PH/DT MCP & MNO NEW MAGNET SAFETY SYSTEM HARDWARE Sylvain Ravat PH-DT Xavier Pons PH-DT.

Slides:



Advertisements
Similar presentations
Controller Tests Stephen Kaye Controller Test Motivation Testing the controller before the next generation helps to shake out any remaining.
Advertisements

Melting Probe IWF-EXP/ÖAW GRAZ Size: 40 x 40 x 195 mm Mass w/o electronics Calculated: 450g Measured: 350g, 3m tether Main Components Cable.
LP33 Series UPS kVA 400Vac/CE
HPS MPS OVERVIEW Dan Sexton & the Safety Systems Group JLAB 1.
I have almost 20 years experience in the components and devices used in industrial control, instrumentation and automation applications. Before I came.
Presents The Silver Family An Integrated Approach to Processors, Data Communication and Head End Integration.
LHC UPS Systems and Configurations: Changes during the LS1 V. Chareyre / EN-EL LHC Beam Operation Committee 11 February 2014 EDMS No /02/2014.
MICE Electronics Update Mice Target Workshop – Dec 2010 P J Smith James Leaver.
RPC Electronics Overall system diagram –At detector –Inside racks Current status –Discriminator board –TDC board –Remaining task.
ESE Lab Computer based Temperature Control Sid Deliwala, ESE Labs.
DP Cabinet.
Termination Boards Dynamic Positioning Cabinet. Termination Boards Overview The termination Boards provides the connections between the field and the.
MUST HAVE SHOULD HAVE COULD HAVE Module # 010. Qi Hardware Objectives Recognize hardware Know how to interface to field equipment Know the 4 different.
Vegard Joa Moseng BI - BL Student meeting Reliability analysis summary for the BLEDP.
PH/DT MCP & MNO Xavier Pons on behalf of MCP team – 25/03/2013.
1 Modular DC/DC Converter. 2 PSC W Standard 19“ rack 4U – 6 prewired slots (single DC input/output connection for each unit)
Bonitron Air Demand Scheduler Design Review Vanderbilt Senior Design Alex Brown Ajmer Dwivedi Cory Haugh February 04, 2008.
PH4705/ET4305: A/D: Analogue to Digital Conversion Typical Devices: Data sheets are on the web site for A/D 8 bit parallel AD7819 and serial ADC0831 And.
TF Joint Voltage Drop Instrumentation Robert Marsala (609) Hans Schneider (609) Engineering Operations August 7, 2003 TF_JOINT_Final_Design_Review.ppt.
15. CBM Collaboration Meeting, GSI, Darmstadt, April 12–16, 2010 Status of Front End Electronics N-XYTER PCBs & Power Supply Volker Kleipa, GSI Darmstadt.
Power Supply Controller Architecture
1 Digital Voltage Transducer family DV from 1200 to 4200 V RMS DVL from 50 to 2000 V RMS.
Iowa LED system for CMS HCAL By M. Miller Y. Onel University of Iowa, Iowa City, IA CMS Meeting, CERN December 1-8, 2001.
Electronics for PS and LHC transformers Grzegorz Kasprowicz Supervisor: David Belohrad AB-BDI-PI Technical student report.
Confidential / Property of Danfoss Drives A/S DKDD-SMC 1 Drives Division Danfoss presents - VLT ® 2800 Series.
DCS TCSG November 10th 1999, H.J.Burckhart1 Status of the general purpose I/O system LMB u DCS Architecture u LMB u Local Monitor Box (LMB) u Concept u.
Technical Training. 1 Configuration: 2558 Analog Input Module 1. Select voltage or current input mode for each channel 3. Select digital filtering, offset.
Preliminary measurements for the 8 channel prototype of SPD discriminator ASIC I.The 8 channel prototype. II.Status of the test. III.Noise. IV.Gain. V.Test.
PH4705/ET4305: Analogue Multiplexer An Analogue Multiplexer is simply a switch that connects multiple analogue inputs signals to a single output one at.
Front End DAQ for TREND. 2 Introduction: analog part 2015, feb 10 th.
MSS2 HARDWARE ASSEMBLY  FROM LAURENT DERONT. FORMAT STANDARD 6U CRATE  1 ST BACKPLANE INTERFACE CONNECTOR DB37 (Front side) TO DIN (Back Side) 1.
1 ATF2 Q BPM electronics Specification (Y. Honda, ) Design System –Hardware layout –Software –Calibration Testing Production schedule ATF2 electronics.
ATLAS ATLAS DCS B.Hallgren, CERN EP/ ATI PRR CERN 4 March the Embedded Local Monitor Board ELMB Design description of the Embedded Local Monitor.
Acquisition Crate Design BI Technical Board 26 August 2011 Beam Loss Monitoring Section William Vigano’ 26 August
Costas Foudas, The Tracker Interface to TCS, The CMS Silicon Tracker FED Crates What goes in the FED Crates ? What do we do about the VME controller.
1/12/2010 R. CIARANFI 1 NEW NINO BOARD FOR RICH OLD AND NEW LOGISTIC NEW BOARD DESCRIPTION NEW MODULARITY 32 CH NEW FORM FACTOR FRONT END AREA AND DAQ.
GIF++ Control System (GCS) Gilles MAIRE PH-DT-DI1.
1 Chang Shuan Electronics Co., Ltd
TE-MPE Annual Meeting Activity report of EM section 11/12/2015 Betty Magnin.
1 BROOKHAVEN SCIENCE ASSOCIATES Power Supply Status George Ganetis Power Supply Status ASAC Review October 22-23, 2009.
MCP Status Magnet Control Project - MCP Common systems: MCS – Magnet Control System – S. Ravat MDS – Magnet Diagnostics System – S. Ravat MSS – Magnet.
Technology Department 1 ELENA Fast Deflectors status Nicolas Voumard, Jan Schipper TE/ABT/EC TCM 17/11/2015 1/11.
E.Sbrissa EP/TA3 - IC ATLAS EDR_MAG Magnet Project Fault analysis, QA & Failure rate.
Brandon Halleran.  The power supply for your personal computer gives your machine all the different voltages it needs to operate properly. It is able.
ATLAS DCS Workshop on PLCs and Fieldbusses, November 26th 1999, H.J.Burckhart1 CAN and LMB in ATLAS u Controls in ATLAS u CAN u Local Monitor Box u Concept.
PC COMPONENTS. System Unit Cases This is the cabinet that holds the main components of a computer. It includes a plastic front panel for aesthetic purpose.
Design summary Status of the development & production - test run with S3a and S3b prototype - performance tests To do list for production & development.
Current Status of QBPM Electronics and Magnet Movers D. McCormick, J Nelson, G White SLAC S Boogert Royal Holloway Y. Honda, Y.Inoue KEK.
Electrical Configuration and System Protection
PADME Front-End Electronics
LHCb Outer Tracker Electronics 40MHz Upgrade
A. Aloisio, R. Giordano Univ. of Naples ‘Federico II’
ProtoDUNE SP – Slow control temperature gradient monitor
Setup for automated measurements (parametrization) of ASD2 chip
ECAL front-end electronic status
ProtoDUNE SP – Slow control Status
Analog FE circuitry simulation
Block Diagram Transmitter Receiver × 2 Transmitter Power Supply ADC
Ideas and design concepts, and challenges
R&D of neutrino beam production for future (Multi-)MW proton facility:
AC Inlet & AC Input Filter
Focus Coil Quench Detector
Gif++ Annual meeting 28/06/2017
Magnet Safety System for NA61/Shine
Radiation- and Magnet field- Tolerant Power Supply System
NI Data Acquisition (DAQ) Wiring and Connections
Series 5300 Lithium Cell Formation System
RPC Electronics Overall system diagram Current status At detector
FPGA Vinyl to Digital Converter (VDC)
SKAMP Square Kilometre Array Molonglo Prototype
Presentation transcript:

PH/DT MCP & MNO NEW MAGNET SAFETY SYSTEM HARDWARE Sylvain Ravat PH-DT Xavier Pons PH-DT

MSS2 PH/DT MCP & MNO HARDWARE ARCHITECTURE Interface: Digital Input Analogue Input Interface: Digital Output Magnet Output signals cRIO FPGA Magnet input signals MSS2 Environment

MSS2 Main crate Following L. Deront design 6U crate size for 19’ rack assembly compatible with all MSS cRIO FPGA installed in the front side Input/Output Interface board in the back side Redundant Power supply MSS2 Prototype PH/DT MCP & MNO MSS2 cRIO crate. Front Side view MSS2 cRIO crate. Front Back Side view

HARDWARE ARCHITECTURE. DIGITAL INPUT INTERFACE CARD Capacity up to 32 DI Inputs Capacity to deliver 32 copy DI Inputs to MCS Isolated to 5.3 kV, by dual optocoupler ILD615 Redundant DC-DC converter EDMS MSS2 DI board

HARDWARE ARCHITECTURE. DIGITAL OUTPUT INTERFACE CARD Capacity up to 16 Digital Outputs Delivers 16 Copy Digital Outputs Process 16 Digital Internal MSS Inputs PCB safety relays according EN50205 Isolation 6 kV coil-contacts Redundant DC-DC converter Includes 2 fast Digital Outputs adapted for CIBU BEAM_PERMIT signal processing EDMS MSS2 DIDO board

HARDWARE ARCHITECTURE. DIGITAL OUTPUT INTERFACE CARD FOR MSS APC CRATE Capacity up to 16 Digital Outputs Delivers 16 Copy Digital Outputs Process 16 Digital Internal MSS Inputs Allows keeping the MSS APC crate EDMS MSS2 DIDO board for MSS APC crate MSS APC crate

HARDWARE ARCHITECTURE. ATLAS AND CMS MAGNET TYPE DIGITAL INPUT/OUT AND ANALOGUE INPUT SIGNALS ANALOGUE INPUT INTERFACE BOARD Dual Analogue Input Range Multiple signal range, hardware programmable range: x1, x10, x100, x1000 set by DIP switch. Signal isolation 1500Vrms. Power supply circuit isolated 3 kV by DC- DC converter between channel - channel- FPGA_AI - Power_Supply Each channel has its own selectable current source by DIP_SWITCH mA, 0.1 mA, 1mA, 10 mA. From Texas Instruments Ap. Notes Optional low pass filter Optional gain and offset adjustment Time and level discrimination done at FPGA level EDMS MSS2 Analogue Input interface board

HARDWARE ARCHITECTURE. ATLAS AND CMS MAGNET TYPE ANALOGUE INPUT CRATE ANALOGUE INPUT INTERFACE BOARD Capacity Up to 8 dual analogue input board = 16 AI channels Signal connectivity up to 3 kV Cable trace signal Independent Power supply Signals connected to cRIO-FPGA crate by passive board/cable MSS2 Analogue Interface crate front side MSS2 Analogue Interface crate back side

MSS vs MSS2 DIGITAL INPUT CIRCUIT MSS digital Input MSS2 digital Input

MSS vs MSS2 DIGITAL OUTPUT CIRCUIT MSS digital Output MSS2 digital Output

MSS2 Beam Dump Circuit

MSS2 Current source circuit mounted in the analogue input interface board

MSS2 DIP switch options