2730/2730T/5730 Performance Comparison 20 May 2008.

Slides:



Advertisements
Similar presentations
Module – 3 Data protection – raid
Advertisements

Miss Penalty Reduction Techniques (Sec. 5.4) Multilevel Caches: A second level cache (L2) is added between the original Level-1 cache and main memory.
© 2009 IBM Corporation Statements of IBM future plans and directions are provided for information purposes only. Plans and direction are subject to change.
Engenio 7900 HPC Storage System. 2 LSI Confidential LSI In HPC LSI (Engenio Storage Group) has a rich, successful history of deploying storage solutions.
The TickerTAIP Parallel RAID Architecture P. Cao, S. B. Lim S. Venkatraman, J. Wilkes HP Labs.
© 2009 IBM Corporation Statements of IBM future plans and directions are provided for information purposes only. Plans and direction are subject to change.
© 2009 EMC Corporation. All rights reserved. EMC Proven Professional The #1 Certification Program in the information storage and management industry Data.
Chapter 3 Presented by: Anupam Mittal.  Data protection: Concept of RAID and its Components Data Protection: RAID - 2.
An Adaptable Benchmark for MPFS Performance Testing A Master Thesis Presentation Yubing Wang Advisor: Prof. Mark Claypool.
Computer ArchitectureFall 2007 © November 28, 2007 Karem A. Sakallah Lecture 24 Disk IO and RAID CS : Computer Architecture.
1 Lecture 26: Storage Systems Topics: Storage Systems (Chapter 6), other innovations Final exam stats:  Highest: 95  Mean: 70, Median: 73  Toughest.
Computer ArchitectureFall 2008 © November 12, 2007 Nael Abu-Ghazaleh Lecture 24 Disk IO.
Intelligent Storage Systems
MODULE 5: Introduction to Memory system
Storage Networking Technologies and Virtualization Section 2 DAS and Introduction to SCSI1.
© 2009 IBM Corporation Statements of IBM future plans and directions are provided for information purposes only. Plans and direction are subject to change.
© 2009 EMC Corporation. All rights reserved. Intelligent Storage Systems Module 1.4.
Introduction to Database Systems 1 The Storage Hierarchy and Magnetic Disks Storage Technology: Topic 1.
Comparing Coordinated Garbage Collection Algorithms for Arrays of Solid-state Drives Junghee Lee, Youngjae Kim, Sarp Oral, Galen M. Shipman, David A. Dillow,
RAID-x: A New Distributed Disk Array for I/O-Centric Cluster Computing Kai Hwang, Hai Jin, and Roy Ho.
© 2009 EMC Corporation. All rights reserved. EMC Proven Professional The #1 Certification Program in the information storage and management industry Intelligent.
Robert Larson Delivery Architect Microsoft Corporation SESSION CODE: WSV316 David Lef Principal Systems Architect Microsoft Corporation.
Nexenta Proprietary Global Leader in Software Defined Storage Nexenta Technical Sales Professional (NTSP) COURSE CONTENT.
ISDMR:BEIT VIII: CHAP2:MADHU N 1 ISM - Course Organization.
Key Perf considerations & bottlenecks Windows Azure VM characteristics Monitoring TroubleshootingBest practices.
Copyright DataDirect Networks - All Rights Reserved - Not reproducible without express written permission Adventures Installing Infiniband Storage Randy.
Nexenta Proprietary Global Leader in Software Defined Storage Nexenta Technical Sales Professional (NTSP) COURSE CONTENT.
Copyright © 2014 EMC Corporation. All Rights Reserved. Block Storage Provisioning and Management Upon completion of this module, you should be able to:
Chapter 5 Section 2 : Storage Networking Technologies and Virtualization.
Storage Benchmark Proposal Edgar StPierre, EMC. Proposal Project Name: STORPERF Repo Name: STORPERF Category: Requirements Project Lead: Edgar StPierre,
Module – 4 Intelligent storage system
Storage Management in Virtualized Cloud Environments Sankaran Sivathanu, Ling Liu, Mei Yiduo and Xing Pu Student Workshop on Frontiers of Cloud Computing,
