Advantys ETB Ethernet IP67 I/O

Slides:



Advertisements
Similar presentations
Orion Telecom Networks Inc Slide 1 STM-1 63 E1 (Optical / Electrical) SDH Add-Drop Multiplexer Updated: Dec, 2010Orion Telecom Networks Inc
Advertisements

Inputs: Digital and 4 configurable for Digital or 10 bit Analog Outputs:4 - 8 amp Relays or 700ma Transistors (1 PWM) 4 Line by 18 Character fully.
Copyright © 2012 Rockwell Automation, Inc. All rights reserved. CompactLogix 5370 Programmable Automation Controllers High performance control in a compact.
MET ONE 7000 Series Remote Airborne Particle Counters Customer Name Date Presenter Presenter Title.
12-Port IP Power Manager IPM  Product Overview  Product Features  Applications  Comparison Presentation Outline 2 / 15.
Presents The Silver Family An Integrated Approach to Processors, Data Communication and Head End Integration.
Microprogrammes control the KOMBIS TMM8003. For the reliable operation of its systems and devices there are several programs located in two controllers.
ADAM-4572 Ethernet To Modbus Solution Ethernet to Modbus Data Gateway
AS-i, The Simplest Automation Networking Solution Dated: 10/30/2008.
G3 Electronics Platform Overview Presentation. G3 Electronics Platform Pneumatic Valve Side 32 Solenoid Output Capability Including Valve side Sub-D.
Notes: For the installation of a PB network, you can use shielded twisted pair copper cable, glass or plastic FO and infrared components. And you can mix.
Advantys® STB High Density Discrete I/O Modules. AGP - English 2 Advantys® STB Advantys STB delivers customer value in distributed I/O Smart Built-in.
© 2010 McQuay International 1 McQuay Delivered VAV System Product Overview October 2010.
Make the most of your energy June 2008 Power Meter 800 PowerLogic ® Power Meter 8ECC.
Kinetix 3 Component Servo Drive
Control Activity & Industry Services
TM SM Maximum Value for OEMs SM NXIO Platform from “OEMax NXIO Introduction CN rev4.ppt” Thomas Sugimoto Strategic Marketing Manager Thomas Sugimoto Strategic.
SCADA and Telemetry Presented By:.
2N® Access Commander Product presentation.
System Elements HighPoint Broadband Delivery System Sector 1 Sector 3
ASAB New Additions Extended Bypass Models Ethernet Modules Remote Control Panel.
Page 1 ADAM-6000 Web-enabled Smart I/O Γιάννης Στάβαρης Technical Manager Ιούνιος 26, 2007.
Temperature Controller DT3 Series & Delta Machine Vision Automation for a Changing World.
1 PAC530 | Output Controller. 2 The Output Controller (PAC530) provides the local connection on an RS-485 network between an Access and Alarm Server (PAC500)
XS26-2 Expandable Safety Controller.
1 Product & Technology Quality Excellence Support American Global Products Product & Technology TeSysPort Ethernet Interface for TeSys June 5, 2007.
Make the most of your energy December 2008 PM8ECC Need improved Network capabilities out of your meter? PowerLogic ® PM8ECC.
1 Quick Disconnect Power Distribution. 2 Power Distribution Methods Hardwiring o Traditional method for providing power to machines and devices o Difficult.
 AUTOMATION  PLC  SCADA  INSTRUMENTATION  DRIVES & MOTORS.
M340 Modbus Plus Proxy Link legacy systems to Ethernet
VARAN Bus Presentation 1 / 27 The VARAN BUS.
Factory benefits Hooper feed back DRAFT Hooper : “We are looking at our core business, is building machines. Factory gives the.
Internet 0 for Industrial Applications Fred Cohn 13-Dec-07.
Serial Transmission System Series EX510 BackgroundFeaturesTechnical detailsApplications.
EPack relaunch. Schneider Electric 2 -Industrial – Eurotherm – 16/12/2015 ●1. Reduce your equipment costs.
World Leaders in Combustion Management Solutions New Product Developments Autoflame Sales Meeting 2011 New Product Developments.
New product introduction:
PROGRAMMABLE LOGIC CONTROLLER
Software House iSTAR Edge August iSTAR Edge “Bringing the Power of C  CURE to the Edge” A full-featured, two-reader IP device based on the iSTAR.
Programmable Logic Controller & Distributed Control System Yoon-Je Choi 17 th June 2006.
LEADING THE PACK.
FLATPACK Rev.5 September 2002 Updated versions may be available.
CompactLogix Controllers Portfolio
Top 10 Differentiators.
An Overview When Connecting to Yaskawa Drives Date: 8/14/06, Rev: PP.AFD.26.
Seminar on "PLC” (Programmable Logic Controller)
ESX10-T Electronic Circuit Protectors with Hazardous Area approvals.
Serial / Ethernet Converter - IE-CS-2TX-XRS232/485
Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. PUBLIC PUBLIC CO900H L06 - Developing Safety Applications Using the Guardmaster®
A Competitive Overview Jon Cramer and Steve Floth Regional Sales Managers.
Modular C ontroller S eries Product Introduction.
2016. The primary objective of AIM is to create focus for our electronic channel partners on select products from the DC organization through two synergistic.
ControlLogix Portfolio
Industrial communication networks
SGC-250 Synchronous Generator Controller
IP-based 8-port Switched Power Manager
Reveal™ Touch Screen Product Overview
The VARAN Bus.
Programmable Logic Controllers (PLCs) An Overview.
StorFly-IES Intelligent External Storage for Industrial-IoT ®
NT24k® & 1000 PoE+ Offerings October 2016.
Product Training Module
Integrated gateway-server
Day 2 Training - Technical
PowerLogic™ offer for the basic metering market
Detailed information FOR INTERNAL USE ONLY! CUBE20.
Presentation transcript:

