HOUSTON, TEXAS1 Corrosion Control and Monitoring ENGINEERING SERVICES LP HOUSTON, TEXAS Engineering Specification.

Slides:



Advertisements
Similar presentations
Mitigation of AC Induced Voltage On Buried Metallic Pipelines
Advertisements

for Pipelines & Casings
EFCOG Electrical Improvement Project Electrical Hazards Awareness Briefing Excavation and Trenching Module 5.
Visit Us At Booth #306 J2 Engineering, Inc. J2 provides Construction and Environmental Services and is a verified Service-Disabled Veteran-Owned Small.
Corrosion and Cathodic Protection
Joe Killins & Associates, LLC Pipelines & Risk Based Management How Safe is Safe?
Bonding Requirements For Gas Piping Systems Bob Torbin October 2007
Student Book © 2004 Propane Education & Research CouncilPage Performing Pressure Tests on Gas Distribution Lines Gas personnel must understand.
Student Book © 2004 Propane Education & Research CouncilPage Installing Buried Distribution Lines Using Polyethylene Tubing and Mechanical.
Gas Transmission Pipelines
GTEC 2014 Fall Compliance Conference CATHODIC PROTECTION SYSTEMS Underground Fuel Tanks & Piping Owner Monitoring & Maintenance Requirements.
Presenter: Craig Woolhouse Sales Manager Elcometer Limited
Regional Sales Manager
Coatings – Directional Boring Tim Jenkins. Coatings – Directional Boring Design Considerations (data collection) Design Considerations (data collection)
Quality Service Providing Quality Performance.
Corrosion/Erosion PROCESS OUT OF CONTROL.
U.S. Department of Transportation Pipeline and Hazardous Materials Safety Administration Corrosion Control A PHMSA Perspective Pipeline Safety Trust Conference.
Control of DC and AC Interference on Pipelines
Cathodic Protection Presentation on Cathodic Protection System, at IOCL KBPL Kandla. Dt By Corrosion Matters Hyderabad An Advisory services.
Atmospheric Corrosion NiSource Exposed pipelines.
4.1.5 Student Book © 2004 Propane Education & Research CouncilPage Determining the Proper Corrosion Protection Systems for Underground ASME Tanks.
Purpose Power lines Equipment Assured Grounding GFCI Conclusion.
Student Book © 2004 Propane Education & Research CouncilPage Applying Protective Coatings to Storage Containers ASME tanks require proper.
ABC Chemical Complex1 Maintenance of DOT Regulated Valves ABC Company ABC Chemical Complex Engineering Specification.
BP, OQ & You. 2 Why do we have OQ? Walnut Creek 3 Bellingham Washington.
Reducing the Threat of Fuel Release from the Red Hill Fuel Storage Facility A Unique Engineering Challenge.
Basic Cathodic Protection Measurement and Monitoring- IR Considerations Western Regional Gas Conference 2008 Tempe, Arizona By Paul Sedlet, Accurate Corrosion.
NEPTUNE Power System Ground Return Electrodes Tim McGinnis & Colin Sandwith UW/APL.
WESTERN REGION GAS CONFERENCE AUGUST 21, 2012 CORROSION 101
Western Regional Gas Conference August 24, 2010 Distribution Integrity Management Programs (DIMP) Rule.
Electrical Safety in Construction. Objectives In this course, we will discuss the following: Common electrical hazards Standards relating to those hazards.
3.7.3 Student Book © 2004 Propane Education & Research CouncilPage Identifying Safe Handling Practices for Flammable and Combustible Liquids Injecting.
Presented by: Tony Serdenes, Greenman-Pedersen
HOUSTON, TEXAS1 Pipeline Repair ENGINEERING SERVICES LP HOUSTON, TEXAS Engineering Specification.
HOUSTON, TEXAS1 Maintenance of DOT Regulated Valves ENGINEERING SERVICES LP HOUSTON, TEXAS Engineering Specification.
Cathodic Protection Requirements for Military Projects.
Proper Use of Extension Cords
PIPELINE SPECIFICATIONS
Shipwrecks, Corrosion and Conservation Summary Slides PART 3 – Jack Dengate.
Active Corrosion Process Nisource – COH/CKY. Objectives  Understanding the terminology –Active Corrosion –& Suspected Areas of “Active Corrosion”  Developing.
Review of the operation scenarios and required manning of the activities P. Schnizer and L. Serio.
ICORR Technologies, Inc.
HOUSE WIRING Final Review. Electricity Electricity = flow of electrons Conductor= electricity passes thru easily - Metal, water, person Insulator = restricts.
Definition of Corrosion
CORROSION MITIGATION OF A PIPELINE
Cross Connection Survey Training
Materials Selection and Coatings
CHAPTER 2 Pipeline Coatings.
Basic Corrosion Theory
Maintenance of DOT Regulated Valves
PIPELINE SPECIFICATIONS
Electrical Equipment CSP uses conventional electrical equipment in the majority of areas All installations follow the mandatory electrical codes The.
Evaluation Techniques
Criteria for Cathodic Protection
Electrical Equipment CSP uses conventional electrical equipment in the majority of areas All installations follow the mandatory electrical codes The.
Personal Protective Equipment
From AS :   Part 4— Commissioning, operation and asset management
CHAPTER 6 Stray Current Interference.
Monitoring Cathodic Protection Effectiveness and Record keeping
Corrosion Control Must be addressed at the design stage
Safety Meeting Topics Standby Generator Safety
Corrosion Control and Monitoring
Field Testing for Shorted Casings
2019 AUCSC Fundamentals Session Jeff Didas – Matcor - Tucson, AZ
Corrosion Control and Monitoring
Gas Transmission Pipelines
Maintenance of DOT Regulated Valves
Presentation transcript:

