High Temperature Cooling of Cryoplants and RF Systems at the European Spallation Source 2 nd Workshop Energy for Sustainable Science at Research Infrastructures.

Slides:



Advertisements
Similar presentations
11/27/2007ILC Power and Cooling VM Workshop Mike Neubauer 1 RF Power and Cooling Requirements Overview from “Main Linac Power and Cooling Information”
Advertisements

Thomas Parker, Head of Energy Division Responsible Renewable Recyclable Thomas Parker October 2013.
ESS Cooling and Heat Recovery system Thomas Hjern
ESS Cryogenic System Design
Roger Ruber, Volker Ziemann, Gergana Hamberg Uppsala University
DESIGN OF A HIGH POWER TEST STAND FOR ESS SPOKE CAVITIES
ESS Linac WP8 Radio Frequency Systems and Test Facilities ESS TAC Lund, 8 July 2010 Roger Ruber (Uppsala University) for the ESS Linac RF Team.
Renewable Technologies Available in Ireland Paul Kane.
Energy management at FERMILAB: strategy on energy management, efficiency, sustainability Stephen Krstulovich, energy manager.
ESS Cryogenic System Process Design Philipp Arnold Section Leader Cryogenics CEC – ICMC 2015 June 29, 2015.
ESS | Power System | | Frithiof Jensen ESS Power System Ion Source, Front-end.
Linac Front-End R&D --- Systems Integration and Meson Lab Setup
Adsorption Refrigeration System. INTRODUCTION  Adsorption refrigeration system uses adsorbent beds to adsorb and desorb a refrigerant to obtain cooling.
Discussion on Studies at Test Stands Roger Ruber Uppsala University.
Large-capacity Helium refrigeration : from state-of-the-art towards FCC reference solutions Francois Millet – March 2015.
Introduction and Charge to the Review of ESS Target building and Instrument Hall design requirements Roland Garoby November 2014, Lund
Test Stands Roger Ruber Uppsala University ESS TAC4 16 Feb
2nd Workshop on Energy for Sustainable Science at Research Infrastructures Report on Parallel Session A4: Energy Quality and Operation __________ Roberto.
RF Distribution Alternatives R.A.Yogi & FREIA group Uppsala University.
Cryogenik waste heat utilization for DESY and European XFEL 2nd Workshop on Energy for Sustainable Science at Research Infrastructurs Jens-Peter Jensen,
Lecture Objectives: Specify Exam Time Finish with HVAC systems –HW3 Introduce Projects 1 & 2 –eQUEST –other options.
Accelerators for ADS March 2014 CERN Approach for a reliable cryogenic system T. Junquera (ACS) *Work supported by the EU, FP7 MAX contract number.
Thomas Parker Head of Energy Division Sustainable Accelerators.
F Project X Overview Dave McGinnis October 12, 2007.
The ESS Cryogenics System J. G. Weisend II, P. Arnold, J Fydrych, W. Hees, J. Jurns, A. Lundmark, X. T. Su, X.L. Wang June 2015.
CLIC Implementation Studies Ph. Lebrun & J. Osborne CERN CLIC Collaboration Meeting addressing the Work Packages CERN, 3-4 November 2011.
RF Development for ESS Roger Ruber and Volker Ziemann Uppsala Universitet 4 Dec Dec-20091RR+VZ: ESS RF Development.
Anders Sunesson RF Group ESS Accelerator Division
1 Towards A Low Carbon Era Ms Anissa Wong, JP Permanent Secretary for the Environment The British Chamber of Commerce in Hong Kong Construction Industry.
