Improved Fire Protection – to retrofit fire sprinklers?

Slides:



Advertisements
Similar presentations
FHM TRAINING TOOLS This training presentation is part of FHMs commitment to creating and keeping safe workplaces. Be sure to check out all the training.
Advertisements

Fire-fighting & Rescue in Buildings with Engineered Solutions Roy Wilsher Director Community Protection & Chief Fire Officer.
RETROFITTING OF SPRINKLER SYSTEMS
ROTARY CLUB Of SARATOGA Rotary International - San Jose Water Company Thailand Water Project Roy Russell, Rotary International and Bill Tuttle, SJWC.
Part of the BRE Trust Protecting People, Property and the Planet What have fire doors ever done for us? Ian Stewart Certification scheme manager June 2014.
Fan Coil Unit Product Line-up. FCU Home Application Show.
AQ2511B0 Boiler Reset Panel – for Whole House Heating Control – Immediate Retrofit Opportunity !
Buildings and Structures 2 Fixed Installations Aim To provide students with information to allow them to recognise the types of fixed fire protection.
WelcomeWelcome BURT PROCESS EQUIPMENT “Harvesting The Rain” Rainwater Reclamation.
1 WATER SUPPLY DISTRIBUTION On completion of this module you should be able to Describe pipe structures, types and installation design gravity and rising.
BS9990 : 2015 Updates and/or Changes
WETSIDE DESIGN © Copyright 2008 HVAC Design Solutions1 Essential Design Programs with Accurate Sizing Calculations help to “Streamline Your Design” Essential.
Richard B. Garrett, PE March 2, Issues covered in this Presentation: Considerations for determining size of tank desired. Owner’s perspective of.
N.F.P.A. 13R Justin Bohlmann FIR-204.
Booster System Basics: Constant Speed Systems
Backflow Preventor. (4) The Contractor V may install the cross-connection backflow prevention device as defined in this chapter on new installations.
Department of Fire and Building Safety Code Review Official III Plan Reviewer Tony Bradshaw General filing questions:
SOLAR PHOTOVOLTAIC WATER PUMP
1402 Hybrid Firefighter I 6 th Edition Chapter 14 Water Supply.
Wellington County Septic Social!
1 Fire Service Professionals. 2 Overview n Industrial Fire Systems n Innovations n Hazardous Areas n Changes to regulations n System integration n Future.
Chapter 14: Inspection and Maintenance
Learning Objective 1 Explain the ways water supply system components are used by firefighters.
Fresno County Fire Protection District. Fire Sprinklers Systems Residential – 13D October 30, 2007.
Technical Review Needed Fire Flow Analysis Developer Services Summit November 16, 2010 Engineering - Asset Planning Joe Dugandzic, PE.
Product Evaluation ACT Objective O Emphasize the importance of proper product evaluation and selection O Develop insight into effective procedures,
1 CTC 450 Review Water Quality Water Quality. 2 CTC 450 Water Distribution Systems Water Distribution Systems.
Infrastructure Vulnerability Profile. Are you considering hazard and climate risks in your infrastructure planning, siting, and improvement decisions?
ISO OPERATIONAL CONTROL
Model LS-2001 Lift Station Controller Model LS-2001 Lift Station Controller Copyright, 2006 © U-Tap Controls Click on slide to move through presentation.
November 2008 Eureka Facilities Meeting. Introduction.
FIRE PROTECTION TOPICS OF INTEREST Defense Nuclear Facilities Safety Board.
Experts in Chem-Feed and Water Treatment Pre-Engineered Systems 1.
Decision making process / basic options assessment Mercury Storage and Disposal LAC Two Countries Project Gustavo Solórzano Ochoa, Consultan t Montevideo,
Installer Training and Apprenticeships 1 James D. Lake Vice President of Training & Communications NFSA.
CENF target facility civil engineering specifications – summary M. Calviani (EN/STI) for the CENF-SBWG team Neutrino Platform Meeting 30 th October 2014.
The Future of Sludge Disposal: A Fresh Perspective after Sandy Jim Meehan – Executive Director Rahway Valley Sewerage Authority.
Forum on Catastrophe Preparedness: Partnering to Protecting Workplaces.
Solar Water Heating by Solar Texas.
Firefighter III Module B Overhaul (4-16) Identify five indicators of structural instability. (4-16.2) Indicators of structural instability. 
