Evaluation and Comparison of Fracture Behavior of Selected Nuclear Graphite by Small Size SENB Specimens Se-Hwan Chi. Ph. D. 15 th International Nuclear.

Slides:



Advertisements
Similar presentations
Evaluation of Fracture toughness of fine- and coarse-grain graphite
Advertisements

Material Performance Centre University of Manchester UNTF 2010 Andrew Wasylyk UNTF 2010 Assessment of Ductile Tearing and Plastic collapse in 304 SS Andrew.
Bay Zoltán Foundation for Applied Research Institute for Logistics and Production Systems BAY-LOGI Temperature dependence of Beremin-modell parameters.
Numerical Analysis for Influence of Cascade Solidity on the Performances of Cavitating Inducers Xiaojun Li Research Center of Fluid.
Investigation of Proton Irradiation-Induced Creep of Ultrafine Grain Graphite Anne A. Campbell & Gary S. Was University of Michigan Research Supported.
Mechanism of Proton Irradiation-Induced Creep of Ultra-Fine Grain Graphite ZXF-5Q A.A. Campbell & G.S. Was INGSM-15 September 18, 2014 Research Supported.
14 th International Nuclear Graphite Specialist Meeting (INGSM ̵ 14 ) September 16-18, 2013, Hilton Seattle, Washington State, USA Oxidation Effects on.
The AGC-1 Creep Experiment - Results and Analysis INGSM-15 HANGZHOU, CHINA Sept 15-18, 2015 Tim Burchell Fusion Materials & Nuclear Structures Group Materials.
Fracture Specimen To Visualize whether a crack of given length in a material of known fracture toughness is dangerous, because it will propagate to given.
Chapter 9 Fracture Testing
An Experimental Study and Fatigue Damage Model for Fretting Fatigue
Design of Machine Elements
14 th International Nuclear Graphite Specialist Meeting (INGSM ̵ 14 ) September 16-18, 2013, Hilton Seattle, Washington State, USA Load relaxation and.
RaDIATE Progress Meeting, May 2013 Graphite progress update BJ Marsden and G Hall Nuclear Graphite Research Group, School of MACE, The University of Manchester.
1 ASTM : American Society of Testing and Materials.
Presented by Robert Hurlston UNTF Conference 2011 Characterisation of the Effect of Residual Stress on Brittle Fracture in Pressure Vessel Steel.
Engineering materials lecture #14
Tim Burchell Oak Ridge National Laboratory
API - WI 2348 Methodology to provide Mechanical Assurance in DCB test
The Pre-Irradiation Examination of Small Specimens for a High Temperature HFIR Irradiation Capsule Tim Burchell, Joel McDuffee and Ken Thoms Oak Ridge.
TOKAI CARBON CO., LTD. Global Leader of Carbon Materials Radiation Effect Study on Tokai Carbon Nuclear Grade Graphite M. Fechter and Y. Katoh Oak Ridge.
Fatigue Analysis of JPCP With Transverse Surface Crack Introduction Experimental Design Conclusions It has been known that surface edge crack of JPCP (Joint.
Small-scale Approaches to Evaluate the Mechanical Properties of Quasi-brittle Reactor Core Graphite 1 Dong Liu, 1 Peter Heard, 2 Soheil Nakhodchi, 1,3.
Size Effect on the Fracture Properties of Nuclear Graphite Gyanender Singh, Haiyan Li and Alex Fok University of Minnesota.
Specimen Size Effects in the Determination of Nuclear Grade Graphite Thermal Diffusivity ASTM D02F000 Symposium on Graphite Testing for Nuclear.
Damage tolerance of adhesively bonded structures Background Adhesive bonding promises to allow the design of lighter weight structures. Before adhesive.
2009 ASME Wind Energy Symposium Static and Fatigue Testing of Thick Adhesive Joints for Wind Turbine Blades Daniel Samborsky, Aaron Sears, John Mandell,
Japan-US Workshop held at San Diego on April 6-7, 2002 How can we keep structural integrity of the first wall having micro cracks? R. Kurihara JAERI-Naka.
Jiangyu Li, University of Washington Lecture 21 Fracture Mechanics Mechanical Behavior of Materials Section Jiangyu Li University of Washington.
CHAPTER 9: MECHANICAL FAILURE
Fatigue Failure Through Bending David Burnette ME 498.
Mechanical characterization of lead- free solder joints J. Cugnoni*, A. Mellal*, Th. J. Pr. J. Botsis* * LMAF / EPFL EMPA Switzerland.
