Integrity Testing of Aboveground Storage Tanks 2012 Southern Section AWMA Annual Meeting and Conference Andrew Covington, P.E.

Slides:



Advertisements
Similar presentations
Underground Storage Tanks at Duke Duke Medical Center –8 permitted USTs located on medical campus –Range in size from 2,000 gallons to 30,000 gallons Proper.
Advertisements

Initiating Devices Manual Fire Alarm Boxes Ionization Smoke Detectors
Spill Containment, Controls and Countermeasures 1.
Smithfield Foods, Inc. Environmental Training Conference June 4, 2012 John Meyer, P.E. Director of Environmental Affairs & Sustainability John Morrell.
Spill Prevention Control & Countermeasures Compliance and Planning.
Occupational Safety and Health Course for Healthcare Professionals.
Visit Us At Booth #306 J2 Engineering, Inc. J2 provides Construction and Environmental Services and is a verified Service-Disabled Veteran-Owned Small.
ANNUAL SPILL PREVENTION CONTROL AND COUNTERMEASURE TRAINING (SPCC) Presented by: Prepared for: Stephen F. Austin State University February 2, 2012.
NPMA Alan Watson Alexandria May 2012 Tank foundations Presenting
Petroleum Equipment Institute
Responsible CarE® Process Safety Code David Sandidge Director, Responsible Care American Chemistry Council June 2010.
Southwest District Storage Tanks Program presented by Leslie Pedigo Southwest District Storage Tanks Program presented by Leslie Pedigo.
U.S. Department of Transportation Pipeline and Hazardous Materials Safety Administration NW Area Committee Meeting Focus on Pipelines PREVENTION & PREPAREDNESS.
Crane Operations Objective
1 MASSACHUSETTS UNDERGROUND STORAGE TANK (UST) PROGRAM Baseline Compliance Assessment 1 MassDEP 8/2/2011.
Ohio’s One-Stop Utility Resource Gas Pipeline Safety Pipelines - State and Local Issues Pete Chace GPS Program Manager (614)
The New SPCC Rule U. S. EPA Region 7
Jack Harrah Governor’s Office of Emergency Services
DEVELOPING A FACILITY INSPECTION PROGRAM Or How To Make Sure The Facility You Inspect is Operating Successfully Morson Environmental Consulting, Inc.
Bulk Fertilizer Regulations For Farm Facilities Ohio Department of Agriculture Pesticide & Fertilizer Section 8995 East Main Street Reynoldsburg, Ohio.
SPILL PREVENTION CONTROL AND COUNTERMEASURE (SPCC) Title 40 CFR 112.
Virtual Environmental, Health & Safety Manager Compliance Management System T. Cozzie Consulting, Inc. telephone
Tank Consultants, Inc West 21st Street Tulsa, Oklahoma Telephone Fax
Fire Protection John Giefer. Statistics In the Drilling Industry In the Drilling Industry 25% of all inspections found violations of (21 inspections.
OSHA Long Term Care Worker Protection Program.  Recognize the purpose of the hazard communication standard.  Describe the components of a hazard communication.
U.S. Environmental Protection Agency
Annual Briefing: Spill Prevention Control and Countermeasure Plan (SPCC) Managed Services Administration Freeport, Texas ____________________ _365.
SPCC Plans Also known as…Spill Prevention, Control, & Countermeasures Plan Required as part of 40 CFR Part 112 – Oil Pollution Prevention. The Plan: Applies.
Aboveground Petroleum Storage Act Workshop (APSA).
CNG STATION & GARAGE MODIFICATION CODES & STANDARDS Graham Barker Business Development Manager.
OPERATOR, Tester & INSTALLER Licensing WWQRR, Chapter 17, Part L
Annual Briefing: Spill Prevention Control and Countermeasure Plan (SPCC) Instrument & Electrical Technical Services Freeport, Texas ____________________.
BRC Food Safety Quality Management System Training Guide
SPCC Regulations: Applicability and Requirements
Dailies, Weeklies, Monthlies, PSM Maintenance - Simplify IT If you’d like to reach SCS Engineers, Tracer Environmental Division please contact us at:
