Demonstration and comparison of photomultiplier tubes operation at liquid Argon Temperature Ettore Segreto LNGS (Italy) On behalf of the WArP Collaboration.

Slides:



Advertisements
Similar presentations
Kathleen Chinetti Sohaila Mali Calibrating Equipment for the Direct Detection of Dark Matter using Noble Element. Scintillation.
Advertisements

ATLAS Tile Calorimeter Performance Henric Wilkens (CERN), on behalf of the ATLAS collaboration.
TPB aging LNGS Ettore Segreto LNGS, Italy.
DMSAG 14/8/06 Mark Boulay Towards Dark Matter with DEAP at SNOLAB Mark Boulay Canada Research Chair in Particle Astrophysics Queen’s University DEAP-1:
Prototype of the Daya Bay Neutrino Detector Wang Zhimin IHEP, Daya Bay.
Reflectivity Measurements of Critical Materials for the LUX Dark Matter Experiment Theory My experiment was a cyclic process involving software, engineering,
S. Bricola, A. Menegolli, M. Prata, M.C. Prata, G.L. Raselli, M. Rossella, C. Vignoli INFN and University of Pavia - Via Bassi, 6 – Pavia – Italy.
Calibration of the 10inch PMT for IceCube Experiment 03UM1106 Kazuhiro Fujimoto A thesis submitted in partial fulfillment of the requirements of the degree.
GAMMA RAY SPECTROSCOPY
The UC Simulation of Picosecond Detectors Pico-Sec Timing Hardware Workshop November 18, 2005 Timothy Credo.
Proportional Light in a Dual Phase Xenon Chamber
Scintillation Detectors
1 Light Collection  Once light is produced in a scintillator it must collected, transported, and coupled to some device that can convert it into an electrical.
Measurement of Kr background in the XMASS experiment ICRR master’s course in physics Keisuke Hieda 1.
Photon detection Visible or near-visible wavelengths
The Transverse detector is made of an array of 256 scintillating fibers coupled to Avalanche PhotoDiodes (APD). The small size of the fibers (5X5mm) results.
Test of Silicon Photomultipliers (SiPM) at Liquid Nitrogen Temperature Yura Efremenko, Vince Cianciolo nEDM CalTech Meeting 02/14/2007.
Catania VLVnT09 Athens, Greece 1/14 Catania Performances of four super bialkali large area photomultipliers with respect to.
Report on SiPM Tests SiPM as a alternative photo detector to replace PMT. Qauntify basic characteristics Measure Energy, Timing resolution Develop simulation.
1 Performance of multi-anode PMT employing an ultra bi-alkali photo-cathode and rugged dynodes Takahiro Toizumi Tokyo Institute of Technology S. Inagwa.
Cube Measurements Tent Crew. Scintillation BNL 241 Am Semi- collimated  Spectralon Diffuse UV Reflector SBD  -Trigger Scint. Light Poisson.
1 Max-Planck-Institut fuer Physik, Muenchen, Germany, 2 Humboldt-Universituet Berlin, Germany, 3 Univ. Complutense, Madrid, Spain, 4 ETH, Zurich, Switzerland,
Founded in 1906 by Nahum Kolmanok; 1913 – merging with bulb factory “Light”. As a result, “Russian electric lamp” manufacture was established; 1921 –
TAUP2007, Sendai, 12/09/2007 Vitaly Kudryavtsev 1 Limits on WIMP nuclear recoils from ZEPLIN-II data Vitaly A. Kudryavtsev Department of Physics and Astronomy.
QUPID Readout and Application in Future Noble Liquid Detectors Kevin Lung, UCLA TIPP 2011 June 11, 2011.
Improved PMTs for the Cherenkov Telescope Array project Razmik Mirzoyan for the Focal Plane Instrumentation WG Max-Planck-Institute for Physics Munich,
J.T. White Texas A&M University SIGN (Scintillation and Ionization in Gaseous Neon) A High-Pressure, Room- Temperature, Gaseous-Neon-Based Underground.
DarkSide: a Free Background Experiment Maria Bossa LNGS Seminar IPRD13 Oct 10, 2013.
1 Satoshi Mihara for the   e  collaboration, review meeting at PSI, Jul 2002 Photon Detector Satoshi Mihara ICEPP, Univ. of Tokyo 1.Large Prototype.
Techniques for Nuclear and Particle Physics Experiments By W.R. Leo Chapter Eight:
Status of the PMT light detection system Gian Luca Raselli 20-AUG-2015 ICARUS executive meeting.
Catania 11 ICATPP october, 2009 Como 1/12 Catania Comparative measurements of the performances of four super bialkali large.
WIMP search Result from KIMS experiments Kim Seung Cheon (DMRC,SNU)
? At Yangyang beach, looking for something in the swamp of particles and waves. 1 The recent results from KIMS Seung Cheon Kim (Seoul National University)
Cold PM test at Indiana final measurements, September 9 – 24, 2007 PM under test: Hamamatsu R7725 serial # ZK3692 (tube with Pt underlayer) Hans-Otto Meyer.
Lecture 3-Building a Detector (cont’d) George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
Current status of XMASS experiment 11 th International Workshop on Low Temperature Detectors (LTD-11) Takeda Hall, University of Tokyo, JAPAN 8/1, 2005.
DARK MATTER SEARCH Carter Hall, University of Maryland.
Characterization of the QUartz Photon Intensifying Detector (QUPID) Artin Teymourian UCLA Dark Matter Group Dept. of Physics and Astronomy.
HBD Transmission Monitor Update III: Noise Analysis B. Azmoun & S. Stoll BNL HBD Working Group Meeting 10/10/06.
Lecture 12  Last Week Summary  Sources of Image Degradation  Quality Control  The Sinogram  Introduction to Image Processing.
1 A two-phase Ar avalanche detector with CsI photocathode: first results A. Bondar, A. Buzulutskov, A. Grebenuk, D. Pavlyuchenko, R. Snopkov, Y. Tikhonov.
The VSiPMT: A new Generation of Photons Detectors G. Barbarino 1,2, F. C. T. Barbato 1,2, R. de Asmundis 2, G. De Rosa 1,2, F. Di Capua 1, P. Migliozzi.
R&D Plan on Light Collection Takeyasu Ito Los Alamos National Laboratory.
VUV-VIS optical characterization of Tetraphenyl-butadiene films on glass and specular reflector substrates from room to liquid Argon temperature F. Cavanna.
Characterization of Hamamatsu R12199 PMTs Oleg Kalekin KM3NeT Meeting CPPM, Marseille
CaMoO 4 at low temperature - LAAPD and PMTs - Woonku Kang, Jungil Lee, Eunju Jeon, Kyungju Ma, Yeongduk Kim Sejong University for KIMS collaboration Double.
M EASURING L IGHT G UIDE P ERFORMANCE IN L IQUID A RGON Jarrett Moon Massachusetts Institute of Technology FNAL New Perspectives – 6/9/15.
Study of the cryogenic THGEM-GPM for the readout of scintillation light from liquid argon Xie Wenqing( 谢文庆 ), Fu Yidong( 付逸冬 ), Li Yulan( 李玉兰 ) Department.
Study of the Radiation Damage of Hamamatsu Silicon Photo Multipliers Wander Baldini Istituto Nazionale di Fisica Nucleare and Universita’ degli Studi di.
Proposal for the after-pulse effect suppression  Observation of pulses and after-pulses  Shape measurement  Algorithm  Results  Efficiencies for after-pulse.
WIMPs Direct Search with Dual Light-emitting Crystals Xilei Sun IHEP International Symposium on Neutrino Physics and Beyond
 13 Readout Electronics A First Look 28-Jan-2004.
Study of cryogenic photomultiplier tubes for the future double-phase cryogenic avalanche detector. Budker INP A.Bondar, A.Buzulutskov,A.Dolgov, E.Frolov,
The Electromagnetic Calorimetry of the PANDA Detector at FAIR
Ultra fast SF57 based SAC M. Raggi Sapienza Università di Roma
MoNA detector physics How to detect neutrons. Thomas Baumann NSCL.
Scintillation Detectors
A First Look J. Pilcher 12-Mar-2004
Upgrade of LXe gamma-ray detector in MEG experiment
Instrumentation for Colliding Beam Physics 2017
Directional Optical Module Integration
Upgrade of LXe gamma-ray detector in MEG experiment
Department of Physics and Astronomy,
MEG実験の液体Xe検出器について 東大 ICEPP  森研究室 M1 金子大輔.
SPECTROPHOTOMETRY Applied Chemistry.
Development of hybrid photomultiplier for Hyper-Kamiokande
Photomultiplier (PMT) Tubes
Gain measurements of Chromium GEM foils
The Development of a Segmented Detector using ZnS:Ag/6Li
Presentation transcript:

