E. Norbeck U. IowaFast Gas Detector APR 05 Tampa1 Small Fast Gas Detector for High-Energy Electrons E. Norbeck, J.E. Olson, and Y. Onel University of Iowa.

Slides:



Advertisements
Similar presentations
General Characteristics of Gas Detectors
Advertisements

GM COUNTER.
Drift velocity Adding polyatomic molecules (e.g. CH4 or CO2) to noble gases reduces electron instantaneous velocity; this cools electrons to a region where.
Radiation Detectors / Particle Detectors
1 Sep. 19, 2006Changguo Lu, Princeton University Induced signal in RPC, Configuration of the double gap RPC and Grouping of the strips Changguo Lu Princeton.
Prototype TPC Tests C. Lu 12/9/98 V = 0. Gas gain test for the low pressure chamber The chamber is constructed with the following parameters: D anode.
Directional Detectors and Digital Calorimeters Ed Norbeck and Yasar Onel University of Iowa For the 25 th Winter Workshop on Nuclear Dynamics Big Sky,
Proportional Counters
Ionization. Measuring Ions A beam of charged particles will ionize gas. –Particle energy E –Chamber area A An applied field will cause ions and electrons.
Slide 1 Diamonds in Flash Steve Schnetzer Rd42 Collaboration Meeting May 14.
Detectors. Measuring Ions  A beam of charged particles will ionize gas. Particle energy E Chamber area A  An applied field will cause ions and electrons.
Position sensing in a GEM from charge dispersion on a resistive anode Bob Carnegie, Madhu Dixit, Steve Kennedy, Jean-Pierre Martin, Hans Mes, Ernie Neuheimer,
Mauro Raggi Status report on the new charged hodoscope for P326 Mauro Raggi for the HODO working group Perugia – Firenze 07/09/2005.
Performances of a pixel ionization chamber to monitor a voxel scan hadron beam A.Boriano 3, F.Bourhaleb 2,3, R. Cirio 3, M. Donetti 2,3, F. Marchetto 3,
Type of Material: Instrumentation Review
1 Microstrip PSD detectors C. Fermon, V. Wintenberger, G. Francinet, F. Ott, Laboratoire Léon Brillouin CEA/CNRS Saclay.
Rad Hard Active Media for Calorimeters E. Norbeck, J.E. Olson, A. Moeller, and Y. Onel University of Iowa PPAC Čerenkov Liquid with Tungsten metal.
Energy Resolution of a Parallel- Plate-Avalanche-Chamber Kausteya Roy Professors E. Norbeck and Y. Onel.
1 Semiconductor Detectors  It may be that when this class is taught 10 years on, we may only study semiconductor detectors  In general, silicon provides.
 Devices that can store electric charge are called capacitors.  Capacitors consist of 2 conducting plates separated by a small distance containing an.
C.Woody, PHENIX Upgrades, 11/10/00 A TPC for PHENIX ?? No, surely you must mean for STAR…. PHENIX, really …. ??? You must be NUTS !!! Well, wait a minute...
Fast Detectors for Medical and Particle Physics Applications Wilfried Vogel Hamamatsu Photonics France March 8, 2007.
FISICA AMBIENTALE 1 Radioattività: misure 1 Lezioni Marie Curie.
Tools for Nuclear & Particle Physics Experimental Background.
PHENIX RPC in China Li Ye Shouyang Hu Xiaomei LI China Institute of Atomic Energy
NEW COMMENTS TO ILC BEAM ENERGY MEASUREMENTS BASED ON SYNCHROTRON RADIATION FROM MAGNETIC SPECTROMETER E.Syresin, B. Zalikhanov-DLNP, JINR R. Makarov-MSU.
TIDE TESTS AT GDD LAB M. Casiraghi and F. Vasi. New detector configuration Low pressure chamber anode.
Glass Resistive Plate Chambers
Instrumentation Review. Direct and Indirect Ionization Direct - Charge particles that strip away electrons from atoms Indirect - uncharged that have to.
LRT2004 Sudbury, December 2004Igor G. Irastorza, CEA Saclay NOSTOS: a spherical TPC to detect low energy neutrinos Igor G. Irastorza CEA/Saclay NOSTOS.
