Most of the images recorded during conventional radiography are obtained with film/screen combination image receptors. Which in lessens the patient dose.

Slides:



Advertisements
Similar presentations
Analog Imaging II Intensifying Screens
Advertisements

Technical Aspects: the machine the image
Radiographic Film & Intensifying Screens
Chapter 11 Prime Factors.
Advanced Biomedical Imaging Lecture 4 Dr. Azza Helal A. Prof. of Medical Physics Faculty of Medicine Alexandria University.
X-Ray Interaction with Matter & Human Biology
Primary Exposure Factors IV
Chapter 18 Radiographic Exposure
IMAGE FORMATION  Introduction  The Invisible and Visible Image  Image Characteristics.
Components of Radiographic Image Quality
Radiographic Quality Chapter 5.
Digital Radiography.
Resident Physics Lectures
Topic 3 Selection of kV High kV scattered radiation is energetic. Angle of rays is same as those of primary beam and is not deflected very much. Follows.
MAMMO QC – covered in week 8
Analyzing the Image Density. Density Overall blackening of the image.
Prime Exposure Factors II By Professor Stelmark. Primary Factors The primary exposure technique factors the radiographer selects on the control panel.
X-ray radiography Seminar The "geometrical" unsharpness of X-ray images is limited by finite dimension of the source, i.e. the window on.
Chapter 15 Radiographic Intensifying Screens And Cassettes
Chapter 9 Film & Film Holders.
Radiation Interaction Q&A
BME 560 Medical Imaging: X-ray, CT, and Nuclear Methods
Advanced Higher Chemistry Unit 1 Spectroscopy. Spectroscopy  Spectroscopy is used to give information regarding the structure of atoms or molecules.
Image Formation Differential Absorption of X-rays by the Patient  Absorption of non-attenuated x-rays by screen  Emission of light  Formation of Film.
X-Ray Production & Emission
 QC testing of screen speed should occur on acceptance and then yearly.  Evaluate first whether similar cassettes marked with the same relative speed.
X-Ray Production & Emission
Intensifying Screens Kyle Thornton DMI 50B.
RAD 354 Chapt. 13 Intensifying Screens
FILM CASSETTES & INTENSIFYING SCREENS WEEK 9
RADIOLOGIC IMAGING EQUIPMENT 1. THE X-RAY ROOM 2.
INSTRUMENTATION. ELECTRICAL REQUIREMENTS AND EFFICIENCY  Effective voltage  High frequency inverter technology (over 10,000Hz)  Constant potential.
Medical Image Analysis Medical Imaging Modalities: X-Ray Imaging Figures come from the textbook: Medical Image Analysis, Second Edition, by Atam P. Dhawan,
DMI 261 Radiation Biology AndProtection. Unit 2 RADIATION Electromagnetic Spectrum –The frequency range of electromagnetic radiation and the photon wavelength.
Quality Control.
IMAGE QUALITY REVIEW RT
Dr Mohamed El Safwany, MD.
Resident Physics Lectures
Image Quality Radiographic Resolution.
Patient Interactions Photoelectric Classic Coherent Scatter
Mammography Questions and Answers
Chapter 2 The X-ray Beam.
RADIOLOGIC IMAGING EQUIPMENT 1. THE X-RAY ROOM 2.
Exposure Factors or Prime Factors
RTEC 111 Bushong Ch 2, 3 &15 Technique Math. Fundamentals of Radiologic Science RTEC 111 Bushong Ch. 2.
Chapter 6 Image Receptors Radiology. Introduction To further understand radiography, one must know how a permanent record is produced using x-rays. To.
Photon Tissue Interactions
PRINCIPLES OF TECHNIQUE AND EXPOSURE
Sensitometry By Prof. Stelmark. The study of the relationship between the intensity of exposure of the film and the blackness after processing is called.
Radiographic Quality Visibility and Sharpness
Image Quality Q&A. RAPHEX Diagnostic Question 2001 D9: The imaging system which is best for visualizing small high contrast objects is: A. Computed tomography.
RAD 254 Chapter 13 Intensifying Screens Physical purpose: to convert x-ray photons into light photons (done at the phosphor layer)
Attenuation As x-rays pays through matter, the exit beam will contain less photons than the entrance beam. This reduction in the quantity of photons is.
FILM CASSETTES & INTENSIFYING SCREENS WEEK 9
IMAGE RECEPTORS. Follow the Sequence- Film System Tube Tube Patient Patient (bucky) or non-bucky (bucky) or non-bucky Cassette Cassette INTENSIFYING SCREEN.
Medical Equipment Technology Department 1 Introduction to Biomed. Imaging Systems Lecture No.5-6 Dr. Yousif Mohamed Y. Abdallah.
DIGITAL IMAGING.
Fluroscopy and II’s. Fluroscopy Taking real time x-ray images Requires very sensitive detector to limit the radiation needed Image Intensifier (II) is.
Image Receptor Unsharpness By Professor Stelmark.
Tube Exposure Factors Math Technique Contrast and Density
Analog X-ray Imaging Recommended Book: Walter Huda, REVIEW OF RADIOLOGIC PHYSICS By: Maisa Alhassoun
Sergeo Guilbaud School of Radiologic Sciences
Exposure Factors or Prime Factors
Patient is placed between X-ray tube and silver halide film.
INTENSIFYING SCREENS.
Stacy Kopso, M.Ed., RT(R)(M)
Stacy Kopso, M.E.d. RT(R)(M)
Quality Control Testing of Screen Speed
Generation of X-rays Q&A
Presentation transcript:

Most of the images recorded during conventional radiography are obtained with film/screen combination image receptors. Which in lessens the patient dose due to the conversion of x-rays to light called luminescence.

