BOHB APCCB 2004 1 LABORATORY USE OF THE ABBOTT MEDISENSE METER FOR BETA-HYDROXYBUTYRATE MEASUREMENT. GRD Jones, A Screnci, P Graham Chemical Pathology,

Slides:



Advertisements
Similar presentations
Independent Project HCAI 5221 Evaluation of Point of Care Bedside Glucose Monitors for Use in a Specialty & Transplant Hospital Mary A. Weidner, BS, MT(ASCP)
Advertisements

Palermo – April 26, 2014 Controlling the quality of diagnostic tests E. Bravi.
AACB NSW/ACT QC Subcommittee TnT hs Survey Results Methods Results Introduction Persephone Giannopoulos¹ and representatives of the AACB NSW/ACT QC Subcommittee.
ADULT MALE % BODY FAT. Background  This data was taken to see if there are any variables that impact the % Body Fat in males  Height (inches)  Waist.
“Diagnostic value of procalcitonin in well appearing young febrile infants” Pediatrics 2012; 130:
Clinical Case 3. A 14 year old girl was brought to her GP’s office, complaining of: – weight loss, – dry mouth, – lethargy, – easy fatigability – and.
L MACKAY, N CRINIS, Q LAM, R SCOTT
MHA APCCB A SERUM INDEX FOR METHAEMALBUMIN: THE M-INDEX GRD Jones, M Roser, B Zworestine Department of Chemical Pathology, St Vincents Hospital,
Selection of measuring instruments
1 Role of the Laboratory in Differential Diagnosis of Diabetes Mellitus Dr. Essam H. Jiffri.
Association of 1,5-Anhydroglucitol with Diabetes and Microvascular
8/10/2015Slide 1 The relationship between two quantitative variables is pictured with a scatterplot. The dependent variable is plotted on the vertical.
Kyiv, TRAINING WORKSHOP ON PHARMACEUTICAL QUALITY, GOOD MANUFACTURING PRACTICE & BIOEQUIVALENCE Validation of Analytical Methods Used For Bioequivalence.
Chemometrics Method comparison
Method Comparison A method comparison is done when: A lab is considering performing an assay they have not performed previously or Performing an assay.
Methods to Detect Red Cell Membrane Disorders
APCCB AVERAGE OF DELTA – A NEW CONCEPT IN QUALITY CONTROL GRD Jones Department of Chemical Pathology, St Vincents Hospital, Sydney, Australia.
Methods to Detect Red Cell Membrane Disorders
PG-Seph. APCCB IDENTIFICATION OF MACRO- PROLACTIN WITH PROTEIN-G SEPHAROSE Jones GRD, Giannopoulos P. Departments of Chemical Pathology, St Vincent’s.
Method Selection and Evaluation Method Selection and Evaluation D. Kefaya EL- Sayed Mohamed Prof. Of Clinical Pathology (Clinical Chemistry), Mansoura.
NOVELLO E., MION M.M., ZANINOTTO M., PLEBANI M. Department of Laboratory Medicine, University-Hospital, Padova (Italy). AQT90 FLEX is a fully automatic.
AACB ASM 2003 THE POWER OF ERROR DETECTION OF WESTGARD MULTI-RULES: A RE-EVALUATION Graham Jones Department of Chemical Pathology St Vincent’s Hospital,
SI units, metric units, scientific notation, and dimensional analysis
Analytical considerations
Evaluation of Beckton-Dickinson PST II and SST II Blood Collection Tubes P Graham, B Martin, M Roser, G Jones Department of Chemical Pathology, St Vincent’s.
Applicability of the AGREE II Instrument in Evaluating the Development Process and Quality of Current National Academy of Clinical Biochemistry Guidelines.
PHYSICS WORKSHOP Demystifying 9188/4 Yours truly T.V Madziva or
BY : Dr. Beenish Zaki, Instructor Department of Biochemistry (15 February 2012)
Prof. of Clinical Chemistry, Mansoura University.
Stability APACB MATRIX AND STABILITY STUDY: PTH, INSULIN AND C-PEPTIDE Boscato L, Bayoun R and Jones GRD Chemical Pathology, St Vincent’s Hospital,
G Jones, M Roser Department of Chemical Pathology