HWDB: Operations at the Spallation Neutron Source Workshop on Accelerator Operations August 6-10, 2012 Glen D. Johns Accelerator Operations Manager.
ESS RF System Design Stephen Molloy RF Group ESS Accelerator Division SLHiPP2 4-May-2012.
Aug 23, 2006 Half Current Option: Impact on Linac Cost Chris Adolphsen With input from Mike Neubauer, Chris Nantista and Tom Peterson.
S. Claudet - 31st May 2007Power refrigeration for LHC Power refrigeration at 4.5K & 1.8K for the LHC S. Claudet, CERN AT-ACR.
Preliminary Functional Analysis of ESS Superconducting Radio-Frequency Linac C. Darve, N. Elias, J. Fydrych, D. Piso European Spallation Source ESS AB,
Energy Management and Planning MSJ0210 Energy generation 2 Eduard Latõšov.
ESS Linac Modifications for ESSnuSB Dave McGinnis Chief Engineer / Accelerator Division August 27, 2014.
Jan Low Energy 10 Hz Operation in DRFS (Fukuda) (Fukuda) 1 Low Energy 10Hz Operation in DRFS S. Fukuda KEK.
ESS Linac WP8 Radio Frequency Systems and Test Facilities ESS/SPL Collaboration Meeting Lund, 29 June 2010 Roger Ruber (Uppsala University) for the ESS.
DISTRICT HEATING District heating is an infrastructure which allows heat generated in a centralized location to be distributed to residential homes and.
J. G. Weisend II for the ESS Team Energy Efficiency & Recovery at ESS.
PXIE Cryogenics Concept Arkadiy Klebaner Session 5 / WG1 (CW Linac and PXIE) October 26 th, 2011.
650 MHz Solid State RF Power development at RRCAT
1 ESS Warm End Linac Cooling Water 5-6 May 2014 John Jurns.
Project X Workshop - Cryogenics1 Project X CRYOGENICS Arkadiy Klebaner.
Cooling Water and Heat Recovery system Thomas Hjern Harald Bäck Design Leader Process systems Conventional Facilities Accelerator Review November 3-4,
ESS Cooling System - Interface with DTL 1 John Jurns Cooling System Engineer.
CSNS cryogenic system Institute of High Energy Physics Guoping Wang June 21, 2016.
Heat Plan Denmark Low Carbon Urban Heating Anders Dyrelund, market manager Rambøll Denmark.
ESS Cooling System - Interface with RFQ 1 John Jurns Cooling System Engineer.
ESS Linac Upgrade Dave McGinnis Chief Engineer / Accelerator Division May 27, 2014.
Chapter Editor: John Weisend TDR Chapter 6 Cryogenic System, Vacuum System & Test Stands.
FCC Infrastructure & Operation Update on the cryogenics study Laurent Tavian CERN, TE-CRG 28 October 2015.
The ESS Target Station Eric Pitcher Head of Target Division February 19, 2016.
ESS LLRF and Beam Interaction
RF cell Anders Sunesson RF group leader
Cryomodule test stand at ESS site
Innovative He cycle Francois Millet.
Uppsala Commitment to ESS and FREIA Planning
Overview and System Design for ESS LLRF Systems
Session Ic “Energy efficiency/recovery/optimization”
ESS RF Development at Uppsala University
BriXS – MariX WG 8,9 LASA December 13, 2017.
Optimum cryomodule length at the ESS
CEPC RF Power Sources System
Mathew C. Wright January 26, 2009
Cryomodules Challenges for PERLE
RF systems introduction
RF introduction Anders Sunesson RF group leader
Roger Ruber for the FREIA team 11 June 2013, Uppsala
Project Support Meeting January 9, 2019
Presentation transcript:

High Temperature Cooling of Cryoplants and RF Systems at the European Spallation Source 2 nd Workshop Energy for Sustainable Science at Research Infrastructures CERN, Geneva Switzerland October 23-25, John Jurns

ESS Overview Spallation Neutron Source Being built in southern Sweden 482.5m long, 5MW, proton linear accelerator at 2.5 GeV, 5 mA 2.86 ms pulses, ≈14Hz (60 ms period) Solid tungsten metal target 22 neutron instruments To support a 5000-strong user community 450 staff First protons in 2019 Full design specifications 2025 Photo - Henning Larson Architects

Energy Philosophy and Heat Recovery Strategy ESS has committed to an energy management strategy* that minimizes cost, lowers environmental impact, and factors out variability in energy. The ESS energy management strategy is based on four pillars: Responsible – optimize energy efficiency and lower energy consumption to 270 GWh/yr from the original estimate of 310 GWh/yr Renewable – Invest in renewable energy production sufficient to cover ESS integrated annual electricity use Recyclable – Provide a cooling system that recycles waste heat to the city of Lund district heating system and/or other potential customers Reliable – Provide stable electricity and cooling supplies for ESS operations * ESS “Energy Policy”

Lund District Heat System Lund District Heat system will be source for ESS cooling, and customer for ESS recycled heat Lund population ~ 111,000 ~80% of population served by Lund district heat system LDH system description 300 km network 10,000 m 3 of water circulating 74% of heat from renewable & recycled sources Plan for towards zero carbon by ,087 GwH heat produced in 2012 Interface with ESS Supply temperature to ESS – 45 C Return temperature to LDH – 80 C ESS

Share of renewable fuels and recycled heat in the consolidated district heating production Fuel mix for district heat input fuel energy bio-oil heat pumps (geothermal water heat from waste water, heat from the cooling output, heat from the aquifer) Natural gas electricity to heat pumps waste heat nordic sugar recycled wood pellet Bought heating wood chips and straw-based woodchips briquette biogas oil electricity (electric boiler) Direct emissions per unit of energy district heating Renewable fuels & recycled heat 17% Other 83% Renewable fuels & recycled heat 44% Other 56% Renewable fuels & recycled heat 70% Other 30% Renewable fuels & recycled heat 74% Other 26% Lunds Energi Koncernen Hållbarhetsredovisning 2012 Lunds Energi progress towards zero carbon

Other potential users of recycled heat Unfortunately, not all heat recovered from ESS is at warm enough to send directly to LDH Options to use this heat: Use heat pumps to increase temperature Find other uses for low grade heat ESS is investigating use of low grade heat in a hybrid cooling chain to extract heat for things like the production of food, fodder and bio-fuels More details are outlined in other ESS presentations. Proposal for a Sustainable Research Facility ESS Energy Concept Final Report January 2013

Cooling System Overview ESS will ultimately consume over 40 MW of electrical power, only a small portion of which ends up generating neutrons. Only 5 MW goes into the beam - most of the energy consumed is turned into waste heat. ESS plans to recycle waste heat to the Lund district heating network, ultimately supplying 20 percent of its total annual requirement. Cooling system requirements The cooling and heat recovery system of the ESS plant shall be designed to meet the following requirements: Provide reliable and efficient cooling of all parts of the ESS site that requires water cooling Transfer as much heat as possible from the cooling system to the city of Lund district heating system and/or other external waste heat recovery systems

ESS cooling system architecture overview Cooling system - Central Utilities Building 3 cooling water supply temperatures (5/30/50 deg C) 45 deg C supply from Lund district heat system Heat pumps to raise temperature of CW-L & CW-M return

ESS cooling system architecture (continued) The scope of the cooling system design is primarily to manage the flow of heat in the technical infrastructure (i.e. – the “machine”). Cooling is accomplished primarily with water. Systems in scope include: Accelerator – klystron gallery and linac tunnel Target – interface at target internal cooling systems boundary Cryoplants – compressor and helium cooling NSS – cooling as required for instruments and support equipment Test stand – cooling for test stand klystrons, power supplies, etc.

ESS cooling distribution Target building LINAC SC cavities cooling RFQ/DTL cooling substation Ion source cooling Central utilities building Target cooling substation Cryo cooling Instrument cooling Cryoplants Instruments Lund District Heating System

Warm end linac Cold end linac Cryoplant & test stand Target NSS Internal DH External customers Back up cooling Lund District Heat Klystron gallery Tunnel KG low beta KG high beta Tunnel Cryo linac Cryo target Cryo NSS Test stand CUB Collector Circulato r Load Body Modulator Tetrode collector Tetrode filament Amplifier Circulato r Load Collector Circulato r Load Body Modulator Collector Circulato r Load Body Modulator Ion source MEBT Couplers Hi accuracy cooling RFQ DTL Couplers Target Intermed He Intermed H 2 O Direct H 2 O Instruments Labs HVAC HVAC linac Tap water Air compr. HEBT Areas LLRF racks RFQ/D TL Spokes Collector Circulato r Load Body Modulator LLRF racks Cooling water block flow

Waste heat summary Our current estimate of cooling loads and cooling water supply temperature is shown in the table below. System Low temp. 5 C (MW) Med temp. 30 C (MW) Hi temp. 50 C (MW)Total Linear accelerator4,22,38,414,9 Target Station7,5-- Instruments1,6-- Cryogenic systems1,45,5-6,9 Miscellaneous00,5- Buildings-1,8 Total14,76,58,429,6 Heat pumps to raise temp.4,26,0-10,2 ESS total cooling requirements by system & supply temperature ~71% of all heat comes from RF equipment and Cryoplants

