Sales Training Outline 2006 Klaus Tum Product Manager Foot Switches 35 Royal Road Flemington, NJ 908-806-9400 www.altechcorp.com.

Slides:



Advertisements
Similar presentations
Electrical Systems Conductors good electrical conductors.
Advertisements

MANUAL TRANSMISSION ELECTRICAL. OBJECTIVES n Diagnose electrical problems by logic and symptom description. n Perform troubleshooting procedures using.
IntegraPower Features and Models. L1L2L3 T1T2T3 RS-232 cable to PC TB1 connections: Remote ON/OFF Remote indicator light Y-  Control Bypass contactor.
Laszlo Gyorgypal Product Manager 35 Royal Road Flemington, NJ
Circuit Breakers and Busbars. Circuit Breakers Altech’s Circuit Breaker Line UL1077 (R-Series) UL508 (V-EA Series) UL489 (L-Series, AB-Series)
Sales Training Outline 2006 Jeff Roye Product Manager Liquid Tight Strain Reliefs 35 Royal Road Flemington, NJ
Sales Training Outline 2006 Klaus Tum Product Manager Motor Disconnect Switches 35 Royal Road Flemington, NJ
©2011, The McGraw-Hill Companies, Inc. Chapter 4.
The Load Bank of Choice
Graphic Symbol Location 1. DIN Terminal X52 The machine is powered by electricity using copper cable with 5 wires (3 phase wires + neutral wire +
Troubleshooting Aircraft Charging Systems ( Alternators/Reciprocating Engines) by Herb Spenner.
I have almost 20 years experience in the components and devices used in industrial control, instrumentation and automation applications. Before I came.
GO ORDNANCE !!! ORDNANCECORPS 1 Troubleshoot the DC Electrical Control System on the EPP III.
Sales Training Outline 2006 Klaus Tum Product Manager NEW Circuit Breakers 35 Royal Road Flemington, NJ
EE4503 Electrical Systems Design
Welcome DIN Rail product training ISOLATOR/MCB/RCD/RCBO
Sales Training Outline 2006 Jeff Roye Product Manager Industrial Enclosures 35 Royal Road Flemington, NJ
Embedded Programming and Robotics Lesson 1 Basic Electricity and Electronics Transistor Basics Lesson 1 -- Basic Electricity1.
Sales Training Outline 2006 Laszlo Gyorgypal Product Manager European Fuses 35 Royal Road Flemington, NJ
Battery Principles.
Sales Training Outline 2006 Laszlo Gyorgypal Product Manager Push Buttons 35 Royal Road Flemington, NJ
Sales Training Outline 2006 Klaus Tum Product Manager Inductive Proximity Sensors 35 Royal Road Flemington, NJ
Section 4: Electric Motors
Sales Training Outline 2006 Jeff Roye Product Manager DIN Enclosures 35 Royal Road Flemington, NJ
Electrical Electricity Fuses Relays Solenoids Electrical Testing
Basic Electrical Systems Theory and Repair
Rocker Switches  Available in illuminated, Non-illuminated and Central illuminated version  Suitable for switching resistive and inductive load  Wide.
Forging new generations of engineers. Digital Multimeter.
Electricity and Electrical Circuits. Chapter Sections O 1 - Electrical Circuits O 2 - Current and Voltage O 3 - Resistance and Ohm’s Law.
1 Advanced D-TAC Testing. 2 D-TAC testing – Part 2 This presentation is meant to be viewed after the introductory presentation ‘D-TAC testing – Batteries.
© 2008 Snap-on Incorporated; All Rights Reserved.
Electric Circuits A circuit is a path where a current can flow If the flow is to be continuous, the can be no gaps in the path Introduce gaps in the form.
13.2: Current and Voltage Objectives: Ampere Voltage Volt Voltmeter
Electric Circuits Part Two: Current and Voltage Learning Goals  Explain how current flows in an electric circuit.  Define voltage and describe how.
Electric Current and Ohms Law. Electric Current The continuous flow of electric charge –The two types of current are direct current (DC) and alternating.
Notes taken from Gillette’s Designing with Light.
Copyright © 2011 Rockwell Automation, Inc. All rights reserved. Insert Photo Here OneGear™ SMC™ Flex Controller kV.
UNIT FIVE: Electricity and Magnetism
Sales Training Outline 2006 Jeff Roye Product Manager Wire Ducts 35 Royal Road Flemington, NJ
Concepts of Engineering and Technology Basic Electricity and Electronics: DC Circuits Copyright © Texas Education Agency, All rights reserved. 1.
Sales Training Outline 2006 Klaus Tum Product Manager PIN & Sleeve Devices 35 Royal Road Flemington, NJ
Electrical Systems Conductors good electrical conductors.
In this lesson, you will learn how to set up a Digital Multimeter (DMM) to perform various measurements Click on each question to learn more How is the.
Altech History After recognizing a need for European electronic components in American industry, Heinz W. Meise, originally from Germany, founded.
Electronics for Physical Computing Materials: capacitor, diode, LED, transistor, switch,resistor, relay, proto board, multimeter.
5SV9 Residual Current Circuit Breakers with Overcurrent Protection
5SL4 10 kA / 5SL6 6 kA miniature circuit breakers
HOUSE WIRING Final Review. Electricity Electricity = flow of electrons Conductor= electricity passes thru easily - Metal, water, person Insulator = restricts.
HOUSE WIRING NOTES. Electricity  Proton – positive charge  Electron – Negative charge  Electricity = flow of electrons Conductor= electricity passes.
Basic Electrical Systems Theory and Repair Chapter 29 Page 387.
Electricity Unit. What is electricity? Electricity is the movement of electrons through something (“medium”) Electrons move for 2 reasons – They are attracted.
CGS Ground School Technical The Vigilant Electrical System © Crown Copyright 2012 No Part of this presentation may be reproduced without the permission.
Using a Multimeter.
Electrical Systems Conductors good electrical conductors.
Electricity & Magnetism
Starting System Circuit Operation and Testing
ELECTRIC CIRCUITS 20.3.
UNIT FIVE: Electricity and Magnetism
E2 Motors and Motor Starting
Asahi/America Electric Actuators Series 94.
Automotive Service Modern Auto Tech Study Guide Chapter 8
Push Buttons We like when you Push our buttons
Copyright © 2018 W.S. Darley and Company. All Rights Reserved.
MINNY 16 TROUBLESHOOTING Doc THE MACHINE DOES NOT START
Asahi/America Electric Actuators Series 94.
Chapter Twenty: Electric Circuits
Ohm’s Law This formula shows the relationship between current, voltage and resistance. Voltage (Volts) Current (Amps) Resistance (Ohms, )
HUBER+SUHNER ACS Confidential ACS May 2013.
Programmable Logic Controllers (PLCs)
Electricity.
Presentation transcript:

Sales Training Outline 2006 Klaus Tum Product Manager Foot Switches 35 Royal Road Flemington, NJ

Electrical Engineer 10 years with Altech Corporation Product Manager of Circuit Breakers, Busbars, Motor Disconnect Switches, Foot Switches, Sensors, Contactors, Motor Starters, Pin & Sleeve Connectors Klaus Tum (short bio)

Introduction

FM Series Foot Switches Small Size/High Quality Light/Medium Duty Applications Available in Gray, Black, or Off-White Completely customizable with an infinite combination of cable choices, connectors and configurations 5 AMP, 250 VOLT AC electrical rating Available in momentary and maintained configurations Custom color pedals

PCFS-3M Series Foot Switches Compact size Black steel body, with or without guards Up to 10A, (1/2hp) / 125 VAC electrical rating Custom cables and connectors Low cost Made to compete with Treadlite series

FK Series Foot Switches Medium size Available in Gray or Black Higher electrical rating than FM Series Up to 10 AMP, 250 Volt AC electrical rating Custom cables and connectors

FM/FK Switch Configuration

FL Series Foot Switches Medium Size/Heavy Duty Polyamide 6.6 body, pedal and cover Resistant against water, oil and certain chemicals 10 AMP, 500 Volt (20 AMP, 250 Volt) AC electrical ratings

FS Series Foot Switches Heavy Duty/Medium Size Die cast aluminum body and cover; polyamide 6.6 pedal Snap Action or slow make-break switch inserts 10 Amp, 500 Volt (20 Amp, 250 Volt) AC electrical ratings Standard colors: gray body, red cover, black pedal –Custom color are also available

FS Series Foot Switches One, two and three pedal models available All models available with or without foot guards

FL/FS Switch Configuration

Potentiometer Configuration Available in FL/FS series Standard configuration includes microswitch Available with resistance from 100 OHM to 20K OHM (10K OHM standard)

Available Accessories Aluminum pedals Foot guard Anti trip Foot rests Custom cables, connectors

Contact Configurations Momentary (Press to start - Release to stop) Maintained (Press pedal and release, contacts remain in the “on” position, press pedal again and release, contacts are in the “off” position) Two stage (First set of contacts close, when pedal is further depressed past pressure point, second contacts close)

Custom Configurations Custom assemblies Custom colors/ textures Custom cables Custom connectors

IEC for Medical Applications Protection Level IPX8 (Immersion in water) Limited voltage rating to 25V~ (AC)/60V (DC) UL/CSA, VDE approved switch insert Installed cable with special pull/bend protection strain relief Special, modified housing Available with FM, FL and FS Series Foot Switches

Highest quality European components Customizable to any customer’s needs Trained support staff to answer all of your questions Minimal lead time, even for custom applications Excellent technical support Why Altech Foot Switches?