American Association of Physicists in Medicine (AAPM) Task Group on Monte Carlo Validation Sets: Geant4 Related Findings Ioannis Sechopoulos, Ph.D. Assistant.

Slides:



Advertisements
Similar presentations
X Rays Medical Physics Notes.
Advertisements

Medical Imaging X-Rays I.
Radiation Interaction Q&A
BME 560 Medical Imaging: X-ray, CT, and Nuclear Methods X-ray Instrumentation Part 1.
RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
BME 560 Medical Imaging: X-ray, CT, and Nuclear Methods
Nature and origin of X-rays Interaction of X-rays with atoms
Types of Radiation Interactions All or Nothing Many Small There is a finite probability per unit length that the radiation is absorbed. If not, there is.
Experiments in X-Ray Physics Lulu Liu Partner: Pablo Solis Junior Lab 8.13 Lab 1 October 22nd, 2007.
Bruce Faddegon, UCSF Inder Daftari, UCSF Joseph Perl, SLAC
J. Tinslay 1, B. Faddegon 2, J. Perl 1 and M. Asai 1 (1) Stanford Linear Accelerator Center, Menlo Park, CA, (2) UC San Francisco, San Francisco, CA Verification.
Interaction of radiation with matter - 3
Monte Carlo model and spectral measurements of a computed tomography x-ray tube Magdalena Bazalova Frank Verhaegen.
Radiation Sources in medicine diagnostic Radiology
X-Ray Production & Emission
Theoretical calculations and simulations of interaction of X-rays with high-Z nanomoities for use in cancer radiotherapy Sara N. Lim, Anil K. Pradhan,
X-Ray Production & Emission
Department of Radiation Oncology and BIO-X, School of Medicine Stanford University Molecular Imaging Program at Stanford MIPS Monte Carlo treatment planning.
1 Photon Interactions  When a photon beam enters matter, it undergoes an interaction at random and is removed from the beam.
Physics of Radiography
Derek Liu E. Poon, M. Bazalova, B. Reniers, M. Evans
Geant4 simulation of the attenuation properties of plastic shield for  - radionuclides employed in internal radiotherapy Domenico Lizio 1, Ernesto Amato.
Resident Physics Lectures Christensen, Chapter 6Filters George David Associate Professor Department of Radiology Medical College of Georgia.
Electron-impact inner shell ionization cross section measurements for heavy element impurities in fusion reactors Jingjun Zhu Institute of Nuclear Science.
X-Ray Medical Imaging Physics – IB Objectives
Sergey Ananko Saint-Petersburg State University Department of Physics
Radiation Interactions
A-LEVEL PHYSICS 15/09/ :49 Medical Physics.
HABIS X-RAY PRODUCTION AND EXPOSURE FACTORS X-RAY PRODUCTION AND EXPOSURE FACTORS PREPARED BY PREPARED BY Dr fahad albadr radiology chairman radiology.
Applications of Geant4 in Proton Radiotherapy at the University of Texas M.D. Anderson Cancer Center Jerimy C. Polf Assistant Professor Department of Radiation.
Resident Physics Lectures
Ian C. Smith 1 A portal-based system for quality assurance of radiotherapy treatment plans using Grid-enabled High Performance Computing clusters CR Baker.
Precision Analysis of Electron Energy Deposition in Detectors Simulated by Geant4 M. Bati č, S. Granato, G. Hoff, M.G. Pia, G. Weidenspointner 2012 NSS-MIC.
Monte Carlo Comparison of RPCs and Liquid Scintillator R. Ray 5/14/04  RPCs with 1-dimensional readout (generated by RR) and liquid scintillator with.
Characteristic Radiation in Tungsten Targets Shel l # of electrons Binding energy L Char M Char N Char O Char P Char Eff X-ray Energy.
IEEE NSS 2012 IEEE NSS 2007 Honolulu, HI Best Student Paper (A. Lechner) IEEE TNS April 2009 Same geometry, primary generator and energy deposition scoring.
1 Dosimetry part 1: X-ray interactions with matter G.Haddadi, PhD, MSc Associated prof. of Medical Physics Fassa University of Medical Sciences.
ENDF/B-VI Coupled Photon-Electron Data for Use in Radiation Shielding Applications by Dermott E. Cullen Lawrence Livermore National Laboratory & Robert.
Araki F. Ikegami T. and Ishidoya T.
Radiation Quality Chapter 4. X-ray Intensity Intensity: the amount of energy present per unit time per unit area perpendicular to the beam direction at.
Simulation of the energy response of  rays in CsI crystal arrays Thomas ZERGUERRAS EXL-R3B Collaboration Meeting, Orsay (France), 02/02/ /03/2006.
Historical Review and Modalities in Diagnostics
Evaluation of absorbed fractions for beta- gamma radionuclides in ellipsoidal volumes of soft tissue through Geant4 Ernesto Amato 1, Domenico Lizio 2 and.
RAD 354 Chapt. 8 X-ray emission
X-rays discovered in 1895 by Wilhem Roentgen Roentgenology – Branch of medicine dealing with x-ray or gamma rays in diagnosis and treatment. Radiology.
RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
Chapter 5 Interactions of Ionizing Radiation. Ionization The process by which a neutral atom acquires a positive or a negative charge Directly ionizing.
Determining Radiation Intensity
P. Rodrigues, A. Trindade, L.Peralta, J. Varela GEANT4 Medical Applications at LIP GEANT4 Workshop, September – 4 October LIP – Lisbon.
Date of download: 5/29/2016 Copyright © 2016 SPIE. All rights reserved. (a) Photograph of a single detector module. X-rays are incident from the top of.
한양대학교 원자력공학과 김 찬 형 제44회 춘계의학물리학회 & Geant4 Workshop (충무, 마리나 리조트, ) Monte Carlo 원리 및 응용.
Validation of GEANT4 versus EGSnrc Yann PERROT LPC, CNRS/IN2P3
Barium & Iodine Imaging Physics
MCS overview in radiation therapy
Interaction of Radiation with Matter
Chapter 9 Concepts you already know!!! INTENSITY = ROENTGENS AKA EXPOSURE l mAs and mR proportional? l kVp and mRproportional? l Distance and mRproportional?
A Study of Reverse MC and Space Charge Effect Simulation with Geant4
Chp 2 : Interaction of radiation with matter Radiation Contrast
Beam quality correction factors for linear accelerator with and without flattening filter Damian Czarnecki1,3, Philip von Voigts-Rhetz1, Björn Poppe3,
Chapter 5 Interactions of Ionizing Radiation
Ch 7. Quality of X-ray Beams
Resident Physics Lectures (year 1)
Very High Energy Electron for Radiotherapy Studies
X-RAY PRODUCTION AND EXPOSURE FACTORS
International Workshop on radiosensitization
Arghya Chattaraj, T. Palani Selvam, D. Datta
Resident Physics Lectures (Year 1)
X Rays Medical Physics Notes.
Resident Physics Lectures (year 1)
Resident Physics Lectures (Year 1)
Presentation transcript:

