APPLICATION OF MICROTESTER FOR DETECTION OF LOW MICROBIAL CONTAMINATION Oliver Reichart Katalin Szakmár.

Slides:



Advertisements
Similar presentations
Most Probable Number Statistical Procedure used to estimate the number of bacteria that will grow in liquid media. Gives a 95% probability that the bacterial.
Advertisements

Bacteriological Examination of water, milk and air
Lab. No. 11. Food Microbiology Water  Milk  Most important water contaminants: Bacteriological Examination of water  Escherecia coli  Enterococcus.
Lab 4: Most Probable Number Method (MPN)
ENUMERATION OF MICROORGANISMS
Serial dilution and colony counting ● Serial dilution and colony counting – Also know as “viable cell counts” – Concentrated samples are diluted by serial.
General Microbiology (Micr300) Lecture 4 Nutrition and Growth (Text Chapters: ; 6.1; ; )
Key Area 6 : Growth in Micro-organisms
..Counting Bacteria.. Made By: Duaa Mohammed EL- Boh. ID: Supervised By: DR. Abdelraouf Elmanama.
Microbial Nutrition and Growth Microbial Population Growth
The Serial Dilution Method of Bacteria Enumeration
Introduction to Lab Ex. 19: Enumeration of Bacteria
Faculty of Medicine and Health Sciences Microbiology Lab Second semester 2014 prepared by: Mohammad Al-Qadi
CULTURE MEDIA LECTURE 5: Microbiology and Virology; 3 Credit hours
 Bacterial Enumeration Gloria Phuong Le Microbiology Lab Dr. Fran Norflus.
Bacterial count.
Microbial Growth Growth in Batch Culture
Microbiological inspection of mineral water by redox-potential measurement Dr. Olivér Reichart Dr. Katalin Szakmár.
Dilution calculations 1.You are interested in determining the number of bacteria in saliva. You spit into a tube, and then do four 1/10 dilution's. From.
Bacterial Abundance Objective Measure bacterial numbers and mass per unit volume. Note, we are not concerned with identification here. Why do we want to.
Study of microorganisms in foods by conventional methods
Lecture: Chapter 6 (Microbial Growth) Exercise 9: Aseptic Technique
Culturing of Bacteria.
Culturing Yeast Cells on Media. Pre Lab Definitions: Petri Dish: A round, shallow dish used to grow bacteria. Culture: To grow living organisms in a prepared.
Culturing requirements
Bacterial Growth Curve
Micro (2-1) TOTAL VIABLE COUNT Dr. Shahzad Ali Assistant Professor Department of Wildlife and Ecology UVAS, Ravi Campus, Pattoki.
PHT 226 Lab number 7 Total and viable count of bacteria.
Growth of bacteria in culture
Bacterial Growth l Introduction –Population vs. Cellular Growth –Exponential vs. Arithmetic Growth –Bacterial Growth - Binary Fission.
LAB 4: ASEPTIC TECHNIQUE AND ISOLATION OF BACTERIA
Working with yeast Microbiologists have developed techniques for isolating and maintaining strains in the laboratory Strains: microorganisms of the same.
REDOX-POTENTIAL MEASUREMENT AS A RAPID METHOD FOR MICROBIOLOGICAL TESTING.
Microbial Nutrition and Growth
Practical Part Microscopic Examination of Microorganisms Experiments Identification of MOs Different Staining Techniques.
Microbial Count Aim: Count the number of bacterial cells in a provided sample Methods: Total count, Viable count I. Total count This technique involves.
4.4 Microbiology. Classifying Bacteria - shape According to shape Coccus -plural Cocci Bacillus -plural Bacilli Spirillum – plural Spirilli.
Typically refers to an increase in population rather than in size
2.4 Biological Parameters Micro-organisms that bring diseases are called “PATHOGEN”. Their quantities are very small compared to other micro-organisms.
Lab 8: Most Probable Number Method (MPN). Most Probable Number Method (MPN) What is the MPN method? How to determine the amount of bacteria from the MPN.
Introduction Many studies require the quantitative determination of bacterial populations. The two most widely used methods for determining bacterial.
Nutrition and Growth: Nutritional Classification – Energy source – Carbon source Requirements for Growth – Temperature - pH – Salts - Oxygen – Nutrients.
Food Microbiology 1 Unit 4 Microbial Growth. Bacteria are single-celled organisms Bacteria multiply in a process called binary fission in which two cells.
Characteristics and study of prokaryotic growth How do we grow bacteria in the laboratory? What is required for growth? How do we measure bacterial growth?
Recognizing the conditions necessary for microbial growth is vital to disease prevention and treatment.
 Many studies require the quantitative determination of bacterial populations. The two most widely used methods for determining bacterial numbers are:
Enumeration (determine the numbers of bacteria in a sample) Direct Measurement of Microbial Growth  Microscopic count - the microbes in a measured volume.
Influence of Chemical and Physical Factors in Environment
Microbial Biotechnology Reem Alsharief Lab 3. General Methods of Isolation and selection of Microorganism Microbial isolation: To separate (a pure strain)
NEAGU LILIANA Microbiologist for Romanian National Institute of Public Health Dr.A. Leonte 1-3, Sector 5, Bucharest, Romania
Microbial Growth Growth in Batch Culture
Growth of Bacterial Culture
A very common question that gets asked is: “Why does my ATP test tell me that I have substantial microbial contamination when my culture-based tests tell.
M ICROBIAL G ROWTH AND E NUMERATION. O BTAINING P URE C ULTURES  Pure Culture: Contains a single microbial species.  Most clinical and environmental.
ENUMERATION OF MICROORGANISM IN FOODS
MICROBIAL GROWTH AND REQUIREMENTS
Bacterial Count.
Miroslav Votava, Vladana Woznicová Lecture for 2nd-year students
Increase in number of cells, not cell size Populations Colonies
Biofilms Microbial communities Form slime or hydrogels
Microorganisms & Biotechnology
Learning Objectives i Understand the basic aseptic techniques used in culturing organisms. ii Understand the principles and techniques involved in culturing.
النمو والعد البكتيري Microbial growth النمو الجرثومي.
Introduction Many studies require the quantitative determination of bacterial populations. The two most widely used methods for determining bacterial.
Composition of Domestic Wastewater
Lab 6: Most Probable Number Method (MPN)
Metode Manual (Bergeys manual of bacteriology) sni.
Counting Microorganisms
Metabolism and Survival
Lab 6: Most Probable Number Method (MPN)
Presentation transcript:

APPLICATION OF MICROTESTER FOR DETECTION OF LOW MICROBIAL CONTAMINATION Oliver Reichart Katalin Szakmár

Classical microbiological methods Long incubation time (1-4 days) The applicability, reliability and test prices of the methods are concentration-dependent: High concentration:dilution and colony counting in the range of cfu/ml. Low concentration: Membrane filtration

The Microtester method The energy source of the growth is the biological oxidation which results in a reduction in the environment. Due to the oxygen depletion and the production of reducing compounds the redox-potential of the nutrient medium changes. The redox-potential of the medium is a well measurable parameter which could be used for the determination of the microbial multiplication.

MicroTester System, 32 Channels  Water baths  Test cells  Measuring modules  Computer, Monitor

Direct test cells

Indirect test-cell

Redox-curves of several bacteria

Characteristics of the redox-curves

Detection criterion (DC) The detection criterion is the critical rate of the change of redox-potential (dE/dt, the slope of the redox curve) which is significantly differing from the random fluctuation and could be ascribed to the multiplication of the microbes. (e.g. DC = |dE/dt| = 0.5 mV/min). Detection time (TTD) The detection time (TTD) is that moment when the absolute value of the rate of redox potential change in the measuring-cell exceeds the detection criterion. |dE/dt|  DC mV/min). As the critical rate of the redox potential decrease needs a well-defined critical cell number (Nc = 10 7 cfu/ml) the detection time depends on the initial microbial count, N 0. Characteristics of the redox-curves

Positive detection In the inoculated medium the microbes after the lag phase start to multiply. Due to their metabolism the redox-potential decreases in the test cell. After a time (depending on the inoculum size) the rate of decrease exceeds the detection criterion. The system gives a TTD value which refers to the presence of multiplying microorganisms (in about cfu/ml concentration). Keeping on the redox-measurement appears a typical redox-curve characterizing on the microbe or microbial group growing in the test cell. As a result of the multiplication we get a suspension of cfu/ml with visual turbidity.

False positive detection in selective medium In case of massive inoculation (i.e. from the surface of solid medium with a loop) the initial microbe concentration in the test cell could exceed the value of cfu/ml and causes visual turbidity. The exo-enzymes and metabolites of the inoculum start immediately to reduce the redox-potential of the medium which could result in TTD detection in the initial concave section of the redox-curve. As the multiplication is inhibited by the selective medium the characterising convex section of the redox-curve does not evolve.

Redox curves in cetrimide broth

Effect of the inoculum size on the redox-curves TTD for the redox-potential measurement is: |  E/  t|>1mV/min

Effect of the initial cell concentration on TTD

Calibration curves Strict linear relationship exists between the logarithm of the viable count of the test cell inoculum, log N(c) and the detection time (TTD) which is represented by the calibration curve. The equation of the calibration curve makes possible to calculate the viable cell count on the base of TTD in a very wide range: log N(c) = A · TTD + B The calibration curves refer on the test cell and the microbial contamination of the sample is calculated by the software automatically.

