FLOW CYTOMETRY Flow cytometry is a laser-based, biophysical technology employed in  cell counting,  cell sorting,  biomarker detection protein engineering.

Slides:



Advertisements
Similar presentations
Research Techniques Made Simple: Flow Cytometry Richard R
Advertisements

Cell Culture Facilities and Equipment Presenter: Dr. R. Rahbarghazi.
Introduction to Flow Cytometry
1 2 3 * Flow = cells in motion * Cyto = cell * Metry = measure * Measuring properties of cells while in a fluid stream * Flow Sorting * Sorting (separating)
What is Flow Cytometry? Introduction to Flow Cytometry
Geiger-Muller detector and Ionization chamber
Center of Excellence in Cancer Research Principles of flow cytometry
427 PHC.  Atomic emission spectroscopy (AES) is based upon emission of electromagnetic radiation by atoms.
CHAPTER 37 MLAB 1415 HEMATOLOGY JOANNA ELLIS, MLS(ASCP) Optical Light Scatter and Flow Cytometry.
Introduction To Flow Cytometry:
FACS Flourescens Activeted Cell s ortering. användningsområden.
PRINCIPLES OF MEASUREMENT AND INSTRUMENTATION EKT 112
COMPENSATION By: Ronald Mathieu. Compensation Why do we need compensation? –1) Because of long emission spectrum of dyes like FITC and PE.
FLOW CYTOMETRY Dr. MOHAMMED H SAIEMA LDAHR KAAU FACULTY OF APPLIED MEDICAL SCIENCES MEDICAL TECHNOLOGY DEPT. 2 ND YEAR MT INSTROMINTATION EXT
FLOW CYTOMETRY Dr. MOHAMMED H SAIEMA LDAHR KAAU FACULTY OF APPLIED MEDICAL SCIENCES MEDICAL TECHNOLOGY DEPT. 2 ND YEAR MT INSTROMINTATION EXT
Page 1 © J.Paul Robinson, Purdue University Cytometry Laboratories BMS 602 LECTURE 9.PPT BMS LECTURE 9 Flow Cytometry: Theory Hansen Hall,
Overview What is flow cytometry? Development of flow cytometry Components of Flow Typical applications Flow data.
FACSCalibur Training General Information The FACSCalibur is a useful analysis tool. The instrument has 2 lasers- 488 (primary) and 633 (secondary) that.
Basics of Flow Cytometry Holden Maecker. Outline Definitions, what can be measured by flow cytometry Fluidics: Sheath and sample streams, flow cells,
Introduction to Flow Cytometry
PPT 206 Instrumentation, Measurement and Control SEM 2 (2012/2013) Dr. Hayder Kh. Q. Ali 1.
FACS Flourescens Activeted Cell s ortering. användningsområden.
4-1 Chap. 7 (Optical Instruments), Chap. 8 (Optical Atomic Spectroscopy) General design of optical instruments Sources of radiation Selection of wavelength.
What is Flow Cytometry? Flow Cytometry uic Introduction to Flow Cytometry IGC Workshop IGC – Nov 12, 2009 Cell Sorting.
Antigen antibody reactions
Flourescence Activated Cell Sorting
Practical molecular biology PD Dr. Alexei Gratchev Prof. Dr. Julia Kzhyshkowska Prof. Dr. Wolfgang Kaminski.
Atomic Emission Spectroscopy
Cell viability studies Sepideh Khoshnevis. The Goal To distinguish live cells from dead and apoptotic cells in order to calculate the the percentage of.
Journal Meeting Jung-Yun Ko DNA Sequencing & ABI DNA Sequencer.
Flow Cytometry at Boston University Medical Campus Introduction to some methods that we offer Yan Deng (X4-5225), Gerald Denis (X4-1371),
Introduction To Flow Cytometry By Noha Kamel. Flow cytometry is a method of measuring multiple physical and chemical characteristics of particles by optical.
Dr Gihan Gawish Hydrodynamic focusing is a technique used to provide more accurate results from flow cytometers or Coulter counters for determining the.
Basic Principles in Flow Cytometry
 Flow cytometry is a technique for counting, examining, and sorting microscopic particles suspended in a stream of fluid.
1 Atomic Emission Spectroscopy Lecture Advantages of Plasma Sources 1.No oxide formation as a result of two factors including Very high temperature.
Basic Principles, Instrumentation, and Practices
Flow Cytometry Principles & practice of “Fluorescence Spectroscopy in Biological Diagnosis & Research” Dr.Hekmatimoghaddam Assistant professor of pathology.
FLOW CYTOMETRY  Definition: Measuring properties of cell as they flow in a fluid suspension across an illuminated light path.
Flow Cytometry Basic Training. What Is Flow Cytometry? Flow ~ cells in motion Cyto ~ cell Metry ~ measure Measuring properties of cells while in a fluid.
Flow Cytometry (FCM) Yun-Ju Lee September 13, 2002.
1 Flow Cytometry in the Clinical Laboratory Patricia Aoun, M.D., M. P. H. Jean Bailey, MT-ASCP Kellie Neth, MT-ASCP The Nebraska Medical Center.
2015 היחידה להפרדת תאים ד"ר דבי איצקוביץ'
Flow Cytometry Becton Dickinson Asia Limited Company.
Molecular Luminescence Spectroscopy
Quality Controls: Get your instruments under control!
Antigen-Antibody Interactions: Selected Tests (Contd.)
Chem. 133 – 2/11 Lecture. Announcements Lab today –Will cover 4 (of 8) set 2 labs (remainder covered on Tuesday) –Period 1 will extend one day Website/Homework.
Flow Cytometry. Applications FRET- protein interaction Membrane protein expression Intracellular protein expression Cell viability Ca 2+
Cell Sorting – The Basics RMS Flow Cytometer Course 2005
Chapter 1: The Nature of Analytical Chemistry
Identification of Cancer Stem Cells using Flow Cytometry Analysis تعيين الخلايا الجذعية السرطانية باستخدام تحليل التدفق الخلوي Dr. Ayat Al-Ghafari Biochemistry.
Fluorescence and Fluorochromes Peter O’Toole Tel:
FACSCalibur Training General Information
بسم الله الرحمن الرحیم.
Flow Cytometry Halima Moncrieffe, University College London, UK IL-17
Flowcytometry.
Flow Cytometry FACS (Fluorescence-Activated Cell Sorter)
Flow Cytometry Basic Training
TRENDS IN LABORATORY TESTING
FLOWCYTOMETRY.
COMPENSATION + FITC - PE - + PE - FITC - FITC detector FITC PE
Radiation Detectors : Detection actually means measurement of the radiation with its energy content and other related properties. The detection system.
Flow Cytometry and Sorting Part 1
Flow Cytometry and Sorting Part 3
Flow Cytometry Journal of Investigative Dermatology
Optical measurement.
The Art of Flow Cytometry
S.varasteh 10/11/2012.
Presentation transcript:

