Welcome to © 2009 Rational Acoustics LLC. All rights reserved. Rational Acoustics and Smaart are registered trademarks of Rational Acoustics LLC.

Slides:



Advertisements
Similar presentations
Working with Profiles in IX1D v 3 – A Tutorial © 2006 Interpex Limited All rights reserved Version 1.0.
Advertisements

Welcome to © 2009 Rational Acoustics LLC. All rights reserved.
CIMCO Integration Software Products
Microsoft Office XP Microsoft Excel
 Use the Left and Right arrow keys or the Page Up and Page Down keys to move between the pages. You can also click on the pages to move forward.  To.
Microsoft Office 2010 Office 2010 and Windows 7: Essential Concepts and Skills Mark Worden Instructor Use your spacebar or down arrow key to advance slides.
Page and Section Breaks, Word 2000
Chapter 5 Multitable Forms
Microsoft Word 2010 Lesson 1: Introduction to Word.
Windows XP Basics OVERVIEW Next.
© by Pearson Education, Inc. All Rights Reserved.
XP New Perspectives on Microsoft Office Access 2003, Second Edition- Tutorial 2 1 Microsoft Office Access 2003 Tutorial 2 – Creating And Maintaining A.
Creating And Maintaining A Database. 2 Learn the guidelines for designing databases When designing a database, first try to think of all the fields of.
Key Applications Module Lesson 12 — Word Essentials
PowerPoint Tutorial. Basic Vocabulary ► Slide - Presentation - Slide layout – ► ► ► a single page in PowerPoint all the slides for a speech all the slides.
Introduction to Excel 2007 Part 3: Bar Graphs and Histograms Psych 209.
DEMONSTRATION FOR SIGMA DATA ACQUISITION MODULES Tempatron Ltd Data Measurements Division Darwin Close Reading RG2 0TB UK T : +44 (0) F :
TrendReader Standard 2 This generation of TrendReader Standard software utilizes the more familiar Windows format (“tree”) views of functions and file.
8 Copyright © 2004, Oracle. All rights reserved. Creating LOVs and Editors.
Defining Styles and Automatically Creating Table of Contents and Indexes Word Processing 4.03.
1 iSee Player Tutorial Using the Forest Biomass Accumulation Model as an Example ( Tutorial Developed by: (
XP New Perspectives on Introducing Microsoft Office XP Tutorial 1 1 Introducing Microsoft Office XP Tutorial 1.
CTS130 Spreadsheet Lesson 3 Using Editing and Formatting Tools.
Microsoft PowerPoint Getting Started Guide Prepared for Towson University Dr. Jeff M. Kenton Amy Chase Martin 2007.
Dual-Channel FFT Analysis: A Presentation Prepared for Syn-Aud-Con: Test and Measurement Seminars Louisville, KY Aug , 2002.
IE 411/511: Visual Programming for Industrial Applications
Creating your own form from scratch.. To create a custom form, you can modify an existing form or design and create a form from scratch. In either case,
IC 3 BASICS, Internet and Computing Core Certification Key Applications Lesson 10 Creating and Formatting an Excel Worksheet.
Alice 2.0 Introductory Concepts and Techniques Project 1 Exploring Alice and Object-Oriented Programming.
1 The EDIT Program The Edit program is a full screen text editor that allows you to: Create text files Create text files Edit an existing text files Edit.
Chapter 3 – Part 1 Word Processing Writer for Linux CMPF 112 : COMPUTING SKILLS.
1 Microsoft Windows 2000 Robert H. Smith School of Business University of Maryland – College Park Essentials of Windows.
Office 2003 Advanced Concepts and Techniques M i c r o s o f t Access Project 5 Enhancing Forms with OLE Fields, Hyperlinks, and Subforms.
Windows Tutorial Common Objects ACOS: 1, 4. Using the Taskbar 1. Using the taskbar, you can switch between open programs and between open documents within.
Getting Started With AutoCAD ENGR 2 Week #1 Laboratory.
XP New Perspectives on Microsoft Access 2002 Tutorial 21 Microsoft Access Tutorial 2 – Creating And Maintaining A Database.
© 2011 Delmar, Cengage Learning Chapter 1 Getting to Know Illustrator.
1 TEISS Case Project Introduction Melinda Ronca-Battista and Angelique Luedeker ITEP/TAMS Center.
Lesson 11: Looking at Files and Folders what a file or folder is on the computer how to recognize a file or folder on the desktop how to recognize the.
Working with the virtual class Elluminate Live! Teacher’s interface eTeacher Ltd
© 2008 The McGraw-Hill Companies, Inc. All rights reserved. WORD 2007 M I C R O S O F T ® THE PROFESSIONAL APPROACH S E R I E S Lesson 15 Advanced Tables.
® Microsoft Office 2013 Access Creating a Database.
Microsoft Access 2010 Chapter 8 Advanced Form Techniques.
GISMO/GEBndPlan Overview Geographic Information System Mapping Object.
Chapter 4 Working with Frames. Align and distribute objects on a page Stack and layer objects Work with graphics frames Work with text frames Chapter.
As you look at an iMac you will notice that there are no buttons on the front of the machine as shown in figure 1.
Processing Lab 2 – Geometry Bryce Hutchinson Objectives: Add a dictionary Gain a better understanding of header issues Display geometry correctly Visualize.
Microsoft Access 2000 Presentation 3 Creating Databases Part II (Creating Forms)
Fall 2003Sylnovie Merchant, Ph.D. ACCESS Tutorial Note: The purpose of this tutorial is to provide an introduction to some of the functions of ACCESS in.
Velleman Oscilloscope: Windows 7 by Mr. David Fritz.
Computing Fundamentals Module Lesson 7 — The Windows Operating System Computer Literacy BASICS.
Getting Started with Word & Saving Guided Lesson.
Introduction to KE EMu Unit objectives: Introduction to Windows Use the keyboard and mouse Use the desktop Open, move and resize a.
Chapter 3 Device Monitor Screen Otasuke GP-EX! Chapter 3 Device Monitor Screen Chapter 3 Device Monitor Screen.
XP Foundation year Lec.4: Lec.4: Word Processing Software Using Microsoft Office 2007 Lecturer: Dalia Mirghani Year : 2014/2015.
When the program is first started a wizard will start to setup your Lemming App. Enter your company name and owner in the fields designated “Company Name”
Introduction to Drafting and Design In order to begin our drawing we have to set the drawing limits or the paper size.
Creating and Editing a Web Page
Photoshop Actions Lights, Camera, Actions in Photoshop.
When the program is first started a wizard will start to setup your Lemming App. Enter your company name and owner in the fields designated “Company Name”
Introduction to A+CAD. Objectives Understand fundamental CAD concepts Start A+CAD Tour the A+CAD interface Explore the different A+CAD data input methods.
IE 411/511: Visual Programming for Industrial Applications Lecture Notes #2 Introduction to the Visual Basic Express 2010 Integrated Development Environment.
 2002 Prentice Hall. All rights reserved. 1 Introduction to the Visual Studio.NET IDE Outline Introduction Visual Studio.NET Integrated Development Environment.
Key Applications Module Lesson 12 — Word Essentials Computer Literacy BASICS.
 You won’t write a single line of program code.  Instead, you’ll use visual programming techniques.  Visual Studio processes your actions (such as mouse.
Fundamentals of Windows Mouse n 4 Basic Operations: –Pointing –Clicking –Double Clicking –Dragging.
Microsoft Office Access 2003
Introduction to Excel 2007 Part 3: Bar Graphs and Histograms
Welcome To Microsoft Word 2016
Presentation transcript:

Welcome to © 2009 Rational Acoustics LLC. All rights reserved. Rational Acoustics and Smaart are registered trademarks of Rational Acoustics LLC.

An Introduction to Smaart v7 2

Initial View On first run of Smaartv7, we are presented with this view. As in previous versions, we begin our session by viewing an RTA measurement. This is Smaart’s way of telling you, “First step - check your input signals.” Seeing as this is our first run, we have no IO devices or measurements configured yet... So let’s begin there 3

Configuring Smaart v7 4

Configuring Inputs Smaart v7 is able to acquire input signals from any devices that have.wav, CoreAudio, or ASIO drivers recognizable by our computer’s Operating System. in fact we can grab multiple signals from multiple sources simultaneously ( Note: only one ASIO source can be accessed at a time ) 5

Configuring Inputs When Smaart v7 starts, you are presented with this splash screen 6

Configuring Inputs While you are being entertained with this lovely art, Smaart is busy checking to see what Input devices are available to your OS. It is here that Smaart builds its list of input devices, and once a device has been discovered, it will continue to show up for configuration in subsequent runs – even if it is not connected at start up. 7

Configuring Inputs While not absolutely necessary, we shall begin our measurement configuration by setting up our IO device(s). This includes: Setting the device’s sample rate, bit depth, and assigning the device and its channels “friendly names” - names that will help us as we configure our individual measurements 8

Configuring Inputs We configure our input device(s) from the “Audio IO” Options Dialogue We access this via the “Options Menu” or by using the *hot key command [Opt + A] * “Hot Keys” are Smaart’s built-in, keyboard-based commands Smaart Menu Bar 9

Options: Audio IO Choose your input device from the “Device” drop-down list Here you can assign “friendly names” to your device and its channels Note: Remember to hit [enter] when entering friendly names or they won’t be kept. 10

Configuring Measurement Groups Now that we have configured our Input device(s), the next step is configuring our measurements. Instead of a fixed measurement topology, Smaart v7’s object-oriented code base allows us to configure as many single-channel (Spectrum) and dual-channel (Response) sessions/objects as we wish. - and - These measurements can be run either individually or simultaneously, depending upon our requirements. In order to structure and manage our measurement configuration, we organize our measurements into Spectrum and Response “Groups”. 11

Configuring Measurement Groups To configure our measurements, we use the “Group Manager” Options Dialog We access this dialog box via the “Options Menu”, via the Group Manager button or by using the hot key command [Opt + G] Smaart Menu Bar or 12

Options: Group Manager Our first view of the Group Manager dialog. – No measurements configured – 13

Options: Group Manager Configuring Measurement Groups The Group “tree view” shows our complete measurement configuration. This menu is used to select the Group that is being configured, and to create/copy/delete groups. 14

Choose “New Input” to create a new Spectrum measurement in this Spectrum Group. The Group Tab view shows the entire selected group, with separate detail tabs for each individual engine. (Note: No measurements have yet been configured for this group, so the group tab is empty.) Options: Group Manager Configuring Measurement Groups 15

Choose “New Input” to create a new Spectrum measurement in this Spectrum Group. Give your Spectrum measurement a Name Choose the input device Choose the Input Channel from that device (Note: Device and Name use your Friendly Names if you set them in device config.) Options: Group Manager Configuring Measurement Groups 16

The new spectrum measurement can now be found in the Group Tree The Group Tab view now shows the new measurement. (Note: The measurement is assigned a color automatically. You can change this assignment by clicking on the color swatch and selecting another.) An individual spectrum measurement tab has been added to the Group. Options: Group Manager Configuring Measurement Groups 17

The new spectrum measurement can now be found in the Group Tree The Group Tab view now shows the new measurement. (Note: The measurement is assigned a color automatically. You can change this assignment by clicking on the color swatch and selecting another.) An individual spectrum measurement tab has been added to the Group. By repeating these steps, we can create as many measurements as we need in this Group. Options: Group Manager Configuring Measurement Groups 18

Select a response group in the tree view. And we can continue to Response Groups to configure dual-channel measurements. Options: Group Manager Configuring Measurement Groups Choose “New Pair” to create a new dual-channel Response measurement in this Response Group. Give your Response measurement a Name Choose the input device Choose the Meas. Channel from that device Choose the Ref. Channel from that device (Note: Both Meas. and Ref. channels must be from the same input device.) 19

The new response measurement can now be found in the Group Tree The Group Tab view now shows the new measurement. (Note: The measurement is assigned a color automatically. You can change this assignment by clicking on the color swatch and selecting another.) An individual response measurement tab has been added to the Group. Options: Group Manager Configuring Measurement Groups 20

Initial View Upon clicking the “OK” button... we are now back to our initial, starting view in Smaart v7 – a single measurement window view of RTA The big difference is now we have two spectrum/single-channel measurements configured! Now with measurements configured! 21

Configuring Smaart v7 We have now completed a simple, two channel configuration for Smaart v7. This configuration - with two spectrum and one response measurement - parallels the standard two channel configuration of previous versions of Smaart. We shall use this basic configuration for the next few sections of this introduction presentation. 22

Configuring Smaart v7 The Group Manager dialog is a powerful interface for configuring and controlling our measurement system, and we will revisit it multiple times and explore it more deeply throughout this presentation. 23

Basic Measurement Concepts NOTE: If you are not familiar with the basic measurement concepts of single-channel (spectrum) and dual-channel (transfer function and impulse response) measurements as realized in previous Smaart software versions, we highly recommend you read the Smaart Application Note: “Getting Started with SmaartLive” The fundamentals of our measurement have not changed – Smaart v7 has just expanded and refined how we make them. 24

A Quick Tour of the Interface 25

Plot Area This is where the action is – this is where our active and stored measurement data is displayed. Like in version 6, you can choose what type of measurement is shown in this data window via the drop-down selector in the top-left corner of this window. And as in version 6, clicking on either axis of the data window will zoom the window to the default ranges. 26

Plot Area – Click & Drag Now you can actively click on, grab and move RTA and Transfer Function traces using your mouse in the v7 plot area! On screen control handles! Various threshold controls (Spectrograph, Coherence Blanking) show up in, and can be modified from, the data plot area – on the fly! New in v7! 27

Cursor Readout As in past versions, here you find information about your cursor position. 28

Data Storage Smaart v7 includes two sets of easily accessible registers for the quick storage and retrieval our RTA and Transfer Function (.ref ) data. Capture using the standard [spacebar] hot key command or via the capture button. Load any Smaart data (v1 through v7!) that has been stored in our standard.ref file format. 29

SPL Readout Area Choose our input signal from any channel of any available input device. Set to full-scale readout or calibrate for SPL and Leq measurement Choose SPL settings for weighting and integration 30

Measurement View Control Like earlier versions of Smaart, measurement view buttons are used to determine what type of measurement data is displayed and how many widows are visible. 31

Measurement View Control The “Spect” button takes us to a default Spectrum view with one plot window showing RTA data This is also Smaart’s start-up view 32

Measurement View Control The Two-window View button takes us from a one-window to a two-window view. Pressing this while in “Spect” displays RTA over SpectroGraph 33

Measurement View Control The “Transfer” button takes us to a default Transfer Function view, with two plot windows: The Top Window displays TF Phase The Bottom Window displays TF Magnitude 34

Measurement View Control The “LiveIR” button opens the Live IR window when viewing a response measurement 35

Measurement View Control The “Impulse” button takes us to Impulse Response Mode And the “Real Time” button In IR mode takes us back to Real Time Mode This switch can also be triggered via the “Mode” Menu. 36

Signal Generator This strip controls Smaart’s signal generator. Pressing the button turns the generator on/off. Clicking on the level field brings up the generator control dialog 37

Measurement Controls This area is where we select and control our measurements. The controls presented here vary depending upon whether we are addressing Spectrum (single-channel) or Transfer Function (dual-channel) measurements 38

Measurement Controls The top labels also act as buttons to access the relevant Options dialogs Global measurement controls Measurement Group Select Group Level Commands Individual Measurements: Hide/Show Run Sig Level Delay Delay Find Track on/off 39

Spectrum Measurements 40

Spectrum Measurements Clicking the “Run” button on our first measurement starts it running. Our meter shows input signal level 41

Spectrum Measurements RTA display settings can be adjusted in the Spectrums Options dialog 42

Spectrum Measurements We can use the Global Spectrum controls to vary Scale and Averaging 43

Spectrum Measurements Full adjustment of all Global Spectrum measurement parameters can be accessed in the Group Manager 44

Spectrum Measurements Clicking the “Run” button on our second measurement starts it running as well. The lighter background color indicates that this is the “active” measurement - it is displayed in front of any other measurement 45

Spectrum Measurements Clicking on the first measurement makes it the “active” measurement and brings it to the front. The lighter background color indicates that this is the “active” measurement - it is displayed in front of any other measurement 46

Spectrum Measurements Clicking on its colored square hides a measurement trace and an “X” is shown. Even though a measurement’s trace is hidden, it is still running – as evidenced by its input meter. 47

Spectrum Measurements To capture data from the active measurement, click on a data Register slot then capture using either the “Capture” button or the [space bar] hot key. You can re-name your data by highlighting its name and typing a new one. 48

Spectrum Measurements Pressing the two-window button now brings up a view with RTA in the top window and Spectrograph in the lower window. RTA data trace now hidden 49

Spectrum Measurements Clicking the One-Window view button and choosing “Spectrograph” in the drop-down view selector gives us a full window view of the Spectrograph 50

Spectrum Measurements The Spectrograph view vertically displays a series of spectrum measurements or “slices”. Smaart v7 stores a slice history so we can scroll back through data which has passed off the screen. We can also control the number of vertical “pixels per slice” to adjust the measurement scroll speed. We adjust both of these settings in the Spectrum Options dialog. 51

Transfer Function Measurements 52

Transfer Function Measurements The “Transfer” button takes us to a default Transfer Function view, with two plot windows: Top: TF Phase Bottom: TF Magnitude With noise going through our speaker system, clicking the “Run” button on our measurement starts it running. 53

Transfer Function Measurements First steps in our Transfer Function (Frequency Response) measurement process is setting our input levels and setting our measurement delay 54