Small specimen testing – ASTM approach M P Metcalfe ASTM Symposium on Graphite Testing for Nuclear Applications: The Significance of Test Specimen Volume.
ASPECTS OF MATERIALS FAILURE
Copyright © Toyo Tanso Co., Ltd. All Rights Reserved TECS Irradiation Program for IG-110 and IG-430 Graphite for Evaluation of High Fluence Behavior.
The INNOGRAPH-1C low dose irradiation experiment extending the HTR graphite materials properties curves at 750°C Maurits Heijna INGSM September 2014.
Optimization of pocket design for extrusion with minimal defects Kathirgamanathan, P., Neitzert, T.
Vacuum, Surfaces & Coatings Group Technology Department Glassy Carbon Tests at HiRadMat 14 March 2014 C. Garion2 Outline: Introduction Context: Transparent.
FAST NEUTRON FLUX EFFECT ON VVER RPV’s LIFETIME ASSESSMENT
Engineering Doctorate – Nuclear Materials Development of Advanced Defect Assessment Methods Involving Weld Residual Stresses If using an image in the.
Orynyak I.V., Borodii M.V., Batura A.S. IPS NASU Pisarenko’ Institute for Problems of Strength, Kyiv, Ukraine National Academy of Sciences of Ukraine Pisarenko’
Bay Zoltán Foundation for Applied Reseach Institute for Logistics and Production Systems BAY-LOGI Integrity Assessment of Dissimilar Metal Welds BAY-LOGI.
Irradiation Effects in Graphite – from the Nano- to the Mille- Metric Scale Tim Burchell Distinguished R & D Staff Member Fusion Materials & Nuclear Structures.
The scaling of the strength of nuclear graphite Statistical aspects and Implications for testing Chris Wheatley.
ORNL is managed by UT-Battelle for the US Department of Energy Annealing Studies of Irradiated HOPG using X-ray Measurements Nidia C. Gallego Melanie J.
ORNL is managed by UT-Battelle for the US Department of Energy Effects of Neutron Irradiation in IG-110 Y. Katoh, M. Snead, A.A. Campbell Oak Ridge National.
Week 4 Fracture, Toughness, Fatigue, and Creep
Dimensional Change of Isotropic Graphite under Heavy Ion-Irradiation Sosuke Kondo Makoto Nonaka Tatsuya Hinoki Kyoto University SEP15-18, 2013 INGSM-14.
Hot Explosive Consolidated Nanostructured Ta-Al Composites
Tacis 2.02/95 on VVER 440 RPV Integrity TACIS Project: R8.01/98 – TRANSLATION, EDITING AND DIFFUSION OF DOCUMENTS (Result Dissemination) Tacis R2.02/95,
Exam 2 Grade Distribution. Stress-strain behavior (Room T): Ideal vs Real Materials TS
The High- Temperature HTV Graphite Irradiation Capsule for the High Flux Isotope Reactor at Oak Ridge National Laboratory J.L. McDuffee, T.D. Burchell,
Reactor pressure vessels of WWER (materials and technology) Janovec, J
Problems 1. A large plate is fabricated from a steel alloy that has a plane strain fracture toughness of 82.4MPa√m. If, during service use, the plate is.
Week 4 Fracture, Toughness, Fatigue, and Creep
Date of download: 5/31/2016 Copyright © ASME. All rights reserved. From: Fatigue Limit Prediction of the Matrix of 17-4PH Stainless Steel Based on Small.
ISSUES TO ADDRESS... How do flaws in a material initiate failure? How is fracture resistance quantified; how do different material classes compare? How.
Microstructural development of HOPG under ion-irradiation ○ Makoto Nonaka 1, Sosuke Kondo 2 and Tatsuya Hinoki 2 1 Graduate school of Energy Science, Kyoto.
A. K. Mallik and D. Basu Central Glass and Ceramic Research Institute, Kolkata Effect of processing technologies on grain size and mechanical properties.
CEA/DEN/DM2S/SEMT/LISN
Threshold stress intensity factor for hydrogen assisted cracking of Cr-Mo steel used as stationary storage buffer of a hydrogen refuelling station Takuya.
Ignacio Aviles Santillana
A. R. Raffray, J. Pulsifer, M. S. Tillack, X. Wang
Doç.Dr.M.Evren Toygar, DEÜ
Milan Brumovsky, Milos Kytka, Milan Marek, Petr Novosad
Natural Ceramic Membrane Filter for Water Purification
Determination of Fracture Toughness
Mechanics of Materials Lab
1/18/2019 6:28 AM C h a p t e r 8 Failure Dr. Mohammad Abuhaiba, PE.
Mechanical Failure(파괴)
Presentation transcript:

Evaluation and Comparison of Fracture Behavior of Selected Nuclear Graphite by Small Size SENB Specimens Se-Hwan Chi. Ph. D. 15 th International Nuclear Graphite Specialist Meeting (INGSM-15), September 15-18, 2014, Hangzhou, China NHDD Project (Nuclear Graphite Study), KAERI

Content 1.Background 2.Materials, Specimen, Test Jig 3.Fracture Toughness Testing and K IC, G-Δa Determination 4. Results 4.1 Specimen size effects on K IC and G-Δa of selected nuclear graphite grades 4.2 Comparison of Fracture Behavior of selected nuclear graphite grades. 5. Conclusion.

1.Background o Graphite core components in HTGR experience dimensional, mechanical, physical property changes owing to neutron irradiation and oxidation during operation resulting in an increase in fracture probability of the components.

For safety, monitoring and reflecting the mechanical property change of the core components on reactor operating condition are important as seen in the PWR RPV surveillance program. Surveillance Program of Core Materials PWR Limited capsule space for surveillance specimens requires small volume specimen and small specimen test techniques

Small specimen test techniques Various kinds of small specimens and small specimen test techniques are well developed in PWR technology

In HTGR, while limited space for surveillance specimens also needs graphite small specimen and small specimen test techniques as in PWR, related study and developments are progressing and further studies are required * *ASTM Symposium on Graphite Testing for Nuclear Applications: the Significance of Test Specimen Volume and Geometry and the Statistical Significance of Test Specime n Population (Sept , 2013 Hilton Seatle, Seatle, Washington, USA) HTTR (Japan) Surveillance Program of Core Materials No guide on strength measurements yet ! HTGR

Background / Purpose of Study In this study, the fracture toughness (K IC ) and G-Δa behavior of selected nuclear graphite grades were determined by small size fracture toughness specimens in size of 50.0 x 10.0 x 4.0 (4T) mm and 52 x 12 x 6.5 mm (6.5T)* based on a new ASTM fracture toughness testing procedure, ASTM D **. Obtained results ((K IC ) and G-Δa) were discussed in view from specimen size and microstructure of the grades. * The 4T and 6.5T specimen correspond to 1/15 (6.5T) and 1/30 (4T) of the ASTM D recommendation ** ASTM D The Standard Test Method for the Determination of Fracture Toughness of Graphite at Ambient Temperature

2. Materials, Specimen and Testing Fixture IG-110IG-430PCEANBG-17NBG-18NBG-25 Grain Size ( ㎛ ) Max. 800 Max: 1, Forming MethodIso-static Extrusion Vibration molding Iso-static Number of Specimen * 4T1310 acacacac T

2. Materials, Specimen and Testing Fixture Notch depth: 1.6 mm, Angle: 30° (EDM) Loading Rate: 0.1 mm/min

3. Fracture Toughness Testing and K IC, G-Δa Determination - g (a/W) for S/W = 8 Load-Displacement curve (IG-430) (NBG-18)

G-Δa Curve C n = D n /P n C n : Compliance for the point n (m/N) D n : displacement for the point n (m) P n : loading force for the point n (N). Initial Crack length, a o = notch depth a n = a n-1 + [(W-a n-1 )/2*((C n –C n-1 )/C n-1 )] G(a n ) = P 2 /2B*δC/δa [J/m 2 ], δC= C n – C n-1, δa= a n - a n-1 G-Δa, where Δa = a n – a 0