Demonstration and comparison of photomultiplier tubes operation at liquid Argon Temperature Ettore Segreto LNGS (Italy) On behalf of the WArP Collaboration

Introduction Direct Dark Matter search in the form of WIMPs requires to detect very low nuclear recoil energies (few KeV). Liquid Argon based detectors reveal the recoil detecting the scintillation light following energy deposition. Light red-out is mainly performed by means of photomultiplier tubes (PMTs). A new type of PMT has been recently developed by Hamamatsu Photonics (Mod. R11065) which pushes the Quantum Efficiency up to 35% at liquid Argon temperature (87 o K). Within the on-going R&D activity of the WArP Collaboration (WIMP Argon Program at LNGS, ), a first set of R11065 PMTs has been subject to a series of tests aiming at their characterization in reference working conditions We operated the PMTs immersed in the liquid and optically coupled to LAr cells of various size. A comparison of the R11065 Hamamatsu PMT with a former generation of cryogenic PMT produced by Electron Tubes Limited - Mod. ETL D750 (currently in use with the WArP -100 detector) has been also carried out. 10/06/11Ettore Segreto - TIPP 20112

New high QE Hamamatsu PMT Box&Linear-focused 12-stages PMT Synthetic Silica 3” window (cut-off around 160 nm) Working temperature down to -186 ° C QE ≥ 420 nm Bialkali cathode without Pt underlayer High Collection Efficiency of photoelectrons at first dynode (above 95% with ΔV K-D1 >300Volt) Voltage divider custom made on a G10 printed circuit (according to Hamamatsu specifications) Box&Linear-focused 12-stages PMT Synthetic Silica 3” window (cut-off around 160 nm) Working temperature down to -186 ° C QE ≥ 420 nm Bialkali cathode without Pt underlayer High Collection Efficiency of photoelectrons at first dynode (above 95% with ΔV K-D1 >300Volt) Voltage divider custom made on a G10 printed circuit (according to Hamamatsu specifications) 310/06/11Ettore Segreto - TIPP 2011

Single PMT test PTFE cell containing 0.7kg of LAr (cylinder shaped h=9cm Φ=8.4cm) observed by one 3” R11065 PMT. Scintillation photons of LAr are in the VUV range (around 127 nm) and with two (main) different time constants (τ S ≃ 5 ns for the fast component and and τ T ≃ 1.3 μs for the slow component). Internal surfaces of the cell covered with reflective foils coated by a wavelength shifter -> TPB (peak emission 440 nm); Multi-layer plastic mirror (3M-VIKUITI ESR) with high specular reflectivity in the visible (~ 99%) ✚ TPB film obtained by deposition with vacuum evaporation technique (about 300 μg/cm2); 4 PTFE cell PMT Photocathodic coverage 12% Experimental set-up LAr filtered during filling (Oxisorb and Zeolite) 10/06/11Ettore Segreto - TIPP 2011

DAQ and calibration PMT anode current transmitted to a fast Waveform Recorder (Acqiris, DP235 Dual-Channel PCI Digitizer Card2, 1 GS/s, 8 bit dynamic range) => signal waveform recorded with 1 nsec sampling time over a full record length of 15 μs; Detector exposed to a 241 Am source with monochromatic γ-emission at keV; For each source run a Single Photo-electron Response (SER) spectrum is computed. 1 PHEL 2 PHEL SER spectrum The mean value of the 1PHEL peak is proportional to the actual gain of the PMT and gives the calibration constant per single photo-electron single electron average WFM 10/06/11Ettore Segreto - TIPP 20115

Gain, Peak to Valley and Resolution Gain Peak to Valley ReolutionSER stabilitty G=5x Volt P/V ≃ nominal gain R ≃ nominal gain slightly decreasing exponential trend (τ ≃ 35 h) attributed to residual effects of thermalization of the PMT at LAr temperature. 10/06/11Ettore Segreto - TIPP 20116

Light Yield measurement LY measurement performed by exposing the detector to the 241 Am monochromatic γ-source (59.54 keV); Pulse amplitude spectrum in photo-electrons obtained by waveform integration and application of the calibration factor determined by SER fit; Result fully compatible with MonteCarlo expectation based on standard assumptions Light Yield very stable during the test: fluctuations within ±1.5% Test repeated after few weeks (same PMTs, same TPB coated reflector surfaces) -> LY measurements fully confirmed this result. 10/06/11Ettore Segreto - TIPP 20117

