MALDI-TOF-TOF with High Resolution Precursor Selection and Multiplexed MS-MS Poster Number ThP 618 Kevin Hayden, Stephen C. Gabeler, Mark Dahl and Marvin.

Slides:



Advertisements
Similar presentations
High Performance MALDI MS, MS/MS, and Multiplexed MS/MS Tissue Imaging
Advertisements

Spectral Resolution and Spectrometers
Module 2: Analytical methods and separation techniques.
Inductively Coupled Plasma Mass Spectrometry or ICP-MS
Spectral Resolution and Spectrometers A Brief Guide to Understanding and Obtaining the Proper Resolution of the 785 Raman System.
Oligonucleotide analysis by Linear MALDI-TOF mass spectrometry Stephen J. Hattan , Kenneth C. Parker, Marvin L. Vestal; SimulTOF Systems, 60 Union Ave,
Introduction to MALDI-TOF MS
1 Extreme Ultraviolet Polarimetry Utilizing Laser-Generated High- Order Harmonics N. Brimhall, M. Turner, N. Herrick, D. Allred, R. S. Turley, M. Ware,
Lecture 9. MALDI/TOF. Introduction Matrix-assisted laser desorption/ionization (MALDI) is a soft ionization technique used in mass spectrometry, allowing.
Mass Spectrometry in Life Science: Technology and Data-Evaluation H. Thiele Bruker Daltonik, Germany.
High Performance MALDI-TOF Mass Spectrometry Marvin Vestal and Kevin Hayden Virgin Instruments Corp. Sudbury, MA.
Development of TOF-MS from intellectual curiosity to practical technique Marvin Vestal SimulTOF Systems The Jim Waters Symposium at PittCon March 2, 2014.
Mass Spectroscopy Mass Spectrometry ä Most useful tool for molecular structure determination if you can get it into gas phase ä Molecular weight of.
Chem. 133 – 5/7 Lecture. Announcements I Exam 3 on Tuesday (will give summary of material to know later) Format will be similar to other exams I will.
Mass Analyzers Double Focusing Magnetic Sector Quadrupole Mass Filter Quadrupole Ion Trap Linear Time-of-Flight (TOF) Reflectron TOF Fourier Transform.
Mass Analyzers Double Focusing Magnetic Sector Quadrupole Mass Filter Quadrupole Ion Trap Linear Time-of-Flight (TOF) Reflectron TOF Fourier Transform.
A Miniature Ion Mobility Spectrometer for Explosives Detection Andrew Goodin, William F. Siems, Christina L. Crawford, Prabha Dwivedi, and Herbert H. Hill,
PROTEIN IDENTIFICATION BY MASS SPECTROMETRY. OBJECTIVES To become familiar with matrix assisted laser desorption ionization-time of flight mass spectrometry.
Mass Labels While Mass Spectroscopy is not covered in our texts, other mass/density dependent technologies including X-ray Spectroscopy, Gamma Spectroscopy,
Mass Spectrometry.
Development of a TOF Version of the Desktop MiniSIMS Design & Applications A.J. Eccles, B. Cliff, C. Jones, N. Long, P. Vohralik Millbrook Instruments.
4. Mass Spectrometry Objectives:
Evaluated Reference MS/MS Spectra Libraries Current and Future NIST Programs.
Tryptic digestion Proteomics Workflow for Gel-based and LC-coupled Mass Spectrometry Protein or peptide pre-fractionation is a prerequisite for the reduction.
Comparison of chicken light and dark meat using LC MALDI-TOF mass spectrometry as a model system for biomarker discovery WP 651 Jie Du; Stephen J. Hattan.
PC4250 Secondary Ion Mass Spectrometry (SIMS). What is SIMS? SIMS is a surface analysis technique used to characterize the surface and sub-surface region.
The HERMES Dual-Radiator Ring Imaging Cerenkov Detector N.Akopov et al., Nucl. Instrum. Meth. A479 (2002) 511 Shibata Lab 11R50047 Jennifer Newsham YSEP.
Marvin Vestal and Kevin Hayden Virgin Instruments Corp. Sudbury, MA
Mass spectrometry and the PITZ Sven Lederer Technisches Seminar
Tissue Imaging with New MALDI-TOF(TOF) Instrumentation Presented at MSIA 2013 Vanderbilt University April 17,2013 Marvin Vestal, CSO.
Molecular mass spectrometry Chapter 20 The study of “molecular ions” M + e -  M e -
Tissue Imaging by 5 kHz High-Performance MALDI-TOF Poster Number TP191 Christina Vestal 1, Kenneth Parker 1, Kevin Hayden 1, George Mills 1, Marvin Vestal.
Quantitative Chemical Analysis Seventh Edition Quantitative Chemical Analysis Seventh Edition Chapter 22 Mass spectrometry Copyright © 2007 by W. H. Freeman.
INF380 - Proteomics-61 INF380 – Proteomics Chapter 6 – Mass Spectrometry – MALDI TOF The MALDI-TOF instruments are the simplest MS instruments suitable.
