Chapter 13 An Introduction to Ultraviolet/Visible Molecular Absorption Spectrometry Absorption measurements based upon ultraviolet and visible radiation.

Slides:



Advertisements
Similar presentations
Spectrophotometer.
Advertisements

An introduction to Ultraviolet/Visible Absorption Spectroscopy
SPECTROSCOPY.
7. Beer’s Law and It’s Implications for Instrument Construction.
UV-vis. Applications Quantitative analysis Organics (if composition is simple and known) Specific binding to chromaphore Metal-ligand absorption (d-orbital.
Spectrophotometry Chapter 17, Harris
Spectroscopy Chapter 7.
Spectrophotometric Analysis
Introduction to Spectrophotometry
Reflection and scattering losses with a solution contained in a typical glass cell. Losses by reflection can occur at all the boundaries that separate.
Chapter 24 Introduction to Spectrochemical Methods
UV/Visible Spectroscopy
Introduction to Spectrophotometry
Molecular Spectrometry (UV and Visible) Part 1: Absorption.
AN INTRODUCTION TO ULTRAVIOLET/VISIBLE ABSORPTION SPECTROSCOPY
Chapter 2 Quantitative.
Ultraviolet – Visible Spectrophotometer. What is UV – Vis spectroscopy? Ultraviolet – visible spectroscopy is a measure of the absorbance of radiation.
Introduction to Instrumental Analysis - Spectrophotometry
1.1 Range of molar absorptivity
Spectrophotometer Prof.Dr. Moustafa M. Mohamed Vice Dean Faculty of Allied Medical Science Pharos University in Alexandria, EGYPT.
Introduction to Spectroscopic Methods Chapter 6 Instrumental Analysis.
Fluorometric determination of riboflavin
10/11/ ENGINEERING RESEARCH CENTER FOR S TRUCTURED O RGANIC P ARTICULATE S YSTEMS RUTGERS UNIVERSITY PURDUE UNIVERSITY NEW JERSEY INSTITUTE OF TECHNOLOGY.
Fluorometric determination of riboflavin. Introduction.
Chem. 31 – 4/1 Lecture.
Simple Double Beam Spectrometer
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 19 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
1 UV-Vis Absorption Spectroscopy Lecture Multichannel Instruments Photodiode array detectors used (multichannel detector, can measure all wavelengths.
Chapter 13 An Introduction to Ultraviolet- Visible Molecular Absorption Spectrometry.
Lecture 2 INTRODUCTION TO SPECTROMETRIC METHODS Copyright ©The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
Spectrophotometry.
Chapter 6 An Introduction to Spectrometric Methods Spectrometric methods are a large group of analytical methods that are based on atomic and molecular.
Introduction to Spectroscopic Methods of Analysis (part 2)
Introduction to Spectrophotometry
1 UV-Vis Absorption Spectroscopy Lecture Measurement of Transmittance and Absorbance: The power of the beam transmitted by the analyte solution.
Introduction to Spectrochemical Methods
UV-VIS Spectroscopy Dr. AKM Shafiqul Islam.
Spectrophotometer.
SPECTROPHOTOMETRY. Principle : there is interaction between the light and sample particle, spectrophotometer is employed to measure the amount of light.
1 Atomic Emission Spectroscopy Molecular Absorption Spectroscopy Lecture 21.
1 Atomic Emission Spectroscopy Lecture Qualitative analysis is accomplished by comparison of the wavelengths of some emission lines to standards.
Summary: (Last lecture) Absorption spectroscopy definition electromagnetic spectroscopy matter absorption spectroscopy fundamental terms (transmittance,
Photometry.
Fluorometric determination of riboflavin
Measuring Enzyme Activity Using Spectrophotometry (Beer’s Law)
Introduction to Spectrochemical Methods
11 Instrumental Analysis Tutorial Use mathematical formulae to calculate absorbance, transmittance of a sample and wave parameters. Determine factors.
1 Instrumental Analysis Tutorial 2. 2 Objectives By the end of this session the student should be able to: 1.Describe the grating principle of work. 2.Describe.
Introduction to Spectrophotometry
UV/Visible Spectroscopy
UV/VIS SPECTROSCOPY.
Chem. 133 – 3/14 Lecture.
Spectroscopy Techniques
Beer-Lambert law Gihan Gawish.Dr.
Principles and practice of Spectrophotometer
Introduction to Spectrophotometry
Estimation of analyte concentration on the basis of light absorption
Chapter 13 Chapter 13 Chapter 13 Chapter 13 Chapter 13 Chapter 13
Introduction to Spectrophotometry
Spectrophotometer Dr . S. Jayakumar.
Measurements involving light –A Basic Principles and Instrumentation
Instrumental Chemistry
Colorimeters OR photometers
SPECTROPHOTOMETRY Applied Chemistry.
Spectrophotometer.
Advanced Pharmaceutical Analysis UV spectroscopy
Spectrophotometry A method to determine concentration of a species exploiting the absorption of EMR.
Spectrophotometric Analysis
Presentation transcript:

Chapter 13 An Introduction to Ultraviolet/Visible Molecular Absorption Spectrometry Absorption measurements based upon ultraviolet and visible radiation find widespread application for the quantitative determination of a large variety species. Beer’s Law: A = -logT = logP 0 /P =  bc A = absorbance  = molar absorptivity [M -1 cm -1 ] c = concentration [M] P 0 = incident power P = transmitted power (after passing through sample)

Measurement of Transmittance and Absorbance: The power of the beam transmitted by the analyte solution is usually compared with the power of the beam transmitted by an identical cell containing only solvent. An experimental transmittance and absorbance are then obtained with the equations. P 0 and P refers to the power of radiation after it has passed through the solvent and the analyte.

Derivation of Beer’s Law: Sample cell with absorbing molecules P0P0 P b=0b=b db PP-dP

dP  PIncremental power lost  power in; i.e., increase power in, increase power absorbed dP  dbLonger pathlength, greater number of molecules in incremental slice and more power absorbed Therefore,dP  Pdb dP = -kPdb k = proportionality constant (function of, c) negative sign: because power is lost (i.e., absorbed) Rearrange:

Integrate: Factor out concentration part of k: k = k”c Convert fraction (remove –sign) and change In to log: (1/2.303)k” = 

Application of Beer’s Law to Mixtures Beer’s law applies to a medium containing more than one kind of absorbing substance. Provided there is no interaction among the various species, the total absorbance for a multicomponent system is given by A total = A 1 + A 2 + … + A n =  1 bc 1 +  2 bc 2 + … +  n bc n where, the subscripts refer to absorbing components 1, 2, …, n.

Assumptions in derivation of Beer’s Law Monochromatic incident radiation (all molecules absorb light of one ) Absorbers independent (Absorbing molecules act independently of one another i.e, low c) Pathlength is uniform (all rays travel the same distance in sample) No scattering Absorbing medium is optically homogeneous Incident beam is not large enough to cause saturation All rays should be parallel to each other and perpendicular to surface of medium.

Limitations (deviations) of Beer’s Law High concentration (close proximity of molecules affects absorption) Analyte dissociation to product with different absorption characteristics (e.g., pH-dependent indicators)

Polychromatic radiation (i.e., light of more than one ) Where P’ and P” are powers for ’ and ”, respectively –Negative deviation = lower absorbance than predicted because higher transmittance –Higher T because molecules don’t absorb one as well as other

Stray radiation Ps = power from stray radiation Extra light hits detector  higher T; lower A

Instrumentation Light source - selection Sample container Detector Signal processing Light Sources (commercial instruments) –D 2 lamp (UV: 160 – 375 nm) –W lamp (vis: 350 – 2500 nm)

- selection (monochromators) Sample holders –Cuvettes (b = 1 cm typically) –Glass (Vis) –Fused silica (UV 350 nm) Detectors –Photodiodes –PMTs

Single beam –Place cuvette with blank (i.e., solvent) in instrument and take a reading  100% T –Replace cuvette with sample and take reading  % T for analyte (from which absorbance is calc’d)

Double beam (most commercial instruments) –Light is split and directed towards both reference cell (blank) and sample cell –Two detectors; electronics measure ratio (i.e., measure/calculate absorbance) –Advantages: Compensates for fluctuations in source and drift in detector Better design for continuous recording of spectra

Multichannel Instruments Photodiode array detectors used (multichannel detector, can measure all wavelengths dispersed by grating simultaneously). Advantage: scan spectrum very quickly “snapshot” < 1 sec. Powerful tool for studies of transient intermediates in moderately fast reactions. Useful for kinetic studies. Useful for qualitative and quantitative determination of the components exiting from a liquid chromatographic column.