Status and Challenges for Detectors in Nuclear Physics

Slides:



Advertisements
Similar presentations
Neutron detectors and spectrometers 1) Complicated reactions → strong dependency of efficiency on energy 2) Small efficiency → necessity of large volumes.
Advertisements

HEP Experiments Detectors and their Technologies Sascha Marc Schmeling CERN.
Detecting and Measuring Ionizing Radiation -2
Radiation Detectors / Particle Detectors
PROVIDED BY EMAD BEHDAD SPECIALIZED PROTECTION AND CORROSION OF MATERIALS LECTURERS H.MONAJATI,PHD JAFARI,PHD ISLAMIC AZAD UNIVERSITY OF NAJAFABAD BARANCH.
Special Focus Workshop “Towards 10 ps single soft photon detectors” 2013 IEEE NSS/MIC/RTSD Seoul Sunday Oct 27, 2013.
Scintillators. When radiation interacts with certain types of materials, it produces flashes of light (scintillation) Materials that respond this way.
Click to edit Master title style IEEE short course Calorimetry Erika Garutti (DESY Hamburg, Germany) Michele Livan (University of.
Detection of Gamma-Rays and Energetic Particles
X-ray Astronomy Lee Yacobi Selected Topics in Astrophysics July 9.
Atomic X-Ray Spectroscopy Chapter 12 X-ray range  Å to 100 Å Used  0.1Å to 25 Å.
Nuclear Physics: Radiation, Radioactivity & its Applications.
Lesson 17 Detectors. Introduction When radiation interacts with matter, result is the production of energetic electrons. (Neutrons lead to secondary processes.
Scintillators.
Experimenting with Quarks Prof. Richard Jones University of Connecticut, Storrs Science Symposium, Darien High School, May 28, 2008.
High Energy Detection. High Energy Spectrum High energy EM radiation:  (nm)E (eV) Soft x-rays X-rays K Soft gamma rays M Hard gamma.
Radiation Safety level 5 Frits Pleiter 02/07/2015radiation safety - level 51.
Main detector types Scintillation Detector Spectrum.
Lecture 2-Building a Detector George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
Paul Sellin Detector Research at the University of Surrey Dr Paul Sellin Centre for Nuclear and Radiation Physics Department of Physics University of Surrey,
Detectors of charged particles and ions 1) Gas filled detectors a) Ionization chambers b) Proportional counters c) Multiwire chambers d) Time projection.
Gamma Spectroscopy HPT TVAN Technical Training
2: Radiation Measurements
Gamma rays detectors 1) Comparative characteristics of detectors
Radiation Detection and Measurement II IRAD 2731.
Atomic X-Ray Spectrometry - Ch12
Detectors The energy loss of particles in matter can be used detect and identify those particles. There are different types of “detectors”: - Gas-filled.
Principles of Radiation Detection
Chapter 6 Principles of Radiation Detection. Measurement of Radiation X-rays and electrons produced by radiation therapy treatment machines are measured.
Instruments for Radiation Detection and Measurement Lab # 3 (1)
Neutron Generation and Detection Lee Robertson Instrument & Source Division Oak Ridge National Laboratory 17 th National School on Neutron and X-ray Scattering.
Type of Material: Instrumentation Review
RAD2012, Nis, Serbia Positron Detector for radiochemistry on chip applications R. Duane, N. Vasović, P. LeCoz, N. Pavlov 1, C. Jackson 1,
Photon detection Visible or near-visible wavelengths
History of nuclear spectroscopy
1 Scintillators  One of the most widely used particle detection techniques Ionization -> Excitation -> Photons -> Electronic conversion -> Amplification.
Chapter 12 Atomic X-Ray Spectroscopy
Objectives To learn the types of radioactive decay
FISICA AMBIENTALE 1 Radioattività: misure 1 Lezioni Marie Curie.
Tools for Nuclear & Particle Physics Experimental Background.
Heavy Ion Laboratory Warsaw University Jarosław Choiński.
Half-life It's impossible to predict when a specific atom is going to decay, but you can predict the number of atoms that will decay in a certain time.
Instrumentation Review. Direct and Indirect Ionization Direct - Charge particles that strip away electrons from atoms Indirect - uncharged that have to.
Seeing the Subatomic Stephen Miller Saturday Morning Physics October 11, 2003.
Scintillation Detectors
3/2003 Rev 1 II.3.4 & 13-15a – slide 1 of 31 Part IIQuantities and Measurements Module 3Principles of Radiation Detection and Measurement Session 4,Liquid.
II. DETECTORS AND HOW THEY WORK
PHYSICS 225, 2 ND YEAR LAB NUCLEAR RADIATION DETECTORS G.F. West Thurs, Jan. 19.
Medical applications of particle physics General characteristics of detectors (5 th Chapter) ASLI YILDIRIM.
Lecture 3-Building a Detector (cont’d) George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
Prospects to Use Silicon Photomultipliers for the Astroparticle Physics Experiments EUSO and MAGIC A. Nepomuk Otte Max-Planck-Institut für Physik München.
Chapter V Radiation Detectors.
Nuclear Medicine Instrumentation 242 NMT 1 Dr. Abdo Mansour Assistant Professor of radiology
MODES_SNM Modular Detection System for Special Nuclear Material FP7-SEC G. Viesti Dipartimento di Fisica ed Astronomia Università di Padova.
Gamma Spectrometry beyond Chateau Crystal J. Gerl, GSI SPIRAL 2 workshop October 5, 2005 Ideas and suggestions for a calorimeter with spectroscopy capability.
Radiation detectors Ion chamber 2. Geiger Muller counter (GM).
Topic 6 : Atomic and Nuclear Physics.
Diagnostics of FRIBs beam transport line
PAN-2013: Radiation detectors
Gamma Rays Detection LNF – | INSPYRE school Danilo Domenici
Outside the nucleus, the beta decay {image} will not occur because the neutron and electron have more total mass than the proton. This process can occur.
Neutron Detectors for Materials Research
1 Principles of Radiation Detection Operational Radiological Safety Course U.S. Army Chemical Biological Radiological & Nuclear School Edwin R. Bradley.
Radiation Protection Service University of Glasgow Lecture 2: Detecting Radiation Detecting Ionising Radiation James Gray University RPA.
Radioactivity B. Sc. -III Feb Dr. Wagh G. S. M. Sc. M. Phil. Ph
Detecting Ionising Radiation
PARTICLE DETECTORS I recently joined the IAEA.
PHYS 3446 – Lecture #16 Monday ,April 2, 2012 Dr. Brandt
Heavy Ion Laboratory Warsaw University Eryk Piasecki.
PHYS 3446 – Lecture #17 Wednesday ,April 4, 2012 Dr. Brandt
Presentation transcript:

Status and Challenges for Detectors in Nuclear Physics Yacouba Diawara I recently joined the IAEA ERDIT Meeting, CERN 11-12 April 2013

Some Important Facilities and Experiments: Nuclear spectrometry (incl. radioactive beams, AGATA, GERDA, NUSTAR, FAIR, Spiral2) Hadron physics (Jefferson lab, PANDA at FAIR) Heavy ion physics (RHIC, ALICE) Ion beam accelerators Spallation sources and research reactors Nuclear applications (dosimetry, environmental monitoring, cultural heritage) Etc …. Here is a list of some important facilities and experiment in nuclear physics. The list is not complete and it shows how challenging is to summarize the various detectors used in these facilities. ERDIT Meeting, CERN 11-12 April 2013

Presentation 1 - Overview of the different types of detectors used in nuclear physics 2 - Few applications at the IAEA 3 - Future directions 4 - Conclusions Two applications being conducted in our team at the IAEA will be shown. ERDIT Meeting, CERN 11-12 April 2013

Overview Various types of radiation detectors are used depending on the energy and the type of particle to be counted and the purpose of the measurement. The 3 mains types of radiation detectors are the gas-filled detectors, the scintillators-based and the semiconductor detectors ERDIT Meeting, CERN 11-12 April 2013

Gas-filled Detectors Description The 3 main regions Ionization chamber: The output signal is proportional to the particle energy dissipated in the detector. The measurement of particle energy is possible. Only strongly ionizing particles (α, protons, fission fragments, or heavy ions) are detected. Application: Beam monitoring The charge collected stays constant despite a change in the voltage. No new charge is produced. ERDIT Meeting, CERN 11-12 April 2013

Gas-filled Detectors Description Proportional Counters Charge multiplication takes place and the output signal is proportional to the particle energy deposited in the detector. Measurement of any charged particle is possible. Applications: Counters, LPSD and 2D detectors The electrons produce secondary ionization that results in charge multiplication. Particle identification and energy measurement are possible. ERDIT Meeting, CERN 11-12 April 2013

Gas-filled Detectors Description Geiger Counter Operation in avalanche mode. The signal is strong and no amplifier is required and their signal is independent of the particle type and its energy. GM provides information only about the number of particles. Application: Geiger counter Another disadvantage is their relatively long dead time 200 to 300ms ERDIT Meeting, CERN 11-12 April 2013