Mass Analyzers IV Quadrupole Ion Traps Chem 5181 – Fall 2007 J. Kimmel.
Marvin Vestal and Kevin Hayden SimulTOF Systems
Overall efficiency and speed of analysis – key factors are ions per sample molecule desorbed and ions produced per laser pulse Precision and accuracy of.
Untargeted Metabolomics: Tandem LC-MSMS. Column and Flow Rate Selection Insert Barnes table for flow rates and sensitivity gain. Reverse Phase and Normal.
MS Calibration for Protein Profiles We need calibration for –Accurate mass value Mass error: (Measured Mass – Theoretical Mass) X 10 6 ppm Theoretical.
A new "Molecular Scanner" design for interfacing gel electrophoresis with MALDI-TOF ThP Stephen J. Hattan; Kenneth C. Parker; Marvin L. Vestal SimulTof.
MS Intro. MS requires gas-phase ions, why? MS uses magnetic and electric fields to control the path of a compound based on mass to charge ratio (m/z)
Temple University MASS SPECTROMETRY FURTHER INVESTIGATIONS Ilyana Mushaeva and Amber Moscato Department of Electrical and Computer Engineering Temple University.
For all CHEM5161 students: The first day of class for CHEM5161 (Analytical Spectroscopy) will be on TUE Sept 4 (following Labor Day). There will be no.
INF380 - Proteomics-51 INF380 – Proteomics Chapter 5 – Fundamentals of Mass Spectrometry Mass spectrometry (MS) is used for measuring the mass-to-charge.
The Future of Time-of-flight Mass Spectrometry
Mass Analyzers : Time-of-flight Mass Spectrometry CU- Boulder CHEM 5181 Mass Spectrometry & Chromatography Joel Kimmel Fall 2007.
F LORIDA I NTERNATIONAL U NIVERSITY Advanced Mass Spectrometry Piero R. Gardinali/Yong Cai/ Bruce McCord Revised on August 23, 2009.
A versatile MALDI target plate based on polymer-filled reticulated vitreous carbon foam ThP Stephen J. Hattan ; Jie Du; Kenneth C. Parker VIC Instruments.
Comparison of Laser Interferometry and Atom Interferometry for Gravitational Wave Observations in Space Peter L. Bender JILA, University of Colorado Boulder.
Separates charged atoms or molecules according to their mass-to-charge ratio Mass Spectrometry Frequently.
Quantitative MALDI-TOF for Clinical Applications.
Quantification of Albumin and Creatinine in Urine by MALDI-TOF Mass Spectrometry Jane Y. Yang, David A. Herold Department of Pathology, University of California.
Chem. 133 – 4/26 Lecture. Announcements Return graded quiz and additional problem Lab – Lab report deadlines (2:4 – Thursday) Today’s Lecture – Mass Spectrometry.
2014 생화학 실험 (1) 6주차 실험조교 : 류 지 연 Yonsei Proteome Research Center 산학협동관 421호
Constructing high resolution consensus spectra for a peptide library
Chapter 29 Mass Spectrometry. 29 A Principles of mass spectrometry In the mass spectrometer, analyte molecules are converted to ions by applying energy.
What is Mass Spectrometry? Mass spectrometry could be considered as an analytical technique that involves the study in the gas phase of ionized molecules.
RANIA MOHAMED EL-SHARKAWY Lecturer of clinical chemistry Medical Research Institute, Alexandria University MEDICAL RESEARCH INSTITUTE– ALEXANDRIA UNIVERSITY.
Yonsei Proteome Research Center Peptide Mass Finger-Printing Part II. MALDI-TOF 2013 생화학 실험 (1) 6 주차 자료 임종선 조교 내선 6625.
Metabolomics Part 2 Mass Spectrometry
Acknowledgements Slides and animations were made by Dr. Jon Karty Mass Spectrometry Facility Indiana University, Bloomington.
Old Dominion University, Norfolk, Virginia 23529, USA
Tandem MS.
Time of Flight Analyzers
Presented by: Nigel Chou and Vivian Hecht December 9, 2011
Starter Complete the quiz and hand in..
Mass Spectroscopy. Mass Spectroscopy Mass Spectrometry Most useful tool for molecular structure determination if you can get it into gas phase Molecular.
Schematic of MS1 filtering.