 Can occur in two processes  Fluorescence  phosphorescence

 Fluorescence – is light of certain crystals emitted within seconds after the crystals are exposed to radiation. This means that light is emitted promptly. This is the type of luminescence that is desired for use in intensifying screen

 Phosphorescence – Is the light of certain crystals emitted sometime after 10-8 seconds after the crystals exposure to radiation, resulting to delayed emission of light.  This delayed emission is sometimes called after glow or lag.  This not desired for use in intensifying screens because the delayed emission of light fogs the film in the cassette before the radiographer can get it to the processor.

TThomas Edison developed the intensifying screen in 1896 LLater that year Michael Pupin first used a film/screen combination in radiography.

 The study of phosphorescence materials led to the discovery of radioactivity in  Henri Bequerel discovered radioactivity while studying different glow in the dark materials, which led him to think that the light emitted in the cathode rays tube are connect.

 The fluorescence light from the crystals in the in the intensifying screen is used to expose the film and creates 95% - 98% of the optical density.  Because only a relatively small number of x- rays are necessary for the screens to emit a relatively large quantity of light.  Which in tern lower patient dose is required.

 It refers to the amount of light emitted by the screen for a given amount of x-ray exposure.  A Screen that is designated as fast, creates an increased amount of light compared with a screen designated as slow when both are exposed to identical kVp, and mAs.

 Screen speed can be measured by intensification factor, relative name or speed value.  Intensification factor  The exposure required to create a certain optical density without a screen is divided by the exposure required with a screen to create the same optical density, w/c determines the intensification factor.

 Intensification factor = exposure w/o screens exposure w/ screens Example: If a 100mAs creates an optical density of 1.0 on a direct exposure film and a 5mAs creates the same optical density value with a film/screen combination. Then that screen has an intensification factor of 20. The larger this value, the faster the speed of the screen.

 Is the most common method of designating screen speed and is used for all screens with rare earth phosphors.  When one speed is changed to another, a change in mAs is required to maintain optical density.

 New mAs = Old mAs x Old relative speed value New relative speed value Answer: 5 mAs Example: If 10 mAs is used with a 100-speed screen, when using a 200-speed screen. What is the new mAs?

 Older, non-rare earth screen used specific names, such as fast or slow, to designate screen speed.

Name of ScreenRelative Speed Value Ultra high or hi-plus300 High or fast200 Medium, par, or standard 100 Detail, slow, or high resolution 50 Ultra – detail25

 Type of phosphor material  Thickness of phosphor layer  Size of phosphor crystals  Reflective layer  Light-absorbing dyes  Ambient temperature  Kilovolt (peak) selection

 Many different phosphor materials have been used in screens since  They are generally divided into two categories Rare earth Non-rare earth phosphor

 They are the original type of screen material and emit light in the blue-violet portion type of color spectrum.  Calcium tungstate  Barium strontium sulfate  Barium fluorochloride

 They were developed in the early 1970’s and are currently the most common type of intensifying screen materials.  The name rare earth is used because these materials have atomic numbers ranged in the lanthanide or rare earth in the periodic table of elements.

TThese materials possess a ggreater quantum detection efficiency (the ability to interact with x-rays) GGreater conversion efficiency ( the ability of screens to convert x-ray energy into light energy)

 Older calcium tungstate screens have a conversion efficiency of 4%-5%  Rare earth screens have values ranging from 15%-25%.  Rare earth are much faster than non-rare earth phosphors.  The rare earth are mixed with materials called activators (terbium, niobium, or thulium) that determines the intensity and color of light emitted.

Rare earth phosphorColor of emission Gadolinium oxysulfideGreen Lanthanum oxysulfideGreen Yttrium oxysulfideBlue-green Yttrium tantalateBlue-green Lanthanum oxybromide Blue Lutetium tantalateblue

 A thicker layer of phosphor material causes the screen to emit more light, because the extra material can absorb more x-rays.  This decreases the resolution of the resulting image because of increased light diffraction or diffusion.

True Image Unsharpness

 Rare earth screens are generally has better resolution because of their greater conversion efficiency therefore they do not have to be placed in as thick a layer.

 Using larger-sized phosphor crystals increases the spread of screen but decreases image resolution because of light diffusion.

 Faster speed screens add a layer of titanium dioxide to reflect light back toward the film.  This increases the speed but decreases the resolution because of the angle of the reflected light.

Reflected light X-ray photon Base Phosphor layer Reflective layer

 Slower speed screens have light absorbing dyes added to the phosphor layer to control reflected light.  This dye decreases speed but increases image resolution.

 When the ambient temp. of intensifying screen increases significantly above room temperature (above 85 0 F or 30 0 C) the screen may function slower than usual.  The higher temperature gives the phosphor crystal more kinetic energy.  It does not cause more light but increases the energy (color) of the light.  The film may not be sensitive to the new color so the image may appear underexposed.

 The phosphor material in a screen must interact with the x-ray photons for luminescence to occur.  The greatest absorption of x-rays occurs when the x-ray photon energy and the binding energy of the k-shell electron are almost the same.  K-edge effect.

 kVp must be match to the k-edge value  If values are not match for example of a dedicated mammography cassette usually has a lower k-edge value (15-20 keV) if the kVp used is at 100kVp it function much slower than if used at its proper kVp.

ElementAtomic number K-shell binding energy (keV) Yurium Barium Lanthanum Gadolinium Tungsten