Ion Exchange Chromatography. Some ion exchangers are regarded as weak, that is functioning best over a comparatively narrow pH range, while others.

Slides:



Advertisements
Similar presentations
Chromatography Components stationary phase (eg., solid matrix) mobile phase (eg., solvent) solute Solutes which interact differently with the stationary.
Advertisements

Isofocusing Chromatography Prepared by- Shirin Akhter.
Umair Saleem Methods in protein chemistry Hydrophobic interaction chromatography.
Chromatography for Protein purification 1
HPLC Analysis of Ionic Compounds Nicholas H. Snow Seton Hall University.
Ion Exchange Laboratory. Today’s Schedule Pre-lab discussion Ion Exchange and Spectrophotometer Ion exchange experiment.
ION EXCHANGE CHROMATOGRAPHY PREPARED BY- MD.MARUF HASSAN.
Commonly used separation techniques SS ize exclusion II on exchange AA ffinity RR eversed phase, HH ydrophobic interaction.
Ion-Pair Chromatography In addition to the aqueous buffer and an organic solvent that is typical for reversed-phase, the mobile phase contains a counter.
Bio 98 - Lecture 4 Amino acids, proteins & purification.
Gel filtration Chromatography
Which of the following amino acids would be first to elute at pH 7 from an anion-exchange column? a). glutamic acid b). alanine c). lysine d). asparagine.
HPLC when GC won’t cut it!!!. Types of HPLC Reverse-phase (water/MeOH-soluble) Normal Phase (very polar) Adsorption (very non-polar) Ion-Exchange (ionic)
Amino Acid Analyzer Nashwa Othman.
Salting out is a method of separating proteins based on the principle that proteins are less soluble at high salt concentrations. The salt concentration.
Protein Purification. Why purify Proteins? Characterize Function Activity Structure Study protein regulation and protein interactions Use in assays Produce.
Created with MindGenius Business 2005® Ion Exchange Chromatography Ion Exchange Chromatography Principles Small K means low affinity – so low RT K is often.
Ion Exchange Chromatography. Cation exchangers They contain immobilized anionic groups that bind to cations. e.g. a matrix with carboxymethyl group(CM)
Cation Exchange Column CHEE450 Leslie Davis. Cation Exchange Following removal of biomass – processes supernatant Separate insulin precursor from glucose,
Separation of proteins by ion exchange chromatography
Chromatography Chapter 4 1 Dr Gihan Gawish. Definition Dr Gihan Gawish  Ion-exchange chromatography (or ion chromatography) is a process that allows.
B IOCHEMICAL INSTRUMENTAL ANALYSIS -11 Dr. Maha Al-Sedik.
Principles for HPLC Methods Development Bioanalytical Chemistry Lecture Topic 4.
Chromatography Desalting and Affinity. Chromatography Technique to separate components of a mixture by passing them through a matrix. –A solvent is used.
Buffers and the Henderson-Hasselbalch Equation -many biological processes generate or use H + - the pH of the medium would change dramatically if it were.
Chapter Five Protein Purification and Characterization Techniques
Types of Mechanism in the Chromatography
Analysis of Proteins and Peptides Amino acid composition Molecular weight Isoelectric point Subunit structure Prosthetic groups Solubility Biological activity.
BIOCHEMICAL METHODS USED IN PROTEN PURIFICATION AND CHARACTERIZATION
Lab 6 Salt fractionation In aqueous environments salt ions interact strongly with their complementary charge on a water molecule If the concentration of.
Ion exchange chromatography
Dissociation and Neutralization GLE What is dissociation? The process by which an ionic compound separates into its positive ions (cations) and.
CHEMISTRY 1000 Topic #2: The Chemical Alphabet Spring 2013 Dr. Susan Findlay Gallium, Ga Sodium, Na Forms of Carbon.
Amino acids/Proteins.
High Performance Liquid Chromatography. The chromatogram is a record of detector output Vs time as the analyte passes through the chromatography.
Separation techniques ?. Molecules can be separated: Chemically: by charge, by action with specific reagents Physically: by solubility, by molecular weight,
Exam next week: Chapter 4?
Biochemical instrumental analysis - 11 Dr. Maha Al-Sedik 2015 CLS 332.
AMINO ACIDS PTT 202: ORGANIC CHEMISTRY FOR BIOTECHNOLOGY PREPARED BY:
Quiz Next Tuesday (09/18). Figure 4.18 Cation (a) and anion (b) exchange resins commonly used for biochemical separations.
Introduction to Instrumental Analysis - Chromatography
Protein Purification for Crystallization Dr Muhammad Imran Forman Christian College (A Chartered University) Dr Muhammad Imran Forman Christian College.
KAU-Faculty of Science- Biochemistry department Analytical biochemistry lab (Bioc 343) 2012 T.A Nouf Alshareef
Desai Chandni  In ion exchange chromatography, retention is based on the attraction between the solute ions and charged sites bound to stationary phase.
Ion exchange chromatography
Food Analysis Lecture 18 (03/27/2012) Basic Principles of Chromatography (3) Qingrong Huang Department of Food Science Read Material: Chapter 27, page.
Tutorial 09 Overview of other chromatographic methods 1.
Purification of immunoglubin by ion exchange chromatography Bahiya Osrah
CROMATOGRAFIA. Anion-exchange Protein at pH higher than pI (by at least 1 unit) is negatively charged and binds to anion-exchange column. Elution.
Lab 6 Ig Purification What will the Ig be used for? How pure does it need to be? What is the source of the antibody (serum, ascites, cell culture supernatant)
Chromatography PlanarColumn Paper TLC (Thin layer chromatography)
Principles of chromatography
Tutorial 11 Modes and Methods in Capillary Electrophoresis
Protein Characterization/Purification
Amino Acids, Peptides, and Proteins
Ion Exchange Chromatography
Ion Exchange Chromatography
Protein Purification Fig. 5-CO, p.113
Column Chromatography
Gel Filtration Chromatography.
HERBAL DRUG FORMULATION Presented by : Department of Natural Product Research Acube Lifesciences.
Biophysical Tools '04 - Chromatography
Dnyanasadhana College, Thane. Department of Chemistry M. Sc
Separation of Molecules by Ion Exchange Chromatography
Ion exchange chromatography By Mennatallah Abdelshaheed.
Protein Purification Fig. 5-CO, p.113
Last class Salting out Dialysis Paper 1 discussion.
Separation of Molecules by Ion Exchange Chromatography
Experiment 3 Separation of proteins by Anion exchange chromatography
Presentation transcript:

Ion Exchange Chromatography

Some ion exchangers are regarded as weak, that is functioning best over a comparatively narrow pH range, while others are strong, that is functioning over a wider pH range. Exchangers with quaternary amino or sulfonic acid groups behave as strong anion and cation exchangers, respectively, while aromatic/aliphatic amino and carboxylic acid groups are weak anion and cation exchangers, respectively. Choice of ion exchange stationary phase is heavily influenced by knowledge of the pI of the protein of interest.

In an ion exchange chromatography experiment (Figure), sample is applied to a stationary phase which has been charged with the ion to be exchanged; the counterion (e.g. Cl−). The protein (and any other species of like charge in the sample) may exchange with this counterion, binding to the ion exchanger. It is important that the sample is free of components of like charge since these are usually present in large molar excess relative to the concentration of protein. The ion exchanger will not distinguish between proteins possessing a single positive charge and, for example, a Na+ ion also present in the sample.

Desalting is carried out before ion exchange either by gel filtration chromatography, by dialysis or by centrifugal filtration. Elution of bound proteins is achieved by reversing the process of binding and, again, exchanging a counterion for protein. This is usually carried out by applying a large excess of a salt (e.g. NaCl) containing the counterion in the mobile phase. Because proteins have different net charge, they may bind to an ion exchanger at a given pH with a variety of strengths, that is some proteins may bind strongly whilst others bind weakly or not at all. We can take advantage of this to separate proteins by applying salt in a continuous gradient. Weakly bound proteins will elute first from such a system while strongly bound proteins elute later.

Selection of an Ion Exchanger

Below the isoelectric pH the protein has a positive charge and binds to a cation exchanger. Above the isoelectric pH the protein has a negative charge and binds to an anion exchanger.

Choice of Buffer Cationic buffer should be used with anion exchanger. Anionic buffer should be used with cation exchanger.

Ion exchangers are commonly used in column form.