Agile - affordable - accurate Optical System and Measurement Technology Presentation.

Slides:



Advertisements
Similar presentations
What happens in the aperture?
Advertisements

Lasers in medicine: blood and blood flow in the tissues Today’s talk... 1.Introduction to blood and blood flow 2.Laser Flow-Cytometry (LFC) of blood...
MLAB 1415: Hematology Micros 60.
DxH 800 Flags, Codes, Messages
Scanning Confocal Basics n What’s so special ? n Confocals give higher resolution than normal microscopes. n Confocals can OPTICALLY SECTION a sample.
Electrical Impedance and Colorimetric Measurements Joanna Ellis, MLS(ASCP)
Automated Hematology Cell Counters
CHAPTER 37 MLAB 1415 HEMATOLOGY JOANNA ELLIS, MLS(ASCP) Optical Light Scatter and Flow Cytometry.
R. Hui Photonics for bio-imaging and bio- sensing Rongqing Hui Dept. Electrical Engineering & Computer Science, The University of Kansas, Lawrence Kansas.
© From J. G. Webster (ed.), Medical instrumentation: application and design. 3 rd ed. New York: John Wiley & Sons, Figure 11.1 Block diagram of a.
Instructor: Lichuan Gui
HFT 405, nm 405nm 488nm 405nm Only 405 and 488 are reflected All other wavelengths are transmitted 488nm 405nm This is the first beam splitter that.
FLOW CYTOMETRY Dr. MOHAMMED H SAIEMA LDAHR KAAU FACULTY OF APPLIED MEDICAL SCIENCES MEDICAL TECHNOLOGY DEPT. 2 ND YEAR MT INSTROMINTATION EXT
Automation in hematology Until Slide 23
Chapter 5 Diagnostic Testing. Overview of Diagnostic Testing PURPOSE OF DIAGNOSTIC TESTING  To help determine the exact cause of signs or symptoms 
Basics of Flow Cytometry Holden Maecker. Outline Definitions, what can be measured by flow cytometry Fluidics: Sheath and sample streams, flow cells,
Practical Hematology Manual
STUDY OF NEUBAUER’S CHAMBER
Methods to Detect Red Cell Membrane Disorders
M201 Microplate Reader This power point file is prepared mainly for the engineers of our distributors.
A compact 5-diff solution
Agile - affordable - accurate. Hematology, is the part of internal medicine, that is concerned with the study of blood, the blood-forming organs, and.
Cell viability studies Sepideh Khoshnevis. The Goal To distinguish live cells from dead and apoptotic cells in order to calculate the the percentage of.
Analyticon Biotechnologies AG
Clinical Haematology & Cell Counting
Flow Cytometry at Boston University Medical Campus Introduction to some methods that we offer Yan Deng (X4-5225), Gerald Denis (X4-1371),
Dr Gihan Gawish Hydrodynamic focusing is a technique used to provide more accurate results from flow cytometers or Coulter counters for determining the.
 Flow cytometry is a technique for counting, examining, and sorting microscopic particles suspended in a stream of fluid.
CLS 541-Advanced Medical Haematology M. sc. Program Lab-2-
Automation in haematology
Chapter 5 Hematology. Figure 5.1 (a) A double ended needle partially pierces the rubber stopper in an evacuated tube. (b) After the left needle pierces.
Haematology.
Flow Cytometry Principles & practice of “Fluorescence Spectroscopy in Biological Diagnosis & Research” Dr.Hekmatimoghaddam Assistant professor of pathology.
Advanced Biology Visualizing Cells. The Human Eye  Resolution – The minimum distance two points can be apart and still be distinguished as two separate.
FLOW CYTOMETRY  Definition: Measuring properties of cell as they flow in a fluid suspension across an illuminated light path.
Flow Cytometry Basic Training. What Is Flow Cytometry? Flow ~ cells in motion Cyto ~ cell Metry ~ measure Measuring properties of cells while in a fluid.
1 Flow Cytometry in the Clinical Laboratory Patricia Aoun, M.D., M. P. H. Jean Bailey, MT-ASCP Kellie Neth, MT-ASCP The Nebraska Medical Center.
Flow Cytometry Becton Dickinson Asia Limited Company.
SCM 330 Ocean Discovery through Technology Area F GE.
Grounding Guidelines Developed for LBNE
WBC and Differential measurement
A MEMS Micro Flow-cytometer Based on Dielectric Particle Focusing and Integrated Optical and Impedance Detection Peter R.C. Gascoyne Department of Molecular.
Sysmex XE-2100 Counting of Red Cells and Platelets by impedance & fluorescent techniques.
Medical Laboratory Instrumentation (Blood cell counter) Third Year Dr Fadhl Alakwa UST-Yemen Biomedical Department.
Preparing a Blood Smear. Samples for Hematology Capillary blood and venous blood can be used for hematology tests. Capillary blood is beneficial if a.
HAEMATOLOGY LINE A.C.KAROBIA
Hematology Unit 2 Chapter 8 Automated Analyzers Copyright © 2015 by Mosby, an imprint of Elsevier Inc. All rights reserved.
By c.Keerthana.  First described by Dutch physicist frits Zernike in  It is a type of light microscopy.  It is a contrast enhancing optical technique.
Electrical Impedance and Colorimetric Measurements
Automatic Electronic Blood Cell Counting
Medical Laboratory Instrumentation
ABX Pentra DF 120 Flexible hematology platform For internal use only
Flowcytometry.
International Operations
PS3D culture Polycarbonate filter, 0.2µm
اساس اندازه گیری در سل کانتر
PENTRA 60 C +.
Product specification
Flow Cytometry and Sorting Part 1
P.J. Caspers, G.W. Lucassen, G.J. Puppels  Biophysical Journal 
Sysmex XE-2100 NRBC Detection.
Reticulocyte Detection
Optical measurement.
Kap.11 Clinical laboratory
Flow Cell Injector Tip Fluorescence signals Focused laser beam Sheath
P.J. Caspers, G.W. Lucassen, G.J. Puppels  Biophysical Journal 
Flow Cell Injector Tip Fluorescence signals Focused laser beam Sheath
Presentation transcript:

agile - affordable - accurate Optical System and Measurement Technology Presentation

agile - affordable - accurate History of optical cellcounting Original needs:  Limited capabilities of volumetric impedance method: differentiation is based on cell volume only  Better leucocyte differentiation based on internal cell structures  Recognition of atypical cells with clinical application: Nucleated RBC- s, Reticulocytes, Immature WBC-s, Atypical Lymphocytes

agile - affordable - accurate  Light Absorbance(combined with Volumetric Impedance or Radio Frequency)  Laser Light Scattering (generally used in haematology, it some cases combined with RF)  Fluorescence (used in immune-haematology and immunology) Optical methods

agile - affordable - accurate Forward Laser Light Scattering method: LaserOptics Flow cell Detectors Low-, and high angle scatter lights from cells

agile - affordable - accurate The optical head incorporates a solid-state laser light source (wavelength: 635 nm, maximum power: 7mW), the beam is focused by means of a lens assembly… Lens assembly (laser aperture)

agile - affordable - accurate …to the center of an optically clear, quartz-glass flow cell. The channel located in the center is rectangular, its’ walls are parallel with the outer walls of the flow cell to eliminate light diffraction. Cross section for flow is 250 × 250 µm.

agile - affordable - accurate Assembled Laser Head, side view

agile - affordable - accurate Sample is injected from below of the flow-cell, in the sheath flow which force the cells to pass through the flow-cell in the middle of the sheath fluid one by one(laminar flow, hydrodynamic focusing). „Laser” waste Sensing zone(cross section of laser light) Sample stream Sample injection needle Sheath inlet ports Flow cell inner walls(counting channel)

agile - affordable - accurate As a result an about 40 µm wide sample stream passes before the sensing zone(an about 200 µm wide laser beam), the laser light is scattered by the cells. Scattered light signals are collected by an optical cable mounted behind the flow-cell. The cable has two concentric zones divided by a metal ring for low angle and high angle scattered light sensing.

agile - affordable - accurate The other ends of the optical cable are connected to the two PIN photodiodes mounted on the Optosensor Board. To avoid damage of the PIN photodiodes direct laser light is filtered by a laser dump mounted in front of the optical cable. High angle zone Low angle zone „Laser dump” plate Focused laser beam Metal ring (separates low and high angle zones)

agile - affordable - accurate Low Angle Forward Scatter (information about size) High Angle Forward Scatter (information about the internal structure) Direct Light (goes through the cell, it is stopped by the laser dump) Focused laser beam Cell membrane scatters the light in low angle, so low angle scatter gives information about the size of the cells while higher angle scatter comes from the internal structure thus provides information about the complexity of cells.

agile - affordable - accurate With the measuring time fixed, from each sample around 4000 – cells* are counted. Each cell has scatter information recorded, and displayed on the scattergram. * in case of human samples with normal values and normal level control blood

agile - affordable - accurate Hemolyzer 5 performs 4Diff and BASO optical count from each sample. 4Diff dilution: - temperature controlled(TCU, 29°C) - whole blood + Diluent + Lyse5P => mixing - RBC’s, PLT’s are lysed - Diff5P is added to avoid overlysing of WBC’s(the lysing process is stopped) - the 4Diff dilution is transferred to the optical head 4Diff = NEU, MON, LYM, EO populations

agile - affordable - accurate „4 DIFF” Scattergram MONO Low angle scatter High angle scatter S I Z E COMPLEXITY RBC GHOST EONEU LYM

agile - affordable - accurate BASO measurement: - in the 4Diff count the Basophile leukocytes cannot be clearly differentiated from the other cells - additonal optical BASO count is needed - in the WBC/HGB dilution all WBC’s are (over)lysed except the Basophiles (chem. behaviour like lyzer) - after the impedance count the WBC/HGB dilution is transferred to the optical head for optical BASO count

agile - affordable - accurate „BASO” Scattergram BASO LYM, MONO, NEU, EO

agile - affordable - accurate Impedance measurements: - RBC/PLT: aperture size: 70µm - total WBC number(non differential measurement): aperture size: 80µm - photometric HGB determination

agile - affordable - accurate THANK YOU FOR YOUR KIND ATTENTION!