1 Author: R. Chiodi 03/21/1997 rev 04/16/2000 Confined Space Entry Environmetal Safety & Health - Safety Center.

Slides:



Advertisements
Similar presentations
60% of deaths come about when someone tries to rescue someone else!
Advertisements

1 R. Chiodi 03/25/1997 rev 04/16/2001 Safe Work Permits.
MDPI/GOODWILL OIL AND GAS TRAINING
Module 9 Confined Space.
CONFINED SPACE ENTRY.
FHM TRAINING TOOLS This training presentation is part of FHM’s commitment to creating and keeping safe workplaces. Be sure to check out all the training.
Slide 1 (of 31) Confined Space Training Permit-Required Confined Spaces.
1/05 School Safety Training Permit-Required Confined Spaces WAC Part M.
Confined Space Entry OSHA Standard
Confined Spaces “Non-Permit” “Permit-Required”.
Permit Required Confined Space Entry Standard 29 CFR Part Presented by: Winton-Ireland, Strom & Green Insurance Agency Inc.
H2S H2S Awareness Introduction
29 CFR CONFINED SPACE ENTRY.
29 CFR CONFINED SPACE ENTRY.
Confined Spaces – Part 2 An Overview of the WISHA Confined Spaces Standard.
PERMIT REQUIRED CONFINED SPACES PERMIT REQUIRED CONFINED SPACES.
Confined or Enclosed Spaces [29 CFR (6)(i & ii)
ENTRANT, ATTENDANT & QUALIFIED PERSON TRAINING. COURSE OVERVIEW Introduction and Purpose Defining a Confined Space Locations and Types of Confined Spaces.
Personal Protective Equipment
Safe Chemical Handling
CONFINED SPACE AWARENESS. DEFINITION OF CONFINED SPACE Is large enough and so configured that an employee can bodily enter and perform assigned work Has.
1 BUILDING TRADE SAFETY CONFINED SPACES. 2 BUILDING TRADE SAFETY Confined spaces.
Confined Space Safety Training Presentations
CONFINED SPACE ENTRY 29 CFR
29 CFR CONFINED SPACE ENTRY.
HVACR416 - Design Confined Spaces. Confined Space Entry Definitions: The entrant is the person who enters a confined space. The attendant is the person.
Risk Management Services Confined Space Entry Basics.
ASSURANCE Hazards of Confined Spaces. ASSURANCE You Can’t Afford to Make a Mistake Every year people die in confined spaces. It doesn’t have to happen.
Copyright  Business & Legal Reports, Inc. BLR’s Safety Training Presentations Permit-Required Confined Spaces 29 CFR
Copyright  Progressive Business Publications Permit-Required Confined Space Safety Subpart J.
1a.  A confined space is:  Large enough to enter and perform work  Limited in the way of entry or exit  Not designed for continuous occupancy 1a.
Permit-Required Confined Spaces 29 CFR Why Comply???? Confined space entry is a leading cause of occupational fatalities in this country.
CONFINED SPACE We are going to start this class with a small quiz. The purpose of the quiz is to allow you to determine where you are and what you know.
Your Challenge 1)Use the SCORE CARD provided as a guide to the presentation. 2)Make an honest evaluation of your understanding of the topics discussed.
Copyright  Progressive Business Publications Hazard Communication.
CONFINED SPACE ENTRY. CONFINED SPACE STATISTICS u 65% Of All Confined Space Fatalities Due To Hazardous Atmosphere u In All Deaths Last Year (139), There.
Tyson Burt Mathieu Gagnon
Confined Space Entry Training OSHA 29 CFR
CONFINED SPACE RESCUE Over 60% of deaths in Confined Space work are Rescuers. Causes: l Lack of Training l Improper Equipment l No Communications l No.
Confined Spaces in Construction
Hazard Communication Graphic
TRENCHING & EXCAVATION
What is a safe work permit? A safe work permit is a written record that authorizes specific work, at a specific work location, for a specific.
Confined Spaces. Definition: Are large enough that an employee can bodily enter them Are not designed for continuous occupancy. Have limited or restricted.
Confined Spaces – Part 2 An Overview of the Confined Spaces Issues.
Revised Spring 2007 Hazard Communication And Your Right - To - Know Dept of Environmental Safety Services.
Confined Space Rescue Level I Technical References: Mod 3.
1 Welcome to CONFINED SPACE ENTRY. 2 INSTRUCTORS Brian Hitt.
Copyright  Business & Legal Reports, Inc. BLR’s Safety Training Presentations Permit-Required Confined Spaces 29 CFR
Confined Space Hazards. What is a Confined Space? A confined space is a space that: –Is large enough and so configured that a person can bodily enter.
Confined Spaces - General. Confined Space-General + Many, or perhaps even most, workplaces have something on the premises that would be correctly termed.
Excavation & Trenching Awareness Plus
29 CFR Subpart G.  General Industry Is large enough and so configured that an employee can bodily enter and perform assigned work Has limited.
Workplace Safety 3220 Chapter Confined Space Entry.
Trench Hazards Introduce the module. Trenching & Excavations Continuing Education Third Quarter 2017 Session 3.
CONFINED SPACE ENTRY TRAINING PROGRAM
Confined Space (Permit-required) Rescue/ Emergency Services
Confined Space.
WISHA Confined Spaces Standard
Confined/Enclosed Spaces Continuing Education Fourth Quarter 2017
29 CFR CONFINED SPACE ENTRY.
Confined Space (Permit-required)
29 CFR CONFINED SPACE ENTRY.
CONFINED SPACE ENTRY TRAINING
CONFINE SPACE.
Confined space.
29 CFR CONFINED SPACE ENTRY.
Confined Space Hazards & Controls
Presentation transcript:

1 Author: R. Chiodi 03/21/1997 rev 04/16/2000 Confined Space Entry Environmetal Safety & Health - Safety Center

2 Author: R. Chiodi 03/21/1997 rev 04/16/2000 Confined Space Entry Why are we here? OSHA and this company require that all employees who must enter into confined spaces receive training as to the hazards, procedures and equipment required to do so safely.

3 Author: R. Chiodi 03/21/1997 rev 04/16/2000 Confined Space Entry Definitions: The entrant is the person who enters a confined space. The attendant is the person who stays with the entrant outside the confined space, and is responsible for assisting the entrant in exiting the confined space, and calling for emergency assistance when required. The safety representative is the qualified person who evaluates the hazards, prescribes required equipment and precautions and issues the Confined Space Entry Permit.

4 Author: R. Chiodi 03/21/1997 rev 04/16/2000 Confined Space Entry Goals and Objectives: At the end of this session you will: obe familiar with the hazards and requirements of “safe” confined space entry. opass a 10 question quiz with a score of 100%.

5 Author: R. Chiodi 03/21/1997 rev 04/16/2000 Confined Space Entry - Hazards Both animal and plant life require oxygen to live. One of the primary hazards of entering confined spaces is oxygen deficiency. When oxygen is present in concentrations less than 19.5% the atmosphere is said to be oxygen deficient. O2O2 O2O2

6 Author: R. Chiodi 03/21/1997 rev 04/16/2000 Confined Space Entry - Hazards Oxygen can also be present in concentrations that are too high. Oxygen in concentrations greater than 23% is too oxygen rich and can cause combustible materials to ignite very quickly.

7 Author: R. Chiodi 03/21/1997 rev 04/16/2000 Confined Space Entry - Hazards Oxygen deficiency can be caused by several processes: Consumption: oxygen is used up by the person who is in the confined space and turned into carbon dioxide. Displacement:denser materials push the oxygen out of the occupied space. Reaction:oxygen is reacted with other materials to make other compounds.