Status & Challenges The technologies of these detectors are mature and commercially available. The challenges are for high rate applications where the polymerization effect is still an issue. ERDIT Meeting, CERN 11-12 April 2013

Scintillator Detectors Scintillators materials produce spark or scintillation of light when ionizing radiation passes through them. The operation is in 2 steps: Absorption of the incident radiation energy and production of the photons. Amplification of the light by a PMT or an APD They can be divided in 3 groups: inorganic Scintillators, organic Scintillators and gaseous Scintillators. ERDIT Meeting, CERN 11-12 April 2013

Inorganic Scintillators Applications Properties of some inorganic scintillators NaI(Tl), CsI are the most commonly used for ϫ-rays. (sizes up to 0.75m Dia, 0.25m thick). Used for all nuclide identification applications CaF2 (Eu) efficient for β particles and X-rays with low ϫ sensitivity. LiF/ZnS for neutron imaging with wavelength shifting-fiber detector Mterial λ(nm) ε(%) dec(μs) NaI(Tl) 410 100 0.23 CaF2(Eu) 435 50 0.94 CsI(Na) 420 80 0.63 CsI(Tl) 565 45 1.00 Bi4Ge3O12 480 8 0.3 CdWO4 530 20 0.9 6LiI(Eu) 470 30 NaI(Tl) is recommended for all nuclide identification applications because it provides the best currently available energy resolution for gamma rays in a room temperature detector that is relatively inexpensive and available in a wide variety of sizes. BGO is heavier and thereby has higher intrinsic efficiency at higher energies, useful for measuring the 2.6 MeV gamma ray associated with highly enriched Uranium (HEU). CsI has good light output but poorer resolution than NaI, however it can be used with electronics that provide very low power consumption for portable applications. ERDIT Meeting, CERN 11-12 April 2013

Organic Scintillators Properties of some organic scintillators Applications for crystal, liquid, plastic and gaseous scintillators Crystal have faster response time compared to inorganic faster timing resolution. Liquid scintillators are used in large volume to increase the efficiency and reduce ϫ/n ratio. Mixture of noble gases: lowϫ, short decay, Light output per MeV doesn’t depend on the charge or the mass of the particle. Suitable for heavy charged particles (α, fission fragments, …. Material λ(nm) ε(%) dec(ns) Anthracene 445 100 30 NE-102 385 65 2 NE-110 350-450 60 3 NE213 Pilot B 68 Pilot ϒ 64 Organic crystal scintillators are aromatic hydrocarbon compounds which contain benzene. Their luminescence typically decays within a few nanoseconds. They are very durable, but their response is anisotropic (which spoils energy resolution. Their luminescence typically decays within a few nanoseconds. They are very durable, but their response is anisotropic (which spoils energy resolution ERDIT Meeting, CERN 11-12 April 2013

Organic Scintillators Plastic scintillators Plastic scintillators have similar properties to those of liquid scintillators. They don’t need a container and can be machined in any size or shape and inert to water, air and many chemical. Applications include large area detector array for neutron measurements and ϫ-ray large area space telescope The advantages of plastic scintillators include fairly high light output and a relatively quick signal, with a decay time between 2‐4 nanoseconds, but perhaps the biggest advantage of plastic scintillators is their ability to be shaped ERDIT Meeting, CERN 11-12 April 2013

Scintillators: Status & challenges Future works will be focused on the light output conversion and gamma discrimination while maintaining a fast decay time. Transparent scintillators are attractive The phoswich detector (which measures low level of radiation in presence of considerable background) needs to be improved for neutron spectroscopy, CT and SPECT. Coincidence measurement in α/β/ϫ spectrometry ERDIT Meeting, CERN 11-12 April 2013

Semiconductors Operate like ionization chambers Si and Ge are the most used but CZT, HgI2 and CdTe are promising. Ge(HPGe, GeLi), Si have a very good energy resolution (for spectroscopy applications) but requires continuous cooling and are therefore bulky and expensive. CZT and HgI2 can operate at room temperature for Mossbauer spectroscopy with a limited energy resolution. ERDIT Meeting, CERN 11-12 April 2013

Semiconductors: Challenges Damages are seen with particle fluence in the order of 1012 (P/m2) for heavy ions and 1014 (α or n /m2) for both Si and Ge. Future directions will focus on improving the radiation damage on semiconductors. Diamond or SiC are viable candidates ERDIT Meeting, CERN 11-12 April 2013

