. Introduction Self Switching Power Supply  Embedded system requires a regulated power supply.
Digital Multimeter – Basic Guide
PCAR Precision In Practice 1 Precision In Practice Achieving the best results with precision Digital Multimeter measurements Paul Roberts Fluke Precision.
Introduction High Voltage!!.
PROTECTION AGAINST INDIRECT CONTACT
THREE PHASE FAULT ANALYSIS WITH AUTO RESET ON TEMPORARY FAULT AND PERMANENT TRIP OTHERWISE Submitted by:
Grounding.
Electrical Safety Describe and explain how a fuse works as safety device. Describe and explain how a circuit breaker works as a safety device. Explain.
Starter Review your filament lamp experiment and make corrections (in green pen) Review your test and complete the front cover sheet, correct any mistakes.
GROUND-FAULT GROUND-CHECK MONITOR
THREE-PHASE GROUND-FAULT BASICS
HVI HIPOT TEST SET Pft sERIES.
Calculating the maximum allowable earth fault loop impedance.
What Is to Be Covered? Electrical Shock - Why Have GFCIs?
Model Output Current Battery Life BATPSU VDC 2A 1.2Ah BATPSU VDC 2.3Ah
MAINS ELECTRICITY.
Electrical components and systems
Electrical components and systems
Electrical components and systems
724 Temperature Calibrator
Presentation transcript:

3200A Options / Technical Overview

3200A Electrical Test Calibrator Innovative design to bring advances in technology to the calibration of Electrical Test Equipment Calibrates Insulation Testers, RCD Testers, Loop Testers, Multifunction Testers, PAT Testers, Flash & Breakdown Testers Transmille Ltd

3200A Feature Overview Transmille Ltd FunctionComments Continuity Resistance SourceHI Accuracy Option Available Continuity Current Measurement Insulation resistance Source15kV Tester Option Insulation test Voltage Measurement16 th and 17 th Edition Compliant AC Voltage OutputContinuously Monitored RCD Test Time Measurement RCD Test Current MeasurementAuto Waveform Analysis RCD Test Duration Measurement Loop Resistance SourceAutoLoop Option PAT Earth BondSource Resistance & Measure Current to 30A PAT Leakage PAT Leakage Test Voltage Measurement PAT Load TestingOptional Adapter PAY Flash Voltage TestingOptional Adapter PAT Flash Crrent Testing

3200 Electrical Test Equipment Calibrator – Insulation Tester Calibration Calibrating Insulation testers with the 3200 is simple. All the functions required are in one instrument, making calibration fast and simple. Use with ProCal software to automate and save even more time.  Insulation Resistance from 100kohms to 10Gohms at 1kV  Measurement of Insulation Test Voltage at 1mA load  AC Voltage Calibration to 400 Volts  Continuity Resistance from 0 to 1kohms  Continuity Resistance Current to 300mA Measured into 1ohm

3200 Electrical Test Equipment Calibrator – RCD Testers Residual circuit breaker testers are designed to test and measure the break time of AC mains (RCD) trips at set test currents. Fault current is allowed to pass between live phase and earth. The ‘fault’ current is started by pressing a button on the tester, usually an LCD counter on the tester measures the time in milliseconds until the mains supply is disconnected. The 3200A has been specially designed to make the calibration of RCD testers safe & straight forward, which can otherwise be quite difficult and even dangerous. To calibrate an RCD tester, it is necessary to measure the current taken from the mains supply by the tester on each of its ranges and the time period measured shown on the testers display to the disconnection of supply. The 3200A can calibrate both functions. Intelligent firmware measures the correct fault current ignoring pre-test currents from testers such as the AVO CM500. The 3200A also provides accurate timed disconnection of the supply to verify the testers timing accuracy. Some RCD testers have additional functions such as which half cycle of the mains the fault current started, fault current duration etc. which can also be tested by the 3200A.

3200 Electrical Test Equipment Calibrator – Loop Tester Calibration To calibrate a Loop Tester simple connect to the 3200, select the loop function and run auto loop. Select the required loop value on the 3200 and press test. The 3200 automatically checks for a faulty loop tester before applying the full mains supply.  Automatic Measurement and compensation of supply loop impedance  Automatic detection of faulty Tester preventing damage to 3200  8 loop values from 0.05ohm to 1kohm.

3200 Electrical Test Equipment Calibrator – PAT Calibration There are several different measurement functions to be calibrated on a PAT tester. The functions required are all in the 3200 ensuring fast and efficient calibration of these instruments.  Earth Bond Resistance  Earth Bond Current Measurement to 30 Amps  Insulation resistance from 1M to 10Gohms  Leakage Current Measurement  Class 1 & 2 Flash Voltage Measurement

Increased Productivity Transmille Ltd Reduced Test Times = Rapid Return On Investment

External Options Transmille Ltd External HiPot/Breakdown option makes testing Breakdown testers fast and safe. EXTHV extends the resistance range of the 3200 to calibrate High Voltage insulation testers safely and without the need for expensive resistors

3200 Electrical Test Equipment Calibrator – HIPOT / Breakdown Tester Calibration  3kV & 12kV AC/DC Measurement Ranges  200uA 2mA 20mA Current Ranges  200uA : 5M  10M  20M  Loads  2mA : 500k  1M  2M  Loads  20mA : 50k  100k  200k  Loads  Current ranges : 1kV maximum  Power On & Overload Indicators  Requires 3200 Calibrator VOLTAGE MEASUREMENT  Connects between ground and appropriate voltage terminal  Select voltage range (3kV / 12kV AC/DC) and read back the voltage measured from the display of the CURRENT LOAD  Three electronically selectable ranges, nine current loads Select current range using the 3200 ‘softkeys’  Connect breakdown tester between ground and the appropriate resistor socket.

3200A vs 5320A Transmille Ltd is Easier to use – Electrical socket on front panel means direct connection for RCD and Loop Testers Extended Workload – Using the external options extend the workload of the 3200 Ultimate Portability – 3200 weighs only 10Kg, 5320A weighs almost double Lower cost of initial investment External HiPot/Breakdown box simulates loads as well as measures voltage