A Seminar on VALIDATION OF COMPRESSED AIR

Slides:



Advertisements
Similar presentations
IMO 107(49)/46 CFR ppm Bilge Separators 15 ppm Bilge Alarms
Advertisements

Antero Punttila Analyzing most typical energy saving measures Energy Efficiency of Steam and Condensate Systems Antero Punttila, Motiva Oy.
Radiopharmaceutical Production
HF Series Compressed Air Filters Flows from 20 to 21,250 scfm (34 to m 3 /h) Maximum working conditions of 300 psig & 150°F (21 bar, 66°C)
World Health Organization
EQUIPMENT VALIDATION.
Overview of Validation Requirements Pharmaceutical Industry
Clean Air Boxes CABs RAMs CO Monitors. Features at a Glance Grade D Compliance Grade D Compliance Auto Calibration Auto Calibration Warning Systems Warning.
A Seminar on 1.  Validation vs Qualification  Why to validate?  Who should do Equipment Validation?  Parts of Equipment Validation  Validation of.
Student Book © 2004 Propane Education & Research CouncilPage Performing Pressure Tests on Gas Distribution Lines Gas personnel must understand.
C oncerns Ltd ool Energy Efficient Refrigeration Jane Gartshore, Cool Concerns Ltd.
Installation and Initial Start Up by Martin Noska, Service Engineer, Aftersales & Service.
World Health Organization
Hydraulics.
Quality control of raw materials In-process control
Product Introduction.
A seminar On Validation Of Ampoule Filling & Sealing Machine
Validation SAPRAA March 2013.
World Health Organization
Validation Chapter 4 1. Validation Exemplifies Process Understanding 2.
WHO Supplementary Training Modules GMP
Qualification of HVAC systems
ACADs (08-006) Covered Keywords Air compressors, aftercooler, afterfilter, moisture separator airflow. Description Supporting Material
MCC PRESENTATION - GMP MANUFACTURING ENVIRONMENTS
Huzairy Hassan School of Bioprocess Engineering UniMAP.
Radiopharmaceutical Production
A Seminar on 1.  Why to validate?  Parts of Equipment Validation  Who should do Equipment Validation?  Equipment qualification  Typical process flow.
1. Footer Date CPP OWS and Filters Chicago Pneumatic People. Passion. Performance.
FHM TRAINING TOOLS This training presentation is part of FHM’s commitment to creating and keeping safe workplaces. Be sure to check out all the training.
CHAPTER 4 CPB 20004: Plant Utility n Maintenance
Air-Source Heat Pumps I North Seattle Community College HVAC Program Instructor – Mark T. Weber, M.Ed. Airsource Heat Pump 1.
HYDRAULICS & PNEUMATICS
VALIDATION METHODOLOGY
© 2009 Michigan State University licensed under CC-BY-SA, original at Water Quality.
World Health Organization
Module 1, Part 3: Process validation Slide 1 of 22 © WHO – EDM – 12/2001 Validation Part 3: Process validation Supplementary Training Modules on Good Manufacturing.
FDA Recommendations: Sampling Plans for Blood Establishments Lore Fields MT(ASCP)SBB Consumer Safety Officer OBRR/CBER/FDA October 19, 2012.
Forging new generations of engineers. Basic Pneumatics.
REFRIGERATION SYSTEMS
Expectations for Facilities & cGMPs Biological Response Modifiers Advisory Committee Meeting October 9, 2003 Nicholas Obiri, Ph.D. CBER.
Pressure-Enthalpy and the Variable Refrigerant Cycle
Validation | Slide 1 of 27 August 2006 Validation Supplementary Training Modules on Good Manufacturing Practice WHO Technical Report Series, No. 937, 2006.
Emission source sampling and monitoring Topic 6 Ms Sherina Kamal May
Wet Packs: Strategies for Prevention and Resolution
BASIC AUTOMATIC CONTROLS UNIT 16 ADVANCED AUTOMATIC CONTROLS
MECH1300 Pneumatic Components Topics Pneumatic Cylinders Pneumatic Motors Other Pneumatic Actuators Pneumatic Directional Control Valves Pneumatic Flow.
Sterile Products Lab PHT 434
 2007 Kaeser Compressors, Inc., USA (V5.0) 1 Kaeser Compressed Air Filters Specifications are subject to change without notice.
Industrial Resources, Inc.
ME444 ENGINEERING PIPING SYSTEM DESIGN
BSB Biomanufacturing CHAPTER 11 GMP – Pharmaceutical Water
Microwave Soil Vapor Treatment
Author: Nurul Azyyati Sabri
GOOD MANUFACTURING PRACTICE FOR BIOPROCESS ENGINEERING (ERT 425)
World Health Organization
GOVERNMENT ENGINEERING COLLEGE DAHOD
14 Refrigerant Recovery, Recycling, and Recharging.
Heat Transfer and Refrigeration Cycle
Author: Nurul Azyyati Sabri
High Quality Ammonia purifier for Refrigeration Plants | Maniks
Quality Systems in a Production Facility
Part 2 – Supplied-air Respirators
Air Conditioning System-1
BASIC PNEUMATICS.
By: JAGDEEP SANGWAN Refrigeration Basics 101.
Sterile Products Lab PHT 434
Large Air Systems – Sales Training
Pneumatic System Conditioning
Presentation transcript:

A Seminar on VALIDATION OF COMPRESSED AIR

CONTENT Introduction How Compressed Air System(CAS) works? Test functions and Acceptance criteria Validation protocol : Installation Qualification (IQ) Operational Qualification (OQ) Performance Qualification (PQ) Applications How to gain efficiencies and power savings? References

Introduction What is compressed air? Commonly called Industry's Fourth Utility Air that is condensed and contained at a pressure that is greater than the atmosphere The process takes a given mass of air, which occupies a given volume of space, and reduces it into a smaller space. In that space, greater air mass produces greater pressure. The pressure comes from this air trying to return to its original volume It is used in many different manufacturing operations. A typical compressed air system operating at 100 psig (7 bar) will compress the air down to 1/8 of its original volume. (figure CA1-1)

Compressed air is an important component of pharmaceutical manufacturing facilities It provides many of the air types necessary for a manufacturing facility to function, including: breathing air , motive air for machines , process air , analytical air and Product Direct Impact , or "cGMP" air The application for which the compressed air will be used will dictate the level of air quality that is appropriate for use There are two main categories of applications: Direct Impact Systems and Indirect Impact System

Direct Impact Systems : The systems will have direct contact with the product The system will provide an excipient, or produce an ingredient or solvent The system will be used in cleaning or sterilizing The system will preserve product status The system will produce data which is used to accept or reject the product The system will be a process control system that can affect product quality and there will be no system for independent verification of control system performance

Indirect Impact or No Impact Systems : The system will not contact the product or materials that ultimately become part of the product The systems are generally site or building systems and are not tailored specifically to aseptic manufacturing facilities The systems will deal with a side activity of the manufacturing process (such as waste disposal)

How the Compressed Air System(CAS) works? Each component in a typical system helps to deliver clean, dry, compressed air that’s free of pressure fluctuations at its point of use If any component is working inefficiently, the system’s performance suffers and operating costs rise Like any high-pressure system, they are prone to leaks or other failures that can result in lower performance

Typical Compressed Air System Layout :

Components of the CAS system Inlet filter: Removes particles from the air entering the compressor Compressor : Compresses air to a small volume, increasing the pressure (Reciprocating compressors are frequently used) Motor : Drives the compressor Compressor Controller : Directs the compressor’s output and it may be microprocessor, electromechanical or pneumatically based

Aftercooler : Compression leaves the air hot and wet. The aftercooler lowers the temperature of the air leaving the compressor and removes water that condenses as the air cools Separator : Removes liquids from the compressed air Receiver : Stores a large reserve of compressed air to maintain a smooth flow to the plant Air line Filter : Removes solids and liquids from the compressed air stream. Can be placed throughout the system

Dryer : - Helps to eliminate any remaining moisture in the compressed air by using either a refrigerated condenser or a desiccant - Refrigerated condensers cool the air to condense water vapours into a liquid that is then drained from the system. Desiccants are powders or gels that remove water by absorbing it Condensate Trap : - Collects and discharges liquid that condenses out of the air stream - Integral part of aftercoolers, dryers and separators

Distribution Piping : Links the components. It distributes the air from a main header to branch lines and sub headers to drop points connected to individual tools Pressure regulator : Controls air pressure and flow at individual points of use

Test Functions : Perform Installation Qualification Perform general operational controls verification testing Operate system throughout the range of operating design specifications or range of intended use Verify that the compressed air system is capable of supplying pressurized compressed air to all use points. Perform an operational test of the distribution system and pressure regulators by monitoring the pressure output at the respective use points

Perform a capacity test to verify that the system is capable of supplying the required gas, pressure, and flow rate at each use point Verify that in-line filters are integrity tested. Confirm that all documentation clearly indicates acceptable test results Perform dew point measurement Perform hydrocarbon content measurement Perform viable particulate count, microbiological at critical use points after sterile filters (refer to Federal Standard 209E)

Identification of oxygen content Record the range of all process or equipment parameters (set points, flow rates, timing sequences, concentrations, etc.) verified during Operational and Performance Qualifications testing

Acceptance Criteria : The system is installed in accordance with design specifications, manufacturer recommendations and cGMPs. Instruments are calibrated, identified, and entered into the calibration program General controls, alarms, and interlocks operate in accordance with design specifications The system operates in accordance with design specifications throughout the operating range or range of intended use The compressed air distribution system must consistently deliver pressurized compressed air to the use points at the design pressure as specified

