Introduction (2/2) – Comparison of Modalities Review: Modalities: X-ray: Measures line integrals of attenuation coefficient CT: Builds images tomographically;

Slides:



Advertisements
Similar presentations
Magnetic Resonance Imaging
Advertisements

MRI Phillip W Patton, Ph.D..
Magnetic Resonance Imaging
PHYSICS OF MAGNETIC RESONANCE
Magnetic Resonance Imaging - MRI
MR TRACKING METHODS Dr. Dan Gamliel, Dept. of Medical Physics,
Fund BioImag : Introduction to Magnetic Resonance 1.What are the components of an MR scanner ? 2.What is the basis of the MR signal ? 3.How is.
Fysisk institutt - Rikshospitalet 1 Source: Courtesy of Warner Bros Science or black magic? Chap.12 (3) Medical imaging systems: MRI.
Magnetic Resonance Imaging
Magnetic Resonance Imaging
MRI. Magnetic Resonance 1.Principle first observed in Used for spectroscopy and imaging 3.Imaging techniques are a form of tomography, where slices.
ELEG 479 Lecture #9 Magnetic Resonance (MR) Imaging
ECE 501 Introduction to BME
Medical Imaging Mohammad Dawood Department of Computer Science University of Münster Germany.
FMRI: Biological Basis and Experiment Design Lecture 5: non-BOLD MRI Equilibrium and excitation Relaxation rates Image contrast –TE –TR.
Basics of Magnetic Resonance Imaging
Computed Tomography. Introduced in 70’s Principle: Internal structures of an object can be reconstructed from multiple projections of the object.
Introduction to Medical Imaging
Magnetic Resonance Imaging
Magnetic Resonance Imaging Basic principles of MRI This lecture was taken from “Simply Physics” Click here to link to this site.
Introduction of Medical Imaging Chun Yuan. Organization of the Course 8 Lectures (1.5 hours per lecture) – Introduction of medical imaging and MRI – Basic.
Magnetic Resonance Imaging
Medical Imaging Systems: MRI Image Formation
Ultrasound Physics Sound is a mechanical, longitudinal wave that travels in a straight line Sound requires a medium through which to travel Ultrasound.
Physics of Magnetic Resonance Chapter 12
대구가톨릭대학병원 영상의학과 이 영 환 M M R R Basic Physics. MR Signal T1-, T2-weighted TR, TE MR Signal T1-, T2-weighted TR, TE.
Medical Physics Physics 421 Course Description: Medical Physics is a course with two main parts:  Physics of the body  Physics of Diagnostic and Therapeutic.
Principles of Magnetic Resonance
3/13/2009IB Physics HL 21 Ultrasound Medical Imaging Physics – IB Objectives I.2.7Describe the principles of the generation and the detection of ultrasound.
MRI Physics: Just the Basics
Doppler echocardiography & Magnetic Resonance Imaging.
Prof. Dr. Moustafa. M. Mohamed Dr. Eng. Safa Ahmed El-Askary
BE 581 Intro to MRI.
Medical Imaging Systems: MRI Image Formation
Chapter 4 Mark D. Herbst, M.D., Ph.D.. Magnetization MRI depends on magnetization of tissues Temporary magnetization occurs when the hydrogen nuclei are.
Basic Physical Principles of MRI
Basic of Magnetic Resonance Imaging Seong-Gi Kim Paul C. Lauterbur Chair in Imaging Research Professor of Radiology, Neurobiology and Bioengineering University.
September, 2003BME 1450 Introduction to NMR 1 Nuclear Magnetic Resonance (NMR) is a phenomenon discovered about 60 years ago.
fMRI Methods Lecture2 – MRI Physics
MR Signal Generation FMRI Undergraduate Course (PSY 181F)
Physics of Radiology Lior Copel, M.D. Assaf Harofeh Medical Center, Zerifin Sackler School of Medicine, Tel-Aviv University.
Nuclear Magnetic Resonance I Magnetization properties Generation and detection of signals.
1 Introduction to Magnetic Resonance Imaging درس مقدمه ای بر فیزیک پزشکی Sahand University of Technology Faculty of Electrical Engineering M. Shamsi.
Magnetic Resonance Imaging
MRI. Vector Review x y z Vector Review (2) The Dot Product The Cross Product (a scalar) (a vector) (a scalar)
University of Wisconsin Diagnostic Imaging Research.
BME1450 Intro to MRI February 2002 The Basics The Details – Physics The Details – Imaging.
Protons (hydrogen nuclei act like little magnets) MRI Collective Magnetic Moment of Protons (M 0 ) Each pixel is a glass of protons B 0 = 3T (not to scale)
Fund BioImag : Relaxation of nuclear magnetization 1.How is the MR signal detected ? 2.What is the quantum-mechanical equivalent of the rotating.
Magnetic Resonance Imaging (MRI). The Components: A magnet which produces a very powerful uniform magnetic field. A magnet which produces a very powerful.
Introducing cross- sectional imaging Dr.Ahmed S. Tawfeek FIBMS(Rad.)
RT 4912 Review (C) Rex T. Christensen MHA RT (R) (MR) (CT) (ARRT) CIIP.
Magnetic Resonance Imaging Glenn Pierce, King’s College London, Department of Physics Introduction Edward Purcell and Felix Bloch were both awarded the.
Spinning Nucleus Produces Magnetic Moment
MRI Magnetic Resonance Imaging. Definition A non-ionizing technique with full three dimensional capabilities, excellent soft-tissue contrast, and high.
Lecture 1: Magnetic Resonance
 This depends on a property of nuclei called spin.  Gyroscope: Principle: As long as its disc remains spinning rapidly the direction of the spin axis.
MAGNETIC RESONANCE IMAGING by PRADEEP V.EPAKAYAL. Mem.no L.
Medical Imaging. X-ray Radiography 2-D projection image created from difference in x-ray absorption rates between tissues 2-D projection image created.
Introduction to medical imaging
Physics of Magnetic Resonance Imaging
Medical Imaging Imagining Modalities.
Spatial Encoding: Sub mm from meter sized RF
Medical Physics Physics 421 Course Description:
Basic MRI I Chapter 3 Notes.
Introduction to MR Robert Frost
(4)ELECTRONIC SUPPORT SYSTEM
T2 Relaxation Time T2 relaxation time is defined as the time needed to dephase up to 37% of the original value. T2 relaxation refers to the progressive.
Introduction to MR Robert Frost
Presentation transcript:

Introduction (2/2) – Comparison of Modalities Review: Modalities: X-ray: Measures line integrals of attenuation coefficient CT: Builds images tomographically; i.e. using a set of projections Nuclear: Radioactive isotope attached to metabolic marker Strength is functional imaging, as opposed to anatomical Ultrasound: Measures reflectivity in the body.

Ultrasound Ultrasound uses the transmission and reflection of acoustic energy.  prenatal ultrasound image  clinical ultrasound system

Ultrasound A pulse is propagated and its reflection is received, both by the transducer. Key assumption: - Sound waves have a nearly constant velocity of ~1500 m/s in H 2 O. - Sound wave velocity in H 2 O is similar to that in soft tissue. Thus, echo time maps to depth.

Ultrasound: Resolution and Transmission Frequency Tradeoff between resolution and attenuation - ↑ higher frequency ↓ shorter wavelength ↑ higher attenuation Power loss: Typical Ultrasound Frequencies: Deep Body 1.5 to 3.0 MHz Superficial Structures 5.0 to 10.0 MHz e.g. 15 cm depth, 2 MHz, 60 dB round trip Why not use a very strong pulse? Ultrasound at high energy can be used to ablate (kill) tissue. Cavitation (bubble formation) Temperature increase is limited to 1º C for safety.

Major MRI Scanner Vendors Siemens Sonata General Electric CV/i Philips Intera CV

MRI Uses Three Magnetic Fields Static High Field (B 0 ) (Chapter 12, Prince) –Creates or polarizes signal –1000 Gauss to 100,000 Gauss Earth’s field is 0.5 G Radiofrequency Field (B 1 ) (Chapter 12, Prince) –Excites or perturbs signal into a measurable form –On the order of O.1 G but in resonance with MR signal –RF coils also measure MR signal –Excited or perturbed signal returns to equilibrium Important contrast mechanism Gradient Fields ( Chapter 13, Prince) –1-4 G/cm –Used to image: determine spatial position of MR signal

Magnetic Dipole Representation Vector Representation Nuclear Magnetic Dipole Moment

Nuclear Magnetic Dipole Moment : Spinning Charge P P P N N P P HydrogenHeliumHelium-3 N

No Magnetic Field Random Orientation = No Net Magnetization

Classical Physics: Top analogy Spins in a magnetic field: analogous to a spinning top in a gravitational field. gravity Top precesses about the force caused by gravity Dipoles (or spins) will precess about the static magnetic field Axis of top

Static Magnetic Field (B 0 ) Bore (55 – 60 cm) Shim (B 0 uniformity) Magnetic field (B 0 ) Body RF (transmit/receive) Gradients

Reference Frame Magnetic field (B 0 ) aligned with z (longitudinal axis and long axis of body) y x z

Main Magnetic Field B0B0B0B0

Effects of Strong Magnetic Fields

Magnetic Resonance Imaging: Static Field There are 3 magnetic fields of interest in MRI. The first is the static field B o. 1) polarizes the sample: 2) creates the resonant frequency: γ is constant for each nucleus: density of 1 H ω = γB

Dipole Moments from Entire Sample B0B0 Non-Random Orientation 7 up 6 down

Net Magnetization Sum Dipole Moments -> Bulk Magnetization The magnetic dipole moments can be summed to determine the net or “bulk” magnetization, termed the vector M. B0B0 M x y z x y z

Static Magnetic Field (B 0 ) Bore (55 – 60 cm) Shim (B 0 uniformity) Magnetic field (B 0 ) Body RF (transmit/receive) Gradients

