Chapter 9 System Sizing Sizing Methodologies • Sizing Utility-Interactive Systems • Sizing Stand-Alone Systems • Sizing Multimode Systems • Sizing Hybrid.

Slides:



Advertisements
Similar presentations
PhotoVoltaic System Sizing © ARJ This is not a How-To presentation. It is a What and Why presentation.
Advertisements

PowerPoint ® Presentation Chapter 4 System Components and Configurations Components Electricity Sources System Configurations.
PV Market Trends and Technical Details. All of US has Suitable Solar Resource for Large Scale PV Deployment.
Supercapacitor Energy Storage System for PV Power Generation
ELECTRICAL SYSTEMS 21.3.
CBA FINAL PROJECT 2002 Gyorgyi Cicas ; Jose L. Aguirre; Po-Hsin Lin CBA OF OPERATING PHOTOVOLTAIC SYSTEM IN PITTSBURGH.
Charge Controllers Charge Controller Features Charge Controller Types
Lesson 25: Solar Panels and Economics of Solar Power
Bryan Underwood Advisor: Prof. Gutschlag Alternating Current Power Factor Monitoring and Correction.
THE PROCESS OF DESIGNING A PV SYSTEM
Chapter 7 Charge Controllers
Engineering Photovoltaic Systems I Part I Original Presentation by J. M. Pearce, 2006
Chapter 8 Inverters AC Power • Inverters • Power Conditioning Units • Inverter Features and Specifications.
Photovoltaic Solar Cells and Solar Energy Systems for Home Usages Mohammad Anisuzzaman.
UDC ZERO ENERGY VISTOR CENTER. System Components Solar Array –Primary Power Generator –Array consists of 12 BP SX3190B Solar Modules.
PowerPoint ® Presentation Chapter 12 Utility Interconnection Distributed Generation Generators Inverters Interconnection Codes and Standards Interconnection.
Chapter 6 Batteries Battery Principles • Battery Types • Battery Systems • Battery Installation.
Electricity Compare AC and DC electrical current and understand their important differences Explain the relationship between volts, amps, amp-hour, watts,
Solar Power EDSGN 100 Sec. 13 Design Team 1 Kyle Feaster Alex Shivetts Kait Levin.
Solar Lightings Solar Module. Charge Controller. Battery. Inverter. Loads Accessories.
Switching Power Supply Component Selection 7.2b Inductor Selection – Application.
Renewable Energy as Priority
Sustainable Energy Systems Engineering Peter Gevorkian Ch 2: Solar Power Generation Design Brevard Community College EST1830 Bruce Hesher.
Power Generation from Renewable Energy Sources Fall 2013 Instructor: Xiaodong Chu : Office Tel.:
Solar Powered Charging Station: Mid-Term Presentation Design Team: Ben Hemp Jahmai Turner Rob Wolf, PE Sponsors: Conn Center for Renewable Energy Dr. James.
Manufacturing Engineering Solar Panel Energy System Copyright © Texas Education Agency, All rights reserved. 1.
Hybrid Wind & Solar Generation Project
Batteries Storing Renewable Energy “Chemical engines used to push electrons around”
Designing Solar PV Systems (Rooftops ). Module 1 : Solar Technology Basics Module 2: Solar Photo Voltaic Module Technologies Module 3: Designing Solar.
Power Conditioners and Uninterruptible Power Supplies
PV System Components Advanced Engineering The Technology Landstown High School.
PV off Grid Design Eng. Laith Basha
S.A.A 06/071 LECTURE 4 PHOTOVOLTAIC SYSTEM. S.A.A 06/072 Introduction.. 3 common configuration of PV systems: –Grid-connected PV system –Stand-alone PV.