BNPCV APCCB BIOLOGICAL VARIATION FOR N-TERMINAL PRO-BNP Jones GRD 1, Bennett A 2,3, Boscato L 1, Macdonald P 2, Brien J 3. Departments of Chemical.
Interferences - are some methods better than others? Graham Jones Department of Chemical Pathology St Vincent’s Hospital, Sydney.
· Lecture 31 & 32 : Scope of clinical biochemistry ط Uses of clinical biochemistry tests ط Diagnosis, Prognosis, Screening, Monitoring ط Reporting results.
Analysis of Variance 1 Dr. Mohammed Alahmed Ph.D. in BioStatistics (011)
Evaluation of the Presage™ ST2 ELISA Jun Lu 1, David G. Grenache 1,2 1 ARUP Institute for Clinical and Experimental Pathology, Salt Lake City, UT 2 Department.
Correlation and Regression. Section 9.1  Correlation is a relationship between 2 variables.  Data is often represented by ordered pairs (x, y) and.
Serum biochemical parameters glucose assay Biochemistry Clinical practice CLS 432 Dr. Samah Kotb Lecturer of Biochemistry 2015.
Recent advances in the monitoring and management of diabetic ketoacidosis by T.M. Wallace, and D.R. Matthews QJM Volume 97(12): November 29, 2004.
Comparability of methods and analysers Nora Nikolac
 Remember Chemistry panel Quality Control:-  In a medical laboratory, it is a statistical process used to monitor and evaluate the analytical process.
RESEARCH POSTER PRESENTATION DESIGN © Cardiac Troponin Assay Cardiac troponin I is the diagnostic marker used for myocardial.
Lecturer: Bahiya Osrah.  It is a chronic disease associated with hyperglycemia (increased blood glucose level) & glucourea (presence of glucose in urine)
Oral Glucose Tolerance Test (OGTT)
Sample Collection Bayer recommendations BNP is unstable in glass containers Recommended sample type is EDTA plasma using plastic tubes for sample collection.
Diagnostic clinical chemistry
Freestyle Precision Pro
Understanding Standards: Advanced Higher Physics
Clinical practice involves measuring quantities for a variety of purposes, such as: aiding diagnosis, predicting future patient outcomes, serving as endpoints.
Value of the chemiluminescence Elecsys antimullerian hormone assay for the assessment of the ovarian follicle pool: preliminary study at the IASO- IVF.
NEQAS Survey 212 Factor IX 15/24
Estimation of blood glucose in diabetes mellitus
EVALUATION OF HEMOCHROMA POC Hb READER
A.J. Bakker, D. Jager, G. Dijkstra
Presented by Harry C. Elinsky, Jr. Filtech, Inc.
Height and Pressure Test for Improving Spray Application
From: Diagnostic Accuracy of an “Amended” Insulin–Glucose Ratio for the Biochemical Diagnosis of Insulinomas Ann Intern Med. 2012;157(11): doi: /
Plasma Components Affect Accuracy of Circulating Cancer-Related MicroRNA Quantitation  Dong-Ja Kim, Sarah Linnstaedt, Jaime Palma, Joon Cheol Park, Evangelos.
Plasma Components Affect Accuracy of Circulating Cancer-Related MicroRNA Quantitation  Dong-Ja Kim, Sarah Linnstaedt, Jaime Palma, Joon Cheol Park, Evangelos.
by James D. Cook, Carol H. Flowers, and Barry S. Skikne
Nat. Rev. Nephrol. doi: /nrneph
Evaluation of the Cepheid GeneXpert BCR-ABL Assay
Method Selection and Evaluation
Graphs in Science.
Comparison of QIAsymphony Automated and QIAamp Manual DNA Extraction Systems for Measuring Epstein-Barr Virus DNA Load in Whole Blood Using Real-Time.
Jesse L. Montgomery, Nick Rejali, Carl T. Wittwer 
Validation of Clinical Testing for Warfarin Sensitivity
Evaluation of the Abbott Investigational Use Only RealTime HIV-1 Assay and Comparison to the Roche Amplicor HIV-1 Monitor Test, Version 1.5  Michael T.
Graphs in Science Chapter 1, Section 5 Page 34.
Practical Blood Bank Lab 11 Cyroglobulin.
Presentation transcript:

BOHB APCCB LABORATORY USE OF THE ABBOTT MEDISENSE METER FOR BETA-HYDROXYBUTYRATE MEASUREMENT. GRD Jones, A Screnci, P Graham Chemical Pathology, St Vincent’s Hospital, Darlinghurst, NSW 2010.

BOHB APCCB Background Keto-acidosis is a potentially life-threatening complication of Type 1 diabetes mellitus. Beta-Hydroxybutyrate (BOHB) is the best marker for this complication 1. Current tests for ketones are wet chemistry laboratory tests for BOHB or dipstick tests for acetoacetate. Low volume testing on automated analysers is not cost effective. Abbott has developed a near-patient test for BOHB on the Medisense meter. We evaluate the Abbott test for use in the laboratory.

BOHB APCCB Requirements for Laboratory Testing The Medisense meter is designed for near-patient testing using a whole blood fingerprick sample. In the laboratory samples are subject to other variables: –Effects of different sample anticoagulants –Delays in sample arrival –Requests for add-on tests on old samples There is also the opportunity to improve control of such factors as sample volume and to perform additional functions such as sample dilution.

BOHB APCCB Aims To evaluate the Abbott Medisense meter for BOHB measurement in a laboratory environment. This includes assessment of: –Sample types –Precision –Sample stability –Effect of short sample volume –Sample Dilution Note: Accuracy has previously been addressed in the literature 1,2 and does not form part of this evaluation.

BOHB APCCB Medisense BOHB Assay Product Insert Claims –Immediate measurement of whole blood –Heparin whole blood suitable and stable for 30 mins –Serum or plasma is not recommended. –Fluoride oxalate whole blood unsuitable. –Other sample types not mentioned –Suitable for haematocrit range 30% to 60%. –5 uL sample volume –Range mmol/L –Results in 30 seconds

BOHB APCCB Methods Sample Types –The following sample types were evaluated: –EDTA whole blood (WB), heparin WB, EDTA plasma, heparin plasma, Fluoride oxalate WB. Stability –Sample stability was assessed room temperature and 4°C. Dilution –Linearity of whole blood dilution was assessed. Sample volume –Accuracy at low sample volume additions. Acceptance Criteria for this study Up to +/- 0.7 mmol/L below 3.5 mmol/L, then 20% This criteria allows clear separation of DKA from normals 3

BOHB APCCB Sample Comparison Heparin Whole Blood BOHB (mmol/L) BOHB (mmol/L) BOHB Difference (mmol/L) Figure 2. Scatter plot (A) and Difference plot (B) for EDTA WB (blue diamonds, ) and Fluoride Oxalate WB (red squares, ) compared to heparin WB. The acceptance limits (+/- 0.7 up to 3.5 mmol/L, then 20%) are shown in purple. Solid line in A is the line of identity, dashed line is the line of best fit for EDTA samples. Interpretation: EDTA and Fluoride Oxalate WB results are equivalent to Heparin WB results. A B

BOHB APCCB Precision Figure 3. Within-run precision was evaluated by duplicate testing of whole blood samples. The graph shows the difference between paired paired measurements of EDTA WB (blue diamonds, ) and heparin WB (green squares, ). The overall CV was 8% for EDTA and 7% for heparin samples ( highest EDTA outlier was excluded from CV calculation). Interpretation: Whole blood precision is acceptable. BOHB (mmol/L) Difference (mmol/L)

BOHB APCCB Sample Stability Figure 4. Sample stability at Room temperature (A) and 4 degrees (B) for EDTA WB (blue diamonds, ), heparin WB (green triangles, ) and Fluoride oxalate WB (red squares, ). Change is expressed as a fraction of the Acceptance Criteria (AC) on the Y axis. Interpretation: Most samples are stable for at least 24 hours at room temperature and 3 days at 4 degrees. A. room temperature B. 4°C Time (hours) Change (fraction of AC)

BOHB APCCB Whole blood dilution Figure 5. Dilution of BOHB-containing whole blood samples in BOHB-free whole blood. EDTA samples (blue diamonds, ), Heparin sample (green triangles, ). Dashed line is line of identity of expected results. Interpretation: Dilution in whole blood is not linear. Predicted BOHB (mmol/L) BOHB result (mmol/L)

BOHB APCCB Sample Addition – low volumes Figure 6. Addition of low sample volumes. Two heparin whole blood samples tested at progressively lower volumes. Red line shows average of higher volume addition. Note stated minimum is 5 uL. Interpretation: Addition of sample volumes less than 10 uL may give misleading results. A minimum of 20uL sample volume is recommended. Sample Volume (uL) BOHB Result (mmol/L)

BOHB APCCB Conclusions The Abbott Medisense BOHB system is suitable for laboratory use, providing a simple, robust technology for use on EDTA and heparin whole blood samples stored for up to 3 days at 4 degrees or 1 day at room temperature. Fluoride oxalate whole blood appears to be satisfactory. All results were within the stated performance criteria. Care must be taken to ensure sufficient sample volume. Dilution of high samples is not supported. Acknowledgement We thank Abbott Diagnostics for supply of reagents. References 1. Chiu RKW et al. Evaluation of a new handheld biosensor for point-of-care testing of whole blood beta-hydroxybutyrate concentration. HKMJ 2002;8: Wallace TM et al. The hospital and home use of a 30-second hand-held blood ketone meter: guidelines for clinical practice. Diabetes UK 2001;18: Guidelines and Recommendations for Laboratory Analysis in the Diagnosis and Management of Diabetes Mellitus. NACB