Transfer Function Measurements To measure the delay, we can use Smaart’s “Delay Finder” function 55

Transfer Function Measurements Increase Averaging to stabilize our measurement and Adjust Mag and Phase Trace Smoothing to improve readability Note: The Coherence trace will not be available until we engage averaging. The Coherence blanking threshold control *Remember, we can adjust trace offset by “clicking” directly on a trace and “dragging” it up and down. 56

Transfer Function Measurements Engaging Live IR shows us a linear view of the Impulse response of the active TF measurement Note: Window is centered on the current measurement delay time. 57

Transfer Function Measurements Smaart v7’s delay Track uses the Live IR function to automatically and continuously measure and adjust the measurement delay Yellow Dot indicates tracking is engaged Click on the “Track” Button or Yellow Dot to engage Tracking 58

Transfer Function Measurements Full control of all Global Transfer Function measurement parameters can be accessed in the Group Manager 59

Transfer Function Measurements TF display and Live IR measurement settings can be adjusted in the TF Options dialog 60

Impulse Response Mode 61

Impulse Response Mode The primary purpose for this mode is to perform and analyze Impulse Response Measurements in both Time Domain and Frequency Domain In this mode, we can also analyze previous IR measurements that have been stored in standard.wav audio file format 62

Impulse Response Mode To make a IR measurement we: select a configured Response Measurement set our measurement FFT size / TC adjust our signal levels hit Start 63

Impulse Response Mode Our IR shows the entire measurement in Linear view in our Top window. This window serves as navigation and zoom control. 64

Impulse Response Mode The Lower Window(s) are our zoom windows where we can view all or part of our measurement is a number of different ways. We can control the number of zoom windows with our standard single/dual window buttons and determine what our measurement view for each is via our drop-down view selector menus 65

Impulse Response Mode This window is displaying a Log view of our Impulse 66

Impulse Response Mode This window is displaying a Linear (zoomed) view of our Impulse This window shows the bottom window zoom range 67

Impulse Response Mode For a more interesting IR, we shall a previously stored IR 68

Impulse Response Mode Here we have an IR from a much larger environment 69

Impulse Response Mode We can filter the IR with either Octave or 1/3 Octave filters 70

Impulse Response Mode 71

Impulse Response Mode The dynamic range controls for the Spectrograph view appear on the Log IR 72

Impulse Response Mode IR display and Spectrograph measurement settings can be adjusted in the IR Options dialog 73

Going Multi-Measurement 74

Going Multi-Measurement 75 AmpSpeakersX-Over (Spkr. Proc) System Control DSP EQ Delay Level Polarity Routing Computer Audio I/O Source Mic 1 Mic 2 Mic 3 Smaart Signal Gen Out We can expand our measurement system beyond 2 Channels

Why Measurement Groups? The short answer is, it depends upon our measurement needs and the complexity of our measurement system. In the case of Spectrum Measurements, we could build a Group for each input device that we use. This will allow us to quickly check signal presence for our devices. 76

Why Measurement Groups? Here we see the spectra of the five input channels that we are using from our device “PreSonus FireStudio” 77 Measurement Group Select

Why Measurement Groups? In the case of Response Measurements, we could build Groups for each sub-system we plan to measure. This allows us to better organize our measurement process as well as the resulting data we capture. 78

Why Measurement Groups? 79 Our Group Names indicate the subsystem we shall be measuring Our first three response measurements in this Group are measurements of the Main Left speaker system from three separate Mic positions: Balcony, FOH and Roaming Each measurement uses Console L Out as its Ref

Why Measurement Groups? 80 The fourth Response measurement in our Mains Left Group is a measurement of our Left System EQ. Here we use EQ Out L as our Meas and Console L Out as our Ref Since this “Left EQ” measurement is a purely electronic measurement, we may want to adjust some of our measurement parameters for this response separate from the Global settings. To do this, we access its individual measurement Tab. Here we choose to fix the averaging for this measurement to “16” by un-checking the “Use Global” box. We also fix the Mag and Phase Smoothing to “None” If want, we can also have the trace for this measurement graph inverted

Why Measurement Groups? 81 The fifth Response measurement in our Mains Left Group is a live average of our first three response measurements which we have named “ML Average” We highlight our AVG response and then choose the measurements from this group that we wish to include in this live average To create this response measurement we use the “New Average” button.

Multi-Channel Measurement 82 Here we have our five Simultaneous Response Measurements

Multi-Channel Mania 83 And here, we swap the Phase display for RTA