Power Generation from Renewable Energy Sources Fall 2013 Instructor: Xiaodong Chu : Office Tel.:
Renewable Power Generation Solar Photovoltaic (PV) Wind Energy Hydropower Solar Thermal Electric Geothermal.
Serial vs. Parallel Connections. Serial Connections Serial connections are positive-to-negative in a chain.
Hybrid Solar Systems Michael Lien Renergy Jan. 5, 2011.
Solar Energy Technology Science Summer Camp Session 9: Fri 9:00 AM - 12:00 N : Field trip to Energy Masters and Installing/Commissioning the System.
System Sizing Sizing methodologies Sizing calculations.
UNIVERSITY OF SISTAN AND BALUCHESTAN A Novel Techno-Economical Optimization Approach Based on Linear Integer Programing (LIP) for Hybrid Renewable systems.
Solar Powered Charging Station: Mid-Term Presentation Design Team: Ben Hemp Jahmai Turner Rob Wolf, PE Sponsors: Conn Center for Renewable Energy Dr. James.
Off Grid Living Without a Generator Solar Powered AC Coupled Micro Grid © Boyd Solar corp. Didsbury, AB
We hear much about energy problems; supply shortages, pollution issues and high prices, but the solutions to these problems are here now in the form of.
USAFA Department of Astronautics I n t e g r i t y - S e r v i c e - E x c e l l e n c e Astro 331 EPS—Design Lesson 20 Spring 2005.
Noor Shazliana Aizee bt Abidin
Battery Backup PV Systems Design Considerations
PV System Design and Installation LO 10 Performance Analysis and Troubleshooting.
Figure 3-9: Implementing the Load Diverter CAUTION Do NOT connect the wires to the Diversion Load Controller or the terminal block at this point. IF.
درس تبدیل مستقیم انرژی I L : Light current I D : Diode current I SH : Shunt current k: Boltzmann constant N S : number of cells in series.
1\ Backup system for solar on-grid installation 1 1pcs XTM inverter charger, nominal power 3.5KVA, 30min. Power 4KVA AC DC Load2 (secured power)
Solar Powered Charging Station: Mid-Term Presentation Design Team: Ben Hemp Jahmai Turner Rob Wolf, PE Sponsors: Conn Center for Renewable Energy Dr. James.
IEA INTERNATIONAL ENERGY AGENCY PHOTOVOLTAIC POWER SYSTEMS PROGRAMME Overview 1.Introduction / Summary 2.PV-diesel hybrid systems 3.Measurement equipment.
Renewable Energy Systems David Buchla | Thomas Kissell | Thomas Floyd Copyright © 2015 by Pearson Education, Inc. All Rights Reserved Buchla, Kissell,
Basic Electronics for Computer Engineering 1 Chapter 3 Ohm’s Law.
Assessment and Design of Rooftop Solar PV system
Photovoltaic and Battery Primer
Electrical Systems Series Circuits Parallel Circuits Electrical Power.
Example of PV System Design
Photovoltaic Systems Engineering Session 15 Stand-Alone PV Systems
Photovoltaic Systems Engineering Session 16 Stand-Alone PV Systems
Photovoltaic cell energy output:
OPERATION CONTROL STRATEGY AND SIMULATION OF PV SYSTEM
Sizing Methodologies • Sizing Calculations
RED Which circuit above is a parallel circuit? Draw!
Photovoltaic Systems Engineering Session 16 Solar+Storage Systems
—Two power conditioning units (PCU)’s needed only if batteries are added for grid failure —AC output is consistent with the requirements of most loads.
Presentation transcript:

Chapter 9 System Sizing Sizing Methodologies • Sizing Utility-Interactive Systems • Sizing Stand-Alone Systems • Sizing Multimode Systems • Sizing Hybrid Systems • Sizing Calculations • Load Analysis • Critical Design Analysis • DC-System Voltage • System Availability • Battery-Bank Sizing • Array Sizing

Sizing strategy for stand-alone systems starts at the load side and proceeds backward to the array. When describing PV systems, it is logical to follow the energy flow from the array side to the loads. However, when sizing a PV system, it is necessary to consider the energy demand before considering the supply. Therefore, PV-system sizing, particularly for stand-alone systems, starts at the load side and proceeds backward to the array. See Figure 9-1. The objective is to first determine the requirements of the system loads and then to determine the size of the inverter, battery bank, and array that are needed to meet the requirements.

Sizing interactive systems begins with calculating the peak array DC power output, which is then derated for various losses and inefficiencies in the system to arrive at a final AC power output. Sizing interactive systems begins with the specifications of a PV module chosen for the system. Module ratings at STC are used to calculate the total expected array DC power output. This is then derated for various losses and inefficiencies in the system. The result is a final AC power output that is substantially lower but realistically accounts for expected real-world conditions. See Figure 9-2. To determine the expected energy production per day, the final AC power output is multiplied by the average daily insolation (peak sun hours) for the month or year on the array plane. For example, if the AC power output is estimated to be 2140 W and the average annual insolation is 5.1 peak sun hours (kWh/m²/day), then the average energy production is expected to be 10.9 kWh/day. The energy output can be additionally derated for shading, soiling, or downtime.

Interactive-system sizing is very flexible because the utility can supply extra energy to the system loads and receive excess energy from the PV system. The size of an interactive system is primarily limited by the space available for an array and the owner’s budget. However, financial incentive requirements, net metering limits, and existing electrical infrastructure may also influence system size decisions. Even if short-term periods of high insolation or low demand result in excess electricity, it is not wasted because it can be sold back to the utility for credit against subsequent utility bills. See Figure 9-3.

Stand-alone systems must be carefully matched to load requirements to avoid reducing load availability or producing more energy than is needed. Stand-alone PV systems are designed to power specific on-site loads, so the size of these systems is directly proportional to the load requirements. If the system is too small, there will be losses in load availability and system reliability. See Figure 9-4. If the system is too large, excess energy will be unutilized and wasted. Therefore, sizing of stand-alone systems requires a fine balance between energy supply and demand.

A load analysis tabulates the various kinds of loads and their power and electrical-energy requirements. A detailed load analysis completed during the site survey lists each load, its power demand, and daily energy consumption. See Figure 9-5. If load profiles are not nearly identical throughout the year, a load analysis should be conducted for each month. Similar loads can be grouped into categories, such as lighting fixtures with the same power requirements. DC loads, if any, should be listed separately from AC loads. This is because energy for AC loads goes through the inverter, resulting in losses that must be accounted for separately.

Load power and energy requirements can be easily measured with inexpensive meters. Peak-power information is usually found on appliance nameplates or in manufacturer’s literature. When this information is not available, peak power demand can be estimated by multiplying the maximum current by the operating voltage, though this is less accurate for reactive loads. Measurements, meter readings, or electric bills may also be used to help establish existing load requirements. See Figure 9-6.

Load requirements include the power demand and electrical-energy consumption for all the expected loads in the system. Electrical energy consumption is based on the power demand over time. Loads rarely operate continuously, so each load’s operating time must be determined. See Figure 9-7. This is the total number of hours per day on average that the load is operating.

The total DC-energy requirement is determined from the requirements for the DC loads (if any) plus the requirements for the AC loads, taking inverter efficiency into account. Inverters are not 100% efficient. Some power is lost in the process of converting DC energy to AC energy. Therefore, more DC energy is required to produce a certain amount of AC energy. Both the AC and DC energy requirements from the load analysis are used to determine how much total DC energy will be required. See Figure 9-8.

A critical design analysis compares the load requirements and insolation for each month to determine the critical design month. A stand-alone system must produce enough electricity to meet load requirements during any month. Therefore, systems are sized for the worst-case scenario of high load and low insolation. A critical design analysis compares these two factors throughout a year, and the data for the worst case is used to size the array. See Figure 9-9. The critical design ratio is the ratio of electrical energy demand to average insolation during a period. The load data comes from the load analysis, which is usually performed for each month. The insolation data is available from the solar radiation data sets. See Appendix. The ratio is calculated for each month.

DC-system voltage is chosen in proportion with the array size and to keep the operating current below 100 A. The selection of the battery-bank voltage affects system currents. See Figure 9-10. For example, a 1200 W system operating at 12 V draws 100 A (1200 W ÷ 12 V = 100 A). The same 1200 W system draws only 50 A at 24 V, or 25 A at 48 V. Lower current reduces the required sizes of conductors, overcurrent protection devices, disconnects, charge controllers, and other equipment. Also, since voltage drop and power losses are smaller at lower currents, higher-voltage systems are generally more efficient. Higher-voltage systems also require fewer PV source circuits in the array design.

