Isolated high speed 8 channel multi function logger midi LOGGER GL900 Product introduction midi LOGGER GL900 Product introduction The data logger that.

Slides:



Advertisements
Similar presentations
ETM Series Digital Video Recorders
Advertisements

A new Network Concept for transporting and storing digital video…………
What is Arduino?  Arduino is a ATMEL 168 micro-controller kit designed specially for small projects  User friendly IDE(Integrated Development Environment)
Analog-to-Digital Converter (ADC) And
THS3000 Product Introduction Market Dynamics  Customers require more flexible solutions  Many test solutions are driven by both measurement needs.
TandD RTR-500 Series Family of Wireless Data Loggers Multiple Data Collection Options Suite of Software Tools.
Digital to Analogue Conversion Chapter 13. Why is conversion needed? Most signals in the world are analogue. Microprocessors and most computers computers.
© Paradigm Publishing, Inc. 2-1 Chapter 2 Input and Processing Chapter 2 Input and Processing.
Introduction of iVMS-4200 v2.0
ACR Systems Inc. ISO 9001 Registered World Class Data Loggers.
Data Acquisition Concepts Data Translation, Inc. Basics of Data Acquisition.
© 2009 Pearson Education, Upper Saddle River, NJ All Rights ReservedFloyd, Digital Fundamentals, 10 th ed Digital Fundamentals Tenth Edition Floyd.
1 Lab Equipment. 2 TopicSlides DC Power Supply3-4 Digital Multimeter5-8 Function Generator9-12 Scope – basic controls13-20 Scope – cursors21-24 Scope.
Fluke Oscilloscope 4 Isolated Channels 200 Mhz Bandwidth CAT III 1000 CAT IV 600 Rated 2.5 GS/s sample rate Connect-and-View™ IP-51 Rated.
Dataloggers. Records voltage, current, or circuit closing Environmental variables must be converted to electronic signal.
Data Logger for Water Meter Function Continuously counts pulses from pulse output of the water meter (or other meters with pulse output) and periodically.
Temperature is more than just hot or cold - You are responsible for temperature - we give the tools.
Parts of a Computer.
Pocket Multi-channel Signal Analyzer IIntroduction Key Features Applications Key Specifications Hardware Connections.
Oscilloscope Tutorial
3D Micromanufacturing Lab. School of Mechatronics Gwangju Institute of Science and Technology 3D Micromanufacturing Lab. School of Mechatronics Gwangju.
DEMONSTRATION FOR SIGMA DATA ACQUISITION MODULES Tempatron Ltd Data Measurements Division Darwin Close Reading RG2 0TB UK T : +44 (0) F :
1 SD Recorder OS-TM-V701A for Driving Security Surveillance.
STYLITIS-101 Advanced, portable data acquisition system covering a wide range of measurement and recording needs.
EMBEDDED WEB SERVER. CONTENT: 1.ABSTRACT 2.INTRODUCTION TO EMBEDDED SYSTEMS 3.INTRODUCTION TO EMBEDDED WEB SERVER 4.BLOCK DIAGRAM 5.POER SUPPLY 6.COMPONENT.
Programmable logic control Data Processing Computer System Key Board Light Pen Mouse PLC a Process Control Computer System Motion Sensor Sound Sensor.
TRANSMILLE PATs The New Alternative To Fast, Easy & Efficient Portable Appliance Testing.
 Chasis / System cabinet  A plastic enclosure that contains most of the components of a computer (usually excluding the display, keyboard and mouse)
Looking for a more powerful circuit monitor?
Higher Computing Computer Systems S. McCrossan 1 Higher Grade Computing Studies 4. Peripherals Input Devices Keyboard Mouse Scanners Microphone Digital.
Digital Fundamentals Floyd Chapter 1 Tenth Edition