IBM System Storage™ DS3000 Series
© Pearson Education Limited, Chapter 16 Physical Database Design – Step 7 (Monitor and Tune the Operational System) Transparencies.
DAC-FF The Ultimate Fibre-to-Fibre Channel External RAID Controller Solution for High Performance Servers, Clusters, and Storage Area Networks (SAN)
Hadoop Hardware Infrastructure considerations ©2013 OpalSoft Big Data.
Storage Systems Market Analysis Dec 04. Storage Market & Technologies.
© 2009 EMC Corporation. All rights reserved. Intelligent Storage Systems Module 1.4.
DBI313. MetricOLTPDWLog Read/Write mixMostly reads, smaller # of rows at a time Scan intensive, large portions of data at a time, bulk loading Mostly.
Switched Storage Architecture Benefits Computer Measurements Group November 14 th, 2002 Yves Coderre.
I/O Computer Organization II 1 Introduction I/O devices can be characterized by – Behavior: input, output, storage – Partner: human or machine – Data rate:
Programming for GCSE Topic 5.1: Memory and Storage T eaching L ondon C omputing William Marsh School of Electronic Engineering and Computer Science Queen.
5/8/09 Titanium Performance Update 2 Dot Hill Confidential.
© 2011 IBM Corporation Sizing Guidelines Jana Jamsek ATS Europe.
ONStor Pantera 3110 ONStor NAS. Copyright 2008 · ONStor Confidential Pantera 3110 – An Integrated Channel only NAS  Integrated standalone NAS system.
Infrastructure for Data Warehouses. Basics Of Data Access Data Store Machine Memory Buffer Memory Cache Data Store Buffer Bus Structure.
STORAGE ARCHITECTURE/ MASTER): Disk Storage: What Are Your Options? Randy Kerns Senior Partner The Evaluator Group.
General Sizing Discussion Jana Jamsek ATS Europe
SATA In Enterprise Storage Ron Engelbrecht Vice President and General Manager Engineering and Manufacturing Operations September 21, 2004.
Filename\location The Marketing Numbers VA7410VA7400VA K cache IOPs 28K cache IOPs 12K cache IOPs 11,000 IOPs8,500 IOPs3,400 IOPs 330MB/s180MB/s93MB/s.
Spring EE 437 Lillevik 437s06-l22 University of Portland School of Engineering Advanced Computer Architecture Lecture 22 Distributed computer Interconnection.
Page 1 Mass Storage 성능 분석 강사 : 이 경근 대리 HPCS/SDO/MC.
Copyright © 2010 Hitachi Data Systems. All rights reserved. Confidential – NDA Strictly Required Hitachi Storage Solutions Hitachi HDD Directions HDD Actual.
Paper by: Chris Ruemmler and John Wikes Presentation by: Timothy Goldberg, Daniel Sink, Erin Collins, and Tony Luaders.
RAID Technology By: Adarsha A,S 1BY08A03. Overview What is RAID Technology? What is RAID Technology? History of RAID History of RAID Techniques/Methods.
Network-Attached Storage. Network-attached storage devices Attached to a local area network, generally an Ethernet-based network environment.
HUAWEI TECHNOLOGIES CO., LTD. Huawei Storage ISM Management Pre-sales Product Training Materials Easy and Efficient WEU IT Solution Team.
© 2009 EMC Corporation. All rights reserved. Why do we need RAID o Performance limitation of disk drive o An individual drive has a certain life expectancy.
© 2006 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice DP SAS Drives.
System Storage TM © 2007 IBM Corporation IBM System Storage™ DS3000 Series Jüri Joonsaar Tartu.
E2800 Marco Deveronico All Flash or Hybrid system
Ryan Leonard Storage and Solutions Architect
TYPES OF MEMORY.
Fujitsu Training Documentation RAID Groups and Volumes
Software Architecture in Practice
Direct Attached Storage and Introduction to SCSI
Storage Team (Controller Performance) Aggregate Utilization
VNX Storage Report Project: Sample VNX Report Project ID:
Unity Storage Array Profile
Cost Effective Network Storage Solutions
Presentation transcript:

2730/2730T/5730 Performance Comparison 20 May 2008

Dot Hill Systems Confidential / Covered under NDA NDA Notification This presentation contains information related to projects that are currently in planning and/or development stages. This information represents the current intentions of Dot Hill Systems. However, all aspects of these projects, including, but not limited to funding, availability, shipping dates, configurations, capacities, performance, and all other characteristics are subject to change and/or cancellation without notice. This material is confidential to Dot Hill Systems and should be disclosed to external entities only under the terms of an executed non-disclosure agreement (NDA). Distribution of this material to Dot Hill Systems Field Representatives should be done through the Dot Hill Systems NDA process. The information contained herein is considered privileged, confidential and protected from disclosure. If you are not the intended recipient or their employee/agent responsible for its delivery, you are requested to refrain from any duplication or distribution of this message or its contents, in respect of the rights of the designated recipient and sender, and to delete it from your computer. 2

Dot Hill Systems Confidential / Covered under NDA About This Presentation Project Name “Neptune” refers to the 2730/2730T Project Name “Krypton” refers to the 5730 The performance information contained in this presentation was obtained within the Engineering Verification Lab using IOMeter Actual performance results within specific application use may vary from the contents of this presentation This information is provided only as a reference point and no “performance tuning” has been applied 3

Dot Hill Systems Confidential / Covered under NDA 2730 vs Quick Reference 4 Sequential Access2730/2730T5730Comments Read Disk Bandwidth (RAID5) Fail-Over: 550 MB/s Active/Active: 1100 MB/s Fail-Over: 790 MB/s Active/Active: 1580 MB/s % faster read throughput PCIX/DDR dependent CPU independent Write Disk Bandwidth (RAID5) Fail-Over: 340/380 MB/s Active/Active: 640/730 MB/s Fail-Over: 575 MB/s Active/Active: 980 MB/s % faster write throughput PCIX/DDR dependent primarily CPU dependent on lower end Read Disk IOpsActive/Active: 29K/48K IOPs Active/Active: 112K/160K IOPs % faster read transactions PCIX/DDR independent CPU dependent Read Cache Hit Same Sector Active/Active: 100K/150K IOPs Active/Active: 320K/375K IOPs Same sector transaction rate shows the power of 5730 FC target and CPU low latency performance Write Disk IOps (RAID5) Active/Active: 11K/19K IOPs Active/Active: 33K/41K IOPs % faster write transactions PCIX/DDR independent CPU dependent

Dot Hill Systems Confidential / Covered under NDA 5730 (5730) Performance Quick Reference 5 Sequential Bandwidth Performance Controller Configuration Host Access VDisk Type MeasurementReference / Comments Dual (Active/Active) ReadAll1580MB/sFour hosts systems connected, each accessing one LUN, two LUNs owned per controller. Note: RAID10 requires additional total drives to meet maximum number. Dual (Active/Active) WriteRAID0 RAID5 RAID6 RAID10 RAID MB/s 987 MB/s 914 MB/s 882 MB/s 1003 MB/s Sequential Transaction Performance Controller Configuration Host Access VDisk TypeMeasurementComments / Reference Dual (Active/Active)ReadRAID5143.1K IO/s 160K IO/s Four hosts systems connected, each accessing one LUN, two LUNs owned per controller. Single (Fail-Over) Dual (Active/Active) WriteRAID539.4K IO/s 25.5K IO/s Dual (Active/Active)Same Sector N/A375K IO/s512B read same sector (cache hit) access using four hosts systems connected, each accessing one LUN, two LUNs owned per controller. Random Transaction Performance Controller Configuration Host Access VDisk Type Measurement Dual (Active/Active)ReadAll24.9K IO/s Single (Fail-Over) Dual (Active/Active) WriteRAID5 RAID6 RAID0 RAID10 5.4K IO/s 4.1K IO/s 3.1K IO/s 13.0K IO/s 8.3K IO/s

Dot Hill Systems Confidential / Covered under NDA 5730’s storage controller processor accounts for the higher sequential write transaction performance both Active/Active and failed over sustains between 150% and 220% higher write transaction performance than 2730T at deeper queued small block host request sizes. 2730T vs in RAID 5 & 6 RAID 5 & 6 Sequential Write with 48 drives

Dot Hill Systems Confidential / Covered under NDA 2730T vs in RAID 5 & 6 RAID 5 & 6 Sequential READ with 48 drives 5730 controller read bandwidth is 800MB/s per controller versus 2730T peaking at 570MB/s sustains 40% higher read throughput then 2730T at large block sizes. The Active/Active 5730 read performance in the curve is limited by the four port FC host Active/Active read performance can sustain 1600MB/s with multiple host systems accessing.

Dot Hill Systems Confidential / Covered under NDA 5730 Scalability Testing (24 – 60 Drives) Active/Active Controller Random Read/Write Drive numbers have a much larger affect on random performance. For reads there is almost a direct correlation between the total number of drives accessed and the total random transaction IOPS. The drive random access performance is the limiting factor for reads in general. Writes top out at 48 drives. Additional drives won’t improve random write numbers. The limit becomes the controller processing and cache algorithm.

Dot Hill Systems Confidential / Covered under NDA 5730 Max Configuration (108 Drive) Sequential Reads/Writes for Active/Active (Throughput & IOPS) The RAID50 VDisk in this configuration is 27-drives, with 3 sub-arrays of 9-drive RAID5. In this test configuration two dual port host systems are connected through the switch to Each host accesses the 4 LUNs presented by the 5730 Active/Active RAID system. Each host issues a queue depth / LUN, therefore each LUN sees 2x the total queue depth of each host.