American Association of Physicists in Medicine (AAPM) Task Group on Monte Carlo Validation Sets: Geant4 Related Findings Ioannis Sechopoulos, Ph.D. Assistant Professor of Radiology and Imaging Sciences, Hematology and Medical Oncology Emory University Atlanta, USA

What is an AAPM TG? American Association of Physicists in Medicine (AAPM): –Scientific, educational and professional association of medical physicists –7,946 members –Publisher of Medical Physics journal, leading scientific journal on medical physics –Annual meeting is largest medical physics meeting 2

What is an AAPM TG? AAPM Task Groups are committees formed for a specific task –Final TG report has to be approved by TG and all parent committees (normally 2-3) –Report is published on AAPM website and summarized version in Medical Physics (after peer- review) –TG reports become “unofficial” standards in the medical physics community 3

Task Group Members Ioannis Sechopoulos, Emory University Steve Feng, Emory University Samir Abboud, FDA Andreu Badal, FDA Aldo Badano, FDA Iacovos Kyprianou, FDA Ehsan Samei, Duke University Elsayed Ali, Carleton University Ernesto Mainegra, National Research Council of Canada David Rogers, Carleton University Michael McNitt-Gray, UCLA Adam Turner, University of Arizona John Boone, UC Davis 4 Geant4 Penelope EGSnrc MCNP Sierra