HOUSTON, TEXAS1 Corrosion Control and Monitoring ENGINEERING SERVICES LP HOUSTON, TEXAS Engineering Specification

HOUSTON, TEXAS2 Corrosion Control & Monitoring u SCOPE –This Engineering Specification includes external and internal corrosion control and monitoring for DOT regulated pipelines. –Design, construction, construction inspection, construction acceptance, operation, and maintenance of DOT regulated pipelines are covered by this Engineering Specification.

HOUSTON, TEXAS3 Corrosion Control &Monitoring u GENERAL –All DOT regulated LCCC pipelines require protection from the environment. –Corrosive elements in the pipeline stream must be neutralized or the pipe material must be resistant to the stream.

HOUSTON, TEXAS4 Corrosion Control & Monitoring u Minimum requirements for corrosion control: –External Corrosion Control »Buried DOT regulated pipelines will be coated and cathodically protected –Internal Corrosion Control »Known corrosion rate based on historical data »Corrosion rate from a national standard data base »Data collected from laboratory prototype testing

HOUSTON, TEXAS5 Corrosion Control & Monitoring u Minimum requirements for corrosion control (Continued): –Above Ground External Corrosion Control »Coat with an approved system with resistance to the soil and internal fluid temperature

HOUSTON, TEXAS6 Corrosion Control & Monitoring u REFERENCES –NACE RP –Surface Preparation: »NACE No. 1, SSPC-SP 5, White Metal Blast Cleaning »NACE No. 2, SSPC-SP 10, Near White Metal Blast »NACE No. 3, SSPC-SP6, Commercial Blast »NACE No. 4, SSPC-SP 7, Brush-Off Blast

HOUSTON, TEXAS7 Corrosion Control & Monitoring u PERSONNEL REQUIREMENTS –Engineering design will be performed by a Corrosion Engineer with training and experience in the proposed corrosion control system. –Coating, lining, and painting inspection will be performed by an inspector with appropriate training and experience.

HOUSTON, TEXAS8 Corrosion Control & Monitoring u PERSONNEL REQUIREMENTS (Cont..) –Cathodic protection installations will be inspected by an inspector with training and experience in cathodic protection inspection. –Internal corrosion monitoring installations will be inspected by an inspector with training and experience in internal corrosion monitoring inspection.

HOUSTON, TEXAS9 Corrosion Control & Monitoring u DESIGN REQUIREMENTS, EXTERNAL –Cathodic Protection Criteria »Buried Onshore Pipelines: Pipe-to-soil potential equal to or more negative than volts referenced to copper-copper sulfate electrode and recorded immediately after current interruption (Instant-off potential). »Offshore Pipelines: Pipe-to-water potential equal to or more negative than volts referenced to a silver-silver chloride electrode with “instant off” potential reading.

HOUSTON, TEXAS10 Corrosion Control & Monitoring »Tank Bottoms: Steel-to-soil potential equal to or more negative than volts with a copper-copper sulfate half cell and “instant off” potential. »Maximum pipeline potential: Equal to or less than volts to a standard copper-copper sulfate half cell with the current temporarily interrupted.

HOUSTON, TEXAS11 Corrosion Control & Monitoring –Coating Requirements »New buried pipe sections shall be coated with one of the following types: u Fusion bonded epoxy u Coal tar epoxy u Polyolefin tape u Prefabricated films u Other coating systems approved by Central Engineering »Surface preparation shall be in accordance with manufacturer’s recommendation and Appendix B.

HOUSTON, TEXAS12 Corrosion Control & Monitoring u Methods Used for Cathodic Protection –Galvanic Anode Systems »Provide protection to the structure by the potential difference generated by the electrochemical reaction between the structure and the anode through a soil or water electrolyte. »Typically used in soil or water with resistivity less than 5000 ohm-cm.

HOUSTON, TEXAS13 Corrosion Control & Monitoring –Methods Used For Cathodic Protection (Cont) »Impressed Current Systems u Uses external source of DC power, usually an AC trans- former with an AC to DC rectifier, to provide the driving voltage to the structure to be protected. u Potential difference between the anode and the structure creates current flow from the anode into the soil and onto the pipeline. u Used when the soil resistivity exceeds 5000 ohm-cm and/or more than 5 amperes of impressed current are required.

HOUSTON, TEXAS14 Corrosion Control & Monitoring –Equipment »Galvanic Anode Systems u Anode: Magnesium onshore, Galvalum III offshore. u Junction box to connect leads from structure and anode. »Impressed Current Systems u DC transformer/rectifier (supplied as a unit). u Anode(s) with inert or low reactivity characteristics. u Terminal box with resistors to adjust current flow to each anode or anode string.

HOUSTON, TEXAS15 Corrosion Control & Monitoring –Miscellaneous »Install lightning arrestors. »Provide electrical isolation: Insulating flanges or spools. »Minimize interference with bonding stations. »Install test stations to measure potentials. »Complete the following documentation: u Bonding and/or anode bed data sheet. u Bonding station data sheet. u Test station data sheet.

HOUSTON, TEXAS16 Corrosion Control & Monitoring –Impact on Operating Equipment »Apply NEMA electrical-class safety requirements to all equipment associated with impressed current installations. »Install CP equipment in areas not requiring intrinsically safe design. »Locate anode beds to minimize effect on other structures and to minimize mechanical damage from foreign construction.

HOUSTON, TEXAS17 Corrosion Control & Monitoring »Perform interference testing on all equipment that may be damaged by the new CP installation. Testing shall include, but is not limited to, the following situations: u Pipelines crossing within 5 feet. u Metal Structures within 5 feet of the pipeline. u Metal Structures within 200 feet of the anode bed.

HOUSTON, TEXAS18 Corrosion Control & Monitoring –Impact on Operating Equipment »Design CP systems with capacity for current loss through interference bonds and future current loss due to coating deterioration. »Minimize casing installations for protection of the carrier pipe. Perform interference testing as shown in Company Corrosion Control & Monitoring Specification Appendix E. Provide bonding stations for each casing installation.

HOUSTON, TEXAS19 Corrosion Control & Monitoring u DESIGN REQUIREMENTS, INTERNAL –Corrosive chemicals in the pipeline stream »May reduce stream (liquid or gas) quality or »Cause general thinning or pitting attack »Shall be handled by one of the following methods: u Neutralization or removal of the corrosive chemicals. u Select a pipe material which is resistant. u Coat the internal surfaces of the pipe.

HOUSTON, TEXAS20 Corrosion Control & Monitoring –Design package will contain: »Provisions for upset/emergency conditions. »Recommended corrosion monitoring program. »Recommended corrosion monitoring equipment. »Installation of personnel safety devices and platforms required for safe performance of duties. »Pigging procedure when pigging facilities are included in the design package. »Compliance with regulations of local, state, and federal jurisdiction for pigging procedures.

