Chem. 133 – 3/12 Lecture. Announcements I HW 2.1 problem due today Quiz 3 also today Lab – Term Project Proposal due next Thursday Sign Up (see details.

Slides:



Advertisements
Similar presentations
Fluorescence Fluorescent corals.
Advertisements

Non-Instrumental Methods
SPECTROSCOPY.
Molecular Fluorescence Spectroscopy
Chapter Eleven Ultraviolet-Visible Spectrophotometry
Spectrophotometry Chapter 17, Harris
Chem. 133 – 4/1 Lecture. Announcements I Lab –Returning Term Project Proposals (I expect to be getting boxes of supplies ready) –Returning Set 2 Period.
Chem. 133 – 3/17 Lecture. Announcements Pass back HW + Quiz Lab –Term Project Proposal due Thursday –Next Lab Report also due Thursday Today’s Lecture.
Spectroscopy 1: Rotational and Vibrational Spectra CHAPTER 13.
Lecture 30 11/14/05. Spectrophotometry Properties of Light h = x J-s c = 3.00 x 10 8 m/s.
Spectrophotometric Analysis
Outline Final Comments on Titrations/Equilibria Titration of Base with a strong acid End-point detection Choice of indicators Titration Curve method Start.
Introduction to Spectrophotometry
Chem. 133 – 3/10 Lecture. Announcements I Exam 1 –Average (66.5) + Distribution –A little worse than average Today’s Lecture –Electrochemistry (just questions)
Absorbance of Electromagnetic Radiation
INTRO TO SPECTROSCOPIC METHODS (Chapter 6 continued ) Quantum-Mechanical Properties Of Light Photoelectric Effect Photoelectric Effect Energy States of.
Lecture 3 INFRARED SPECTROMETRY
Chapter 13 An Introduction to Ultraviolet/Visible Molecular Absorption Spectrometry Absorption measurements based upon ultraviolet and visible radiation.
Spectroscopy (continued) Last time we discussed what spectroscopy was, and how we could use the interaction of light with atoms and molecules to measure.
Non-Instrumental Methods
Introduction to Instrumental Analysis - Spectrophotometry
Spectrochemical Analysis. Electromagnetic Radiation Energy propagated by an electromagnetic field, having both particle and wave nature.
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 18 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
Introduction to Spectrochemical Methods
Spectrophotometer Prof.Dr. Moustafa M. Mohamed Vice Dean Faculty of Allied Medical Science Pharos University in Alexandria, EGYPT.
10/11/ ENGINEERING RESEARCH CENTER FOR S TRUCTURED O RGANIC P ARTICULATE S YSTEMS RUTGERS UNIVERSITY PURDUE UNIVERSITY NEW JERSEY INSTITUTE OF TECHNOLOGY.
19 장 Fundamentals of Spectrophotometry Fundamentals of Spectrophotometry –19-1Properties of Light –19-2Absorption of Light –19-3 The Spectrophotometer.
Chem. 31 – 4/1 Lecture.
Fluorometric Analysis
Chem. 31 – 3/30 Lecture. Announcements I Additional Problem due Wed (along with quiz) No Lab Tomorrow (Campus closed for Cesar Chavez holliday) Exam 2.
Chapter 13 An Introduction to Ultraviolet- Visible Molecular Absorption Spectrometry.
Chapter 15 Molecular Luminescence Spectrometry Three types of Luminescence methods are: (i) molecular fluorescence (ii) phosphorescence (iii) chemiluminescence.
Microplate reader spectrophotometer. The Beer-Lambert Law A=abc Now let us look at the Beer-Lambert law and explore it's significance. A is absorbance.
Lecture 2 INTRODUCTION TO SPECTROMETRIC METHODS Copyright ©The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
Fluorescence Spectroscopy
Spectrophotometry.
Chapter 18 Spectroscopy. Interaction of Light and Matter Light = photons waves Oscillating electric and magnetic fields Frequency ( ) - number of full.
Chapter 6 An Introduction to Spectrometric Methods Spectrometric methods are a large group of analytical methods that are based on atomic and molecular.
Introduction to Spectroscopic Methods of Analysis (part 2)
Introduction to Spectrophotometry
1 UV-Vis Absorption Spectroscopy Lecture Measurement of Transmittance and Absorbance: The power of the beam transmitted by the analyte solution.
Introduction to Spectrochemical Methods
Visible Spectroscopy Electromagnetic Radiation: Light & Color.
Spectrophotometer.
SPECTROPHOTOMETRY. Principle : there is interaction between the light and sample particle, spectrophotometer is employed to measure the amount of light.
CLS 332 CLINICAL INSTRUMENTAL ANALYSIS. A VISIBLE ABSORPTION SPECTROMETER.
Outline Start Chapter 18 Spectroscopy and Quantitative Analysis.
1 Atomic Emission Spectroscopy Molecular Absorption Spectroscopy Lecture 21.
Ch 10 Pages ; Lecture 24 – Introduction to Spectroscopy.
1.1 What’s electromagnetic radiation
Summary: (Last lecture) Absorption spectroscopy definition electromagnetic spectroscopy matter absorption spectroscopy fundamental terms (transmittance,
Lab (9): Measurement of colors Spectrophotometry Analytical biochemistry lab KAU-Biochemistry dep. Nouf Alshareef
Chem. 133 – 3/29 Lecture. Announcements I Grading – Set 2 lab reports (return?) – Term project proposals (still working on) – UV-Visible seemed to work.
Introduction to Spectrochemical Methods
Molecular Fluorescence Spectroscopy
Lab1 A VISIBLE ABSORPTION SPECTROMETER. -One of the simplest and most widely used methods to determine concentration of a substance in solution -Measures.
Chem. 31 – 6/30 Lecture. Announcements I Lab –Supplement to Co/Cr Lab has been posted online AP2.2 due Quiz 4 today No Class on Monday (July 4 th )
Chem. 133 – 3/16 Lecture.
Chem. 133 – 3/9 Lecture.
Lab1 A VISIBLE ABSORPTION SPECTROMETER
Chem. 133 – 3/14 Lecture.
Non-Instrumental Methods
Chem. 31 – 10/25 Lecture.
Spectrophotometer Dr . S. Jayakumar.
Light and Matter Main Concept:
SPECTROPHOTOMETRY Applied Chemistry.
Spectrophotometry A method to determine concentration of a species exploiting the absorption of EMR.
A SEMINAR ON Ultraviolet-Visible Spectroscopy
Spectrophotometric Analysis
Presentation transcript:

Chem. 133 – 3/12 Lecture

Announcements I HW 2.1 problem due today Quiz 3 also today Lab – Term Project Proposal due next Thursday Sign Up (see details in main office) to Meet With Review Committee (Mon. 3-3:15) Change in Office Location (starting after Spring Break): New Office = Sequoia 528 (probably for rest of semester)

Announcements II Today’s Lecture –Chapter 17: (Basic Spectroscopic Theory) Fluorescence/Phosphorescence Spectral Interpretation Beer’s Law –Chapter 18: Spectrometer Instrumentation Light Sources

Spectroscopy Questions 1.Light observed in an experiment is found to have a wave number of 18,321 cm -1. What is the wavelength (in nm), frequency (in Hz), and energy (in J) of this light? What region of the EM spectrum does it belong to? What type of transition could have caused it? [did last time] 2.If the above wave number was in a vacuum, how will the wave number, the wavelength, the frequency and the speed change if that light enters water (which has a higher refractive index)? 3.Is a lamp needed for chemiluminescence spectroscopy? Explain. 4.Light associated with wavelengths in the 0.1 to 1.0 Å region may be either X-rays or  -rays. What determines this? 5.What type of transducers could be used with photoionization to make a detector?

Spectroscopy Transitions in Fluorescence and Phosphorescence Absorption of light leads to transition to excited electronic state Decay to lowest vibrational state (collisional deactivation) Transition to ground electronic state (fluorescence) or Intersystem crossing (phosphorescence) and then transition to ground state Phosphorescence is usually at lower energy (due to lower paired spin energy levels) and less probable Ground Electronic State Excited Electronic State higher vibrational states Triplet State (paired spin)

Spectroscopy Interpreting Spectra Major Components –wavelength (of maximum absorption) – related to energy of transition –width of peak – related to energy range of states –complexity of spectrum – related to number of possible transition states –absorptivity – related to probability of transition (beyond scope of class) A (nm) AoAo A* EE  EE

Absorption Based Measurements Beer’s Law Light intensity in = P o Light intensity out = P Transmittance = T = P/P o Absorbance = A = -logT Light source Absorbance used because it is proportional to concentration A = εbC Where ε = molar absorptivity and b = path length (usually in cm) and C = concentration (M) b ε = constant for given compound at specific λ value sample in cuvette Note: P o and P usually measured differently P o (for blank) P (for sample)

Beer’s Law – Specific Example A compound has a molar absorptivity of 320 M -1 cm -1 and a cell with path length of 0.5 cm is used. If the maximum observable transmittance is 0.995, what is the minimum detectable concentration for the compound?

