Process and equipment in sterilization

Slides:



Advertisements
Similar presentations
Stop The Leak.
Advertisements

Biological Hazards Routes of Entry
HEATING AIR © Commonwealth of Australia 2010 | Licensed under AEShareNet Share and Return licence.
Fuel System The fuel system supplies the air and fuel necessary for an engine to produce power. The fuel system includes: Air Cleaner Fuel Supply Carburetor.
STEAM TRAPS.
F.3 Chem -- Section Two Handling Chemicals.
1 Waterlines, Biofilms and Water Quality Infection Control, DA116.
Condensation Piping and Installation Drain Pans
Normal Operating Parameters Maintenance Schedule Common Problems Normal Operating Parameters Maintenance Schedule Common Problems ClearWater Tech, LLC.
Copyright © 2013 Wolters Kluwer Health | Lippincott Williams & Wilkins Chapter 6 Infection Control: Clinical Procedures.
3.03 Understand support services
Laboratory Moves. It is important that the laboratory is safe: For custodians to clean For custodians to clean For contractors to work in For contractors.
DENT 1260 IC Unit 5 Unit 5 Sterilization 1. 3 methods of HEAT Sterilization Autoclave- steam under pressure Chemclave- chemical heated under pressure.
POWER PLANT.
AIR COMPRESSORS & STEAM CLEANERS. Pressurized air is produced by an air compressor. Air compressors are used daily in automotive shops. They are used.
Instrument Processing DA 116 Infection Control
What is the autoclave thing again. Sanitization: fancy word for Cleaning Removing of foreign material Dirt, body fluids, lubricants Using detergents,
Micro Practical 3 PRINCIPLE AND WORKING OF AUTOCLAVE Dr. Shahzad Ali Assistant Professor Department of Wildlife and Ecology UVAS, Ravi Campus, Pattoki.
CSULB Department of Biological Sciences Common Use Equipment Training Autoclaves.
Drying Extra slides Mahmoud Teaima, Ph.D..
Domina PLUS B WORKING DIAGRAMS TROUBLESHOOTING INTERNAL VIEWS WIRING DIAGRAMS INSTALLATION 03 PREVIOUS MODEL.
Optimizing your handpiece life! By The Dentist’s Choice.
Autoclave. What is an Autoclave? Autoclave is a pressurized device designed to heat aqueous solutions above their boiling point at normal atmospheric.
Chapter 7: STERILIZATION
8.02 Aseptic Techniques Implement aseptic technique to maintain equipment Images courtesy of google images.
Problem This project was funded by Mr. and Mrs. Charles Fox and Beyond Traditional Borders, which is made possible by a grant to Rice University from the.
DENTAL EQUIPMENT DA 110 Pg’s in lab book Not listed in order
How to make “Touch Free” washing clean better. RYKO Manufacturing Company.
Infection Control.
Investment Foundry. TYPES OF FOUNDRY TYPES OF FOUNDRY 1. Sand Foundry 1. Sand Foundry 2. Investment Foundry 2. Investment Foundry Investment Foundry Process.
Using Sterile Technique to Load a Syringe
Sterilization Equipment. Protective Mask  To protect against chemicals, airborne pathogens, bacteria, and viruses during processing of instruments for.
Tempest Blower SECTION: Tools and Equipment ISSUED: REVISED: ##-####
1. - Condensate pump and feed pump trip! -Turbine trips! 2.
Sterilizers.  Definition of sterile  Free of microorganisms (bacteria) Bacteria  Bacteria can be broken down into two groups  Pathogenic - cause disease.
Play Instructions: 1) Divide into Teams 2) Ask a Question to a Team 3) If correct, click the Spin Wheel Button to choose the number of points that team.
SANITATION PART 2. TYPES OF SANITATION Cleaning – physically removing all visible signs of dirt and organic matter such as feces, blood, hair, ect. Disinfecting.
Lab Activity 4 A. Extraction & Determination of Crude Fat from Plant or Animal Tissues B. Determination of Dry Matter and Moisture Content In Plant Materials.
Introduction to Energy Management. Week/Lesson 9 part a Evaporative Cooling and Cooling Towers.
Chemical Sterilization
Preparation of Supplies for Sterilization. Objectives Explain the steps involved in cleaning, disinfecting, wrapping, and packaging sterile packs and.
STRILIZATION AND DISINFECTION IN A DENTAL CLINIC
Wet Packs: Strategies for Prevention and Resolution
Using Heat Part 2. Science Journal Entry 32 Explain the advantages and disadvantages of thermal expansion.
__________________________ © Cactus Moon Education, LLC. Cactus Moon Education, LLC. CACTUS MOON EDUCATION, LLC ENERGY FROM.
Welcome To PPI Pumps Pvt. Ltd. Introduction about Vacuum Pump Vacuum pump is used to pull air or gases from a confined or sealed space.
Submitted By:Supported By: Suresh Chandra Jangid Branch: - Mechanical (IInd yr. )
3.03 Understand support services PP2
Laboratory equipment Lecture (5).
3.03 Understand support services
14 Refrigerant Recovery, Recycling, and Recharging.
Cleaners Only use cleaners that are: Stable Noncorrosive Safe to use
CENTRAL STERILE SUPPLY SERVICE
Instrument Reprocessing
Medical Waste Management Services in UAE
SB Packing Automatic Downpuller Power Unit
3.03 Understand support services
Infection Control Lesson 3: Surgical Asepsis
Elizabeth Stoneham Kathryn A. Ramirez-Aguilar, Ph.D.
3.03 Understand support services
Introduction of fuel feed system
3.03 Understand support services PP2
1 INTERNATIONAL MARITIME COLLEGE OMAN PROCESS TECHNOLOGY & SYSTEMS (TPTS & PT-TPTS) PE (TPTS & PT-TPTS) (Chapter-3) Chapter - 3 Distillation Systems Textbook.
3.03 Understand support services
 Define: The stirring heating plate or heated stirring heating plate has been developed to heat and mix fluids contained in laboratory receptacles such.
Sterile Technique.
3.03 Understand support services
Laboratory equipment Lecture (9).
3.03 Understand support services
Presentation transcript:

Process and equipment in sterilization

Tool preparation and presoak *We prep all implants used in any given procedure by placing them under running water for about 30sec. *Then we presoak all implants in a chemical bath until the tools are ready to be placed inside the hydrim.

Presoak Optim 33 TB

Surface Disinfectant Optim 33 TB

The Hydrim *After the first two steps of tool processing, the hydrum can be useful for the following : *It eliminates the potential dangers and disaster which can arise in tool scrubbing. *It cuts down a large amount of time the operator must be in contact with any potential biohazard *The Hydim also has a dry cycle which ensures your tools are clean and dry before being bagged and sterilized.

How the hydrim pulls debris from the tools

Cassette and Chamber Autoclaves *What are the differences in gravity displacement autoclaves. *Such as Type N, Type S, and positive displacement. *What are the benefit and drawbacks?

Gravity displacement autoclaves or Type N. *These autoclave our the most commonly used in the tattoo and piercing community. *The name refers to the way air is removed from the chamber. *This design of autoclave generally has a heating element in the bottom of the autoclave chamber, along with a fill hole that transfers water from a reservoir to the autoclave chamber. *The benefit of this type of autoclave is it's simplicity along with being very cost effective.

Positive Pressure Displacement Autoclave *The positive pressure displacement autoclave improves on the design of a gravity displacement autoclave by creating the steam in a separate internal unit or "steam generator” *The steam needed to displace air builds in a separate chamber which opens the check valve and a pressurized burst of steam enters the autoclave chamber, this resulting in a higher percentage of air from the chamber which decreases autoclave cycle times. *Drawbacks high initial cost and a smaller chamber or cassette

Negative pressure displacement Autoclaves or Type S *The negative pressure displacement unit is able to achieve a highest "Sterility Assurance Level" (SAL) *The main difference in this type of autoclave: is when the chamber is closed a vacuum pump removes all the air form the chamber and then the pressurized steam is injected into the chamber. *These also have filtered dry cycles which allows for the packages to completely dry before entering ambient air. *Drawbacks size of unit and high initial cost

Aquastat and Condensation Cubes The Aquastat is used to turn tap water into distilled water, while the Condensation Cubes neatly dispose of the waste water from the back of the Statim Both are relatively cheat and have a great upside. Simple construction so very durable Both are self-contained units meaning no wiring and just a little plumbing for the cubes