HOUSTON, TEXAS21 Corrosion Control & Monitoring –Documentation Requirements »Determine thickness measurement locations (TML’s) based on the most probable locations for corrosion or erosion-corrosion damage. Select TML’s with the assistance of the Corrosion Engineer. »Collect baseline thickness readings on all new installations. »Install corrosion monitoring equipment where the “worst case” corrosion attack is expected. »Provide corrosion monitoring data sheets.

HOUSTON, TEXAS22 Corrosion Control & Monitoring u DESIGN REQUIREMENTS, ABOVE GROUND EXTERNAL –Coat with a coating system that is recom- mended for the environment. –Prepare surface in accordance with external- coating-system manufacturer’s recommendations. See Company Corrosion Control & Monitoring Specification Appendix B.

HOUSTON, TEXAS23 Corrosion Control & Monitoring u INSTALLATION –Quality Control, External Systems »Coatings u Qualified Inspector presence - 100%. u Field applied coating systems - 100% inspection. u Shop applied coating systems - 100% inspection. u Coating repairs - 100% inspection. u Protect all stored coating materials at the construction site from weather, particularly directly sunlight and heat.

HOUSTON, TEXAS24 Corrosion Control & Monitoring »Pad in the pipe trench u Inspect just prior to laying the pipe in the trench. u Remove all trash and construction debris. »Cables u Inspect upon receipt at job site to detect nicks and damage. u 100% inspection at the mill with proper mill cert.. u Avoid damaging cable insulation during installation. u Splice cables aboveground in terminal boxes. u Use non-conductive conduits for cable installation. u Make cathode cable connections aboveground, if possible. u Repair buried connection in accordance with the original coating manufacturer’s recommendations.

HOUSTON, TEXAS25 Corrosion Control & Monitoring –Transformer/Rectifier Systems »Install by a qualified electrician. »Test rectifier at maximum design load to assure the DC output meets the manufacturer’s specifications including the maximum AC ripple. »Calculate rectifier efficiency and record on the rectifier data sheet. »Verify the positive cable is attached to the anode bed and the negative cable is attached to the protected structure or pipe.

HOUSTON, TEXAS26 Corrosion Control & Monitoring »Miscellaneous Considerations u Inspect cables in terminal boxes to assure correct labels. u Verify test stations, bonding stations, and associated hardware for cathodic protection service. u Contact owners/operators of foreign pipelines to enable testing before and after new cathodic protection project commissioning. u Record base readings on the new pipeline or structure prior to cathodic protection system energizing. Record potentials at all interference bonds and test stations. u Energize system in small current increments and record potentials with each increase until protection is achieved. u Check bonding stations for interference problems. u File all commissioning data in the original equipment file.

HOUSTON, TEXAS27 Corrosion Control & Monitoring –Quality Control Requirements, Internal Surface »Inspect corrosion monitoring installations with the services of a qualified Corrosion Technician. »Take baseline data prior to pipeline commissioning. »Install lined pipelines per design. »Repair lining of field joints as recommended. »Install corrosion monitoring devices per design. »Complete electrical installations with qualified electricians. »Document commissioning information as a part of the original equipment file.

HOUSTON, TEXAS28 Corrosion Control & Monitoring –Quality Control Requirements, Internal Surface »Delay work initiation pending review of design package by coating inspector. »Protect coating material from weather. »Prepare surface for coating per manufacturer’s recommendation immediately before coating installation. »Follow manufacturer’s recommendation for dew point and humidity.

HOUSTON, TEXAS29 Corrosion Control & Monitoring u OPERATIONS –Perform cathodic protection surveys annually in accordance with Company CP procedure. –Monitor bonding and test stations annually. –Read and record rectifier output monthly with changes reported to the SR. Inspector for evaluation and action. –Correct deficiencies in a timely manner.

HOUSTON, TEXAS30 Corrosion Control & Monitoring u MAINTENANCE –Test rectifier stacks for proper performance annually. –Check anode bed resistance annually. –Check insulating flanges and spools annually. –Document all maintenance tests and add to the equipment file.

HOUSTON, TEXAS31 Corrosion Control & Monitoring Appendices u A - Coating Reference Index u B - Surface Preparation u C - Sample Data Sheets »Rectifier Data Sheet »Anode Bed Data Sheet »Galvanic Anode Data Sheet »Potential Survey Data Sheet u Predesign Testing