MPN calibration curves MPN calibration curve is applied when the previously constructed calibration curve cannot be taken. In this case, the redox potential measurement could be combined with the MPN method and the software makes possible the on-line determination the most probable microbial count and the calibration curve. From the sample the usual dilution series is prepared up to a dilution which is free of microbe. In case of low cell numbers apply membrane filtering. Place the membranes into the measuring cells and record the redox curves.

Redox-curves for the E. coli calibration

Determination of the calibration curve Based on the last dilution level still showing multiplication (TTD), the most probable cell-number of the undiluted (most concentrated) sample, MPN(0) is determined automatically by the program. With the knowledge of MPN(0) and TTD values belonging to the several dilutions, the software calculates the equation of the log MPN calibration. Having determined the microbial contamination of the sample with a classical reference method and inputting the result, the system automatically recalculates the MPN calibration to logN calibration.

MPN calibration

MPN and logN calibration

Calibration curve

Redox-curves. How long to measure? If we have got TTD value it is proposed to continue the measurement until the redox curve is taking shape. Having no TTD it is proposed to measure until the estimated microbial count in the test cell (calculated by the calibration curve) drops below 1/100, logN(c) < -2.

Time to „detection no microbe”, TTDN In the test cell logN(c) ≤ -2 logN(c) = A·TTD + B TTD = [logN(c) – B] / A A = h -1 B = Time to detection no microbe:TTDN ≥ 11.2 h

Time to „detection no microbe”, TTDN Microbe/mediumMediumCalibrationTTDN (ml)A (h -1 )B(h) E. coli 15-0,6278,307 16,4 BBL 44 °C50-0,85410,260 14,4 Cb. freundii 15-0,4207,449 22,5 BBL 37 °C50-0,66710,332 18,5 Ps. aeruginosa 15-0,5959,456 19,2 Cetrimide 37 °C50-0,51311,111 25,6 Entc. faecalis 15-0,4067,645 23,7 Azide 37 °C50-0,4809,482 23,9

Application for low microbial contamination Membrane filtering Microbe concentration of the sample:N(0) cfu/ml Volume of the filtered sample:V(0) ml Detection limit in the test cell:N(c)min = 1 cfu/test cell Detection limit of the sample:N(0)min = N(c)min/V(0) N(0)min = 1/V(0) cfu/ml Do not forget: In the low microbial concentration range the probability of the detection is highly affected by the test volume.

Linearity of membrane filtering

Detection of microbial contamination Sampling and testing the product To find the defective unit and detect the contamination Distribution of micro-organisms in the product Contagious distribution (б 2 >µ) Sporadic occurrence of defective units Main problem is to find the defective units Random distribution (б 2 =µ) Main problem is to detect the low microbial count Basic assumption: Even one viable cell results in positive test.

Effect of the test volume on the detection Legends N s : average microbe-concentration of the sample (cfu/ml) V s : sample-volume (ml) n : sample size V i : The total volume tested V i = V s · n N i : Inoculated total cell number in the all tests (cfu) N i = N s ·V i

Probability of positive test Zero tolerance, positive test is not allowed The probability of n negative test: The probability of minimum 1 positive test:

Comparison of the classical and redox methods At a given microbial concentration the effectiveness of the testing depends on the filtered volume: V i = V s ·n Example for mineral water testing: Vs = 250 ml/sample Classical membrane filtration, 1 membrane for 3 samples 1 Petri dish for 1 membrane = 3 samples Microtester method with normal loading 1 membrane for 4 samples 1 test cell for 5 membranes = 20 samples

Probability of positive test

Presence/Absence tests bottles tested for Coliform (09 Aug 2005) Method of Laboratory, Tergitol agar, 24 Petri dishes Membrane filtering 3 x 250 ml with 1 filter. Placing 1 filter in a Petri dish One Petri dish represents 3 bottlesAll negative Detection threshold: 1 microbe/750ml Redox potential method, BBL broth, 6 Channels, Membrane filtering 3 x 250 ml with 1 filter. Placing 4 filters in a test cell. One test cell represents 12 bottlesAll negative Detection threshold: 1 microbe/3000ml Positive control: 1 ml Citrobacter freundii suspension (logN = 3.66)

Advantages of the redox method in the evaluation of membrane filtration The time requirement of the redox-potential technique is significantly lower than that of the classical nutrient methods. While the classical methods use only 1 membrane in 1 Petri dish the redox-potential method makes possible to evaluate even 5 or more filters in one test cell. That means not only a 5 times lower detection limit of microbes but results in a remarkable cost reduction as well.