Advantys ETB Ethernet IP67 I/O

Advantys ETB Introducing Schneider Electric’s new family of IP67 rated I/O modules that connect to Ethernet.

Advantys ETB Ethernet IP67 I/O modules Direct connection to the Ethernet network with models that support: Ethernet Modbus TCP/IP Protocol EtherNet/IP Protocol Direct mounting on equipment, eliminates need for enclosures IP67 rated modules suited for harsh environments Complete product offer with a full set of power, sensor, and Ethernet cables and accessories

Product overview Product features & specifications System view Competitive position Cost comparisons Customer values

Product overview 16 Point Digital Modules: available types 16 digital Inputs 12 Inputs/ 4 Outputs @ 2 Amps 8 Inputs / 8 Outputs @ 2 Amps 16 digital Inputs/Outputs configurable Ethernet Protocols supported EtherNet/IP Modbus TCP/IP Protection Level, IP67 Watertight Extended Operating Temp. - 25°C to + 70°C Built-in 2 port switch for Daisy Chain Connection Integrated Web Server Scrolling LED Display

Product overview Modbus TCP/IP EtherNet/IP ETB 1EM 16C POO 16 point module, configurable as inputs or outputs ETB 1EM 16E PPO 16 point input module ETB 1EM 12E 04S PPO 12 point input / 4 point output module ETB 1EM 08E 08S PPO 8 point input / 8 point output module EtherNet/IP ETB 1EI 16C POO 16 point module, configurable as inputs or outputs ETB 1EI 16E PPO 16 point input module ETB 1EI 12E 04S PPO 12 point input / 4 point output module ETB 1EI 08E 08S PPO 8 point input / 8 point output module

Product overview Product Features 2- Power connections, type 7/8 threaded connectors 8 – Input/ Output point ports, 2 I/O points per connector, for M12 threaded and Ultra-Lock connectors Scrolling 4 digit LED Display 2 – Switched Ethernet communication ports, for M12 threaded and Ultra-Lock connectors

Product overview Complete Product Offer – Cables and Accessories Power Cables Available in versions with connector at each end or with single connector at one end for connection to Power Supply. 4 Pin connector versions for EtherNet/IP 5 Pin connector versions for Modbus TCP Sensor Cables Available in versions with M12 threaded connectors or with quick release Ultra- Lock connectors. Also available are splitter cables to connect 2 sensors to a single I/O port. Ethernet Communication Cables Available in versions with an RJ 45 connector at one end and an M12 connector at other end, or versions with 2- M12 connectors. (Note: The cable jacket material is approved for both the European and North American markets)

Product overview Module with cables and accessories Power Supply Cables to additional modules Power Tee Processor Splitter Cable to sensors Power Supply Ethernet Cable Adapter Ethernet Cable to connect next module Power Receptacle Enclosure