1 Computing Basics Honolulu Community College Cisco Academy Training Center Semester 1 Version
GML-3 GPRS BASED METER AND LOGGER THREE PHASE METER WITH INBUILT DATA LOGGER © Embuilt Technologies Visit us at Or For.
A modern NM registration system capable of sending data to the NMDB Helen Mavromichalaki - Christos Sarlanis NKUA TEAM National & Kapodistrian University.
NV V5.7 Product Presentation. Brand New Professional GUI  Multiple User Interface for different look and feel  Audio indicator on camera (play audio.
Page 1 ADAM-6000 Web-enabled Smart I/O Γιάννης Στάβαρης Technical Manager Ιούνιος 26, 2007.
NetVuze Precision Network Meter standalone, easy to use, networked with data logging.
Ircon ® ScanIR ® 3 Linescanner How to work with Snapshots? Confidential Rev. A 07/2013.
Schutzvermerk nach DIN 34 beachten XC200 Hardware Overview.
USB DAQ Product USB DAQ Product Κώστας Γρηγορίου Sales Engineer Ιούνιος 26, 2007.
WaveSurfer 3000 Oscilloscopes Public Release – July 1 st, 2014.
DVR MH1600M H CH DVR Key Features Key Features Connection Diagram Connection Diagram 16ch Stand-alone DVR All Channels real-time Monitoring / Recording.
Gauge Operation and Software by Scott A. Ager. Computer Recommendations 750 MHz Pentium III 64 Meg SRAM 40 Gig Hard Drive 1024 x 768 graphics CD Writer.
© 2009 Pearson Education, Upper Saddle River, NJ All Rights ReservedFloyd, Digital Fundamentals, 10 th ed Digital Fundamentals with PLD Programming.
V5.7 SP2 New Features Pre-sale material. INDEX 1  Schedule Relay Activation Schedule Relay Activation  UPNP for Port Setting UPNP for Port Setting 
DIGITAL RECORDING SYSTEM Installation Setup Wizard About Our Software.
1 Weblite Product Introduction. 2 Control Equipment via the Internet 8 Universal Inputs 8 Universal Outputs software selectable as analog or digital signals.
1 Course Title: IT IN BUSINESS Course Instructor: ADEEL ANJUM Chapter No: 04 1 BY ADEEL ANJUM (MCS, CCNA,WEB DEVELOPER)
STYLITIS-41 … is suitable for measurements in Meteorological, Wind/Hydro potential and other Environmental fields.
SmartMQn Motor Horner APG, LLC September 9, 2008.
RTLS. LOCATING / POSITIONING SYSTEMS A positioning system is a mechanism for determining the location of an object in space Interplanetary systems Global.
SEMINAR ON P.L.C. SUBMITTED BY HRIDAY MUKHERJEE AMIT DEBNATH SOMNATH SHIL
ACT20X Ex isolator/ amplifier. Page 2 ACT20X (Ex isolators family) Overview - Connects to process equipment in Class/Div, or Zone 0 - Zone 2 areas - ACT20X.
Garage Band For MAC. What is it? A digital audio workstation that can record and play back multiple tracks of audio. Is a software application for OS.
1 Data Acquisition, Monitoring & Management Solutions Supplied by DCM Transcal Phone or
DL750P On Sale Now 1 DL750P Promotional Material.
Computer is a general-purpose device that can be programmed to carry out a set of arithmetic or logical operations automatically. Since a sequence of.
Cold-Chain Expert, Total Solution Quality Precision Service Value
USB DAQ Product Introduction
EKT124 Digital Electronics 1 Introduction to Digital Electronics
Application Case Study Security Camera Controller
H.264 4ch/8ch/16ch Stand Alone DVR
Model /21 Clamp on Power HiTESTER
SCADA for Remote Industrial Plant
Ultra-High Performance Low-Power Audio Recorder
Cover page.
Neurochip3.
Oscilloscopes HP 54600B Digital Oscilloscope Alex Jones COE 0501.
DVR LH-Series 1 Key Features H.264 8ch/16ch Stand Alone DVR
Digital Fundamentals Floyd Chapter 1 Tenth Edition
Presentation transcript:

Isolated high speed 8 channel multi function logger midi LOGGER GL900 Product introduction midi LOGGER GL900 Product introduction The data logger that meets with various equipment tests NEW GRAPHTEC CORPORATION

Out line Out line Recently, improvement of product durability becomes more important as a development theme for the electronics equipments and industrial equipments, so the drop down test, vibration test, mechanical shock test and environment test have been performed more frequently. Especially for the durability test for mechanical movement parts and driving parts, several ten thousands times or several thousands hours durability test are often performed. Based on these backgrounds, high speed sampling and long time data capturing and simultaneous measurement for several phenomena (voltage, temperature and high voltage) are strongly required for the measurement equipments. Also for the long time durability test for multiple products, it is required that the number of test equipment needs to be increased, so compact and reasonable price measurement equipments are required for capturing of these test data. We provide the midi LOGGER GL900 that is an 8 channels isolation input for safe measurement for these various product tests. Further more, the multifunction input which corresponds to 500V DC high voltage, humidity, pulse and logic input for measurement of various phenomena.

Target of the GL900 Target of the GL900 Company H MS/s 100KS/s Company K NR600 Company K GR7000 Company Y DL750P Company N RA2300 Company H How many customers measure 1MS/s measurement by their measurement equipment which has the 1 MS/s sampling capability? We guess that the actual measurement 100 KS/s (10 micro second sampling) or slower, isn’t it? Graphtec provides practical specification and price of products to meet customer’s actual frequency band. Price(MSRP) Instantaneous phenomenon ・ Drop down test ・ Mechanical shock test ・ Vibration test Long time measurement ・ Durability test ・ Tension/Compression test ・ Environment test Main application GL900: Competitive price 8 channels, isolation, simultaneous sampling Sampling Speed ( Sample / sec ) Company Y SL1400 Company H 8841 (Million yen)

>Large size 5.7 inch color LCD for bright and easy- to- read waveform display > Data capture for USB memory which can easily be connected to the PC > 16 bits A/D resolution with High speed 8 channels simultaneous sampling >8 channels isolated multi function input Main features Main features

Isolated high speed 8 ch multi function logger Isolated high speed 8 ch multi function logger The midi LOGGER GL series are popular as the handy type logger, now, the GL900 is designed as vertical operation for customer’s usage. Also the size is drastically reduced as an isolated high speed measurement equipment. 232mm 150mm 80mm

4 ch for either Logic or Pulse For pulse, Revolutions, Counts, Instant are selectable for each channels BNC terminal for easy connection of voltage input Screw terminal for easy connection of thermo couples Isolated input for safe connection and variety of input ranges for corresponding various test items Voltage: 20 mV to 500 V (Between + and - terminals : Max 500 V p-p) Temperature: Thermocouple Humidity: Humidity sensor (B-530) Logic or Pulse: (Revolution, Integration and Instant) 4ch separated from analog 8ch input Multi-function input with isolated 8 channels Multi-function input with isolated 8 channels

Corresponding to high voltage measurement Corresponding to high voltage measurement AC power supply Sequence : Logic Current : Clamp meter Voltage Temperature : Thermo couple CM-211 CM-113 Humidity : Dedicated humidity sensor Wide 500 V range is provided for voltage input, so it corresponds 100 to 200 V AC power supply waveform measurement. Also, using with the logic input and clamp meters, power supply voltage and current and the sequence control can be measured as the same time. When input each signal as voltage, it is possible to convert to original unit using the unit conversion function Clamp meter

Max. sampling 10 sec with all channels simultaneous sampling A/D resolution is 16 bit high resolution High speed 8ch simultaneous sampling with 16 bit high resolution Storage Oscilloscope 100M 1M 10K 10 Data logger GL900 Memory recorder Sampling speed (S/s) A/D resolution (bit) 1K 20M Temperature Dynamic characteristics Control signal Circuit signal Speed-up High resolution Signal 100K Storage destination10 s100 s500 s1ms10ms100ms1s1min 64 MB internal memoryYes 256MB internal Flash memory No Yes USB memoryNo Yes

Corresponding to various measurement scene Capture destination10μs100μ s 500μs1ms10ms100ms1s Internal RAM (1 million point max.) 10 sec 100 sec 8 min 20 sec 16 min 40 sec 2 hours 46 min 1 day 3 hours 11 days 13 hours 256 MB internal flash memory ×××11 hours4 days49 days 493 days 512 MB USB memory ×××22 hours8 days98 days 986 days Application ・ Drop down test ・ Shock test ・ Vibration test Application ・ Durability test ・ Tension/Compression test ・ Environment test High speed phenomena such as the drop down test and the mechanical shock test can be measured with 1ms or faster high speed sampling then stored to internal RAM for max. 1 million points. Also all channels are simultaneously sampled without time difference between channels, it is possible to check the correlation of each parts. Further more, 1ms to 1min slow sampling is for the durability test, and large size 256MB internal flash memory or external USB memory can store long time measurement.