FLOW CYTOMETRY Flow cytometry is a laser-based, biophysical technology employed in  cell counting,  cell sorting,  biomarker detection protein engineering by suspending cells in a stream of fluid passing them by an electronic detection apparatus. It allows simultaneous multiparametric analysis of the physical and chemical characteristics of up to thousands of particles per second.

BD LASRII Sample loader Key pad/flow regulator waste Sheath fluid reservoir Sample loader waste Key pad/flow regulator

MAIN COMPONENTS FLUIDICS SYSTEM 2. SIGNAL PROCESSING detector and Analogue-to-Digital Conversion (ADC) system 3. AMPLIFICATION SYSTEM 4. COMPUTER FOR ANALYSIS OF THE SIGNALS.

FLUIDICS SYSTEM

Fluidics System One of the fundamentals of flow cytometry is the ability to measure the properties of individual particles. When a sample in solution is injected into a flow cytometer, the particles are randomly distributed in three-dimensional space. The sample must therefore be ordered into a stream of single particles that can be interrogated by the machine’s detection system. This process is managed by the fluidics system. Essentially, the fluidics system consists of a central channel/core through which the sample is injected, enclosed by an outer sheath that contains faster flowing fluid. As the sheath fluid moves, it creates a massive drag effect on the narrowing central chamber. This alters the velocity of the central fluid whose flow front becomes parabolic with greatest velocity at its center and zero velocity at the wall . The effect creates a single file of particles and is called hydrodynamic focusing. Under optimal conditions (laminar flow) the fluid in the central chamber will not mix with the sheath fluid.

OPTICS AND DETECTION SIZE Granularity

SIGNAL PROCESSING When light hits a photodetector a small current (a few microamperes) is generated. Its associated voltage has an amplitude proportional to the total number of light photons received by the detector. This voltage is then amplified by a series of linear or logarithmic amplifiers, and by analog to digital convertors (ADCs), into electrical signals large enough (5–10 volts) to be plotted graphically. Log amplification is normally used for fluorescence studies because it expands weak signals and compresses strong signals, resulting in a distribution that is easy to display on a histogram. Linear scaling is preferable where there is not such a broad range of signals e.g. in DNA analysis. The measurement from each detector is referred to as a ‘parameter’ e.g. forward scatter, side scatter or fluorescence. The data acquired in each parameter are known as the ‘events’ and refer to the number of cells displaying the physical feature or marker of interest.

OPTICS AND DETECTION After hydrodynamic focusing, each particle passes through one or more beams of light. Light scattering or fluorescence emission (if the particle is labeled with a fluorochrome) provides information about the particle’s properties. The laser and the arc lamp are the most commonly used light sources in modern flow cytometry. Lasers produce a single wavelength of light (a laser line) at one or more discreet frequencies (coherent light). Arc lamps tend to be less expensive than lasers and exploit the color emissions of an ignited gas within a sealed tube. However, this produces unstable incoherent light of a mixture of wavelengths, which needs subsequent optical filtering.