Target markets for IP67 I/O Installed Base Customers - Automotive Machining Component Assembly Body Assembly Food and Beverage Bottling Packaging Material Handling Other Mining, Minerals, & Metal – Material Handling Printing Pulp & Paper – Pulping Paper Machine Wet End

Target markets for IP67 I/O Where to use Ethernet IP67 rated I/O Modules Harsh Environments that include: Oil and/or water spray Extended operating temperature -25 to + 70°C High vibration and shock I/O Modules must or can be mounted directly on equipment Field devices are located near I/O Modules, no long wire runs There is no space available for I/O cabinets at location Need to reduce the cost and time to install the I/O modules Field devices selected are available with M12 connectors Customers are using Ethernet as their industrial communication network

Product overview Product features & specifications System view Competitive position Cost comparisons Customer values

Product features Built for operation in harsh environments Benefit IP67 Rated Module Package, Connectors, and Cables Extended Operating Temperature Range -25°C to + 70°C Flexible Mounting System Benefit Watertight, can be used in locations with oil and water spray Used on plant floor or outdoors Mounts directly on equipment – no need for enclosure

Product features Reduced installed cost – Ethernet Switch Built-in 2 Port Unmanaged Ethernet Switch with cross-over capability - allows daisy chain connections for Ethernet with no need for external switches Daisy-chain connection for Power Supply Power Supply Daisy Chain connection – Up to 10 Modules Processor Ethernet

Product features Reduced Installed Cost - M12- Ultra-Lock quick release Connector Faster and easier to connect then standard threaded M12 Easy to connect – even when difficult to access Snap on for IP67 sealing of connections Standard M12-connectors can also be used on modules

Product features Reduced Installed Cost – Built-in Display with Control Buttons 4-Character LED Display allows diagnosis without additional tools Shows Current IP Address Displays IP Address Configuration Mode Control Buttons for Setting IP Address in Static Mode Displays Errors Network functions are displayed (e.g. ping)

Product features Reduced Installed and Operating Cost – Integrated Web Server provides the following capabilities Password Protection for Security Module Configuration - IP Address, Module Parameters, and WDT Error behavior Module Status Information Remote Access and Diagnosis via Web – Interface No additional software tool needed for configuration and diagnosis

Product features Module diagnosis Output Power Power present Power not connected Module & Input Power Power present Power not connected Input / Output Input / Output on Input / Output failed Input / Output off Ethernet Port 100MBit Communication 10MBit Communication Display with information about Ethernet address, IO & watchdog status

Module specifications Common specifications for all modules Number of I/O Points 16 Digital Points per Module I/O Configurations 16 Inputs 12 Inputs / 4 Outputs 8 Inputs / 8 Outputs 16 I/O Points, User configurable I/O Points per Connectors 2 Points Power Requirements 24 VDC – Module and Input Power 13 to 28 VDC, 8 amp max. Outputs Input Type Compatible with Contact and 3 wire devices Input Delay 2.5 ms default, user configurable Output Current 2 amps per Output, 8 amps per Module Output Protection Electronic Short Circuit Protection Max. Switching Frequency 200 Hz Short Circuit Current 6.5 Amps (typical)

Module specifications Common specifications for all modules (continued) Operating Temperature -25°C to + 70°C ( -4° to + 158°F) Storage Temperature -40°C to + 85°C ( -40° to + 185°F) Protection IP67 according to IEC 60529 Vibration IEC 60068-2-8 Mechanical Shock 10G, 11 ms, 3 axis MTBF 100,000 Hours Power Connectors 7/8 Connectors, 5 pin for Modbus TCP/IP 4 pin for EtherNet/IP Ethernet Connections M12 and Ultra-Lock Connectors, 4 pin I/O Connectors M12 and Ultra-Lock Connectors, 5 pin

Product overview Product features & specifications System view Competitive position Cost comparisons Customer values

Typical system configuration Ethernet (Modbus TCP/IP) based control system using a combination of IP67 and IP20 I/O PC/ Supervisory System Ethernet Switch/ M1 Processor Advantys ETB IP67 I/O mounted on equipment Advantys STB IP20 I/O mounted in cabinets

Typical system configuration Control system topology for EtherNet/IP network PLC or IPC EtherNet/IP Switch Advantys ETB IP67 I/O mounted on equipment

Typical system configuration Ethernet (Modbus TCP/IP) modules can be used with the following Schneider control systems: Quantum system with NOE Ethernet interface Premium system with ETY Ethernet interface M340 system with NOE Ethernet interface Momentum system using M1E Ethernet processors