Shop-Fabricated Tank Inspection Chris Bashor Minnesota Pollution Control Agency June, 2001.
Presented to: RETA National Conference – Atlanta November 5, 2014 If you’d like to reach SCS Engineers, Tracer Environmental Division please contact us.
U.S. Department of Transportation Pipeline and Hazardous Materials Safety Administration Harold Winnie, CATS Manager (Central Region) Leak detection for.
Michigan’s Hydrogen Rules Department of Environmental Quality.
NFPA 31 Standard for the installation of Oil- Burning Equipment
Annual Briefing: Spill Prevention Control and Countermeasure Plan (SPCC) Central Maintenance Services Freeport, Texas ____________________ GHRIS CODE:
Air Conditioning International Mechanical Code
Presented to Georgia Airports Association Conference October 21, 2009 EPA Spill Prevention Control and Countermeasures – Update Also – What’s Coming with.
1 SPCC REGULATIONS Updating EPA’s Spill, Prevention, Control, and Countermeasure Regulations August 6, 2008 Air & Waste Management Association Andrew Covington,
March Why is MassDEP proposing new UST regulations? DFS’s regulation: standards for tanks construction, installation, O&M, decommissioning and.
MassDEP Underground Storage Tank Program Program Requirements for Owners and Operators Winter 2015 Workshops 1.
Prepared for Middle Georgia State University – Macon Campus Prepared by Geotechnical and Environmental Consultants, Inc.
WHAT IS RAFS? Organized in 2004 to Assist Rural Alaskan Communities Manage Their Bulk Fuel Facilities. Not-for-Profit Corporation. Initial funding provided.
BY: Winston G. Smith Environmental Engineer UST/PCB & OPA Enforcement & Compliance Section EPA Region 4.
Overview of 3 rd Party Inspection Program for USTs.
Tank Industry Consultants AWWA Tank Standard D101 The Development of the “Inspection of Water Tanks and Related Facilities” Standard Chip Stein, P.E. Managing.
| Excellence. Value. Get There!™ Aboveground Storage Tanks David L. Yaussy, Spilman Thomas & Battle, PLLC.
What you need to know. What is SPCC? Spill Prevention, Control, and Countermeasures Regulation Located in 40 CFR 112 Goes into effect May 10, 2013 GOAL:
JLAB Pressure Systems Considerations Ed Daly. Outline Introduction Federal Law - 10CFR851 Compliance JLAB Pressure Systems Program –Complies with 10CFR851,
WORKSHOP ON ACCREDITATION OF BODIES CERTIFYING MEDICAL DEVICES INT MARKET TOPIC 9 CH 8 ISO MEASUREMENT, ANALYSIS AND IMPROVEMENT INTERNAL AUDITS.
1 Iowa AWMA Meeting Kurt Shobe, MS, PG, CHMM GeoStat Environmental, LLC.
Firefighter Emergency Escape Systems New York State Department of Labor Public Employee Safety and Health (PESH)
Flammable Liquids Directorate of Training and Education
Process Safety Management Soft Skills Programme Nexus Alliance Ltd.
These materials have been developed based on applicable federal laws and regulations in place at the time the materials were created. The program is being.
Things Aren’t Always What They Seem A Stormwater Pollution Prevention / Good Housekeeping Case Study in Western New York.
Advanced Environmental Management (AEM) Training Phase I
Cross Connection Survey Training
Changes to Chapter , Florida Administrative Code Underground Storage Tank Systems (USTs) Effective – 1/11/2017.
Spill Prevention Control and Countermeasures
Spill Prevention, Control and Countermeasures (SPCC)
Control of Hazardous Energy
A Spill Plan that Works Michelle Barnett, P.E..
Cupa violation Review BAESG Meeting May 20, 2019 Matthew Burge
Presentation transcript:

Integrity Testing of Aboveground Storage Tanks 2012 Southern Section AWMA Annual Meeting and Conference Andrew Covington, P.E.

