HEALTH MATE HEALTH MATE Wireless Health Monitoring System.

Slides:



Advertisements
Similar presentations
V i t a l i s ECE Spring 2013 TEAM 13 Presenter: Aakash Lamba Wireless Biometric Sensor Team Members: Aakash Lamba Di Mo Shantanu Joshi Yi Shen Patent.
Advertisements

Tri-Band RF Transceivers for Dynamic Spectrum Access By Nishant Kumar and Yu-Dong Yao.
ABSTRACT Annually, heart disease causes over 17 million deaths worldwide. One of the best ways of getting preventive prognoses is to use electrocardiograms.
Low Cost Wearable Monitoring System (Advisor Dr.Assim Sagahyroon ) By: Ali Hazem Umair
Team 7 / May 24, 2006 Web Based Automation & Security Client Capstone Design Advisor Prof. David Bourner Team Members Lloyd Emokpae (team Lead) Vikash.
Gary MKIII University of Central Florida Chris Valle, Braden Urban, John Rowe, and Tyler Yoemans.
Wearable Wireless Physiological Sensors Daniel Bishop Rosy Logioia Josh Handley Gouri Shintri Phillip Hay Clay Smith Christina Hernandez Adam Stevenson.
Remote Medical Inc. ENSC 440 Project Presentation Presented By: Marian Chang Calvin Che Lotus Yi Dong Zhang April 7 th 2005.
Wireless Sensor Network. A wireless sensor network (WSN) is a wireless network consisting of spatially distributed autonomous devices using sensors to.
Team Impact Intelligent Helmet Impact System Preliminary Design Review January 29 th, 2008 Amanda Brodbeck Wei-Chu Liao Wei-Shen Liao Chris Mintle.
Background S.A.U.V.I.M. Semi - Autonomous Underwater Vehicle for
Wireless Thermal Protection Sensors Presented By: Jesse Pentzer and Lucas Wells Brandy Holmes John Sochacki Chris Johnson.
Healthnet John Bauman Kyunghwan Choi Adam Goldhammer Eugene Marinelli.
Electrical and Computer Engineering PeopleFinder Vitaly Gordievsky Alex Trefonas Scott Richard Matt Beckford Midway Design Review.
Electrical and Computer Engineering PeopleFinder Vitaly Gordievsky Alex Trefonas Scott Richard Matt Beckford Comprehensive Design Review.
EE 396 Project Icarus Preliminary Design Review September 22, 2007 Group Members: Jeremy Chan Eric Lee Sae Yoon.
A Framework for Patient Monitoring A. L. Praveen Aroul, William Walker, Dinesh Bhatia Department of Electrical Engineering University of Texas at Dallas.
Wireless Data Acquisition for SAE Car Project by: J.P. Haberkorn & Jon Trainor Advised by: Mr. Steven Gutschlag.
Wearable Wireless Physiological Sensors Josh Handley Rosy Logioia Gouri Shintri Clay Smith.
● To make a presentable way to show the nurse the information on each patient that needs to be monitored ● We take data from the sensors taken from the.
Building an Application Server for Home Network based on Android Platform Yi-hsien Liao Supervised by : Dr. Chao-huang Wei Department of Electrical Engineering.
Team Members Jordan Bennett Kyle Schultz Min Jae Lee Kevin Yeh.
Internet Piloted Blimp Alfredo Guevara, Jr. Advisor: Professor Spinelli March 1, 2008.
A Mobile Wireless Electrocardiogram System for Health Care Facilities John Farner Jason Fritts Julian Jaeger Joe Richard Georgia Institute of Technology.
Optical Heart Monitor/Jump Drive Sponsor: Calit2 Mentor: Paul Blair Ph.D. Team: Matt Chandrangsu, Jeffrey Chi, Kari Nip ECE 191 – Group 6 Fall 2008.
RaPTEX: Rapid Prototyping of Embedded Communication Systems Dr. Alex Dean & Dr. Mihai Sichitiu (ECE) Dr. Tom Wolcott (MEAS) Motivation  Existing work.
Department of Electrical & Systems Engineering GROUP #1 AUTHORS: ADVISORS: Netta Doron, CSE ’07Mr. Sid Deliwala (ESE) Kate McArdle, ESE ’07Mr. Phil Farnum.
RADIO + MCU + FLASH + USB Low-Power RF System-on-Chip
PERSONAL MEDICAL MONITOR Jason Ewing, Morgan Hinchcliffe, Dina Irgebayeva and Aida Kulmambetova.
IntroOH-1 CSE 5810 Wireless Body Sensor Networks (WBSN) in Healthcare Aljoharah A. Algwaiz Computer Science & Engineering Department The University of.
Presented by Amira Ahmed El-Sharkawy Ibrahim.  There are six of eight turtle species in Ontario are listed as endangered, threatened or of special concern.