8 Author: R. Chiodi 03/21/1997 rev 04/16/2000 Confined Space Entry - Hazards The human body requires oxygen to carry out cellular metabolism. Oxygen is brought in through the lungs and transported to cells of body organs by the red blood cells. When blood is rich in oxygen it turns red. O2O2 CO 2 After oxygen is delivered to body organs and used by organ cells, it reacts with carbon to make carbon dioxide. Red blood cells carrying carbon dioxide turn blue. Carbon dioxide is carried back to the lungs by the red blood cells and exhaled into the surrounding atmosphere.

9 Author: R. Chiodi 03/21/1997 rev 04/16/2000 Confined Space Entry - Hazards CO 2 O2O2 Given a fixed amount of oxygen as you would have in a confined space, respiration of oxygen causes carbon dioxide to increase. When oxygen decreases to less than 19.5%. the atmosphere is said to be oxygen deficient, putting occupants of the confined space at risk of losing consciousness and death.

10 Author: R. Chiodi 03/21/1997 rev 04/16/2000 Confined Space Entry - Hazards Processes which operate by the principle of combustion use up oxygen much faster than the human respiration. Products of combustion vary with the fuel that is present and the temperature of the combustion reaction. Welding, burning natural gas, propane, gasoline, and diesel engines are examples of combustion processes. CO 2 H20H20 NOx CO O2 fuel

11 Author: R. Chiodi 03/21/1997 rev 04/16/2000 Confined Space Entry - Hazards Manholes often remain covered for long periods of time. Naturally occurring toxins, such as hydrogen sulfide can accumulate inside of manholes. H2SH2S Manholes may also accumulate highly flammable gasses such as methane and ethane. Unlike the gas we receive at home, we cannot detect some of these gases with our sense of smell. CH 4

12 Author: R. Chiodi 03/21/1997 rev 04/16/2000 Confined Space Entry - Hazards Toxic and flammable materials are sometimes illegally put into sanitary and storm sewers. Leaking tanks or spills may migrate under ground causing seepage into manholes. ?? Material can leach through soil from many miles away. ??

13 Author: R. Chiodi 03/21/1997 rev 04/16/2000 Confined Space Entry - Hazards Sudden releases of fluid solids, such as granulated salt, sugar, or sand, liquids, and dense gases can cause engulfment of persons inside underground tanks, or pits. When torrential forces are suddenly released, people may be struck by moving objects, or be pushed helplessly downstream.

14 Author: R. Chiodi 03/21/1997 rev 04/16/2000 Confined Space Entry - Hazards Trenches, ravines and other excavations may also be considered confined spaces, if there is a potential for accumulation of toxic gases, engulfment and/or the depletion of oxygen. ?

15 Author: R. Chiodi 03/21/1997 rev 04/16/2000 Confined Space Entry - Hazards Many confined space entries involve a complex set of exposures to mechanical, electrical, pressure and chemical hazards.

16 Author: R. Chiodi 03/21/1997 rev 04/16/2000 Confined Space Entry The entry of a confined space begins with a Confined Space Entry Permit. Confined Space Entry Permit Location and Description of Confined Space: Reason for Entry: Permit Issued to (Name of Company/Organization): Confined Space Entry Permit Location and Description of Confined Space: Reason for Entry: Permit Issued to (Name of Company/Organization): The permit system requires that a qualified safety representative visit the work location and evaluate the conditions under which entry will be made.

17 Author: R. Chiodi 03/21/1997 rev 04/16/2000 Confined Space Entry Each process hazard to which the entrant may be exposed, adjacent operations or processes, and scheduled activity are reviewed. For each hazard identified, countermeasures are detailed on the Confined Space Entry Permit.

18 Author: R. Chiodi 03/21/1997 rev 04/16/2000 Confined Space Entry The safety representative tests the space for hazardous concentrations of known harmful substances, such as hydrogen sulfide, carbon monoxide, and flammable liquid or gas. The concentration of oxygen is measured at the same time.