Presentation Outline Introduction About Eco-Systems, Inc. What Is Integrity Testing? Why Should I Have My Storage Tanks Inspected? SPCC Regulations Baseline Conditions Regulations/Industry Standards STI SP001 Hybrid Inspection Program Environmental Equivalence Other Considerations Regulatory Deadline Eco-Systems, Inc. Services Questions

Introduction Andrew Covington, P.E. ◦Professional Engineer ◦MS, AL, GA, LA, TX ◦Environmental/Petroleum Engineer ◦STI Certified Inspector ◦30 Years of relevant Experience ◦Expertise  Permitting & Compliance  Air Quality  SPCCs & SWPPPs

About Eco-Systems, Inc. Full Service Environmental Consulting Firm Service Areas: ◦Permitting & Compliance, ◦Natural Resources, ◦Remediation, ◦Planning, and ◦Engineering & Construction

What Is An SPCC? Federal regulation that requires a spill prevention control and countermeasure (SPCC) plan be in place. Designed to detect and prevent oil leaks, spills, or other potential integrity or structural issues before they can result in a discharge of oil to navigable waters of the U.S.

What Is Integrity Testing? A test performed to determine the useful life of a Storage Tank. Visual Inspection is an accepted integrity testing technique. Non-destructive type shell testing (Hydrostatic Testing, Radiographic Testing, Ultrasonic Testing, Acoustic Emissions Testing, etc.).

Why Should I Have My Storage Tanks Inspected? Workplace Safety Considerations Protection of the Environment Industry Standards Good Engineering Practices Regulatory Requirements

Purpose of SPCC and tank integrity testing?

SPCC Regulations 40 CFR Part (C) 6 Test or inspect each aboveground container for integrity on a regular schedule and whenever you make material repairs. You must determine, in accordance with industry standards, what are the appropriate qualifications for personnel performing tests and inspections, the frequency, and type of testing and inspections. Take into account container size, configuration, and design.

SPCC Regulations 40 CFR Part (C) 6 SPCC Regulations 40 CFR Part (C) 6 You must inspect the container's supports and foundations. You must inspect the outside of the container frequently for signs of deterioration, discharges, or accumulation of oil inside diked areas. You must keep complete records.

SPCC Regulations Testing on a ‘regular schedule’ means testing per industry standards or at a frequency sufficient to prevent discharges. Whatever schedule the P.E. selects must be documented in the Plan.

SPCC Regulations P.E. may choose to develop an inspection and testing program for the facility’s shop-built tanks in accordance with ◦ STI SP001, ◦ API 653, or ◦ Hybrid Program

Industry Standards Steel Tank Institutes (STI) SP001 American Petroleum Institute (API) 653 National Fire Protection Association Fire Code (NFPA 30) Local Fire Code(s) API 575 Atmospheric and Low Pressure Tanks API 570 Piping Inspection Code

STI SP001 Standard For The Inspection Of Aboveground Storage Tanks (Sept 2011, 5 th Edition) Section 1.2 states that SPOO1 standards are minimum requirements. Applies to: ◦ Aboveground Storage Tanks. ◦ Storing Stable, Flammable, & Combustible Liquids at Atmospheric Pressure and having a Specific Gravity less than 1.0. ◦ Operating Ambient Temperatures up to 200 Deg F.