4. Results/Discussion 4.1 K IC MPa(m) 1/2 (1) M. Eto, et al, Int. Sym. On Carbon (1990), 8 type of specimens. (2) S. Fazluddin and B. Rand (2002, Univ. of Leeds), TB: 100 x 10 x 12, CT: 50 x 48 x 10 (3) Haiyan Li, CARBON (2013) 46, TB: 45 x 10 x 5 mm. (4) T. D Burchell, Proc. HTR2012 (2012), TB: 50 x 6 x 6 mm IG-110IG-430 NBG- 2 5-a NBG- 25-c NBG- 17-a NBG- 17-c NBG- 18-a NBG- 18-c PCEA-aPCEA-c K IC [MPa (m) 1/2 ] 4T 0.76 ± ± ± ± ± ± ± ± ± ± T 0.78 ± ± ± ± ± ± ± ± ±0.04 Ref (1) (2) 1.27 (3) ± ± (4) 0.941± (4)

4. Results/Discussion Observation 1.K IC tends to increases with specimen size 2.Observed anisotropy in K IC except IG-110 and Observed smaller value for IG-110 and larger value for NBG-18 and PCEA 4.1 K IC

4. Results/Discussion 4.2 G-Δa (4T )

4. Results/Discussion 4.2 G-Δa (6.5T)

4. Results/Discussion 4.2 G-Δa (Grade) 6.5T

4.3 Analysis of G-Δa Curve Based on the corresponding G and Δa of the intersection point A and B, the G IC, Δa, stable crack growth length to initial ligament (SCL)(%), an increase in ΔG during stable crack growth against G IC, i.e.,(G B -G A ) 100/ G IC, and stable strain energy release rate (ΔG B-A / Δa B-A ) were determined and compared. G IC A B 4. Results/Discussion

G IC A B 750 J/m J/m mm 2.06 mm ΔG = ( )/750 J.m 2 = 237 % SCL=100*( )/3.9 = 46 % Determination of SCL and Δ G

4. Results/Discussion 4.4 G-Δa Analysis Results IG-110IG-430 NBG- 2 5-a NBG- 25-c NBG- 17-a NBG- 17-c NBG- 18-a NBG- 18-c PCEA - a PCEA - c G IC [J/m 2 ], Δa (mm) 4T ΔaΔa T ΔaΔa SCL (%) 4T T ΔG (%) 4T 90 (133) 150 (120) 175 (175) 99 (85) 175 (100) 292 (167) 400 (172) 375 (225) 404 (248) 225 (100) 6.5T 225 (112) 575 (192) 600 (200) 1435 (208) 1310 (190) 1400 (175) 878 (157) 1775 (237) 1455 (217) (ΔG B-A / Δa B-A ) J/m 3 4T ? 6.5T ?

4.5 Comparison of G-Δa curves G- Δa from the extruded (or vibration molded) medium particle size grades is higher than the iso-molded fine particle size grades.

4. Observation 1.More or less smaller value due to small dimension 2.Observed anisotropy in K IC except IG-110 and Observed the smallest value for IG-110, the largest value for NBG G IC : NBG-17, 18, PCEA > IG-110, -430, NBG Differences between the fine grain, isostatic molding and medium grain, vibration molded or extruded in G-Δa “global behavior” is far larger and apparent than the differences in “local parameter” K IC. 6. No large differences in SCL. 7. No correlation between the K IC and G-Δa.

The results show that, though the K IC value from 6.5T was largely a little higher than the K IC from 4T for 2-28%, the 6.5 T K IC values appear a little smaller (15-30 % for IG-110, NBG-18) or larger (12.0 – 15.6 % for PCEA) than the reported values from larger size specimens. Overall, the K IC and G IC from the extruded (or vibration molded) medium particle size grades were a little higher than the iso-molded fine particle size grades. Differences in G IC were larger than the differences in K IC between grades. While the changes in K IC were small or negligible, a large increase in the G IC was observed with increasing specimen size from 4T to 6.5T. Detailed analysis of G-Δa curves, showed that, on average, SCL was 53% and 44%, and ΔG was 152.5% and 187.5% for 4T and 6.5T specimens, respectively. Present results show that both the local (K IC ) and gross (G) fracture characteristics of the Extruded (or vibration molded) medium particle size grades may largely be better than the iso-molded fine particle size grades, and the fracture parameter G seems to be appropriate in describing the fracture characteristics of nuclear graphite after crack initiation. 5. Summary

23 Surface Filometry (Model: Dektak 150) IG-110NBG-18 G-Δa curves will be compared with surface filometry measurements

NBG-18 IG-430