Light that is scattered in the forward direction, typically up to 20 degrees offset from the laser beam’s axis, is collected by a lens known as the forward scatter channel (FSC). The FSC intensity roughly equates to the particle’s size and can also be used to distinguish between cellular debris and living cells. Light measured approximately at a 90 degrees angle to the excitation line is called side scatter. The side scatter channel (SSC) provides information about the granular content within a particle. Both FSC and SSC are unique for every particle, and a combination of the two may be used to differentiate different cell types in a heterogeneous sample.

Fluorescence measurements taken at different wavelengths can provide quantitative and qualitative data about fluorochrome-labeled cell surface receptors or intracellular molecules such as DNA and cytokines. Flow cytometers use separate fluorescence (FL-) channels to detect light emitted. The number of detectors will vary according to the machine and its manufacturer. Detectors are either silicon photodiodes or photomultiplier tubes (PMTs). Silicon photodiodes are usually used to measure forward scatter when the signal is strong. PMTs are more sensitive instruments and are ideal for scatter and fluorescence readings. Modern instruments usually have multiple lasers and fluorescence detectors. The current record for a commercial instrument is ten lasers and 18 fluorescence detectors. Increasing the number of lasers and detectors allows for multiple antibody labeling, and can more precisely identify a target population by their phenotypic markers.

Electrostatic Cell Sorting A major application of flow cytometry is to separate cells according to subtype or epitope expression for further biological studies. This process is called cell sorting or FACS™ analysis. After the sample is hydrodynamically focused, each particle is probed with a beam of light. The scatter and fluorescence signal is compared to the sort criteria set on the instrument. If the particle matches the selection criteria, the fluid stream is charged as it exits the nozzle of the fluidics system. Electrostatic charging actually occurs at a precise moment called the ‘break-off point’, which describes the instant the droplet containing the particle of interest separates from the stream.

To prevent the break-off point happening at random distances from the nozzle and to maintain consistent droplet sizes, the nozzle is vibrated at high frequency. The droplets eventually pass through a strong electrostatic field, and are deflected left or right based on their charge (Figure 4). The speed of flow sorting depends on several factors including particle size and the rate of droplet formation. A typical nozzle is between 50–70 µM in diameter and, depending on the jet velocity from it, can produce 30,000–100,000 droplets per second, which is ideal for accurate sorting. Higher jet velocities risk the nozzle becoming blocked and will also decrease the purity of the preparation.

GATING The data generated by flow-cytometers can be plotted in a single dimension, to produce a histogram, or in two-dimensional dot plots or even in three dimensions. The regions on these plots can be sequentially separated, based on fluorescence intensity, by creating a series of subset extractions, termed "gates." Specific gating protocols exist for diagnostic and clinical purposes especially in relation to hematology. The plots are often made on logarithmic scales. Because different fluorescent dyes' emission spectra overlap, signals at the detectors have to be compensated electronically as well as computationally

Data accumulated using the flow cytometer can be analyzed using software, e.g., WinMDI, Flowing Software, and web-based Cytobank (all freeware), FCS Express, Flowjo, FACSDiva, CytoPaint (aka Paint-A-Gate),VenturiOne, CellQuest Pro, Infinicyt or Cytospec. Once the data are collected, there is no need to stay connected to the flow cytometer. For this reason, analysis is most often performed on a separate computer. This is especially necessary in core facilities where usage of these machines is in high demand.

FLUORESCENT LABELS A wide range of fluorophores can be used as labels in flow cytometry. Fluorophores, or simply "fluors", are typically attached to an antibody that recognizes a target feature on or in the cell; they may also be attached to a chemical entity with affinity for the cell membrane or another cellular structure. Each fluorophore has a characteristic peak excitation and emission wavelength, and the emission spectra often overlap. Consequently, the combination of labels which can be used depends on the wavelength of the lamp(s) or laser(s) used to excite the fluorochromes and on the detectors available. The maximum number of distinguishable fluorescent labels is thought to be 17 or 18, and this level of complexity necessitates laborious optimization to limit artifacts, as well as complex  algorithms to separate overlapping spectra.

APPLICATIONS Measurable parameters his list is very long and constantly expanding. used for confirming diagnosis of chronic lymphocytic leukemia volume and morphological complexity of cells cell pigments such as chlorophyll or phycoerythrin total DNA content (cell cycle analysis, cell kinetics, proliferation, ploidy, aneuploidy, endoreduplication, etc.) total RNA content DNA copy number variation (by Flow-FISH or BACs-on-Beads technology) chromosome analysis and sorting (library construction, chromosome paint) protein expression and localization Protein modifications, phospho-proteins transgenic products in vivo, particularly the Green fluorescent protein or related Fluorescent Proteins cell surface antigens (Cluster of differentiation (CD) markers) intracellular antigens (various cytokines, secondary mediators, etc.) nuclear antigens enzymatic activity pH, intracellular ionized calcium, magnesium, membrane potential membrane fluidity apoptosis (quantification, measurement of DNA degradation, mitochondrial membrane potential, permeability changes, caspase activity) cell viability monitoring electropermeabilization of cells oxidative burst characterising multidrug resistance (MDR) in cancer cells glutathione various combinations (DNA/surface antigens, etc.) cell adherence (for instance pathogen-host cell adherence)