19 Author: R. Chiodi 03/21/1997 rev 04/16/2000 Confined Space Entry - Hazards If concentrations of materials are found to be at harmful levels, the confined space must be ventilated to remove them before entry. ?? Fresh Air Fresh outside air is blown into the space to dilute and remove contaminants, and supply oxygen. Fresh outside air is blown into the space to dilute and remove contaminants, and supply oxygen. O2O2 O2O2 O2O2 O2O2

20 Author: R. Chiodi 03/21/1997 rev 04/16/2000 Confined Space Entry - Hazards Should the concentration of contaminants remain at harmful levels, respirators may have to be worn to assure a safe air supply. Should the concentration of contaminants remain at harmful levels, respirators may have to be worn to assure a safe air supply. ?? Fresh Air O2O2 O2O2 O2O2 O2O2 ??

21 Author: R. Chiodi 03/21/1997 rev 04/16/2000 Confined Space Entry Means of emergency rescue must be readily available to the confined space entry attendant for emergency extrication of entrants.

22 Author: R. Chiodi 03/21/1997 rev 04/16/2000 Confined Space Entry A means must be provided for both safe normal entry or exit, and emergency extrication. Tripods with hoist, lifeline, and full body harness are often used for emergency extrication. Ladders may be used for ordinary entry and exit.

23 Author: R. Chiodi 03/21/1997 rev 04/16/2000 Confined Space Entry Barriers to prevent passers-by and the curious from falling into the opening must be put in place. Holes and openings must be closed or guarded when not attended.

24 Author: R. Chiodi 03/21/1997 rev 04/16/2000 Confined Space Entry Place warning signs where pedestrians can see them. Signs must state the hazard and the required action. CAUTION Opening in Ground Keep Out !

25 Author: R. Chiodi 03/21/1997 rev 04/16/2000 Confined Space Entry Confined Space Entry Permit Requirements Eye protectionyesno Respiratory protectionyesno Continuous Ventilationyesno Body Protectionyesno Hand Protectionyesno Foot Protectionyesno Weather Protectionyesno Confined Space Entry Permit Requirements Eye protectionyesno Respiratory protectionyesno Continuous Ventilationyesno Body Protectionyesno Hand Protectionyesno Foot Protectionyesno Weather Protectionyesno Required countermeasures include personal protective equipment for hazards expected to be found within the confined space. Eye and head injuries are always a potential, therefore safety glasses and hard hats are required wear for entrants. Other conditions may require the use of respirators, safety shoes, protective gloves, and other personal protective equipment.

26 Author: R. Chiodi 03/21/1997 rev 04/16/2000 o Danger Do not use! o Danger Do not use! Confined Space Entry Confined Space Entry Permit Requirements Ground Fault Interruptionyesno Lockout of Hazardous Energy Sourcesyesno Confined Space Entry Permit Requirements Ground Fault Interruptionyesno Lockout of Hazardous Energy Sourcesyesno Required countermeasures also include prevention of electrical shock hazards due to loss of earth ground for portable tools. GFCI’s are required for portable electric tooling. There may also be a need to lockout and tag equipment both in the confined space and on adjacent equipment and processes.

27 Author: R. Chiodi 03/21/1997 rev 04/16/2000 Confined Space Entry H2SH2S HCN Entrants must leave the confined space when the monitor alarm is activated. It is the attendant’s responsibility to see that the entrant leaves the space during an alarm. Entrants must leave the confined space when the monitor alarm is activated. It is the attendant’s responsibility to see that the entrant leaves the space during an alarm. CH 4 CO CO 2 O2O2 Entrants must constantly monitor the confined space for toxic gases, oxygen, and combustible gases. Entrants will be issued a personal monitor to wear for this purpose.