Task Group Charge Define a set of Monte Carlo simulations relevant to diagnostic radiology Provide all needed information –Geometry –Source –Material composition –Energy spectra –Scoring –etc Provide results from a group of MC codes –Geant4, EGSnrc, MCNP, Penelope Investigators can use these “standardized” simulations as validation of their code 5

Simulations Developed Currently diagnostic x-ray imaging If successful, envision follow-up reports: –Nuclear medicine –Radiotherapy? 6

Simulations Developed Production of x-rays Half-value layers Radiography (including tomosynthesis): –Dose –X-ray scatter Mammography (including tomosynthesis): –Dose –X-ray scatter CT: –Dose in simple solids –Dose in voxelized phantom 7

Geant4 Simulations v9.5 patch 1 Except where noted: –G4EmLivermorePhysics –Cuts: 1.0 mm All elements are from NISTmanager 8

Good Results Good matches in results have been found in: –Half value layer –Radiography (dose and scatter) –Mammography (dose and scatter) For example… 9

Half-Value Layers (X-ray absorption in simple geometries) Mono-energetic and poly-energetic source of photons Aluminum absorber –Thickness set to achieve HVL and QVL Ideal, energy discriminating photon counter detector 10

Results Comparison Geant4 Summary:Primary OnlyTotal 30 keV HVL:0.500 QVL: keV HVL:0.499 QVL: kVp HVL:0.525 QVL: kVp HVL:0.504 QVL:0.253 Penelope Summary:Primary OnlyTotal 30 keV HVL:0.500 QVL: keV HVL:0.498 QVL: kVp HVL:0.539 QVL: kVp HVL:0.509 QVL:

Geant4 / Penelope Summary:Primary OnlyTotal 30 keV HVL:1.00 QVL: keV HVL:1.00 QVL: kVp HVL:1.03 QVL: kVp HVL:1.01 QVL: Geant4 and Penelope match well in simple simulations of photon absorption with simple geometries Results from other MC codes are coming.

Problems encountered in other simulations Simple and voxelized CT –Still investigating X-ray generation –Problems with: G4EmLivermorePhysics Splitting 13

Example of Mismatch Still Under Investigation: CT with Simple Volumes 14 Simulation of CT with simple CT phantom solid Dose at two small cylinders from rotating photon source Mono-energetic and poly-energetic photon source

Geant4 Results 15

Penelope / EGSnrc 16

Penelope / Geant4 (similar to EGSnrc / Geant4) 17 So there is some error there, but still not sure where. Under investigation.

Problems with G4: Production of X-rays 18 Mo or W 30 keV (Mo) or & 100 keV (W)

Production of X-Rays Mo Target, 30 keV electrons 19 Characteristic emissions after ionization Measurements with filter in place Semi-empirical model, only inherent filtration

Production of X-Rays Mo Target, 30 keV electrons 20

Production of X-Rays Mo Target, 30 keV electrons 21

Production of X-Rays W Target, 100 keV electrons 22

Production of X-Rays W Target, 100 keV electrons 23

Production of X-Rays W Target, 100 keV electrons 24

Production of X-Rays W Target, 100 keV electrons 25

Production of X-Rays So characteristic emission from electron interaction with materials seems too low. Tracking output showed that: –NO characteristic emission after ionization was taking place –The low peak is from characteristic emission after photoelectric effect from bremsstrahlung x-rays 26

Similar test with TestEm5 emLivermore 27

Similar test with TestEm5 emPenelope 28

Biased Bremsstrahlung with /process/em/setSecBiasing 29 e-e- N x-rays ph Weight = 1/N Photoelectric effect Characteristic emission ph Weight = 1

Biased Bremsstrahlung with /process/em/setSecBiasing Vladimir Ivantchenko provided a patch for this problem (April 2012). Patch works if applied to v9.5p1, but does not fix the issue if applied to v9.5. –This was also seen by another investigator. 30

Summary The task group is still working on obtaining all MC results and comparing them. –Hopefully I can present final results next year! ~Half of result comparisons up to now have shown good match 2 different cases need further investigation In 1 case (x-ray production) problems were identified with emLivermore –Daughter generation after atomic de-excitation is too low/non-existent –Splitting weights was inconsistent (patch fix ready for v9.5p1) –emPenelope gives correct results 31

Thank You Questions?