CALPORT 300 Three-Phase Portable Reference Standard
Outstanding customer value One unit Analysis of the load for all tests and mains quality On side Test of CT- and Meter test PT-transformers Control of installation Periodical tests pre- prevents connection vent financial losses circuit errors
Particularities I2h and U2h measurements Harmonics measurement Vector diagram Burden measurements Control of CT- and PT-transformers I2h and U2h measurements Print functions Meter error measurements Memory functions Harmonics measurement
CALPORT 300 Three-phase Portable Reference Standard 0.5 ... 480 V (phase-neutral) 1 mA … 120 A direct connections Clip-on CTs: 100A / 1.000A / LEMflex© up to 3.000A / Hot sticks for measure-ment on high voltage potential Vector diagram, harmonics spectrum, wave form and rotary field display Burden measurement and ratio tests of CT’s and PT’s Accuracy 0.05 %
Connections [1] Current-Inputs I1, I2, I3 [2] Current-Outputs I1, I2, I3 [3] Phase connection for voltage [4] Neutral connection for voltage [5] 100 A CTs connector [6] 1000 A CTs connector [7] LEMflex (up to 3000 A) connector [8] Hot sticks connector [9] Serial interface RS 232 C
Connections [10] Compact flash card slot [11] Impulse inputs 1, 2, 3 [12] Impulse outputs 1, 2, 3 [13] Auxiliary supply connector [14] Graphical colour display [15] Rotary switch [16] Cursor keys [17] Alphanumeric key pad
Options of current clamps to the CALPORT 300 Error compensated clip-on CT’s for measurements in the range 50 mA … 100 A Clip-on CTs for measurements in the range 2 A … 1000 A Flexible current transformers LEMflex for measurements up to 30 / 300 / 3000 A Hot sticks for measurements on high voltage potential
Operation Concept Symbols Display Rotary switch / Control Keys
Software Main Menu First Row Meter Testing Measurement Harmonics, Oscilloscope Energy Measurement Transformer Test Further Tests Installation (Setup)
Software Measurement – Basic Quantities Second Row Measurement UI Data storage
Software Measurement – Basic Quantities Second Row Measurement PQS Data storage
Software Measurement – Basic Quantities Second Row Measurement UIPQS Data storage
Software Measurement – Vector Diagram Second Row Vector analysis Data storage
Software Measurement – Oscilloscop First Row Selection of U Selection of I Data storage Exit to previous menu
Software Measurement – Harmonics First Row Selection of U Selection of phase Scale Data storage Exit to previous menu
Software Measurement – Energy Second Row Start energy measurement Reset and restart energy measurement Voltage and current range settings menu Data storage
Software Measurement – Register test Second Row Start or stop register test Enter counters before meas. Enter counters after meas. Reset register test Setup register test Range settings Data storage
Software Measurement – Voltage Burden First Row Selection of phase Settings for voltage burden measurement Data storage Exit to previous menu
Software Measurement – Current Burden First Row Selection of phase Settings for current burden measurement Data storage Exit to previous menu
Software Measurement – Voltage Transformer Ratio First Row Reference for voltage ratio calculation Definition of reference NP or NS Data storage Exit to previous menu
Software Measurement – Current Transformer Ratio First Row Reference for current ratio calculation Definition of reference Data storage Exit to previous menu
Software Error measurement Second Row Start/Stop error measurement Restart of error measurement Setup of error measurement Data storage
Software Special function – fRef Test First Row Input of reference frequency Input of duration of test Start fRef test Data storage Exit to previous menu
Software Storage and printout of test results First Row Data storage Print data Preview of results Printer and save parameter settings Exit to previous menu
Software Storage and printout of test results Second Row Administrative data set Customer data set General info data set Meter data sets Other checks dataset Comment
Software Storage and printout of test results
Connection example Testing of an installed direct connected 4-wire meter
Connection example Testing of an direct connected 4-wire meter
Connection example Burden measurement of voltage transformer
Connection example Burden measurement of current transformer
Connection example Measurement of transformer ratio
Connection example Hotsticks Measurement
Windows©-Software CALSOFT Selection of real time readout or readout of sets of data from CALPORT 300 memory
Windows©-Software CALSOFT Display of read data on PC monitor