28 Author: R. Chiodi 03/21/1997 rev 04/16/2000 Confined Space Entry Should conditions develop which require extrication, and the entrant cannot get out of the confined space on their own, the attendant must call for emergency assistance at once! Should conditions develop which require extrication, and the entrant cannot get out of the confined space on their own, the attendant must call for emergency assistance at once!

29 Author: R. Chiodi 03/21/1997 rev 04/16/2000 Confined Space Entry The attendant should attempt to remove the entrant from the confined space using tripods, hoist, and lifelines. Attendants are NOT TO ENTER CONFINED SPACES. Lethal hazards may be present within the confined space. Only properly equipped and trained emergency rescue personnel may enter confined spaces to make rescues. The attendant should attempt to remove the entrant from the confined space using tripods, hoist, and lifelines. Attendants are NOT TO ENTER CONFINED SPACES. Lethal hazards may be present within the confined space. Only properly equipped and trained emergency rescue personnel may enter confined spaces to make rescues.

30 Author: R. Chiodi 03/21/1997 rev 04/16/2000 Confined Space Entry - Summary Confined space entry hazards can include: - the presence of toxic substances - insufficient oxygen, or too much oxygen - engulfment - presence of combustible gases and liquids - process or equipment related hazards. - conditions changing from nonhazardous to hazardous.

31 Author: R. Chiodi 03/21/1997 rev 04/16/2000 Confined Space Entry - Summary Confined Space Entry Permit Location and description of confined space: Reason for entry: Permit issued to: Supervisor’s Name: Attendant’s name: Permit issuer’s name: % oxygen:% lower explosive limit: ppm CO: H 2 S: Requirements Emergency Rescueryesno Continuous Gas Monitoryesno Barrier for ground openingsyesno Warning Signsyesno Safety Harness with life lineyesno Tripod / Hoist / Pulleyyesno Access (ladders/other)yesno Eye protectionyesno Respiratory protectionyesno Continuous Ventilationyesno Body Protectionyesno Hand Protectionyesno Foot Protectionyesno Weather Protectionyesno Ground Fault Circuit Interruptersyesno Lockout of Hazardous Energyyesno Confined Space Entry Permit Location and description of confined space: Reason for entry: Permit issued to: Supervisor’s Name: Attendant’s name: Permit issuer’s name: % oxygen:% lower explosive limit: ppm CO: H 2 S: Requirements Emergency Rescueryesno Continuous Gas Monitoryesno Barrier for ground openingsyesno Warning Signsyesno Safety Harness with life lineyesno Tripod / Hoist / Pulleyyesno Access (ladders/other)yesno Eye protectionyesno Respiratory protectionyesno Continuous Ventilationyesno Body Protectionyesno Hand Protectionyesno Foot Protectionyesno Weather Protectionyesno Ground Fault Circuit Interruptersyesno Lockout of Hazardous Energyyesno Required countermeasures are determined by a qualified safety professional. Once the required countermeasures are in place, a permit is issued by the safety representative and the confined space may be safely entered. Should an emergency arise during the entry, the attendant notifies an emergency response team and attempts to extricate the entrant.

32 Author: R. Chiodi 03/21/1997 rev 04/16/2000 Confined Space Entry -Summary Confined Space Safe Work Permit Required CAUTION Confined spaces are required to be labeled. Some spaces may have been overlooked. Contact your safety representative when in doubt. It is up to you to obey signs and to follow permit procedures before entry.

33 Author: R. Chiodi 03/21/1997 rev 04/16/2000 Where to Get Help? The supervisor of a confined space entry should be contacted for any equipment necessary to complete the task at hand. Safety Representatives are responsible for answering questions about the confined space entry permit, countermeasures, sampling methods, and instrumentation.

34 Author: R. Chiodi 03/21/1997 rev 04/16/2000 References and Sources for More Information OSHA 29CFR Permit - Required Confined Spaces

35 Author: R. Chiodi 03/21/1997 rev 04/16/2000 Confined Space Entry