Title Month Year John Richmond

Slides:



Advertisements
Similar presentations
DAQMASTER Features and Benefits
Advertisements

Wireless Controllers. Building block for remote control & alarming Functions Local control Measurement SMS alarming Remote control via SMS Data transmission.
EECE499 Computers and Nuclear Energy Electrical and Computer Eng Howard University Dr. Charles Kim Fall 2013 Webpage:
NERC Lessons Learned Summary December NERC lessons learned published in December 2014 Three NERC lessons learned (LL) were published in December.
Vendor Briefing May 26, 2006 AMI Overview & Communications TCM.
1 BROOKHAVEN SCIENCE ASSOCIATES NSLS-II Shielding Workshop S. Buda Personnel Protective Systems March 27, 2007.
CIT 470: Advanced Network and System Administration
Spencer Murray, Sr. Telecom Eng. Distribution Automation.
All content in this presentation is protected – © 2008 American Power Conversion Corporation Rael Haiboullin System Engineer Change Manager.
Team Dec13_11: Cole Hoven Jared Pixley Derek Reiser Rick Sutton Adviser/Client: Prof. Manimaran Govindarasu Graduate Assistant: Aditya Ashok PowerCyber.
EUT 1040 Lecture 10: Programmable Logic Controllers.
PLC Based Residential Alarm System John Hiddema University of Idaho - ECE Spring 2012.
Smart Grid Projects Andrew Bui.
Optimizing SCADA Network Communications: An Overview of Metropolitan Wide SCADA Communications Options by John McCain and Russ Straayer.
Network Management Overview IACT 918 July 2004 Gene Awyzio SITACS University of Wollongong.
An Introduction to SCADA Fundamentals and Implementation Supervisory Control And Data Acquisition.
SCADA SYSTEM CLASSIFICATION
The Need for an Integrated View of Water Quality Modeling and Monitoring Bruce Kiselica USEPA, Region 2 Second Workshop on Advanced Technologies in Real.
Wireless Remote Control Derail System CSX Atlanta, GA Track and Derail Graphic layout CSX Atlanta, GA.
DAKNET Presented By: rreema.
 A system consisting of a number of remote terminal units (or RTUs) collecting field data connected back to a master station via a communications system.
Secure Systems Research Group - FAU 1 SCADA Software Architecture Meha Garg Dept. of Computer Science and Engineering Florida Atlantic University Boca.
 Wireless, Web-Based Monitoring System  Alarm/Event Notifications by Text Message and or  VPN Connection for Fast Response to Alarms and Events.
Data Centers and IP PBXs LAN Structures Private Clouds IP PBX Architecture IP PBX Hosting.
PM-RS / March Industrial CMC. PM-RS / March Industrial CMC III Where did it start? Where is it headed? Rittal supplies infrastructure for.
Distributed Control Systems Emad Ali Chemical Engineering Department King SAUD University.
Network Topologies.
Smart Grid Research Consortium Conference Communications: Technologies Systems Future Trends Dr Rick Russell.
An Introduction to SCADA Fundamentals and Implementation
SCADA and Telemetry Presented By:.
EC4019PA Intrusion & Access Control Technology (IACT) Chapter 4- CAMS Prepared by Sandy Tay.
Networking All talk - Selective listen Network up to 15 active nodes + 17 passive nodes Nexus/Discovery panels, network repeaters, R3 19” racks, Alarm.
IRRInet & ICC System Concept
REMOTE SITE MANAGEMENT SOLUTION. AGENDA 2  About KoçSistem  Current Situation in Base Stations  Remote Site Management System: Sitelink  Sitelink.
“web to wireless” Technology. A LEADER IN web to wireless ASSET MANAGEMENT ROM Communications Inc.
Traffic Enforcement And Management System Malam-Team is Israel's largest systems integration organization, One of the most exciting solutions offered by.
© Ahmed El-Rabbany Ahmed El-Rabbany Geomatics Engineering Program Department of Civil Engineering RYERSON POLYTECHNIC UNIVERSITY Toronto, Ontario INTEGRATED.
1 1 Local vs. remote intelligence A quick look at two different architecture management systems Copyright Nitrosoft 2010.
Abstract Other Resources Financial Resources Project Schedule Personnel Efforts Item DescriptionCost STK300 Microcontrollerdonated (Kanda) GM28 Cellular.
NCSX NCSX Preliminary Design Review ‒ October 7-9, 2003 G. Oliaro 1 G. Oliaro - WBS 5 Central Instrumentation/Data Acquisition and Controls Princeton Plasma.
Prepared By :.  Introduction  Techniques Used  Case Study  Advantages  Application  Conclusion OUTLINE.
A smart signalling system for Indian railways Smart signalling system – user’s view Full capacity realisation Flexibility of movements Easy to operate.
1 Critical Mission Support Through Energy Security Susan Van Scoyoc Concurrent Technologies Corporation 16 August 2012 Energy Huntsville Meeting Huntsville,
A Review by Raghu Rangan WPI CS525 September 19, 2012 An Early Warning System Based on Reputation for Energy Control Systems.
Product range/ALPHA-E-0001-tri-20/04/03 ALPHA Micro Controllers A single multi-functional unit instead of multiple components ALPHA / ALPHA XL Products/ALPHA.
Unit 5 CONTROL CENTERS AND POWER SYSTEM SECURITY.
Topics of presentation
AtoNs experiences in implementation in Romania Vukovar, December, 2012.
Welcome to OmniMetrix. Who We Are OmniMetrix ® is the leader and pioneer in machine to machine (M2M) wireless remote monitoring, control and diagnostics.
Network Components By Kagan Strayer. Network Components This presentation will cover various network components and their functions. The components that.
Wireless Network Management SANDEEP. Network Management Network management is a service that employs a variety of tools, applications, and devices to.
16 February 2016 Connected Worker. © 2015 by Honeywell International Inc. All rights reserved. Connected Worker 1 Real Time Gas Detection, Real Time Telematics.
SEMINAR ON P.L.C. SUBMITTED BY HRIDAY MUKHERJEE AMIT DEBNATH SOMNATH SHIL
Wired and Wireless network management 1. outline 2 Wireless applications Wireless LAN Wireless LAN transmission medium WLAN modes WLAN design consideration.
CompactLogix Controllers Portfolio
PREFERRED UTILITIES MFG CORP South St. Danbury CT T: (203) F: (203) www. PREFERRED-MFG.com.
SCADA Supervisory Control And Data Acquisition Pantech Solutions Here is the key to learn more.
Artificial Intelligence In Power System Author Doshi Pratik H.Darakh Bharat P.
Lessons Learned Implementing an IEC based Microgrid Power-Management System October 12, 2015 Presented by: Jared Mraz, P.E.
Nexbase Invites You To Our Special Products
What is ASEMR /ASKUE/ and the Need for Its Implementation
CANAL NETWORK CONTROL AJAY K BASU
Smart Ethernet I/O P2P and GCL Introduction
Programmable Logic Controllers (PLCs) An Overview.
Who We Are BlueI provides a holistic management system for water quality By providing a total water analytics solutions along side with state of the art.
Water & Irrigation Control systems
Substation Automation System
Instrumentation and control
Process Dynamics and Control:
Presentation transcript:

Title Month Year John Richmond Upper St. Johns River Basin SCADA System John Richmond

Introduction The SJRWMD operated its Water Control Structures manually within the region. During previous hurricane seasons and other threatening conditions, manual operations put field staff at risk for necessary gate changes. The District was looking to eliminate this safety issue by establishing a secure and reliable remote control and monitoring system, to operate 18 gates on 9 flood control structures The District initiated the SCADA (Supervisory Control and Data Acquisition) project.

Objectives and Requirements Real-time monitoring and controlling of 18 gate structures with Motorola Remote Terminal Units (RTUs). Monitoring requirements - stage levels (head/tail); gates positions; power system; door Controlling requirements - move the gates to a desired height; Generator; Power Transfer Switch Multiple Remote control locations - Operable via laptop computer from ANYWHERE Availability - SJRWMD required redundant RF links; prime link is the Data Radio VHF dedicated channel and secondary link uses the cellular public network, based on EDGE technology.

Objectives and Requirements (Cont.) Capability of operation under conditions of duress (Storm events, subsystems failures). Availability of contingency operation plans. Reliability - Using proven, tested technology with high-reliability products. Safety - Using a secure, trusted system with high level of security, avoiding false information, controls, and thwarting unauthorized usage. Considerations for future expansion. Additions of future gates structures and/or additional items for monitoring and control

Challenges Site Integration - The gate structures were installed more than 30 years ago by the U.S. Corps of Army Engineers. Thus, engineering documentation was not updated; In fact, a majority of the sites were not documented, e.g. gate logic control drawings. In addition, some of the electrical components were fatigued. Civil Work - The project required extensive infrastructure development. Communication - RF links a challenge due to the distances between the sites and the control centers. Geographical Spread - The sites were both physically isolated and quite distant from one another. Extensive travel and a major degree of onsite resourcefulness would be needed in order to solve unexpected tribulations.

Geographical Coverage

Geographical Coverage North Area South Area

Gate Structures S-96B & 96C

Gates Structure S-96D and S-3

Gate Structure S-164

System Architecture

SCADA Software and Communications The RTU communicates through DataRadio Integra VHF radio to the Gateway at Palm Bay Service Center. The RTUs or the Gateway switch automatically to a redundant cellular data link (EDGE) in case the main VHF link is not accessible. It is also possible to access the RTUs directly via the cellular data link virtually from any location. This mode of operation is very basic, and is intended for manual, basic operation of the system using the Motorola Toolbox Basic software. The VTScada gathers and stores the data from RTUs. The software includes many visual capabilities for comprehensive real-time and historical data viewing. Additionally, the software includes an alarm managers, security manager, and data exporting.

AC CBs and Surge Protection Remote Terminal Unit AC CBs and Surge Protection DataRadio VHF Modem Cellular EDGE Modem Power Supply And Charger DC CBs and Distribution Local/Remote Switch Digital Interpose Relays Motorola MOSCAD Analog Input Interface

Normal Mode Emergency Mode RTU Operations The RTU application continuously monitors the local conditions via the wired I/O. Whenever data items (status, alarm, analog measurements) changes are detected, the MOSCAD RTU transmits a short message containing only the new data to the Central Computer, with VTScada. The RTU also stores a history of events. The data is stored in case of communications failure and troubleshooting. Emergency Mode The system is designed for mission-critical operations during emergency conditions (weather, communication failure, power failure, etc). Contingencies are built into every part of the system. This mode of operation is independent of any system communication and/or availability of the central computer system.

Work in Progress

Work in Progress (Cont.)

Work in Progress

Accomplishments and Future Expansions Implementation started on July 07 and the system was in production on December 07 SJRWMD and Star Controls worked as one team, which was essential to overcome challenges. Developments beyond the original SOW: Change in gate logic to improve operations Modifications of logic for emergency power to improve safety Change original design of S-3, including replacement of actuators to Smart type Smart use of Error Logging information from the RTUs and wireless devices to debug the system and improve performance Accomplished Availability, Resiliency and Flexibility goals Potential Expansion Add RTU to gate structure S-161 Water quality monitoring Use RTUs and SCADA for site access management Improve the emergency power system, i.e. generator, solar system Offer the use of RTUs to monitor consumption (i.e. quota) by the cities. Low cost solar powered gate structure