Current Integrators In proton radiotherapy, dosimeters are used in two distinct ways: as beam monitors, to end the treatment at the prescribed dose, and.

Slides:



Advertisements
Similar presentations
Introduction to Semiconductor Devices
Advertisements

An Electronic System Power Supply Example
By: Alex Sowa Electrical Projects April 10 th, 2013.
» When you have completed this module you will know, what components do, what they physically look like and how they are represented in a circuit diagram.
Diode Dosimeters Semiconductor diodes are inexpensive, yield high output, and do not require bias, making possible simple detector arrays to measure transverse.
Digital to Analog and Analog to Digital Conversion
Interfacing Analog and Digital Circuits
Applications Team Sensing Products
VOLTMETER LOADING EFFECTS
1 Chapter 27 Current and Resistance. 2 Electric Current Electric current is the rate of flow of charge through some region of space The SI unit of current.
Copyright by UNIT III DC Choppers 4/17/2017 Copyright by
EKT214 - ANALOG ELECTRONIC CIRCUIT II
© 2012 Pearson Education. Upper Saddle River, NJ, All rights reserved. Electronic Devices, 9th edition Thomas L. Floyd Electronic Devices Ninth.
Classification of Instruments :
Physics and Electronics. Electronic systems Electronic systems are made up of 3 parts: 1)An INPUT SENSOR – these detect changes in the environment Examples:
Diodes Analog Electronics UNIT III. Diodes UNIT I Objective The student will use diodes, capacitors, regulators and LEDs through a rectifying system in.
Ion Collectors and Detectors
A pixel chamber as beam monitor for IMRT S. Belletti 4, A.Boriano 6, F.Bourhaleb 5,7, R. Cirio 6, M. Donetti 5,6, B. Ghedi 4, E. Madon 2, F. Marchetto.
Slide # 1 Examples of pressure sensor packaging Temperature characteristics of a piezoresistive pressure sensor. Transfer function at three different temperatures.
Lecture # 10 &11 REGULATED POWER SUPPLIES
Electronic Devices Ninth Edition Floyd Chapter 13.
Chapter 22 Alternating-Current Circuits and Machines.
CHAPTER 6 VOLTAGE REGULATOR POWER SUPPLIES (VOLTAGE REGULATORS) Fig. 6.1 Block diagram showing parts of a power supply. Power supply Power supply: a.
Power Electronics and Drives (Version ) Dr. Zainal Salam, UTM-JB 1 Chapter 3 DC to DC CONVERTER (CHOPPER) General Buck converter Boost converter.
Introduction to Transistors
Digital Correlated Double Sampling for ZTF Roger Smith and Stephen Kaye California Institute of Technology The digital equivalent of dual slope integration.
Chapter 26 Lect. 11: Current. Electric Current Electric current is the rate of flow of charge through some region of space The SI unit of current is the.
Power Supply Design J.SHANMUGAPRIYAN.
Electronics for PS and LHC transformers Grzegorz Kasprowicz Supervisor: David Belohrad AB-BDI-PI Technical student report.
Diodes and Diode Circuits
Analog and Digital Instruments
What is RAM? Nick Sims.
CHAPTER 11 Op-Amp Applications. Objectives Describe and Analyze: Audio mixers Integrators Differentiators Peak detectors Comparators Other applications.
Data Acquisition Dr inż. ZDZISŁAW PÓLKOWSKI Polkowice, 2015 University of Pitesti Dolnośląska Wyższa Szkoła Przedsiębiorczości i Techniki w Polkowicach.
ANALOG CIRCUIT AND DEVICES 10/7/ Semester I 2013/2014 Course Code: EEE 3123.
DESIGNING A TEMPERATURESENSOR DESIGNING A TEMPERATURE SENSOR We will be using the following format for designing this circuit: CONTROLOUTPUTINPUT.
Chapter 6 Voltage Regulators By En. Rosemizi Bin Abd Rahim EMT212 – Analog Electronic II.
Chapter 6 Voltage Regulators - Part 2-.
CHEM*3440 Operational Amplifiers These integrated circuits form the backbone of modern instrumental methods. Understanding their operation will help you.
Chapter 26 Lecture 22: Current: II
Basic Electronics for Arduino -basic electronics -arduino related stuff -tips and tricks Rob Zimmermann 2015.
Electronic. Analog Vs. Digital Analog –Continuous –Can take on any values in a given range –Very susceptible to noise Digital –Discrete –Can only take.
EMT212 – Analog Electronic II
BeamCal Electronics Status FCAL Collaboration Meeting LAL-Orsay, October 5 th, 2007 Gunther Haller, Dietrich Freytag, Martin Breidenbach and Angel Abusleme.
1.0 LINEAR DC POWER SUPPLY The importance of DC Power Supply Circuit For electronic circuits made up of transistors and/or ICs, this power source.
Power Supply Design. Power Supplies For most electronic devices it is necessary to provide a stable source of DC power. Batteries often serve this function.
Self Switching Power Supply. Introduction Self Switching Power Supply  Embedded system requires a regulated power supply.
Solar Power Charge Controller. Solar Power Charge Controller Introduction  A charge controller, or charge regulator is basically.
Chapter 9 CAPACITOR.
PCAR Precision In Practice 1 Precision In Practice Achieving the best results with precision Digital Multimeter measurements Paul Roberts Fluke Precision.
FUNCTION GENERATOR.
Chapter 6: Voltage Regulator
MECH 373 Instrumentation and Measurements
Mrs V.S.KharoteChavan,E&Tc,PC poly
CHARGE AND LOAD PROTECTION IN SOLAR POWER MANAGEMENT
CHAPTER 6 VOLTAGE REGULATOR Tulus Ikhsan Nasution.
SAR ADC Input Types TIPL 4003 TI Precision Labs – ADCs
Introduction to Semiconductor Devices
Electronic Devices Ninth Edition Floyd Chapter 17.
Rectifiers and Filters
Dr: Mohamed Afifi By Lecturer Radiological Science
Fault detection Lecture (3).
Unit - 5 Analog and Digital Instruments. Digital Voltmeter (DVM) Used to measure the ac and dc voltages and displays the result in digital form. Types:
Unit IV 555 Timer.
Pulse Processing Chapter No. 17
Chapter 6: Voltage Regulator
Basic Electronics Part Two: Electronic Components.
Analog and Digital Instruments
SOLAR POWER CHARGE CONTROLLER
ECE 3336 Introduction to Circuits & Electronics
Presentation transcript:

Current Integrators In proton radiotherapy, dosimeters are used in two distinct ways: as beam monitors, to end the treatment at the prescribed dose, and for QA, usually in arrays, to measure the lateral or depth dose distribution. In either case, considerable thought should be given to the electronics that processes the output. Some commercial systems sample the output current, which varies of course with the time structure of the beam. To eliminate very fast variations, the current may be filtered, or data may be smoothed in software, or both. Beam intensity variations during the scan may be canceled by measuring the instantaneous ratio of the ‘field chamber’ current to a ‘reference chamber’ current. We prefer to integrate the current, measuring the total output charge. That extracts the maximum possible information from the signal and makes filtering, with its somewhat complicated time response, unnecessary. The integration time can be very short if desired. If information about the absolute charge is preserved, a transverse or depth scan using N beam monitor units per point simultaneously measures the monitor’s output factor. Most commercial hardware/software, however, does not work that way. An array of dosimeters (IC’s or diodes) requires an array of integrators, and that can be more challenging and expensive than the detector itself. There are two kinds of integrators: classical and recycling. Both can be used either singly or in arrays, using either discrete integrated circuits or ASIC’s (Application Specific Integrated Circuit).

Classical and Recycling Integrators Classical integrator. When the voltage across C1 reaches some level, discharge C1 by closing the switch. During this time, current is lost. Accuracy depends on the stability of C1 (no problem) and the stability of the threshold level. Residual charge at the end of measurement may be significant. Recycling or ‘charge-balancing’ integrator or ‘current to frequency converter.’ Subtracts a charge quantum ΔQ and issues an output pulse whenever the voltage on C1 reaches threshold. Accuracy depends only on the stability of ΔQ. No deadtime. Good fit to control system. Drawings from Lewis and Collinge, ‘A precision current integrator of medium sensitivity,’ Rev. Sci. Instr. 24 (1953) 1113. Analogy: measuring flow rate from a faucet with a bucket. Classical : when water reaches a certain level, empty the bucket and increment a counter. You lose water while you empty the bucket. Recycling : when water reaches the level, remove an accurate dipper full of water and increment a counter. You lose no water, and in a long measurement (many counts) only the accuracy of the dipper matters, not exactly when you dip it into the bucket.

Classical Integrator From B. Gottschalk, ‘Resetting a current integrator with the supply lines,’ Nucl. Instr. Meth. A297 (1990) 534. Instead of using a relay or transistor, this integrator is reset by reversing the supply lines through current limiting resistors. That effectively puts the capacitor inside a conducting diode bridge. This circuit has a very low parts count which, along with the ‘memory’ provided by the integrating capacitor, makes it ideal for arrays read out by a single scanning ADC. The input burden, a few μV from ground, makes it ideal for diode arrays as well. This is the array integrator used in the CROSS and MLIC detectors. System sensitivity 2.44 pC/count, range ±5 nC, leakage current ≈ 0.3 pA.