Waste heat summary Our current estimate of heat available from the return flows for each of the temperature ranges is shown in the table below. Return flows(MW) From RF, cryo (MW) Low (25 C)10,11,3 Med (40 C)5,03,0 Intermed. (65 C)1,4 High (85 C)13,1 High (heat pumps) (85 C)10,2 Total39,821,8 ESS total heat returned by temperature range 100% of high grade heat comes from RF equipment and Cryoplants

Plans to optimize heat recovery Overall design philosophy Use highest reasonable temperature for cooling equipment Maintain outlet temperature, control flow Load TT

Klystron gallery equipment Klystrons Collector – CW-High supply Body – CW-Medium supply Circulators – CW-High supply Loads – CW-High supply Modulators – CW-Low supply LLRF – CW-Low supply ESS CDR reference Typical cooling Medium β RF Note – 2 modulators per klystron Plans to optimize heat recovery kW

Klystron gallery equipment ORNL/SNS site visit photos August 2012 KlystronCirculatorLoadModulator Total RF equipment cooling loads, supply & return temperatures

Plans to optimize heat recovery ESS cryoplants Cooling for the cryomodules (2 K, 4.5 – 8 K and 40 K) Cooling for the Target LH 2 Moderator (16 K) Liquid Helium for the Neutron Instruments Cooling for the cryomodule test stands (2 K, 4.5 – 8 K and 40 K) This is accomplished via 3 separate cryoplants Cryoplant equipment requiring cooling water Oil coolers Helium coolers Motor cooling

Cryoplant Equipment Cryoplant water cooling requirements Will likely use a combination cold & warm compression Turn down capacity & ability to recover from trips quickly are key issues Turning down cryoplants will result in lower cooling requirements CryoplantMinimum cooling required (kW) Maximum cooling required (kW) Linac Target NSS & Test Stand400 Total

Cryoplant equipment (typical) Helium coolers low temp supply Oil coolers, motor medium temp supply Consider control loop to regulate return temperature for varying cryoplant operation

Klystron operating temperature issues Can we collect heat from klystrons at a high temperature? Collector temperature rise typically C Maximum CW outlet temperature must remain below C Depending on klystron operating mode, cooling flow rate can vary 2X Manufacturers typically specify a flow rate for cooling Literature review* indicates that failures do not appear to originate primarily at collector, but at the other end of the klystron. Note the electron gun portion of klystron is cooled at a much lower temperature (~40 C). *Argonne Nat’l Lab 2008 – “The Linac Klystrons Aging & Associated Problems” SLAC klystrons 1996 – “Advanced RF Power Sources for Linacs” Based on the above: Reasonable plan to cool the klystron collectors at C Arrange several klystrons in series to maximize outlet temperature Confirm plan to vary CW flow with klystron manufacturers

Cryoplant operating temperature issues Can we collect heat from cryoplants at a high temperature? Oil cooler temperature should not exceed ~90 C Cool helium from CW-Low supply to optimize cryoplant performance Cryoplant operation at reduced capacity may be a candidate for flow control of cooling water to maximize CW return temperature Standard shell & tube heat exchangers not the most efficient – consider using plate heat exchangers instead to increase CW return temperature Based on the above: Maximize CW return temperature Confirm high temperature CW return with manufacturers See if PHX are a possibility

Risks and challenges Risks & Challenges Reliability – assess impact of cooling temperature on equipment performance Lower operating temperatures – increased equipment reliability Balance equipment technical requirements with ESS energy goals Higher operating temperatures – increased heat recovery Minimize cost of recovering heat More equipment operating at higher temperatures means less energy required for heat pumps Design system to effectively recover heat under all operating regimes

Summary ESS has committed to an energy policy that will influence system design Energy recovery comes at a cost, but also provides benefits Energy management innovation in large research facilities Better stewards of our environment Income! Recovered energy has cash value Innovation will require close cooperation with system designers, equipment manufacturers, and customers for our recycled energy Concentrate on areas of greatest return for energy recovery: RF systems Cryoplants Stay tuned!