Beer’s Law – Best Region for Absorption Measurements Determine the Best Region for Most Precise Quantitative Absorption Measurements if Uncertainty in Transmittance is constant A % uncertainty 02 High A values - Poor precision due to little light reaching detector Low A values – poor precision due to small change in light

Beer’s Law – Deviations to Beer’s Law A. Real Deviations - Occur at higher C - Solute – solute interactions become important - Also absorption = f(refractive index)

Beer’s Law – Deviations to Beer’s Law B. Apparent Deviations 1. More than one chemical species Example: indicator (HIn) HIn ↔ H + + In - Beer’s law applies for HIn and In - species individually: A HIn = ε(HIn)b[HIn] & A In- = ε(In - )b[In - ] But if ε(HIn) ≠ ε(In - ), no “Net” Beer’s law applies A meas ≠ ε(HIn) total b[HIn] total Standard prepared from dilution of HIn will have [In - ]/[HIn] depend on [HIn] total In example, ε(In - ) = 300 M -1 cm -1 ε(HIn) = 20 M -1 cm -1 ; pK a = 4.0

Beer’s Law – Deviations to Beer’s Law More than one chemical species: Solutions to non-linearity problem 1)Buffer solution so that [In - ]/[HIn] = const. 2)Choose λ so ε(In - ) = ε(HIn)

Beer’s Law – Deviations to Beer’s Law B. Apparent Deviations 2. More than one wavelength ε(λ1) ≠ ε(λ2) λ1λ1 λ2λ2 Example where ε(λ1) = 3*ε(λ2) line shows expectation where ε(λ1) = ε(λ2) = average value Deviations are largest for large A A λ

Beer’s Law – Deviations to Beer’s Law More than one wavelength - continued When is it a problem? a) When polychromatic (white) light is used b) When dε/dλ is large (best to use absoprtion maxima) and Δλ is not small (Δλ is the range of wavelengths passed to sample) c) When monochromator emits stray light d) More serious at high A values

Luminescence Spectroscopy Advantages to Luminescence Spectroscopy 1. Greater Selectivity (most compounds do not efficiently fluoresce) 2. Greater Sensitivity – does not depend on difference in signal; with sensitive light detectors, low level light detection possible Absorption of light 95% transparent (equiv. to A = 0.022) Weak light in black background Emission of light

Chapter 19 - Spectrometers Main Components: 1) Light Source (produces light in right wavelength range) 2) Wavelength Descriminator (allows determination of signal at each wavelength) 3) Sample (in sample container) 4) Light Transducer (converts light intensity to electrical signal) 5 )Electronics (Data processing, storage and display) Example: Simple Absorption Spectrophotometer Light Source (e.g tungsten lamp) Monochromator Sample detector (e.g. photodiode) Electronics single out

Spectrometers Some times you have to think creatively to get all the components. Example NMR spectrometer: Light source = antenna (for exciting sample, and sample re-emission) Light transducer = antenna Electronics = A/D board (plus many other components) Wavelength descriminator = Fourier Transformation Radio Frequency Signal Generator Antenna A/D Board Fourier Transformed Data

Spectrometers – Fluorescence/Phosphorescence Fluorescence Spectrometers –Need two wavelength descriminators –Emission light usually at 90 deg. from excitation light –Can pulse light to discriminate against various emissions (based on different decay times for different processes) –Normally more intense light and more sensitive detector than absorption measurements since these improve sensitivity lamp Excitation monochromator sample Emission monochromator Light detector

Absorption Spectrometers A.Sensitivity based on differentiation of light levels (P vs P 0 ) so stable (or compensated) sources and detectors are more important B.Dual beam instruments account for drifts in light intensity or detector response Light Source (tungsten lamp) Monochromator Sample Electronics chopper or beam splitter Reference detector

Spectrometers – Specific Components Light Sources A.Continuous Sources - General 1)Provide light over a distribution of wavelengths 2)Needed for multi-purpose instruments that read over range of wavelengths 3)Sources are usually limited to wavelength ranges (e.g. D 2 source for UV)

Spectrometers – Light Sources A.Continuous Sources – Specific 1)For visible through infrared, sources are “blackbody” emitters 2)For UV light, discharge lamps (e.g. deuterium) are more common (production of light through charged particle collision excitation) 3)Similar light sources (based on charged particle collisions) are used for X-rays and for higher intensity lamps used for fluorescence 4)For radio waves, light generated by putting AC signal on bare wire (antenna). Wide range of AC frequencies will produce a broad band of wavelengths. UVVisIR high T low T (max shifted to larger ) intensity