Mass Spectrometry THE MAIN USE OF MS IN ORG CHEM IS:
Hybrid MS instruments including TOF analyzers
Presentation transcript:

MALDI-TOF-TOF with High Resolution Precursor Selection and Multiplexed MS-MS Poster Number ThP 618 Kevin Hayden, Stephen C. Gabeler, Mark Dahl and Marvin Vestal. Virgin Instruments Corp., Sudbury, MA. Introduction A new MALDI-TOF-TOF instrument has been developed to overcome the limitations of current tandem MALDI-TOF instruments. The first TOF provides high resolution precursor selection and efficient transfer of selected ions to the fragmentation region. A new pulsed accelerator following precursor selection focuses precursor ions at the second pulsed accelerator for MS- 2. An RF-excited octopole is incorporated into the collision region to enhance fragment ion transmission, and a second pulsed accelerator and a second two-stage ion mirror refocus ions at the detector to provide high sensitivity, high resolution, and excellent mass accuracy for both collision-induced and unimolecular fragmentation. The ion source employs a 5 kHz laser and the pulsed accelerator operates asynchronously at speeds up to 50 kHz. Data acquisition is up to 250 times faster than conventional MALDI-TOF-TOF instruments operating at 200 Hz. Method The new instrument was designed using a recently developed theoretical approach for optimizing the performance of each of the major elements of a MALDI-TOF mass spectrometer. These elements include one and two-stage MALDI ion sources, two-stage ion mirrors, both gridded and gridless, timed-ion selectors, ion focusing and deflecting elements, pulsed and static ion accelerators, ion fragmentors, and ion detectors. The prototype instrument was constructed to allow performance of each of these elements to be evaluated and compared with theoretical predictions. In this prototype an ion detector can be temporarily placed at any of the critical points in the ion flight path for thorough evaluation of ion beam properties and functionality of critical components. The addition of the pulsed accelerator following precursor selection allows simultaneous optimizaton of the performance of both MS-1 and MS-2. Design of the System The system comprises a two-stage pulsed MALDI source, a first two-stage gridded mirror, a Bradbury-Nielson TIS gate, a first pulsed accelerator, a field-free fragmentation chamber, a second pulsed accelerator, a second two-stage mirror and a detector. The amplitude and delay of the accelerating pulse in the ion source are adjusted to focus ions in time at a first focal point, and ions are refocused by the first ion mirror at the B-N gate. Ions selected by the gate are accelerated by the first pulsed accelerator, fragmented in the fragmentation chamber, and selected precursor ions and their fragments are accelerated by the second pulsed accelerator, separated in the second ion mirror and detected. Conclusions and Future Work Selection of single isotopes with resolving power of 4000 has been demonstrated with negligible losses in sensitivity or leakage of neighboring isotopes. The ability to select up to 10 peaks per laser shot in the mass range between 0.5 and 2.5 kDa has also demonstrated. A new pulsed accelerator following the TIS narrows the velocity distribution at the entrance to MS-2 by more than an order of magnitude allowing high resolution measurements of fragment spectra in MS-2. The complete TOF-TOF system incorporating these advance has been assembled and is currently being tested. Reference: 1. M. L. Vestal, “Modern MALDI Time of Flight Mass Spectrometry” J. Mass Spectrom. 44, (2009). Acknowldgements Contributions to this work from the entire staff of Virgin Instruments is gratefully acknowledged. This work was supported by the National Institutes of Health NIGMS under grant GM Figure 1. Schematic diagram showing layout of new TOF-TOF for high resolution precursor selection and multiplexed MS-MS measurements. Standard ion optical elements for focusing and deflecting ions are included to provide high transmission efficiency and to correct for trajectory errors 1. Figure 2. Potential diagram with focusing parameters and focal points for 2-stage MALDI I on source. High resolution spectra of BSA digest from MS-1 with detector at normal position of timed ion selector. Resolving power is typically 20,000 in agreement with theory for effective length of 2000 mm In these measurements the detector is located at the normal location for the pulsed accelerator that accelerates precursors and fragments for analysis in MS-2. Addition of the first pulsed accelerator refocuses selected ions at the second accelerator and allows high resolution performance for both MS-1 and MS-2. BSA digest peptides detected without selection and without velocity focusing Multiplex selection of 4 major peptides from BSA digest without velocity focusing. 60 nsec Multiplex velocity focusing BSA peptides without TIS selection. Note inversion of the isotope distributions. The broad peaks are masses thatare those not accelerated Selection of individual isotopes of with both TIS and velocity focusing. Note selection of with very low noise. Comparison of single isotope peaks with and without velocity focusing Theory of velocity focusing by pulsed accelerator Potential diagram for second leg of TOF-TOF for multiplex operation with high resolution both for precursor selection in MS-1 and fragment spectra in MS-2. In the first series of experiments the detector was located at the TIS and in the second series at the second pulsed accelerator. The velocity spread at the TIS is p 1 =(dv/v) 1 =v 0 DT/2d 1 y and the velocity spread after acceleration in the pulse accelerator is p 2 =(dv/v) 2 where p 2 /p 1 =[V 0 /V a -D 1 /2d] /[1+V 0 /V a ] where d is the length of the accelerator, D 1 is the distance from the TIS to the accelerator V 0 is the initial energy and V a is the energy added by the accelerator. If p 1 /p 2 is negative the velocity focusing occurs at D 2 =D 1 (-p 1 /p 2 )(1+V a /V 0 ) 1/2 For this case d=6, D 1 =50, D 2 =800, V a /V 0 =0.26 and p 2 /p 1 = Thus the velocity spread is reduced by about a factor of 14 in good agreement with experimental results. Calculated ratio of velocity spread vs position in the accelerator at the time the pulse is applied.