All in-line filters are integrity tested and qualify per manufacturer’s operating specifications Dew point must be <0° or lower Hydrocarbon content must be ≤ 1 ppm Viable particulate must be ≤ 1.0 cfu/10 ft3 Nonviable particulate counts must be ≤ 100/ft3 of 0.5μ or larger at all critical use points

Method for Dew point and Oil content As per Air Quality Standards ISO 8573 and Filter Standard ISO 12500 for compressed air there are nine part to it as follows : Part 1 - Contaminants and Purity classes Part 2 - Test methods for aerosol oil content Part 3 - Test methods for the measurement of humidity Part 4 - Test methods for solid particle content Part 5 - Determination of oil vapor and organic solvent content Part 6 - Test methods for gaseous contaminant content Part 7 - Test method for viable microbiological contaminant content Part 8 - Test methods for solid particle content by mass concentration Part 9 - Test methods for liquid water content

Validation Protocol : It includes : Installation Qualification Operational Qualification Performance Qualification Final Report

Installation Qualification (IQ) This section establishes documented verification that key aspects of equipment adhere to approve design intentions and recommendation of manufacturer have been suitably consider In addition to the common requirements outlined in the "General" section, the following are required for Distribution systems The piping should be supported, labeled, and sloped to drain completely

Contd… Materials of construction will vary with gas type, and must agree with specification Verify that in-line filters can be integrity tested Verify that the systems have been thoroughly cleaned and dried before operation

Operational Qualification This section Establishes that there is a documented verification that the installed system functions as a specified and that there is a sufficient documentary evidence to demonstrate this The OQ protocol will outline tests to study capacity and pressure during estimated minimum and maximum use

Contd… All use points supply the specified pressure prior to any pressure reducing valves or equipment All use point supply the volume of gas as specified Each peak load use point as specified by use or equipment

Performance Qualification This section gives documented verification that the equipment performance in its normal operating environment is consistently exactly as specified in User Requirement Specification (URS) Testing will include viable and total particulate counts, dew point, hydrocarbon analysis, and purity analysis Each point of use will be tested at least three times over 10 working days. Every use point of the system must be tested several times over the course of the study.

Contd… Hydrocarbon Monitoring should show less than 0.2 mg/m3 (25 mg/125 liters) detected. (the lower limit of a Dragger tube) The highest total particulate count from the five one-minute runs must meet class 100 or EC Class A criteria Viable Monitoring (not needed of integrity tested final filter is in place) less than 0.03 CFU/ft3 or less than 1 CFU/m3 Since the gas is field sampled under non-sterile conditions, a few sporadic, individual, tests may fail. Persistent test failures with any individual test, or group of tests, will indicate a system failure

Contd… The dew point of compressed air less than or equal to -10°C, or less than the lowest temperature to which the system is exposed Identity and Purity (Nitrogen) Not less than 99.0% nitrogen by volume. Not more than 0.001% Carbon Monoxide. No appreciable odor Identity and Purity (Oxygen) Not less than 99.0% Oxygen by volume. No appreciable odor

Final Report Depending on IQ , OQ and PQ data final report is made and that will indicate whether your system is validated or not

Applications : Level of application Function Shop air (Filtered centrifugal separator) Air Tools, Sand Blasting, Pneumatic Control Systems (Dryer and Air line filter) Removes solids 3 microns & larger, 99% of water droplets, & 40% of oil aerosol Removes moisture producing a 35° to 50°F (-1.67° to 10°C) pressure dew point, removes 70% of oil

Contd… Function Level of Application Removes moisture & produces a 35° to 50°F (-1.67° to 10°C) pressure dew point, removes 99.999% of oil aerosols, and all particles .025 microns and larger Removes moisture & produces a 35° to 50°F (-1.67° to 10°C) pressure dew point, removes 99.999% of oil aerosols, all particles .025 microns and larger, oily vapor, oily smell, & oily taste Instrument Air, Paint Spraying, Powder Coating, Packing Machines (Dryer, Oil remover filter) Indoor Applications, Food Industry, Dairy Industry, Laboratories (Dryer , Filter and Oil vapour absorber)

Contd… Level of Application Function Breathing Air (continuous or portable) Removes harmful compressed air contaminants and will produce Grade D breathing air

How to get efficiency and power savings? Establish regular maintenance programme Hunt for air leaks Educate your plant staff and emphasizing the importance of monitoring the line Check system operating pressure

References Agalloco James, Carleton J. Fredric “Validation of Pharmaceutical Processes”; Third edition Syed Imitiaz Haider, Pharmaceutical Master Validation Plan, The ultimate guide to FDA , GMP and GLP compliance Syed Imtiaz Haider, “Validation Standard Operating Procedure”,2nd Edition www.usvalidation.com http://www.validationwhat.com/compressed-air-quality.html http://validationworld.com