Single Phase IEC and EATS Distribution Transformers

Slides:



Advertisements
Similar presentations
Chapter 12 Transformers. Chapter 12 Transformers.
Advertisements

Where does 120/240 volts come from?. Transformer on the Utility Pole 3 wires to your residence.
Siemens Building Technologies Building Technologies Variable Frequency Drives Harmonics Overview.
TESTING, MAINTENANCE & PROTECTION OF DISTRIBUTION TRANSFORMERS
© Copyright year ABB. All rights reserved /1/2015 VBF OUTDOOR VACUUM CIRCUIT BREAKER 36kV PRODUCT INFORMATION.
INTRODUCTION OF ULTRA-HIGH VOLTAGE (UHV) 1000 kV AC TRANSFORMER
Copyright © 2011 Rockwell Automation, Inc. All rights reserved. Insert Photo Here OneGear™ 7.2kV Motor Control Center.
OHB Outdoor sulphur Hexafluoride circuit-Breaker
LP33 Series UPS kVA 400Vac/CE
Lecture 26 Distribution Systems Professor Tom Overbye Department of Electrical and Computer Engineering ECE 476 POWER SYSTEM ANALYSIS.
Mr. Harethe El Ouadhane IEC member for IEC MT14. |Infrastructure Business | Germany | Test Engineer & Expert (Internal Arc, Making, Breaking.
ABB - 1- ABB ABB Load Interrupter Switchgear. ABB - 2 ABB Contents Introduction to Load Interrupter Switchgear What, Where, Why ABB Technical Offering.
Dry type transformers Zaragoza Traction application
Circulating Current – load switch open. Circulating Current load switch closed.
Universal College of Engineering & Technology
GE Consumer & Industrial Multilin  Single & Three phase models  Specific mount CT’s  Rectangular & Toroidial models  Plastic case & cast models  Multi.
1 Position Paper on IEEE Task Force on Insulator Icing Test Methods Item # 5 Power Supply Requirements By Rudi F. Kremer Vice President.
Dry type transformers Zaragoza Accessories and options
Transformer.
Dry-type transformers HiDry72
Dry type transformers Zaragoza Drives application
Frankfurt (Germany), 6-9 June 2011 SINGH– US – Session 1 – 0952 Dry-type Transformer for Pole Mounted Application.
Three Phase Power Three Phase Motors
Transformer heat run test: The loading back method IEEE transformer Committee meeting, March 2008 By Marcel Fortin, eng., Consultant.
Safety Testers (plus more) from Dranetz and Gossen Metrawatt General Presentation.
Overvoltage Protection, A. Zeddam, Dakar, Senegal, 25 March 2015 ITU Regional Standardization Forum For Africa Dakar, Senegal, March 2015 Overview.
Medium Voltage Fuses. 2 Why do we need Medium Voltage Fuses? Medium Voltage fuses are used the protection for voltage transformers and medium voltage.
Chapter 2 Transformers.
2. Terms and definitions1 # Terms and Definitions # Voltage Sags and Interruptions.
Transformer.
MNS Sprint - A Market Driven Solution
Transformer Taking the ratio of the two equations
Capacitor Training Duck River Electric Membership Corp. Doug Simpson.
Source of Energy. Vision Mission It is Power Consultancy's mission to provide the finest energy solutions. Through careful analysis, attentive customer.
Copyright © 2011 Rockwell Automation, Inc. All rights reserved. Insert Photo Here OneGear™ SMC™ Flex Controller kV.
Reyrolle LMT Breaker Retrofit BU PPMV – PG Service Marketing and Sales
Modeling of Power Transformers A Static Device. Transformers The transformer enables us to utilize different voltage levels across the system for the.
Transformer condition assessment with an integrated test van
EECE 887 Distribution System Engineering CHAPTER 1 Power Delivery Systems.
CONTENS 1. Production Capacity 2. Production Range
S. MELQUIOND France Session 1 – Block 1 – Question 1- 5 Barcelona May Question 1-5 Is the transformer protection by mean of protection switch.
RECENT TRENDS IN POWER SYSTEMS
12 good reasons to buy an ABB TrafoStar™ transformer
E Control Devices have a wide range of Latching Relays. The range of latching includes Relays, 16 Amp Latching Relays, 30Amp Latching Relays, 80 Amp Latching.
AUTOMATIC CIRCUIT RECLOSER
Single Phase and three Phase Distribution Substation
Md.Hamidul Haque ID: Prog:BSEEE SEC:E/3 International University of Business Agriculture and Technology (IUBAT )
Mehran University Of Engineering & Technology, SZAB Khairpur Mirs Campus ENGR. AHSANULLAH MEMON LECTURER DEPARTMENT OF ELECTRICAL ENGINEERING MUCET KHAIRPUR.
ET 332b Ac Motors, Generators and Power Systems 1 Lesson 11_et332b.pptx.
HNC/D Engineering Science
PE Systems Pvt. Ltd. Bangalore
Introduction High Voltage!!.
ONLOAD TAP CHANGING TRANSFORMER
Sensor presentation.
EPOX PRODUCTS.
SUB-STATIONS.
12 good reasons to buy an ABB TrafoStar™ transformer
Testing of Transformers
Transformer heat run test: The loading back method
3-Phase Transformer Construction, Principal, Working, Operation Advantages Over 1-Phase Transformer Introduction Advatages Construction Principal Working.
A presentation on Measurement of Winding Resistance and Insulation Resistance of 3 Phase 11 kV/ 433 V, 16KVA Oil cooled type Transformer PRESENTED BY:
Sensor presentation.
المحولات Transformers
Oil-tight MV fuse CEF-OT with TPC bushings
Lesson 11: Transformer Name Plate Data and Connections
3-Phase Transformer Construction, Principal, Working, Operation Advantages Over 1-Phase Transformer Introduction Advatages Construction Principal Working.
Transformer Factory (Cast Resin)
Transformer Impedance
CIRCUIT BREAKERS E. Chikuni. Circuit Breakers Mechanical Switches capable of making and breaking currents under normal circuit conditions and for a specified.
Biosco: MV/LV prefabricated substations IEC Presentation of the standard Safety is a choice.
Presentation transcript:

Single Phase IEC and EATS Distribution Transformers INTRODUCTION TO RANGE Single Phase IEC and EATS Distribution Transformers

INDEX Range Standard Features Optional Features Routine Tests Type Tests Why use ABB?

RANGE Single phase 15kVA to 100kVA Smaller kVA available on request Voltage level - primary voltage of up to 36kV Units manufactured to IEC, EATS or Special requirements

STANDARD FEATURES Sealed or free breathing tank Hot dip galvanised tank Lifting lugs Rating plate and connection plate Earth tag Upper and lower pole mounting brackets

OPTIONAL FEATRUES Lid or turret mounted bushings 2 or 3 wire arrangement Internal HT fuses Single or dual ratio Off circuit tap switch or internal link board Arcing horns Surge arresters Oil level on free breathing units

ROUTINE TESTS Each transformer produced is routine tested in accordance with IEC 76 The tests performed are: Winding resistance Voltage ratio and phase displacement Short-circuit impedance and load loss No-load loss and current Dielectric

TYPE TESTS Type tests are performed on each new design per IEC 76 List of type tests performed Temperature Rise Impulse Test Short circuit tests can be performed on request. This is a special test described in IEC 76 part 5.

WHY USE ABB? Manufacture complies with: -ISO9001 Quality system -ISO 14001 Environment Management System (Certification due Q1 2003) Transformers are successfully in operation for over 50 years Units designed using proven ABB common technology Units can be optimised to suit particular loss requirements ABB is a volume producer ABB has experience of many specifications

WHY USE ABB? Short cycle times leading to shorter lead-times The galvanised tanks ensure long life Good quality and reliability Pressure testing insures leak free products Units have been successfully short circuit tested

A global leader in power and automation technologies that enable utility and industry customers to improve performance while lowering environmental impact Visit us at www.abb.com Visit us at www.abb.com.