・ Bright and easy-to-read, Large size 5.7 inch color LCD ・ Simple setting operation by cursor keys ・ High speed waveform can be enlarged or reduced, Oscilloscope like operation Large size 5.7 inch color LCD for bright and easy-to- read waveform display Simple setting operation by cursor keys Easy-to-read large size 5.7 inch color TFT LCD Magnifying of time axis Compression of time axis TIME/DIV key 10ms / DIV to 1 min / DIV

Previously, measurement equipment needs to record the input signal once to confirm the waveform before start measurement. But the GL series installs the free running display function, so the input signal is displayed on the screen soon after power on, you can check the input signal soon, and easily set the measurement condition within short period of time. Easy setting operation with the free running display function the free running display function Previous models Press START key to start measurement, check the input signal and press STOP key Set input range Press START key again to start measurement, check the input signal and press STOP key Press START key to start actual measurement If necessary, repeat above steps Check input signal by free running display Set the input range Press START key for actual measurement GL900 Waveform display area Waveform is displayed during setting for easy operation TIME/DIV, Position and Span setting can be done in the free running display Display scroll Max..: 10ms/DIV

Following two file formats are selectable GBD (Graphtec binary data) format : data size is smaller than CSV format CSV format : You can open it by Excel or other software without using any dedicated software The USB memory can be used as the external memory device. If you specify the USB memory as the capture destination, the data is directly stored to the USB memory. Also, for the long time measurement such as the durability test, you can measure it just by use the USB memory which has necessary data capacity. The transfer to PC is also possible just by insert the USB memory to the PC. * The max. file size for measurement data is 2GB. Please use standard type USB memory which does not support the functions such as the finger print recognition. Data can be stored to USB memory which easily can be connected to the PC which easily can be connected to the PC External USB memory terminal Data can be transferred to the PC easily.

Using the combination of trigger function and timer function, only necessary data can be stored without capturing wasted data. Wealth of trigger and timer function Jan. 1Jan. 5Jan. 10Jan. 15Jan. 20Jan. 25Jan. 30 Timer Mode : Day/TimeStart Settings : Date 2008 – Time 00 : 00 Start Settings : Date 2008 – Time 23 : 59 Trigger SettingsStart Source : Off Stop Source : Off Timer Settings Timer ModeOff, Day/Time, Daily, Hourly Trigger Settings Start SourceOff, Level, Ext. Stop SourceOff, Level, Ext., Time Pre Trigger 0 to 100 % Repeat measurementOn/Off and repeat interval : Data capture : Timer is activated Example 1 : When measure 4 days from Jan. 10 Only when the capturing destination is internal RAM Start key On

Wealth of trigger and timer function 00 :0004 :0008 : 0012 : 0016 : 0020 : 0024 : 00 Timer Mode : Off Trigger SettingsStart Source : Off Stop Source : Time Time Settings : 1 h 00 min 00 sec Repeat : On Rep. int. : 0004 h 00 min : Data capture Example 3 : When measure 1 hour in 4 hours interval every day Repeat interval is counted from the time when trigger is activated Repeat interval : 4 hours 00 : 0012 : 0000 : 0012 : 0000 : 00 Start Trigger : 3V Stop Trigger : 2V Timer Mode : DailyStart Settings : 09 : 00 Stop Settings : 17 : 00 Trigger SettingsStart Source :Level Level Settings : CH1, Mode : H, Level : 3 V Stop Source:Level Level Settings : CH1, Mode: L, Level : 2 V Repeat : On 5V 0V0V : Data capture : Timer is activated Example 2 : When measure abnormal signal of equipment during working time : Trigger point Measurement finishes by the priority for timer setting Start key On