STI SP001 At a minimum, the following tank components shall be inspected (as applicable): ◦ Primary tank ◦ Secondary tank ◦ Tank supports ◦ Tank anchors ◦ Tank foundation and external supports ◦ Tank gauges and alarms ◦ Insulation covering ◦ Tank appurtenances ◦ Normal vents ◦ Emergency vents ◦ Release prevention barriers ◦ Spill control systems

STI SP001 Tank Categories: ◦ Category 1  Secondary Containment  Continuous Release Detection Method (CRDM)  (Example - Elevated Tank where all sides of the tanks can be inspected except at the supports) ◦ Category 2  Secondary Containment  No CRDM – (Example - Tank shell in contact with soil) ◦ Category 3  No Secondary Containment  No CRDM

STI SP001

Inspection Of Field-Erected ASTS (Appendix B)

STI SP001 Periodic AST Inspections Conducted by Owner’s Inspector The personnel performing these inspections shall be knowledgeable of storage facility operations, the type of AST and its associated components, and characteristics of the liquid stored. (4.1).

STI SP001 Formal External and Internal Inspections Conducted by Certified Tank Inspector (4.2) A Certified Tank Inspector shall be certified by one or more of the following: ◦ API Standard 653 Authorized Inspector Certification with STI SP001 Adjunct Certification. ◦ STI Certified SP001 AST Tank System Inspector. ◦ Additional certifications as may be required by individual states or other governing bodies.

STI SP001 Suitability for Continued Service (10.0) Next formal internal inspection or the next formal external inspection, as applicable, may exceed the interval listed in STI SP001 (Table 5.5), if the corrosion rates allow and as determined by P.E.

STI SP001 Other Tank Damage (10.3) - An AST requires evaluation by an experienced engineer or tank manufacturer to determine if further action is needed if tank subjected to damage caused by the following conditions : ◦ Fire ◦ Natural disaster ◦ Excessive Settlement ◦ Overpressure ◦ Damage from Cracking

STI SP001 Recordkeeping (11) ◦ Retain each AST Record for the life of the AST. ◦ Retain each Monthly Inspection Checklist for at least 36 months. ◦ Retain each Annual Inspection Checklist for at least 36 months. ◦ Retain each Portable Container Monthly Inspection Checklist for at least 36 months. ◦ Retain all Certified Inspection Reports for the life of the AST.

Baseline Conditions ASTs With Known Baseline Conditions ◦ Shell thickness and ◦ Corrosion rates Only when the baseline is known, an inspection and testing program can be established on a regular schedule as per Industry Standards.

Baseline Conditions ASTs With Unknown Baseline Conditions ◦ For ASTs baseline conditions are not known, ◦ A regular integrity testing program cannot be established. ◦ P.E. must describe an interim schedule in the SPCC Plan.

Hybrid Inspection Program The P.E. may use industry standards, along with other good engineering principles, to develop a customized inspection and testing program for the facility.

Environmental Equivalence ◦ 40 CFR 112.7(a)(2) – Allows deviations from some requirements when the owner provides equivalent environmental protection by some other means of spill prevention, control, or countermeasure.

Environmental Equivalence Petroleum Marketers Association of America (PMAA) SETTLEMENT LANGUAGE: Well-designed shop-built containers with a shell capacity of 30,000-gallons or less Visual inspection plus elevation of a shop- built container and makes all sides of the container, including the bottom, visible during inspection.

Environmental Equivalence PMAA SETTLEMENT LANGUAGE: Visual inspection with placement of a barrier between the container and the ground, designed and operated in a way that ensures that any leaks are immediately detected. P.E. should begin by consulting appropriate industry standards, such as those listed in Steel Tank Institute Standard SP001 and API Standard 653.

Environmental Equivalence PMAA SETTLEMENT LANGUAGE : P.E. may wish to consult industry standards such as Underwriters Laboratory 142 or API Standard 650, Appendix J. Where a facility is considering environmental equivalence approach for containers resting on the ground, or presents risks for corrosion, the facility should first evaluate the condition of the container in accordance with good engineering practices, including seeking expert advice, where appropriate.

Other Considerations NFPA 30 Local Ordinances

Regulatory Deadline Certain facilities were required to comply by November 10, 2011.

Eco-Systems, Inc. Services SPCC Plan Review and Update Integrity Testing Program Set Up STI SP001 Certified Tank Inspections Consulting

Tank You!!!

Questions??? Thank You…..