Some IAEA Projects Active personal dosimeter Continuous air particle monitors Area monitoring and Environmental monitoring Foot and surface contamination monitoring Whole body counter Portal monitor and passive detection Coincidence and anticoincidence detection systems Nuclear medicine X-ray spectrometry Detection of Nuclear materials/non-proliferation issues Unmanned aerial vehicles for radiation detection Portable Gamma spectroscopy Activities in bold are related to our team research projects. ERDIT Meeting, CERN 11-12 April 2013

The Proposal for the UHVC Project To develop a multipurpose Ultra High Vacuum Chamber (UHVC) for applying simultaneously various complementary and advanced variants of X-Ray Spectrometry (XRS) techniques, including: Total Reflection X-ray Fluorescence Analysis (TXRF) Grazing Incidence XRF analysis (GIXRF) Near Edge X-ray Absorption Fine Structure (NEXAFS) X-ray Reflectometry (XRR) under different excitation modes: laboratory x-ray source synchrotron radiation charged particle beams ERDIT Meeting, CERN 11-12 April 2013

UHVC Instrumentation: Motorized 7-axis sample manipulator The sample manipulator includes: Four (4) linear stages (‘X’, ‘Y’, ‘Z’, ‘Diode’) Three (3) goniometers (‘Theta/2Theta’, ’Phi’) Aiming at moving the sample to be investigated in various directions/ orientations with respect to the exciting X-ray beam or/and with respect to the detectors. X-ray Detectors: Ultra Thin Window (UTW) Silicon Drift Detector (SDD, 30 mm2, FWHM <133 eV @ Mn-Ka, 75 eV @ C-Ka) and photodiodes (Si) The ‘Theta’ axis would provide an accuracy better than 0.15 mrad in the range of -5-110 degrees ERDIT Meeting, CERN 11-12 April 2013

“Backpack” Systems NaI(Tl) 0.347l; Android controlled PGIS-2-21 PicoEnvirotec Remediation: Gabon, Azerbaijan BGO 1x1.5”; Gamma Surveyor II GF Instruments Gabon, Austria LaBr (1x1.5”) + OSPREY Canberra Austria (Soil Erosion) We currently have 3 packpack systems ready for deployment by NSAL. These have been used on NSRW missions and for research in conjuction with NAFA-SWMNCL. In development is a custom suite based around CeBr detector, and a separate CeBr spectrometer has also been procured (awaiting delivery). Each detector uses different data acquisition methods and has independent GPS. ERDIT Meeting, CERN 11-12 April 2013

Aerial Radioactivity Monitoring Quad-/Hexa-copter drones Electric motors LiPo batteries Semi-autonomous GPS Autopilot Radiation monitoring Doserate (GM) Spectroscopic (e.g. CZT) Open source Example is Arduino controlled Shown is our existing quad-copter (centre left ) and the new hexa-copter (centre right and inset top left). The drones are powered by rechargeable LiPo batteries (one is attached on the quadcopter) for testing we’re using a 4 cell 14.8V 3000mAh battery. So far the battery life exceeds any flight test we have performed (<5mins) and with no detector attached. The quadcopter weighs 1.3 kg and the hexacopter 1.6kg, ready to fly cost is $799 and $999, respectively. These particular drones are arduino based, brand name is Arducopter. The selection of these particular drones was because they were based on arduino (an Italian project for an open-source single board microcontroller) which I also use/introduced for electronics training. Hence I wanted to demonstrate the power of the hardware I was teaching the fellows with. Three detectors are shown (centre bottom, inset bottom right). The brown tubes coupled to the blue boards are a custom built GM tube, using again arduino controllers. Also shown on top of the board at the bottom (silver square) is a GPS receiver. The same one is on both ‘copters. Adjacent beneath (bottom right inset) is a larger (0.5cm3) CZT detector for low energy gamma-ray spectroscopy. Above this to the left slightly is another CZT device, in this case an ultra slim probe. These devices are part of our programme for developing the detectors, readout and control systems for larger vehicles (where we would accompany the mission) and for the low cost programme (where we would send out kits, instructions, software and remote support). ERDIT Meeting, CERN 11-12 April 2013

Future tasks Establish a list of experiments in nuclear physics and determine in detail the detector requirements. Many other detectors not mentioned here are being used in nuclear physics. They include the MCP, the Anger camera, the SSND, the APD, the SiPM, the Cherenkov detectors, the calorimeters, etc ERDIT Meeting, CERN 11-12 April 2013

Conclusions Future efforts will focus on improving the timing/spatial resolution for some experiments while the efficiency and the energy resolution be important for the others. Thanks to all the NASL team. ERDIT Meeting, CERN 11-12 April 2013