Two-PMTs test: ETL vs HAMAMATSU comparison A second test (mid 2010) for a direct comparative test of two types of PMTs: 3” HQE Hamamatsu R11065 (the same used in the previous test) and 3” ETL - D750 (pre-production series of the PMT in the WArP -100 experiment); LAr volume viewed simultaneously by the two PMT => comparison of the light outputs independent from the actual detector conditions; A PTFE cell, about 0.4 lt of internal volume (h=8.0 cm and φ=7.6 cm), lined with a TPB coated reflector layer on the lateral; Signals from each PMT were directly recorded by the 8-bit Fast Waveform 13Digitizer Acqiris board (DP235) at 1 GHz over a 15μs time interval (as for the single PMT test); Data treatment and the off-line analysis code -> same as in the single PMT test. 10/06/11Ettore Segreto - TIPP 20118

Single Electron Response of the two PMTs Single photo-electron waveforms SER stability Peak to 3.7×10 6 gain Very similar pulse shapes for single electron; The gain of the ETL PMT showed a steeper decreasing trend. The gain of the Hamamatsu PMT has a slight decrease over the first day after activation and then stabilized to a constant value. 10/06/11Ettore Segreto - TIPP 20119

Light Yield measurement LYs determined by exposure to the 241 Am gamma- source (59.54 keV) 172 phel 52 phel The Hamamatsu-to-ETL ratio of LY found in the 3 : 1 range consistent with the ratio of the QE LYs stable during the test HMMTS/ETL 10/06/11Ettore Segreto - TIPP

Four-PMTs test The scaling-up capability of the implemented technology tested with a detector about ten times bigger than the one with one PMT; The WArP 2.3l prototype used for this test (4.3 liters internal volume)-> equipped with 4 HQE Hamamatsu PMTs R11065 (photo-cathodic coverage ~ 12 %) ; Internal surfaces covered with VIKUITI ESR reflector layer + TPB (density about 300 μg/cm 2 ) PMT windows naked (no wavelength-shifter); 4 PMT anode signals directly digitized by two Acqiris Boards (Mod. U 1080 A, 2-chs. each with 8-bit dynamic range and 1GS/s) at 1 ns sampling time over 15 μs time interval; All internal component 80 o C; Detector housed in a low-radioactivity stainless steel vessel deployed in a LAr open bath; Detector completely filled with LAr -> PMTs’ bases immersed; LAr filling through an in-line filter (Oxygen reactant and molecular sieve); No electric field; PMTs 3x10 6 gain (around 1400 Volt). 10/06/11Ettore Segreto - TIPP

Data Analysis and Results (I) Detector exposed to 241 Am, 133 Ba, 57 Co and 137 Cs sources 241 Am source – bkg subtracted LY = 6.35 phel/KeV ± 5% Detector geometry is a scaled- down version of the WArP -100 detector (100 lt of active volume, 37 PMTs, ∼ 12% of photo-cathodic coverage); The LY from this detector test can be assumed as predictive of the LY from the WArP 100 Inner Detector, when operated under equivalent conditions. LY determined with other sources less accurate but fully compatible with 241 Am value 10/06/11Ettore Segreto - TIPP

Data Analysis and Results (II) Light Yield stability LY stable within 2%; One PMT has a systematic lower light yield -> not yet understood (PMTs have almost the same Quantum Efficiency); With four PMTs working in the same way -> LY ≃ 6.6 phel/keV Slope of the slow scintillation component: 1130 ns (1300 nsec for clean Argon). This reduces the light yield of about 10%. Direct measurement with mass spectrometer showed the presence of ~ 1 ppm of N 2 (not captured by our filters); In case of clean Argon the LY would have been in the range of 7 phel/KeV. Average waveform  slow  = 1130 nsec 10/06/11Ettore Segreto - TIPP

Conclusions 10/06/11Ettore Segreto - TIPP A new PMT type with enhanced Quantum Efficiency photo- cathode and operating at LAr temperature has been developed by Hamamatsu Photonics Mod. R11065 with peak QE up to about 35%. PMT’s of this type have been extensively tested along with the R&D program of the WArP Collaboration; The main working parameters of this PMT were measured at LAr temperature and its great performances have been clearly demonstrated; Liquid Argon detectors with HQE photo-cathodic coverage in the 12% range can achieve a light yield around 7 phel/keV (at null electric field), sufficient for detection of events down to few keV of energy deposition -> suited for direct Dark Matter searches with LAr-based experiments.