Typical system configuration EtherNet/IP modules can be used with the following Schneider control systems along with other control systems: Quantum system with NOC Ethernet interface Premium system with ETC Ethernet interface Rockwell ControlLogix and CompactLogix systems = opportunity at competitive accounts

Typical I/O configuration Advantys ETB I/O has the flexibility to be installed in the following configurations: Daisy Chain Star Combination

Typical I/O configuration Daisy Chain I/O configuration Where to use Systems with I/O count under 160 I/O points Installations where I/O blocks are within 5 meters of the next block Applications where installed cost is an issue Advantages Lower installed cost Eliminates external switch Easy to expand system Simplified troubleshooting and maintenance Limitations Up to 10 modules per Daisy Chain Disconnecting 1 module will shut down the following modules in the daisy chain

Typical I/O configuration Star configuration Where to use Systems with large number of I/O points Installations where the I/O is not concentrated in one area Applications where system will be changing, with modules added, disconnected and reconnected to the network Advantages Large number of modules per system (limitation is number of switches) Flexible module location Disadvantages Higher installed cost, switches Longer cable runs, adds complexity Maintenance requires additional effort

Typical I/O configuration Combination of Star and Daisy Chain configuration Where to use Large systems with multiple machine or work areas Advantages Segments modules into groups for each area Simplifies installation and troubleshooting Has lower installed cost than Star only network Disadvantages Most effective for larger systems

Typical field devices Advantys ETB I/O can connect directly to sensors and field devices that are available with M12 connectors and are IP67 rated. Schneider Electric Sensors include: -Osiprox XS6 and XS8 Inductive Sensors -Osiris XUB Photoelectric Sensors -PhotoVirtu XUN Teachable Sensors -VM1 Ultra Sonic Sensors For the full range of Schneider Electric sensors, please visit our web site: http://www.sensors.com/

Product overview Product features & specifications System view Competitive position Cost comparisons Customer values

Competitive advantages Built-in Ethernet Switch Save time and money by eliminating the need for external switches to connect modules Integrated Web Server Simplifies Module Configuration & Diagnostics No Additional Software Required 4 Character Display Real Time Ethernet and Diagnostic Information Quick Release Connectors Fast connection to communications, and field devices

Competition

Product overview Product features & specifications System view Competitive position Cost comparisons Customer values

IP67 I/O cost advantages Lower installed cost No need for cabinet or enclosure Plug-in cables for Power, I/O, and Ethernet Communications Simplified configuration via Web Pages or HMI Display Total Installed Cost €825.70 €655.00 Traditional I/O System Advantys ETB I/O I/O Modules Terminal Blocks Wiring Duct Field Sensors and Actuators

Installed cost comparison 16 I/O points Traditional I/O system (IP20) includes the following; NEMA 4 metal enclosure 16”x12”x8” 2 wires per device Wiring from I/O module to Terminal blocks Wiring from Terminal blocks to Field Devices Power Wiring coming from outside 24 VDC Power Supply Mounting I/O Module and Terminal Blocks Labels for all wires Advantys ETB IP67 Rated I/O modules includes the following Power, Sensor, and Ethernet Cables Labor to install 10 threaded type connectors into module Not included in the installed cost comparison I/O Modules, power supply, sensors or actuators Labor to mount I/O module or enclosure on machine

Installed cost comparison Advantys ETB IP67 vs IP20 26% lower installed cost for Advantys ETB I/O Summary of installed cost for 16 I/O points on Ethernet: Advantys ETB IP20 I/O Module cost (net)…….. €216.00 €204.00 Installation cost………. €439.00 €671.70 Total cost €655.00 €809.70 = €170.70 less

Installed cost comparison 16 I/O points

Product overview Product features & specifications System view Competitive position Cost comparisons Customer values

Customer values Simple Installation Easy to Configure I/O mounted directly on equipment eliminates the need for enclosures Quick Release Connectors allow fast connection to power, communications, and field devices Direct Connection to Ethernet Network without the need for external switches Easy to Configure Built-in Ethernet Switch for Network connections Web Pages and Display simplifies integration and commissioning Solution Approach Can be combined with Schneider PLC’s, sensors, actuators, drives, and IP20 I/O for a total control system package Complete solution with cables and accessories