A Diode Array The 32 × 32 ‘CROSS’ diode array built for QA in the HCL radiosurgery beam and now used for general purposes at the Burr Center. 1N4004 diodes are mounted on perfboard at 0.2″ pitch. Leads not at ground are covered with insulating paint to discourage ion collection. The diodes put out so much signal (130 pC/rad) that they will not reach the 10 Krad damage threshold in the lifetime of the device, so they are not pre-irradiated.

Real-Time Output On-line displays on the PC running the CROSS array. The measurement shown took two seconds. Array devices take longer to set up than to use so ease of setup should guide the mechanical design. Data should be recorded in a compact and automatically named log file with no operator response needed. Diodes are recalibrated annually by exposing CROSS to a Gaussian dose distribution at several preset positions. The 64 diode constants and a few parameters for the unknown dose distribution are thus overdetermined, and found by a least-squares fit.

64 Channel Classical Integrator Array This array is used at the Burr Center for CROSS and MLIC. A second unit houses a scanning ADC to read the integrators and transmit data to a host computer via RS-232.

Recycling Integrator See B. Gottschalk, ‘Charge-balancing current integrator with large dynamic range,’ Nucl. Instr. Meth. 207 (1983) 417. This slide shows an updated version used in the IBA nozzle. ΔQ = 10 pC (R4), max counting rate 2 MHz corresponding to 20 A. Unipolar: sinks current, so it works with proton collectors. Input burden a few ±μA (R8) so it also works with diodes. Leakage ≈0.04 pA. When used as beam monitor, residual charge is negligible.

Stand-Alone Recycling Integrator Single channel line powered recycling integrator used with beam monitor IC’s at HCL and for general purposes at the Burr Center. Sinks charge, puts out a pulse for every 10 pC.

Rate Dependence of Charge Quantum ΔQ is independent of input current over >7 decades to ±0.2%. Even during a hypothetical high-current accident this circuit will keep track of the dose delivered.

ΔQ Tempco for 16-Channel ICEU Board Analog circuits always have temperature dependence, which is tricky to measure because the board must be heated or cooled uniformly. Without compensation, the recycling integrator has a temperature coefficient (‘tempco’) of ≈ -0.25%/°C. It can be compensated by varying ‘+5 V’ very slightly. That adjusts ΔQ without significantly affecting circuit operation. The integrators are packaged 16/board. Though they all have slightly different tempcos, this slide shows that a single compromise setting reduces the net tempco by roughly 5×. The circuits have proved sufficiently stable in about 10 years of service in the IBA nozzle.

General-Purpose Integrator Array: Specs The future, especially as beam scanning becomes more common, will see greater use of detector arrays: multi-layer IC’s, diode arrays and multi-layer Faraday cups. Frequently the detector itself will be home-built for a specific application, but all such detectors will require current integrator arrays. At present (2008) no fully satisfactory integrator array is commercially available. A general purpose integrator should meet the following specs: 1. Type: for QA, either classical or recycling is acceptable because some dead time is tolerable. For the beam dosimetry monitor, a recycling integrator is required. 2. Polarity: the integrator should be bipolar to allow leakage current of either sign to be measured. If it must be unipolar, it should sink current to work with Faraday cups. 3. Input level: the input should be at ground to simplify guarding of the detector. 4. Input voltage burden: should be adjustable and stable to ≈1μV if integrator is to be used for diode arrays. Other detectors don’t care. 5. Sensitivity: 1 pC/count or better if possible. 6. Range (if classical): ±5 nC. 7. Synchrony: integrators serving the same beam line should be strobed at nearly the same time. Total scan time ≈ 1 msec (≈ 5 μsec/channel) would allow reading ‘on the fly’ (beam on) in many cases.

Summary QA in a proton therapy facility can be accomplished by current measuring circuitry, but current integrators (reading per accumulated charge) are preferable, and for the dosimetry channel, required. Two circuit forms are available: classical and recycling. Classical integrators have fewer parts per channel and are potentially less expensive in large arrays, but have some dead time associated with the reset requirement. This should not matter much in QA since it amounts only to wasting a small fraction of beam-on time, but it is not acceptable in the dosimetry channel. Operation over a wide range of input current should be considered and checked, as well as the temperature coefficient of calibration. We have discussed specifications for a general-purpose integrator array: bipolar or positive input, input at ground, input voltage burden ≈1μV and stable, small charge quantum, synchronizable to read multiple detectors simultaneously. It would be useful to budding proton therapy facilities if a general purpose Ethernet based integrator array were offered for sale, with suitable low-level software.