Wealth of trigger and timer function 00:0001:0002:0003:0004:0005:0006:00 5V 0V : Data capture : Timer is activated Example 4 : When measure for 20 minutes in every hour 00:0001:0002:0003:0004:0005:0006:00 Start Trigger 3V Stop Trigger 2V 5V 0V Example 5 : When measure only abnormal signal within 20 minutes of every hour Measurement stops by the priority for timer setting Start key On Timer Mode : HourlyStart Settings : 00 min 00 sec Start Settings : 20 min 00 sec Trigger SettingsStart Source : Off Stop Source : Off : Data capture : Timer is activated : Trigger point Timer Mode : HourlyStart Settings : 00 min 00 sec Stop Settings : 00 min 20 sec Trigger SettingsStart Source :Level Level Settings : CH1, Mode : H, Level : 3 V Stop Source:Level Level Settings : CH1, Mode: L, Level : 2 V Repeat : On

Possible to use as X-Y recorder Possible to use as X-Y recorder Duplicating the X-Y recorder’s action. Pen up/down action is duplicated, so it is possible to use like an analog X-Y recorder. Corresponding to Max. 4 pen X-Y recorder. Also, the data is digital format, so you can easily check the data and create the report after finish the measurement. Point moves as if pen moves If capturing the screen copy then paste on the Excel, you can use it as report. Pen moving can be checked with pen-up condition Waveform is displayed by pen-down. Data capture starts by measurement start. After finish measurement, data can be check by digital value using cursor.

NTP server Ethernet The GL900’s time can be synchronized to the NTP server’s time at periodic intervals. ( NTP : Network Time Protocol ) Setting, control and data can be transferred without using the standard attached software Ethernet FTP client function The data captured to the GL900’s internal memory or the USB memory stick can be automatically backed up to the FTP server at fixed intervals USB drive mode USB drive mode is a fast and easy way to transfer data from internal memory to an external computer NTP client server function WEB server function Waveform display and GL900 settings can be made via a web browser such as Internet Explorer Ethernet USB USB DRIVEMODE USB and Ethernet is provided as standard (dedicated PC software is attached) Using USB dive mode, WEB server and FTP server function, you can transfer the data to PC, and control and setting of GL900 from PC is possible. Remote control and data transfer is possible Ethernet / USB USB I/F Ethernet I/F

ItemDescription Number of input channels8ch Type of input terminalBNC and M3 Screw type terminal MethodAll channels isolated, Simultaneous sampling Measurement range Voltage20mV to 500V / F.S. (Between + and – terminals, 500 V p-p max.) TemperatureThermocouple: K, J, E, T, R, S, B, N, W(WRe5-26) Humidity0 to 100% ( When using optional B-530 humidity sensor is used ) External input / output InputTrigger: 1ch, Selectable between pulse and Logic: 4ch OutputAlarm: 4ch A / D converter16bit(out of which 14 are internally acknowledged) Maximum sampling interval10 micro-second Internal memory size RAM : 1 million data, 256MB Flash memory External memoryUSB memory (1 file 2 GB) Calculation functionStatistics calculation, Searching function Display5.7 inch TFT color LCD Interface to PCEthernet ( 10BASE-T / 100BASE-TX ), USB (Compatible with full speed) Operating environment Temperature : 0 to 40 ℃ (15 to 40 ℃ when operating by battery ), Humidity : 5 ~ 85 % R.H. Power supply AC adapter ( 100 to 240V AC,50 to 60Hz ), DC input ( 8.5 to 24V DC) Battery pack : 2 batteries installable External dimensions (approx.)232W x 150H x 80D mm Weight (approx.)1.1kg ( Excluding the AC adapter and battery ) Vibration resistanceCompatible with JIS Vibration testing methods for automobile Type 1 Class A-equivalent GL900 Specifications

Accessories Accessories ItemModelRemark Battery packB batteries need to be installed when operate Logic alarm cableB-5132m DC power cableB-5142m Humidity sensorB-5303m Safe probeRIC-1411:1, 42pF BNC – BNC cableRIC m BNC – Banana cableRIC m BNC –Alligator Clip cableRIC m