Personalised eye modelling for customised intraocular lens designs Matthew Sheehan, Eamonn O’Donoghue, Conor Sheil and Alexander Goncharov Photonics Ireland,

Slides:



Advertisements
Similar presentations
Accommodative and Multifocal IOLs
Advertisements

Toric and Modern IOL Technology
IN THE NAME OF GOD.
Comparison of intraocular lens power calculation formulas with LENSTAR LS 900® Tsunekazu Hamada Hamada Eye Clinic, Osaka, Japan Disclosure statement of.
Comparison of Visual Outcomes With Toric IOL and With Limbal Relaxing Incisions in Cataract Surgery Eriko Fukuyama, MD Fukuyama Eye Clinic Fukuoka, Japan.
Monovision for Presbyopia Insert name/ Practice name/ Logo here if desired.
Accuracy of Predicted Refractive Error in Resident-Performed Cataract Surgery Using Partial Coherence Interferometry Nickolas P. Katsoulakis, M.D., Paul.
Eugene Ng, Arthur B. Cummings, Patrick P. Collins, Alexander V. Goncharov, Diana Bogusevschi, Chris Dainty, Michael C. Mrochen. The authors of this paper.
Wavefront-Guided Laser Surgery. 2 How the eye works Light rays enter the eye through the clear cornea, pupil and lens. These light rays are focused directly.
Dominic McHugh MD FRCS London, UK
State-of-the-art Vision Correction
Cataract Eye Surgery Which procedure is best for you ?
Yüksel Totan, Ramazan Yaĝcı, Zeynel Arslanyılmaz, Uĝurcan Keskin The authors have no financial interest.
Progressive Multifocal Intraocular Lens G. Rubiolini M.D. Italy Disclosure of finanacial interest Author's research is partially funded.
Intacs Insert name/ Practice name/ Logo here if desired.
By Kelsey Matthews. History  LASIK stands for laser in situ keratomileusis  Developed in 1991 by a greek doctor Ioannis Pallikaris  Purpose to correct.
Phakic IOL. 2 How the eye works Light rays enter the eye through the clear cornea, pupil and lens. These light rays are focused directly onto the retina,
Choosing the Proper Power for the IOL
IOL power calculation after refractive surgery A. Peyman, MD.
Refractive Lens Exchange. 2 How the eye works Light rays enter the eye through the clear cornea, pupil and lens. These light rays are focused directly.
Phacoemulsification with Goniosynechialysis in the Management of Refractory Acute Angle-closure Glaucoma Ghasem Fakhraie*, MD, Mahmoud Jabbarvand, MD,
Placement of Toric Intraocular Lens and the Long-term Change in the Axis of Corneal Astigmatism after Sutureless Cataract Extraction by Phacoemulsification.
Incisional Procedures Insert name/ Practice name/ Logo here if desired.
JAIRO E. HOYOS, MD MELANIA CIGALES, MD Instituto Oftalmológico Hoyos Barcelona - SPAIN.
Hong Kong Eye Hospital Biometry Audit 2012 SN60WF IOL Dr. Rose Chan
Phacoemulsification in eyes with previous anterior chamber phakic IOL surgery Walton Nosé, MD, PhD 1,2 Adriana dos Santos Forseto, MD 1 Mariana Ávila,
Correlation Between Corneal Biomechanics and Wavefront Aberrations Alejandro Rivera, MD Private Practice Mexico City The author has no financial interest.
Hong Kong Eye Hospital Ms Frenchy Chiu Dr Victoria Wong IOL master
Hong Kong Eye Hospital Biometry Audit 2011 SN60WF IOL Dr. Rose Chan Resident, Hong Kong Eye Hospital.
Biometric Accuracy in High Hypermetropes and Myopes
Phacoemulsification some Basic Ideas…
The authors have no financial interest in the subject matter of this poster Yinfei Xu, Peter S. Hersh, MD, David S. Chu, MD Institutional Affiliations.
Conductive Keratoplasty (CK) Insert name/ Practice name/ Logo here if desired.
Task 2 : The Eye Gan Jia Jie 2A409. Short-sightedness/Myopia  It is a condition of the eye where the light that comes in does not directly focus on the.
Glaucoma and Penetrating Keratoplasty : Incidence, Risk Factors, and Outcomes Sonika Gupta Consultant Ophthalmology Max Eye Care New Delhi, India Author.
INTRAOCULAR LENS POWER CALCULATION BY IMMERSION A-SCAN BIOMETRY VERSUS CONTACT A-SCAN BIOMETRY MEASUREMENTS BEFORE CATARACT SURGERY Burak Bilgin**, M.D.,
Sonia Yoo, MD 1 Fernanda Piccoli, MD 1 Artur Schmitt, MD 1 Takeshi Ide, MD 1 Tsontcho Ianchulev, MD 2 Authors have no financial interest in this subject.
Jamie Ng, Marcus Tan, Lennard Thean National University Health System
Partial Coherence Interferometry Failure Rate in a Teaching Hospital Leslie A. Wei 1,2, BA, Nickolaus P. Katsoulakis 2, MD, Theodoros Filippopoulos 3,
The Effect of Corneal Anterior Surface Eccentricity on Astigmatism after Cataract Surgery Choul Yong Park MD 1 Sung Jun Lee MD 1 Prabjot Channa MD 2 Roy.
Multifocal Intraocular Lenses Abdullah Al-assiri Mansour Farooqui Abdulrahman Al-Muammar Saudi Ophthalmology Meeting 2009.
10 year follow up of LASIK surgery for low to high levels of myopia Qasim Qasem FRCS, Caitriona Kirwan MRCOpth, Michael O’Keefe FRCS. Institutional Affiliations:
IOL Calculations Based on Partial Biometry in Humanitarian Missions Joseph Schmitz, MD Kimberly Davis, MD, FACS Scott McClatchey, MD The authors have no.
DR. TEJAS D. SHAH AMDAVAD EYE LASER HOSPITALS PVT LTD GOOD BYE GLASSES LASER CENTRE AHMEDABAD, INDIA NO FINANCIAL INTEREST
بسم اللة الرحمن الرحيم. Limbal relaxing incisions versus penetrating limbal relaxing incisions for the management of astigmatism in cataract surgery Sara.
Comparision of ultrasound A- scan with optical A-scan Dr.Somshekar.N Consultant Refractive Services Narayana Nethralaya, Bangalore No Finanacial Interest.
Post-LASIK Intraocular Lens Power Adjustment Nomogram Joseph Diehl Kevin Miller, MD Jules Stein Eye Institute, David Geffen School of Medicine.
Management of Astigmatism - An overview
Minimizing Risk in Visian ICL Implantation.
Toric IOLs: wavefront aberrometry and quality of life Mencucci Rita Giordano Cristina, Stiko Ermelinda, Miranda Paolo, Eleonora Favuzza, Ugo Menchini Authors.
COMPARISON AND EVALUATION OF OCULAR BIOMETRY USING A NEW NON-CONTACT OPTICAL LOW COHERENCE REFLECTOMETER David Goldblum 1,3, Kaspar Rohrer 1, Rudolf Waelti.
F.I. Camesasca, MD Zeiss Invent ZO Aspheric IOL: Long-Term Results of Refractive and Aberrometric Analysis F. I. Camesasca* P. Vinciguerra.
Corneal shape and corneal aberrations after MicroIncision Cataract Surgery (MICS) NOCHEZ Y, BUREL B, MAJZOUB S, PISELLA PJ C.H.U.
John P Berdahl M.D.* David R. Hardten M.D., F.A.C.S.* *No relevant financial disclosures.
Poster# P36 Comparison of Techniques of Measuring Anterior Chamber Depth and Corneal Curvature in Indian Eyes Sujata Das, MS, FRCS Anjula Kumari, B.Optom.
Changes of Axial Length After LASIK Surgery: A 3-Year Follow-Up Study
Ever ask does anyone around here do those procedures?
Mumbaieyecarecornealasik.com.
Premium IOL May be one way to achieve the visual goals of selected patients I describe some pearls for premium IOL implantation to help ensure that we.
Corneal Pachymetry in Prediction of Refraction After Cataract Surgery
The authors have no financial interest.
Effect of Axial Length Measurement Method on Refractive Outcomes of Cataract Surgery: Real World Comparison of Partial Coherence Interferometry and Immersion.
Nienke Visser, Tos T.J.M. Berendschot, Rudy M.M.A. Nuijts
Early Experience with Descemet’s Stripping Automated Endothelial Keratoplasty Combined with Phacoemulsification: Clinical and Refractive Outcome University.
Pablo Artal, Encarna Alcón, Eloy Villegas, Carmen Cánovas, Elena Rubio
Comparison of Autokeratometry and Manual Keratometry
Mohamed A Guenena, MD Helga P Sandoval, MD, MSCR Kerry D Solomon, MD
IN THE NAME OF GOD.
성모병원 안센터 CHANGES IN ASTIGMATISM RELATIVE TO IOL HAPTIC INSERTION AXIS IN WITH-THE-RULE AND AGAINST-THE-RULE ASTIGMATISM PATIENTS Hyun Seung Kim, M.D.
Michael Goodman, Alexandra Paul and Andrew Hsu
Presentation transcript:

Personalised eye modelling for customised intraocular lens designs Matthew Sheehan, Eamonn O’Donoghue, Conor Sheil and Alexander Goncharov Photonics Ireland, Dublin, Ireland, September 7 th - 9 th 2011

History Ridley’s first intraocular lens – 1949 Kelman’s first phacoemulsification procedure First FDA approval for an intraocular lens Refractive surgery increases in popularity – 1990s Geometrical optics equations Linear regression equations Modern formula s to 1990s Intraocular lens power calculations

What lens power should we use ?

Refractive surgery popularity increases

Experiment Protocol – measurements performed pre and post cataract surgery Wavefront aberration of the eye (ZyWave) Refractive error and corneal curvature (Nidek ARK) Segmented axial length (Lenstar) Corneal topography (Atlas) Interferometry on the specific intraocular lenses (FISBA) Aims Investigate corneal shape changes due to the surgical incision Find parameters for predicting the implant resting position/depth Perform surface metrology for a specific implant design Final Goal Aquire knowledge to perform personalised eye modelling for customised intraocular lens designs

Biometry data summary 165 patients enrolled (64 males, 101 females) 33 excluded eyes 303 included suitable eyes (pre-surgery) age range: 32 to 98 years (mean 74 years) 88 eyes with usable post-surgery review data 74 eyes with usable single-echo implant data 14 eyes with usable double-echo implant data review period: 10 to 122 days (mean 31 days)

Lens implantation depth Cornea ~ 500 microns Cataractous Lens ~ 4 mm Retina ~ 200 microns Intraocular lens ~ 900 microns Vitreous ~ 16 mm

Predicting lens implantation depth

Surgery-induced corneal topography changes

Personalised eye modeling

Conclusions Early days for personalised eye modelling and customised intraocular lens designs Modern biometry instruments allow accurate measurement of two key parameters - optical segmented axial length - posterior corneal topography This methodology may be beneficial for typical cataract surgery patients as well as those with extreme ocular parameters (previous refractive surgery patients, high hyperopia)