System autonomy is approximated from the local peak sun hours and desired system availability. System availability is determined by insolation and autonomy. Accurate estimates of system availability require software to evaluate energy flow in the system on an hour-by-hour basis, but rough estimates are adequate for most PV applications. For a desired system availability, the designer chooses the appropriate length of autonomy based on peak sun hours. See Figure 9-11. Autonomy is the amount of time a fully charged battery system can supply power to system loads without further charging. Autonomy is expressed in days or sometimes in hours. Most stand-alone systems are sized for a system availability of about 95% (about 3 to 5 days of autonomy) for noncritical applications or 99% or greater (about 6 to 10 days or more) for critical applications.

Increasing system availability significantly increases the size and cost of the system. However, each percentage-point increase in system availability is increasingly more expensive for larger battery banks and arrays, which is impractical from an economic standpoint for all but the most critical applications. Sizing of stand-alone systems must achieve an acceptable balance between system availability and cost goals for a given application. See Figure 9-12. The solar resource for a location also affects the increasing costs of availability. Costs for increasing availability rise more steeply for locations with large seasonal differences in insolation than do costs for locations with more constant insolation.

The battery-bank sizing worksheet uses information from the load analysis to determine the required size of the battery bank. Batteries for stand-alone PV systems are sized to store enough energy to meet system loads for the desired length of autonomy without any further charge or energy contributions from the PV array. See Figure 9-13. The amount of battery capacity required for a given application depends on the load requirements and desired autonomy. Greater autonomy requires larger and costlier battery banks, but reduces the average daily depth of discharge, which prolongs battery life.

Due to the allowable depth-of-discharge, low temperatures, and high discharge rates, the amount of useful output in a battery bank is less than the rated capacity. Three factors affect the amount of usable capacity in a battery. These factors are used to estimate the larger battery-bank rated capacity necessary to supply the required output. See Figure 9-14. First, most batteries cannot be discharged to a depth of discharge of 100% without permanent damage. Depending on the battery type, common allowable depths of discharge range from 20% to 80%. Most PV systems use deep-cycle lead-acid batteries, which can be discharged to about 80%. This is the maximum fraction of the total rated capacity that is permitted to be withdrawn from the battery at any time.

The amount of available capacity from a battery bank depends partly on the operating temperature and discharge rate. These factors may have different effects for different batteries. With the minimum expected operating temperature and the average discharge rate, the percentage of usable capacity is determined from a graph of discharge rates and operating temperatures. See Figure 9-15. Most battery manufacturers report capacity at various discharge rates and temperatures in their specifications.

Battery labels list the rated capacity of the battery and important safety information. The nominal voltage and rated capacity of the selected battery is used to determine the configuration of the battery bank. This information is found on battery nameplates or in manufacturer’s literature. See Figure 9-16.

Batteries are configured in series and parallel to match the battery-bank rated capacity needed to produce the required output. The nominal DC-system voltage divided by the nominal battery voltage determines the number of batteries in a string. This number should calculate evenly. See Figure 9-17. The required battery-bank rated capacity divided by the individual-battery rated capacity determines the number of strings to be connected in parallel. This number will likely not be a whole number, but should be rounded up to the nearest whole number. To prevent unnecessarily oversizing the capacity, the battery capacity should be chosen as close to the size required to minimize the amount of rounding.

The array sizing worksheet uses insolation data and load requirements to size the array. For stand-alone systems, the array must be sized to produce enough electrical energy to meet the load requirements during the critical design month while accounting for normal system losses. This ensures that the battery will always be properly charged and that system availability is high throughout the year. See Figure 9-18.

Actual array output is often less than rated output due to soiling, shading, and higher operating temperatures. Just as with battery banks, certain factors reduce the array output from the factory ratings to actual output values. Therefore, these factors are applied to the required array output to determine the necessary increase in array ratings for sizing and module selection. See Figure 9-19.

Modules are configured in series and parallel to match the array rated capacity needed to produce the required output. The number of parallel strings of modules required is determined by dividing the rated array current output by the selected module maximum-power current output and rounding up to the next whole number. See Figure 9-20.