Lift Typical Building Floor Plan. Complete with fire walls. Click on and we will add Some of the different Passive and Active systems that you could come.
March 2015 ALLEN INDEPENDENT SCHOOL DISTRICT School Board Meeting March 2015 Construction Update for the Service Center.
Shelter Training 08b – Belgium, 16 th –18 th November, 2008 based on content developed by p This session introduces the six transitional settlement options.
The Wildlife Estates Initiative Public Policy. The Message Appropriate land-management & Sustainable hunting: – Regulates and enhances natural resources;
MBIE Fire Programme 2015/16 Michael Belsham – Fire Engineer.
THE IMPORTANCE OF SANITARY SURVEYS by Mary L. Howell, Backflow Management Inc.
Plumbing Building Developing Policies and Guidelines Sydney Water Customer Contract Connections to Sydney Water Systems Policy Responsibilities of Connected.
FOR APRIL 2013 THE REHABILITATION AND EXPANSION OF CENTRAL OGBIA WATER PROJECT,AT BAYELSA STATE SITE REPORT FOR NOVEMBER 2013.
IFSA Copenhagen conference june Speaker René Therkelsen Head of department Bravida Danmark A/S - Sprinklerengineer Chairman Sikkerhedsbranchens.
Retrofitting and Maintenance. Regular Maintenance is Necessary Failure to Perform Maintenance Leads to….. Diminished Performance Deterioration Failure.
Subpart F - Fire Protection & Prevention ( ) Flammables/combustibles - Approved containers Fire protection program/equipment 2A fire extinguishers.
15 Water Supply. 15 Objectives (1 of 2) Discuss rural water supplies. Describe how portable tanks are used to supply water for firefighting. Describe.
Construction Management At Risk Process
Your Septic System Designing and its Maintenance.
The Next Generation of a Gamma Irradiation Facility GIF++
ODS & SGG Considerations for Changing a System
Effluent from a septic tank effluent gravity (STEG) or septic tank effluent pump (STEP) system is discharged into a collection system. A typical STEP/STEG.
Backflow Prevention and Cross Connection Control Update
Self-expanding foam system
Introduction to pipe sizing for high rise buildings
Private Fire Hydrant. Fire hydrant systems (also known as fire pumps, hydrant boosters, fire water pumps) are high pressure water pumps designed to increase.
Choropleth maps Used to demonstrate trends in data.
Maintenance Apart from safety, maintenance is needed to keep plant in an acceptable condition. Maintenance of this kind must be reviewed on an economic.
Backflow Survey Glen Burr.
Shelter and settlement options
Ocean Sands Condo Association Annual Meeting January 19, 2019
OVN Trading Engineers OVN Is one of the leading company in industry providing generators, service, rental, repair, water pumps, security.
Prevalent Dialysis and Transplants Australia (at 31st December) Number of Patients
Presentation transcript:

Improved Fire Protection – to retrofit fire sprinklers?

Current Status Victoria mandatory fire sprinkler protection Queensland mandatory to upgrade fire protection sprinklers are one option New South Wales retrofitting is common across many types of buildings legislative changes unknown Class 9C currently require sprinklers – AS

How do you go about installing sprinklers? Brief Considerations/Investigations Budget Procurement

Brief Thorough site inspection Size of facility, floor areas and plans Form of construction Water pressure availability Concealed or exposed systems (surface mounted) Heritage considerations Hazardous materials Location of booster pump sets and tanks

Considerations/Investigations Which Australian Standard do you use – AS or AS Fire indicator panel – Can it be extended – Check for compatibility and capacity – Check ongoing maintenance cost How will the whole installation look?

Types of sprinkler heads

Budget Establish a typical cost of installation for your facility. Considerations of variations to typical include : – Type of sprinkler head – Water Pressure enquiry will you need pumps &/or tanks – Design – Additional building work due to installation – Rural locations – Staging/business disruption – Ongoing maintenance

The next step Engage an impartial expert to work with you on planning the installation and whole of life cost Generic systems are usually more appropriate for building owners than proprietary systems

Thank you Alexandra Davis Ph: