Data Analysis and Present Status of the MuCap Experiment Steven Clayton* University of Illinois *Present address: LANL Outline: 1)Experimental overview.

Slides:



Advertisements
Similar presentations
HARP Anselmo Cervera Villanueva University of Geneva (Switzerland) K2K Neutrino CH Meeting Neuchâtel, June 21-22, 2004.
Advertisements

A.Vorobyov on behalf of MuCap collaboration Determination of the nucleon’s pseudoscalar form factor in the MuCap experiment HSQCD 2014 Gatchina
Muon Capture on the Proton Final results from the MuCap experiment Muon Capture on the Proton Final results from the MuCap experiment gPgP Peter Winter.
Precision Measurement of Muon Capture on the Proton “  Cap experiment”  - + p   + n  PSI Supported by Paul Scherrer.
July 2001 Snowmass A New Measurement of  from KTeV Introduction The KTeV Detector  Analysis of 1997 Data Update of Previous Result Conclusions.
Recent Electroweak Results from the Tevatron Weak Interactions and Neutrinos Workshop Delphi, Greece, 6-11 June, 2005 Dhiman Chakraborty Northern Illinois.
Muon Capture on the Deuteron Motivation for a new Experiment B e r n h a r d L a u s s U C B e r k e l e y for the MuCAP Collaboration Petersburg Nuclear.
1 Peter Kammel for the MuSun Collaboration Muon Capture on the Deuteron The MuSun Experiment BV39, Feb 21, 08.
Precision Muon Physics Group muon capture on proton  - + p   + n  to 1 % muon capture on proton  - + p   + n  to 1 % Nucleon form factors, chiral.
Precision Measurement of Muon Capture on the Proton “  Cap experiment”  - + p   + n Petersburg Nuclear Physics Institute (PNPI), Gatchina,Russia Paul.
New Precision Determination of g p and G F, the MuXperiments at PSI Bernhard Lauss University of Berkeley on behalf of the MuCAP and MuLAN.
Muon Capture as a Probe of the Nucleon’s Axial Structure – the  Cap Experiment Peter Kammel University of Illinois at Urbana-Champaign
Peter Kammel University of Illinois at Urbana-Champaign MuCap Collaboration V.A. Andreev,
Study of two pion channel from photoproduction on the deuteron Lewis Graham Proposal Phys 745 Class May 6, 2009.
1 Measurement of the Rate of Muon Capture in Hydrogen Gas and Determination of the Proton’s Pseudoscalar Coupling Steven Clayton Dissertation Talk June.
MuCap High-Precision Measurement of Muon Capture on the Proton BVR35 Progress report presented by Claude Petitjean, PSI 12 Febuary 2004
MuCap: From first results to final precision on determining g P Brendan Kiburg 2008 APS April Meeting April 12 th, 2008.
Measurement of the Positive Muon Lifetime to 1 ppm David Webber Preliminary Examination March 31, 2005.
Experiment Rosen07: Measurement of R =  L /  T on Deuterium in the Nucleon Resonance Region. 1  Physics  Data Analysis  Cross Section calculation.
Measurements of F 2 and R=σ L /σ T on Deuteron and Nuclei in the Nucleon Resonance Region Ya Li January 31, 2009 Jlab E02-109/E (Jan05)
Experiment Rosen07: Measurement of R =  L /  T on Deuterium in the Nucleon Resonance Region.  Physics  Experiment Setup  HMS Detectors  Calibrations.
W properties AT CDF J. E. Garcia INFN Pisa. Outline Corfu Summer Institute Corfu Summer Institute September 10 th 2 1.CDF detector 2.W cross section measurements.
Precision Muon Capture on the Proton and Very Light Nuclei 1 Peter Kammel Department of Physics and Center for Experimental Nuclear Physics and Astrophysics,
A determination of the formation rate of muonic hydrogen molecules from the MuCap experiment Sara Anita Knaack Final Exam June 25.
25/07/2002G.Unal, ICHEP02 Amsterdam1 Final measurement of  ’/  by NA48 Direct CP violation in neutral kaon decays History of the  ’/  measurement by.
Direct photons at low p t measured in PHENIX D.Peressounko RRC “Kurchatov institute” for the PHENIX collaboration.
Precision Muon Capture at PSI 1 Peter Kammel Department of Physics and Center for Experimental Nuclear Physics and Astrophysics, University of Washington.
Muon PSI Peter Winter University of Washington gPgP L 1A / d R.
Peter Kammel First Results from the New Muon Lifetime Experiments at PSI GFGF gPgP L 1A MuCap “MuSun” project MuLan.
David M. Webber University of Illinois at Urbana-Champaign For the MuLan Collaboration A new determination of the positive muon lifetime to part per million.
Measurement of F 2 and R=σ L /σ T in Nuclei at Low Q 2 Phase I Ya Li Hampton University January 18, 2008.
Muon Capture in Hydrogen and Deuterium EXA08 int. conference on exotic atoms & related topics Vienna Sept presentation by Claude Petitjean representing.
Measurement of Vus. Recent NA48 results on semileptonic and rare Kaon decays Leandar Litov, CERN On behalf of the NA48 Collaboration.
Results from RENO Soo-Bong Kim (KNRC, Seoul National University) “17 th Lomosonov Conference on Elementary Particle Physics” Moscow. Russia, Aug ,
Electroweak and Related Physics at CDF Tim Nelson Fermilab on behalf of the CDF Collaboration DIS 2003 St. Petersburg April 2003.
Unblinding the MuCap experiment the final results of μp capture rate Λ S and of electro-weak coupling constant g P LTP Seminar April 23, 2012 Claude Petitjean.
David M. Webber For the MuLan Collaboration University of Wisconsin-Madison Formerly University of Illinois at Urbana-Champaign August 12, 2011 A part-per-million.
Muon Capture on the Proton: First Physics Results from the MuCap Experiment Steven Clayton University of Illinois Urbana Champaign
1 Fukutaro Kajihara (CNS, University of Tokyo) for the PHENIX Collaboration Heavy Quark Measurement by Single Electrons in the PHENIX Experiment.
00 Cooler CSB Direct or Extra Photons in d+d  0 Andrew Bacher for the CSB Cooler Collaboration ECT Trento, June 2005.
Muon Capture on the Deuteron – MuSun Experiment  + d  n + n +  + d  n + n + model-independent connection via EFT.
Peter Kammel Muon Capture and the Nucleon’s Axial Structure First Results and Future Plans of the MuCap Experiment GFGF gPgP L 1A MuCap “MuSun” project.
1 Constraining ME Flux Using ν + e Elastic Scattering Wenting Tan Hampton University Jaewon Park University of Rochester.
1 Guannan Xie Nuclear Modification Factor of D 0 Mesons in Au+Au Collisions at √s NN = 200 GeV Lawrence Berkeley National Laboratory University of Science.
T2K Status Report. The Accelerator Complex a Beamline Performance 3 First T2K run completed January to June x protons accumulated.
Recent Results from RENO NUFACT2014 August. 25 to 30, 2014, Glasgow, Scotland, U.K. Hyunkwan Seo on behalf of the RENO Collaboration Seoul National University.
 0 life time analysis updates, preliminary results from Primex experiment 08/13/2007 I.Larin, Hall-B meeting.
Ibrahim H. Albayrak, Hampton University Group Meeting Experiment Rosen07: Measurement of R =  L /  T on Deuterium in the Nucleon Resonance Region. 
Heavy stable-particle production in NC DIS with the ZEUS detector Takahiro Matsumoto, KEK For the ZEUS collaboration.
Stano Tokar, slide 1 Top into Dileptons Stano Tokar Comenius University, Bratislava With a kind permissison of the CDF top group Dec 2004 RTN Workshop.
Belle General meeting Measurement of spectral function in the decay 1. Motivation 2. Event selection 3. mass spectrum (unfolding) 4. Evaluation.
ПРЕЦИЗИОННОЕ ИЗМЕРЕНИЕ СКОРОСТИ ЗАХВАТА МЮОНА В ВОДОРОДЕ И ОПРЕДЕЛЕНИЕ ПСЕВДОСКАЛЯРНОГО ФОРМ ФАКТОРА ПРОТОНА g P PNPI participants in MuCAP collaboration*)
Paolo Massarotti Kaon meeting March 2007  ±  X    X  Time measurement use neutral vertex only in order to obtain a completely independent.
Impurities in MuCAP Bernhard Lauss Berkeley Analysis Meeting Feb 27 - Mar 1, 2006.
Muon Capture: Status and Prospects 1 Peter Kammel Department of Physics and Center for Experimental Nuclear Physics and Astrophysics, University of Washington.
Peter Kammel Fundamental Constants Basic QCD Symmetries “Calibrating the Sun” MuCap MuSun MuLan FAST Muon Lifetime Programme at PSI.
The MuCap experiment – final results on μp capture rate Λ S and pseudoscalar coupling g P INPC 2013 Firence Italia June 2 - 7, 2013 Claude Petitjean on.
Measurement of the Positive Muon Lifetime and Determination of the Fermi Constant to Part-per-Million Precision David Hertzog University of Washington*
Double Chooz Experiment Status Jelena Maricic, Drexel University (for the Double Chooz Collaboration) September, 27 th, SNAC11.
1 Peter Kammel Muon Capture and Basic Solar Neutrino Reactions The New MuSun Experiment Muon Capture and Basic Solar.
Kevin Lynch MuLan Collaboration Boston University CIPANP 2006 A new precision determination of the muon lifetime Berkeley, Boston, Illinois, ITU, James.
David M. Webber For the MuLan Collaboration University of Wisconsin-Madison Formerly University of Illinois at Urbana-Champaign DPF Meeting, August 2011.
IBD Detection Efficiencies and Uncertainties
High-Precision Measurement of Muon Capture on the Proton
The MuCap experiment: A measurement of
Muon Capture on the Deuteron The MuSun Experiment
First results from the MuLan and MuCap experiments
High Precision Measurement of Muon Capture on the Proton
p0 life time analysis: general method, updates and preliminary result
Precision Measurement of Singlet mp Capture in a Hydrogen TPC
Presentation transcript:

Data Analysis and Present Status of the MuCap Experiment Steven Clayton* University of Illinois *Present address: LANL Outline: 1)Experimental overview 2)Data analysis challenges 3)Some systematics and consistency checks 4)First physics results and context 5)MuCap improvements since first physics results

2 Experimental Challenges 2) H 2 must be pure chemically (c O,c N < 10 ppb) and isotopically (c d < 1 ppm). 3) All neutral final state of muon capture is difficult to detect (would require absolute calibration of neutron detectors, accurate subtraction of backgrounds). 1) Unambiguous interpretation requires low-density hydrogen target to reduce  -molecular formation.  p diffusion into Z > 1 material.  liquid (LH 2 )gas (1% LH 2 density)  stop distribution broad  stop distribution container wall

3 slope =    ≡ 1/    TT Log N events  Cap Method: Lifetime Technique  Cap measures the lifetime of  - in 10 bar Hydrogen. -- e-e- T zero T electron slope =    ≡ 1/    Data Acquisition TT Repeat times for a 10 ppm precision lifetime measurement. H2H2       S   S to 1% precision Compare to  + lifetime:

4  Cap Detailed Diagram  Tracking of Muon to Stop Position in Ultrapure H 2 Gas  Tracking of Decay Electron

MuCap Exptl./Data analysis considerations Precision muon lifetime experiment –Avoid unintended mu-e correlations, “early-to-late” effects. –Avoid distortions to lifetime spectrum –Avoid detector dead time effects –Avoid analyzer bias Capture on Z>1 materials must be avoided –Fiducial cut –μ+p scatters vs. “delta electrons” –Diffusion (μp and μd) Z>1 impurities in the protium gas –Identify impurity concentration, effect on lifetime 5 Pileup protection (1 muon at a time) Separate μ/e detectors; Dead-time-free DAQ Blinded time base Robust “muon” definition Impact parameter cut studies Z>1 captures within TPC have unique signature. Calibration data  Z>1 capture detection efficiency

6 p Tracking in the Time Projection Chamber E e-e- z x y -- 1)  entrance, Bragg peak at stop. 2) ionization electrons drift to MWPC. 3) projection onto zx plane from anodes and strips. 4) projection onto zy plane from anodes and drift time. 5) projection onto zy plane from strips and drift time.

7 Impact Parameter Cuts e  stop position interpolated e-track aluminum pressure vessel  Stop Position  -e Vertex Cut (also known as  -e vertex cuts) b (electron view) The impact parameter b is the distance of closest approach of the e-track to the  stop position. point of closest approach Scatter in wall

8 Lifetime Spectra Normalized residuals (“pull”)

9 Internal corrections to  - (statistical uncertainty of  - : 12 s -1 )

10 In situ detection of Z > 1 captures  Beam  Stop Z>1 Capture (recoil nucleus) Capture Time TPC (side view)

11 The final Z > 1 correction  Z is based on impurity-doped calibration data. 0 Production Data Calibration Data (oxygen added to production gas) Extrapolated Result Observed capture yield Y Z Some adjustments were made because calibration data with the main contaminant, oxygen (H 2 O), were taken in a later running period (2006). Lifetime deviation is linear with the Z>1 capture yield.

12 Internal corrections to  - (statistical uncertainty of  - : 12 s -1 )

13 Residual deuterium content is accounted for by a zero-extrapolation procedure. d Concentration (c d )0 Production Data (d-depleted Hydrogen) Calibration Data (Natural Hydrogen) Extrapolated Result from fits to data (f = N e - t + B) This must be determined.

14 c d Determination: Data Analysis Approach  Stop Position  Decay Position  d Diffusion Path  -e Vertex Cut  d can diffuse out of acceptance region:  signal proportional to number of  d, and therefore to c d. Impact Parameter Cut b cut [mm] [s -1 ] Fits to Lifetime Spectra diffusion “signal” for 40-mm cut c d (Production) c d (Natural H2) = ± *after accounting for  p diffusion (electron view) natural hydrogen (c d  120 ppm) d-doped target (c d  17 ppm) production target (c d ~ 2 ppm) Agrees with atomic mass spectrometry measurement of c D

15  p Diffusion Effect  Stop Position  Decay Position  p Diffusion Path  -e Vertex Cut (b cut ) Impact Parameter Distribution F(b) b (mm) b cut early decays later decays b (ideal) b (obs.) Later decays are less likely than early decays to pass the impact parameter cut. The effect is calculated based on: 1) the observed F(b), 2) a thermal diffusion model, 3) the requirement of consistency of the c d ratio vs. b cut (prev. slide). (electron view)

16 Consistency Checks lifetime vs. variations in parameters not expected to change the results

17 Lifetime vs eSC segment Beam view of MuCap detector eSC Sum over all segments

18 Lifetime vs. Non-Overlapping Fiducial Volume Shell Included in standard fiducial cut z y Example TPC fiducial volume shells (red areas) outside the standard fiducial cut outer inner outerinner

19 Fit Start Time Scan

20 Fit Stop Time Scan

21 Lifetime vs. Chronological Subdivisions Oct. 9, 2004Nov. 4, 2004

22 Czarnecki, Marciano,Sirlin, PRL 99 (2007) PRL 99, (2007)  S MuCap =  13.7 stat  10.7 sys s -1 Average of HBChPT calculations of  S : g P = 7.3 ± 1.1 Apply new rad. correction (2.8%): further sub percent theory required with   + from PDG and MuLan  s and g P Results 07 MuCap Result 07 Theory 07 Pseudoscalar coupling from MuCap 07  S Theory = s -1

23 Updated g P vs. op MuCap 2007 result (with g P to 15%) is consistent with theory. This is the first precise, unambiguous experimental determination of g P (contributes 3% uncertainty to g p MuCap )

24 Several upgrades should lead to a 3-fold improved precision in runs Source 2007 Uncertainty (s -1 ) Projected Final Uncertainty (s -1 ) Statistical Z > 1 impurities5.02 µd diffusion µp diffusion0.5 µ + p scattering31 µ pileup veto eff.31 Analysis Methods52 Muon kinetics5.82 Systematic Total

25 Muon-On-Demand concept Muon-On-Demand Beamline Single muon requirement (to prevent systematics from pile-up) limits accepted  rate to ~ 7 kHz, while PSI beam can provide ~ 70 kHz - kV kV Kicker Plates 50 ns switching time  detector TPC Fig will be improved ~3 times higher rate dc kicked 2-Dec-2005  Lan kicker TRIUMF rf design

26 Several upgrades should lead to a 3-fold improved precision in runs Source 2007 Uncertainty (s -1 ) Projected Final Uncertainty (s -1 ) Statistical Z > 1 impurities5.02 µd diffusion µp diffusion0.5 µ + p scattering31 µ pileup veto eff.31 Analysis Methods52 Muon kinetics5.82 Systematic Total

HD separation column constructed in Gatchina & PSI, tested & operated in March/April 2006 principle: - H 2 gas circulates from bottom to top & gets liquified at the cold head - liquid droplets fall down & vaporize  gas phase depleted from D - the D-enriched liquid H 2 at the bottom is slowly removed results of AMD analysis at ETHZ: protium in 2004/5: c d = (1.45±0.15)10 -6 protium used in 2006 after HD separation: c d < 6 * (6 ppb)

28 Several upgrades should lead to a 3-fold improved precision in runs Source 2007 Uncertainty (s -1 ) Projected Final Uncertainty (s -1 ) Statistical Z > 1 impurities5.02 µd diffusion µp diffusion0.5 µ + p scattering31 µ pileup veto eff.31 Analysis Methods52 Muon kinetics5.82 Systematic Total

29 Summary and Outlook MuCap –First precise g P with clear interpretation –Consistent with ChPT expectation, clarifies long-standing QCD puzzle –Factor 3 additional improvement on the way Final Precision of g P determination Synergy with MuLan gPgP MuCap 07 MuCap final 09?  S /  S +  RC +  g A exp Watch new  n experiments: g A to explain Serebrov et al. would shift predicted  S by ~ 0.7 %

30 “Calibrating the Sun” via Muon Capture on the Deuteron   + d  n + n +   + d  n + n + Motivation for the MuSun Experiment: First precise measurement of basic Electroweak reaction in 2N system, Impact on fundamental astrophysics reactions ( ’s in SNO, pp fusion) Comparison to modern high-precision calculations NEW PROJECT

31 MuCap Collaboration V.A. Andreev, T.I. Banks, B. Besymjannykh, L. Bonnet, R.M. Carey, T.A. Case, D. Chitwood, S.M. Clayton, K.M. Crowe, P. Debevec, J. Deutsch, P.U. Dick, A. Dijksman, J. Egger, D. Fahrni, O. Fedorchenko, A.A. Fetisov, S.J. Freedman, V.A. Ganzha, T. Gorringe, J. Govaerts, F.E. Gray, F.J. Hartmann, D.W. Hertzog, M. Hildebrandt, A. Hofer, V.I. Jatsoura, P. Kammel, B. Kiburg, S. Knaak, P. Kravtsov, A.G. Krivshich, B. Lauss, M. Levchenko, E.M. Maev, O.E. Maev, R. McNabb, L. Meier, D. Michotte, F. Mulhauser, C.J.G. Onderwater, C.S. Özben, C. Petitjean, G.E. Petrov, R. Prieels, S. Sadetsky, G.N. Schapkin, R. Schmidt, G.G. Semenchuk, M. Soroka, V. Tichenko, V. Trofimov, A. Vasilyev, A.A. Vorobyov, M. Vznuzdaev, D. Webber, P. Winter, P. Zolnierzcuk Petersburg Nuclear Physics Institute (PNPI), Gatchina, Russia Paul Scherrer Institute (PSI), Villigen, Switzerland University of California, Berkeley (UCB and LBNL), USA University of Illinois at Urbana-Champaign (UIUC), USA Université Catholique de Louvain, Belgium TU München, Garching, Germany University of Kentucky, Lexington, USA Boston University, USA

World data on g P 32

33 MuCap 07 Expectations for Final MuCap Precision MuCap 07 MuCap final 09? big exp. improvement 0.7 % sub-percent theory needed ? PDG g a contributes 0.36 % Rad. corr. 0.4 %  g P vs  S /  S Allowed g P vs g A MuCap 09? “g a to explain Serebrov et al” g a PDG

34 µ p + d   d + p (134 eV)  large diffusion range of  d < 1 ppm isotopic purity required Record Isotopic Purity Achieved Diagnostic: vs.  -e vertex cut 2007 Result Data: c d = 1.49 ± 0.12 ppm AMS: c d = 1.44 ± 0.15 ppm On-site isotopic separator c d < ppm ! World record AMS, ETH Zurich e-e- e-e- pp p dp d or to wall  -e impact par cut AMS, ETH Zurich

35 CHUPS FADC upgrade on all TPC channels Z>1 Impurities Reduced and Measured Circulating Hydrogen Ultrahigh Purification System (CHUPS) Gas chromatography c N, c O < 5 ppb, c H2O <10 ppb CRDF support Diagnostic in TPC Imp. Capture x z t

Argon doped run for Λ ppμ measurement e - time spectrum yields λ e neutron time spectrum Ar capture time spectrum - protium run with 20 ppm Argon doping - electron spectrum 5.5*10 8 events - neutrons from μAr capture 3*10 5 events - tpc data from μ-Ar capture 4*10 6 evts combined analysis of time spectra yields λ capt Ar, λ transfer pAr, λ pp μ to ~2% reduces error of Λ S to 0.5 s -1 ! (analysis in progress at Urbana)

37 slope =    ≡ 1/    TT Log N events  Cap Method: Lifetime Technique  Cap measures the lifetime of  - in 10 bar Hydrogen. -- e-e- T zero T electron slope =    ≡ 1/    Data Acquisition TT Repeat times for a 10 ppm precision lifetime measurement. H2H2       S   S to 1% precision Compare to  + lifetime:

38 3D tracking w/o material in fiducial volume 10 bar ultra-pure hydrogen, 1% LH kV/cm drift field >5 kV on 3.5 mm anode half gap bakable glass/ceramic materials Time Projection Chamber (TPC) Beam ViewSide View  Beam  Stop y xz y

39 p -- Observed muon stopping distribution E e-e- 3D tracking w/o material in fiducial volume 10 bar ultra-pure hydrogen, 1% LH kV/cm drift field >5 kV on 3.5 mm anode half gap bakable glass/ceramic materials Time Projection Chamber (TPC)

40  Cap Method: Clean  Stop Definition Each muon is tracked in a time projection chamber. -- e-e- T zero T electron Data Acquisition TT Only muons stopped well-away from non- hydrogen are accepted. H2H2 anodes strips

41  Cap Detailed Diagram  Tracking of Muon to Stop Position in Ultrapure H 2 Gas  Tracking of Decay Electron

42 Commissioning and First Physics Data in 2004 (Target Pressure Vessel, Pulled Back)

43  d Diffusion into Z > 1 Materials  d scattering in H 2 displacement (from  - stop position) at time of decay Ramsauer-Townsend minimum in the scattering cross section  d can diffuse ~10 cm before muon decay, possibly into walls. MuCap uses deuterium-depleted hydrogen (c d  1.5 ppm). Residual effects are accounted for by a zero-extrapolation. (Monte Carlo)

44 Lifetime vs. e-definition All e acceptedOne e gated b<12cmno b-cutb<12cmno b-cut CathOR CathAND eSC Only CathOR CathAND CathOR CathAND eSC Only CathOR CathAND (impact par. cut) (treatment of detector planes) (e-multiplicity)

45 Impurity correction scales with Z > 1 capture yield.  Z =  Z /Y Z is similar for C, N, and O. We can correct for impurities based on the observed Z > 1 capture yield, if we know the detection efficiency  Z.

46 MuCap  S from the   lifetime   bound-state effect  + decay rate molecular formation Averaged with UCB result gives

47 Unambiguous interpretation –capture mostly from F=0  p state at 1% LH 2 density Lifetime method –10 10   →e decays –measure   to 10ppm    S = 1/   - 1/    to 1% Clean  stop definition in active target (TPC) to avoid  Z capture, 10 ppm level Ultra-pure gas system and purity monitoring to avoid:  p + Z   Z + p, ~10 ppb impurities Isotopically pure “protium” to avoid  p + d   d + p, ~1 ppm deuterium  diffusion range ~cm  Cap Experimental Strategy fulfill all requirements simultaneously unique  Cap capabilities

48 c D Monitoring: External Measurement Measurements with ETH Zürich Tandem Accelerator: 2004 Production Gas, c D = 1.44 ± 0.13 ppm D 2005 Production Gas, c D = 1.45 ± 0.14 ppm D 2006 Production Gas (isotope separation column), c D < 0.06 ppm D The “Data Analysis Approach” gives a consistent result: 2004 Production Gas, c D = ( ± ) × (122 ppm D) = 1.53 ± 0.12 ppm