Real-time systems Systems Refers to: (computing, communication, and information) (c) Rlamsal DWIT.
Web Interface for Health Care Database Priyanka Walke.
Wireless Sensor Monitoring Group Members: Daniel Eke (COMPE) Brian Reilly (ECE) Steven Shih (ECE) Sponsored by:
Topic 5 – Sensors and Monitoring Systems 1)TechMed scenario covers Sensors and their uses in hospitals In the scenario: “A patient-monitoring system is.
ECE 477 Design Review Group 14  Spring 2005 Paste a photo of team members here, annotated with names of team members.
Presenter : Hyotaek Shim
Cardiac Rehabilitation Equipment/Software Package Mike Bohrer.
Wearable Sensors Final Presentation Problem Background Inferred Transmission (short range) Bulky Design, hard to wear 20 Samples per second.
Wireless Sensor Monitoring Group Members: Steven Shih (ECE) Brian Reilly (ECE) Dan Eke (COMPE) Sponsored by:
Team Members: Ben Jusufovic, Ben Cao, Curtis Mayberry, Thinh Luong Advisors & Clients: Lee Harker, Jason Boyd.
Flatiron Mobile Device Security Monitor Thomas Horacek Lucas Greve.
Accessible Home Vital Signs Monitoring System
Presentation for ENSC 440/305 Instructors: Patrick Leung, Steve Whitmore Department of Engineering Science Simon Fraser University.
Founder’s Day University of Portland School of Engineering.
Heart Rate Monitor (HRM). Measurement of HR Plethysmograph or ECG techniques ECG superior as distinguishable R peak HR derived by – Sensors: Limb or.
EECS 373 Design of Microprocessor-Based Systems Mark Alitawi Sarah Spitzer Kaiyu Yan University of Michigan Radios November 27, 2012.
ICOM 5047 – Proposal – The Smart Health Station August 31, 2009 ICOM 5047 – Proposal – The Smart Health Station1 Axel Vigo Josué Acevedo Pedro J. Franceschi.
Getting started with Programming using IDE. JAVA JAVA IS A PROGRAMMING LANGUAGE AND A PLATFORM. IT CAN BE USED TO DELIVER AND RUN HIGHLY INTERACTIVE DYNAMIC.
Scott Coffin Adam Faucher Jason Graika Brian Voelz Client: Honeywell Advisor: Dr. Zhengdao Wang.
Remote Control of Home Appliances PROJECT PLAN Team: ◦ Elie Abichar –CE ◦ Chris Tefer –CE ◦ Ananta Upadhyaya.
Team Tesla.  Provide monitoring of employees with cognitive disabilities  Sense changes in position and stress levels  Easy to deploy and maintain.
AN ALTERNATIVE BIO- SPECIMEN BARCODE INITIATOR, READER AND UPDATER APPLICATION By Toluwaleke Ademuyiwa Supervisor : Prof. I.M. Venter Co-supervisor : Prof.
Cevgroup.org C utting E dge V isionaries. cevgroup.org TODAY’s TALK 1) Internet Of Things (IoT) 2) Wi-Fi Controlled Robots 3) Augmented Reality.
A Zigbee-Based Animal Health Monitoring System
BANDAGE SIZE NON ECG HEART RATE MONITOR USING ZIGBEE WIRELESS LINK Guided by,Presented by, Ms. Geo. P.G Jeevan.K.Noble Asst.Prof., ECE Dept.S7, ECE-A.
Ambulatory Foot Pressure Monitoring System David Nolan Electronic Engineering.
Introduction It’s a part of an electronic prototype that operate in MICS band Used to transfer information's regarding the patient during and after the.
ORT Braude College – Software Engineering Department WristQue: A Personal Sensor Wirstband Brian D. Mayton, Nan Zhao, Matt Aldrich, Nicholas Gillian, and.
6 th Italian Forum on Ambient Assisted Living ForItAAL 2015 “ An Open Hardware Modular Node for Wireless Body Area Networks ” An Open Hardware Modular.
TRANSMISSION LINE MULTIPLE FAULT DETECTION AND INDICATION TO EB
PRESENTATION CSE 341 MICROPROCESSOR Presented By Nabid Kaisar
By KESHAB DAS and PRITAM SARKAR INSITUTE OF RADIOPHYSICS & ELECTRONICS UNIVERSITY OF CALCUTTA.
TEAM 2 – FALL 2006 PRESENTATION 1 LPM: Ahmad Omari.
Outline Introduction Standards Project General Idea
My Big Heart: Managing Heart Failure at UCLA
WEARABLE BIOSENSOR SYSTEM USING ZIGBEE TECHNOLOGY
Zigbee Networks Using Xbee Modules
Manual Robotics ..
Portable Digital Blood Pressure Monitor
Presentation transcript:

HEALTH MATE HEALTH MATE Wireless Health Monitoring System

Outline MotivationMotivation Goals and SpecificationGoals and Specification Concept DesignConcept Design System View System View - Preliminary Design - Preliminary Design - System Models * Sensors, MCU, Wireless Comm., GUI * Sensors, MCU, Wireless Comm., GUI Future ImprovementsFuture Improvements

Motivations Improving health care:Improving health care: -Patients regain their mobility and independence. -Reducing the needed time and effort. - Minimizing the probabilities of medical errors.

Specifications & Goals low cost,small, portable, & lightlow cost,small, portable, & light Low power consumptionLow power consumption Accuracy of ± 1°C Accuracy of ± 1°C Interactive GUIInteractive GUI GUI support WindowsGUI support Windows

Design Concept Base Station (BS) Wearable Unit (WU)

System Models GUI Model Ahmad ALMuslemani Wireless Com. Model Khaleifa Zeyoudi & Ahmed AL-Katheeri MCU Model Khaled Jazzar Sensors Model Khaled ALMazrooei Health Mate View

Preliminary Design

Sensors Model * DS 1620 Digital Temperature Sensor data MCU - accuracy of ± 0.5°C - range of -55 to 125 °C - digital interface included - $ 5.75

* Polar A1 Heart Rate Monitor * Polar A1 Heart Rate Monitor MCU Heart rate comes from chest strap sensor / transmitter Signal is taken from the wrist receiver as a negative going pulse for each heart beat Signal will be conditioned using Low Pass Filter to remove noise Average taken as frequency over three samples There is a Problem !! $59.99

The Microcontroller Model The microcontroller model will collect the sensory data and create a data package to be transmitted to the host computer. The microcontroller model will collect the sensory data and create a data package to be transmitted to the host computer. Lasilky team chose AT86ZL3201 as the microcontroller chip. Why? Lasilky team chose AT86ZL3201 as the microcontroller chip. Why? The development kit for the desired microcontroller will be: STK500. The development kit for the desired microcontroller will be: STK500. The STK500 development kit gives an opportunity for designer to code on AVR. The STK500 development kit gives an opportunity for designer to code on AVR. The STK500 has features for testing new designs and developing prototypes. It also supports Atmel’s Integrated Development Environment (IDE). The STK500 has features for testing new designs and developing prototypes. It also supports Atmel’s Integrated Development Environment (IDE).

Wireless Communication Model The wireless communication model of Health Mate consists of transmitting transceiver and a receiving transceiver. The wireless communication model of Health Mate consists of transmitting transceiver and a receiving transceiver. Transceiver at the wearable unit sends the encapsulated data package processed by the MCU to the Atmel transceiver at the base station. Transceiver at the wearable unit sends the encapsulated data package processed by the MCU to the Atmel transceiver at the base station. ZigBee technology is used in the MCU, transmitting, and receiving chips. Why ZigBee? ZigBee technology is used in the MCU, transmitting, and receiving chips. Why ZigBee? Lasilky team chose AT86RF210 as the transceiver chip. Why? Lasilky team chose AT86RF210 as the transceiver chip. Why? Antenna: ANT-2.45-CHP Antenna: ANT-2.45-CHP

Graphical User Interface (GUI) Why Java? Java is object oriented language.Java is object oriented language. Java is independent of the host platform.Java is independent of the host platform. Java is considered being a higher-level language than similar languages such as C and C++.Java is considered being a higher-level language than similar languages such as C and C++. Java contains language facilities and large libraries for different network systems.Java contains language facilities and large libraries for different network systems. Java is available in most of the engineering laboratories.Java is available in most of the engineering laboratories.

The Flow Chart of the program

The Main GUI

Future Improvement Base Station (BS) Wearable Unit (WU)

Future Improvements Web Page using HTML can be easily updated and uploaded whenever there is new information.Web Page using HTML can be easily updated and uploaded whenever there is new information. -Patients will use health Mate at home -Patients will use health Mate at home -accessible at any time. -It will show the date and time of the updated process. -It will show the date and time of the updated process. -feedback by nurses. -feedback by nurses. Different sensors can be added to the system, such as a shock sensor and a blood pressure sensor.Different sensors can be added to the system, such as a shock sensor and a blood pressure sensor.

THANK YOU