Second Magnetic Field : RF Field B1B1B1B1 An RF coil around the patient transmits a pulse of power at the resonant frequency ω to create a B field orthogonal to B o. This second magnetic field is termed the B 1 field. B 1 field “excites” nuclei. Excited nuclei precess at ω(x,y,z) = γB o (x,y,z)

Polarized signal is all well and good, but what can we do with it? We will now see how we can create a detectable signal. To excite nuclei, tip them away from B 0 field by applying a small rotating B field in the x-y plane (transverse plane). We create the rotating B field by running a RF electrical signal through a coil. By tuning the RF field to the Larmor frequency, a small B field (~0.1 G) can create a significant torque on the magnetization. B 1 Radiofrequency Field Diagram: Nishimura, Principles of MRI

Exciting the Magnetization Vector z B 1 tips magnetization towards the transverse plane. Strength and duration of B 1 can be set for any degree rotation. Here a 90 degree rotation leaves M precessing entirely in the xy (transverse) plane. Laboratory Reference Frame

Tip Bulk Magnetization x' y' z' M B 1 Rotating Reference Frame Imagine you are rotating at Larmor frequency in transverse plane

Tip Bulk Magnetization x' y' z' B 1 Rotating Reference Frame

Tip Bulk Magnetization x' y' z' B 1 Rotating Reference Frame

Tip Bulk Magnetization x' y' z' B 1 Rotating Reference Frame

Transmit Coils Preamp DemodulateA/D RF Coil

Static Magnetic Field (B 0 ) Bore (55 – 60 cm) Shim (B 0 uniformity) Magnetic field (B 0 ) Body RF (transmit/receive) Gradients

Gradient Coils Fig. Nishimura, MRI Principles

Spin Encoding

Magnetic Resonance The spatial location is encoded by using gradient field coils around the patient. (3 rd magnetic field) Running current through these coils changes the magnitude of the magnetic field in space and thus the resonant frequency of protons throughout the body. Spatial positions is thus encoded as a frequency. The excited photons return to equilibrium ( relax) at different rates. By altering the timing of our measurements, we can create contrast. Multiparametric excitation – T 1, T 2

Brain Glioma

Sagittal Carotid Non-contrast-enhanced MRI Coronal

Contrast-enhanced Abdominal Imaging

Time-resolved Abdominal Imaging

Contrast-enhanced MR Cardiac Imaging

Fat Coronal Knee ImageWater Coronal Knee Image

Comparison of modalities Why do we need multiple modalities? Each modality measures the interaction between energy and biological tissue. - Provides a measurement of physical properties of tissue. - Tissues similar in two physical properties may differ in a third. Note: - Each modality must relate the physical property it measures to normal or abnormal tissue function if possible. - However, anatomical information and knowledge of a large patient base may be enough. - i.e. A shadow on lung or chest X-rays is likely not good. Other considerations for multiple modalities include: - cost- safety - portability/availability

Comparison of modalities: X-Ray Measures attenuation coefficient Safety: Uses ionizing radiation - risk is small, however, concern still present individual lesions per population risk > individual risk i.e. If exam indicated, it is in your interest to get exam Use: Principal imaging modality Used throughout body Distortion: X-Ray transmission is not distorted.

Comparison of modalities: Ultrasound Measures acoustic reflectivity Safety: Appears completely safe Use: Used where there is a complete soft tissue and/or fluid path Severe distortions at air or bone interface Distortion: Reflection: Variations in c (speed) affect depth estimate Diffraction: λ ≈ desired resolution (~.5 mm)

Comparison of modalities: Magnetic Resonance (MR) Multiparametric M(x,y,z) proportional to ρ(x,y,z) and T 1, T 2. (the relaxation time constants) Velocity sensitive Safety: Appears safe Static field - No problems - Some induced phosphenes Higher levels - Nerve stimulation RF heating: body temperature rise < 1˚C - guideline Use: Distortion: Some RF penetration effects - intensity distortion

Clinical Applications - Table ChestAbdomenHead X-Ray/ CT + widely used + CT - excellent – needs contrast + CT - excellent + X-ray - is good for bone – CT - bleeding, trauma Ultrasound– no, except for + heart + excellent – problems with gas – poor Nuclear+ extensive use in heart Merge w/ CT+ PET MR+ growing cardiac applications + minor role+ standard

Clinical Applications – Table continued… CardiovascularSkeletal / Muscular X-Ray/ CT + X-ray – Excellent, with catheter-injected contrast + strong for skeletal system Ultrasound+ real-time + non-invasive + cheap – but, poorer images – not used + Research in elastography Nuclear+ functional information on perfusion + functional - bone marrow MR+ getting better High resolution Myocardium viability + excellent

Economics of modalities: Ultrasound: ~ $100K – $250K CT: $400K – $1.5 million (helical scanner) MR: $350K (knee) million (siting) Service: Annual costs Hospital must keep uptime Staff: Scans performed by technologists Hospital Income: Competitive issues Significant investment and return