Muon Detector Jiawen ZHANG Introduction The Detector Choices Simulation The structure and detector design The Expected performance Schedule.
GEM: A new concept for electron amplification in gas detectors Contents 1.Introduction 2.Two-step amplification: MWPC combined with GEM 3.Measurement of.
Design of a readout system for RPCs Olu Amoda2 The LODEN Group The group is an association of Fermilab scientists who teamed up to build a cosmic ray.
Muon Detection with Resistive Plate Chambers (vis a vis MARTA upgrade proposal) Joseph Berlin Penn State University Auger Data Analysis Meeting, Oct
Ionization Detectors Basic operation
High voltage V = 300 Pixel capacitance C = 3 fF Embedded resistance R = 50K  Recovery time = 1 ns Pixel density = 10 4 cm -2 4 X estimated SLHC rate =
Experimental and Numerical studies on Bulk Micromegas SINP group in RD51 Applied Nuclear Physics Division Saha Institute of Nuclear Physics Kolkata, West.
Using delay lines on a test station for the Muon Chambers Design considerations (A. F. Barbosa, Jul/2003)
CALICE 03/14/05Ed Norbeck U. of Iowa1 PPACs in a Calorimeter Edwin Norbeck University of Iowa.
Takeshi Fujiwara, Hiroyuki Takahashi, Kaoru Fujita, Naoko Iyomoto Department of Nuclear Engineering and Management, The University of Tokyo, JAPAN Study.
Ion signals with R134a and R134 in a parallel plate proportional counter Edwin Norbeck, J. E. Olson, Y. Onel University of Iowa For Sec. DH-3 of DNP06.
December 10, The Parallel Plate Chamber CERN Presentation Wout Kremers Detector R&D NIKHEF.
Ion signals with R134a and R134 in a parallel plate proportional counter Y. Onel, E. Norbeck, J. E. Olson University of Iowa For HCAL meeting at Fermilab.
An Estimation of Critical Electron Density at Just Starting Breakdown in Gases Mase. H Professor Emeritus of Ibaraki University.
PPAC in ZDC for Trigger and Luminosity Edwin Norbeck University of Iowa Luminosity Workshop November 5, 2004.
Study of gas mixture containing SF6 for the OPERA RPCs A.Paoloni, A. Mengucci (LNF)
Proposal of a digital-analog RPC front-end for synchronous density particle measure for DHCAL application R.Cardarelli and R.Santonico INFN and University.
1 Analysis of Small RPC DHCAL Prototype Data (noise and cosmic ray) LCWA09, Albuquerque, New Mexico Friday, October 02, 2009 Qingmin Zhang HEP Division,
16 Sept PSD 7 Liverpool 1 MHSP with position detection capability MHSP with position detection capability H. Natal da Luz a,b, J.F.C.A. Veloso a,b,
Gas detectors in a ZDC (at LHC) Edwin Norbeck and Yasar Onel University of Iowa For7 th CMS Heavy-Ion meeting at Delphi June 2003.
Development of a Single Ion Detector for Radiation Track Structure Studies F. Vasi, M. Casiraghi, R. Schulte, V. Bashkirov.
Small, fast, low-pressure gas detector E. Norbeck, J. E. Olson, and Y. Onel University of Iowa For DNP04 at Chicago October 2004.
PPAC Jonathan Olson University of Iowa Thesis Defense 8 April 2005.
PPAC Parallel Plate Avalanche Counter Edwin Norbeck University of Iowa For meeting at SLAC June 2, 2004.
PPAC Jonathan Olson University of Iowa HCAL November 11-13, 2004.
Electric Pressure Transducer
GEM TPC Resolution from Charge Dispersion*
Simulation of the Time Response of a VPT
The PSD at Pb-Pb run PSD drawbacks at Ar beam
Activities on straw tube simulation
GEM, applications for SR experiments and tracking in HEP
TDR Measurement of MCP Anode
Analog FE circuitry simulation
Multigap Resistive Plate Chambers (MRPC)
Radiation Detectors : Detection actually means measurement of the radiation with its energy content and other related properties. The detection system.
Ionization detectors ∆
Semiconductor Detectors
Capacitance and Capacitors
Presentation transcript:

E. Norbeck U. IowaFast Gas Detector APR 05 Tampa1 Small Fast Gas Detector for High-Energy Electrons E. Norbeck, J.E. Olson, and Y. Onel University of Iowa

E. Norbeck U. IowaFast Gas Detector APR 05 Tampa2 Example of low-pressure PPAC (Parallel Plate Avalanche Counter) Two flat plates Separated by 1 mm Filled with 100 torr hydrocarbon 1000 V between plates Simple, low cost device Unaffected by heat, light Can be radiation hard

E. Norbeck U. IowaFast Gas Detector APR 05 Tampa3 For high speed, the RC time constant must be kept small. Only PPACs of small area are fast, ~1 ns R = 50 Ω (coax cable). C is the capacity between the plates Speed vs Size

E. Norbeck U. IowaFast Gas Detector APR 05 Tampa4 Single Pixel PPAC Gap 0.6 mm 950 V across gap Cathode 7X 0 = 29 mm of tantalum Area of anode is 1.0 cm 2 Guard ring to simulate neighboring pixels Detail of gap and guard ring

E. Norbeck U. IowaFast Gas Detector APR 05 Tampa5 New Detector with less inductance Same signal width of 1.5 ns for isobutane at 80 torr.

E. Norbeck U. IowaFast Gas Detector APR 05 Tampa6 Test at home with a 7 mCi 137 Cs source Get up to 20 mV signals directly into 50  coax

E. Norbeck U. IowaFast Gas Detector APR 05 Tampa7 Signal into coax with no amplifier Signal observed directly with fast scope C (out)

E. Norbeck U. IowaFast Gas Detector APR 05 Tampa8 The signal is divided between the detector capacitance and the output capacitance. The sum of the two provides energy for damaging sparks. For small detectors we use a ratio of 20. For large detectors we make them equal.

E. Norbeck U. IowaFast Gas Detector APR 05 Tampa9 We did not have high-energy electrons so we made them in situ from protons interacting near the front end of our tantalum cylinder. The showers had amplitudes as much as 40 mV

E. Norbeck U. IowaFast Gas Detector APR 05 Tampa10 Signal Shape from Shower -30 mV 1.62 ns FWHM One third of amplitude of fast signal is lost in 20 m of standard RG-58 coax.

E. Norbeck U. IowaFast Gas Detector APR 05 Tampa11 The signal comes from moving charges. In an avalanche, most of the electrons and ions are formed near the anode. The electron signal is fast but with a total area small compared with the ion signal. The ion signal is flat while the ions are moving and stops when the ions are collected. In the next slide, when the ions are collected at the cathode they liberate electrons.

E. Norbeck U. IowaFast Gas Detector APR 05 Tampa12 20 torr ethane 550 V 0.6 mm gap

E. Norbeck U. IowaFast Gas Detector APR 05 Tampa13 Gases that have been used C 4 H 10 C 2 H 6 CH 4 Argon - CO 2 Alkanes work well as avalanche gases But only at 1 atm pressure CF 4 C 3 F 8 C 4 F 8 cyclo Additional benefit with perfluoro-analog

E. Norbeck U. IowaFast Gas Detector APR 05 Tampa14 Many advantages to operating at atmospheric pressure CF 4 gives nice signals at 2500 V 95% Ar + 5% CO 2 operates at 1100 V, but with a slow, 5 ns, fast signal. It also has a smaller useful operating range than CF 4 For 0.6 mm spacing

E. Norbeck U. IowaFast Gas Detector APR 05 Tampa15 Advantages of Perfluro gasses Not toxic Does not burn Resists aging Easily recycled (A small chemical cartridge can be inserted in the gas line that will remove all impurities from the gas) High density (more primary electrons) Contains no chlorine so is allowed in national laboratories We found good results with 0.6 mm spacing, but not so good with 2.5 mm. More study on this is needed.

E. Norbeck U. IowaFast Gas Detector APR 05 Tampa16 One plate can be divided into pixels to provide position resolution.

E. Norbeck U. IowaFast Gas Detector APR 05 Tampa17 PPAC Readout - + Summing amplifier can be used to add PPAC signals, increasing the effective size of PPAC (without increasing the time width of the signals)

E. Norbeck U. IowaFast Gas Detector APR 05 Tampa18 Cautions Simple scaling of plate spacing, pressure, voltage, etc. does not apply over a wide range of parameters. Look at wave form to make sure the signal is clean.

E. Norbeck U. IowaFast Gas Detector APR 05 Tampa19 CONCLUSIONS PPACs for a calorimeter Can be made radiation hard. Can provide position information. Have good energy resolution for high energy showers. Have sub nanosecond time resolution. Can connect PPACs directly into 50  coax Can test with  source on side